Document kmX8gkbggB098GGg5JNdYxrJq
Air Conditioning
Chicago Steel Furnace Co.
9326 S. Anthony Ave., Chicago 17, 111. Manufacturers and Designers
Artcraft Heating & Air Conditioning Equipment
ired
DIRECT-FIRED SPACE HEATERS
350,000 Btu to 2,000,000 Btu
UNIFORM AIR DELIVERY
BLOWERS--Three standard up-blast discharge, multi-vane Blowers, each in dividually powered, are provided'to sup ply the correct amount of air to properly cool the Heat Exchanger. Individuallydriven Blowers are.used because of the great flexibility of operation obtainable. Uniform bonnet temperature may be enjoyed by the simple expediency of in creasing or reducing the amount of air driven around any particular section of the Heat Exchanger.
Performance Data Direct Fired Model A Units
MODEL
OUTPUT BTU
AIR DEL. CFM
350-A
500-A 750-A
1000-A 1250-A 1500-A 2000-A
350,000 3000-4200
500,000 000-7800
750,000 *`-'00-0600 1,000,000 12500-15500 1,250,000 15000-17500
1.500,000 17500-21000 2,000,000 21000-24000
L
72 92 100 114 124 128 144
W
40 42 50 54 56 62 66
H
84 90 99 no 114 115 125
ARTCRAFT SUSPENDED UNITS
Fired with Gas or OH
Ratings and Specifications Suspended Units
MODEL
75-S 75-SL 100-S 150-S 200-S 250-S 350-S 400-S 500-S 750-8
OUTPUT AIR DEL. BTU CFM-*"S.P.
85.000 85.000 100,000 150,000 200,000 250,000 350.000
400.000 500.000 750,000
800-1000 800-1000 1000-1600 1200-2000 2200-2600 2400-3200 3000-4200 4200-5200 4600-6200 8200-9600
L
63 78 76 79 86 90 104 107 114 146
WH
24 34 22 22 24 34 31 36 31 40 35 42 40 54 42 54 45 62 52 66
1182
Factory Inctallation Model tOOS-t
Air Conditioning
Automatic Equipment; Direct-Fired Heaters, Unit Heaters
Lee Corporation
1011 Tatnall Street, Wilmington, Delaware
Baltchobe, Md.
New-York, N. Y:
' Chicago, III.
Manufacturers and Designers of Complete Line of Industrial and Commercial Warm Air Heaters
Representatives in all Principal Cities
Exclusive Representation to the Railroads: Railroad Supply and Equipment, Inc., First Federal Bldg.. Scranton 3, Pa. In Canada: Comstock Lee Heating Division, Canadian Comstock Company. 206 Laird Drive North.
Leaside, Toronto, Canada
Lee Heater Number
Output Capacity (Btu per hr) Total Heating Surface in so ft Cu ft of Air per Min. (Approx.)* Fan Motor HP
External Static Pressure (Std ) Maximum External Static Press
Available for Duct Work (larger Motor Required) Temperature Rise (Degree F) Fuel Consumption** A-cu ft Gas per hr (App.) B-gal Oil per hr (Approx.) Shipping Weight (Approx.) Lbs Refractory Comb. Chamber
Stainless Steel Comb. Chamber
LEE HEAVY DUTY HEATERS
LEE HEATERS have been in continuous operation since 1918. Lee Heater in stallations have been, made in most of the States of- the United States, in Canada, Alaska, Yukon . Territory, Northwest Territory, Labrador, Iceland, Norway, Mexico and South America. Firing Equipment manufactured spe cially for us by leading Companies with International service organization. There is a Service man near you if and when you require assistance. In addi tion Lee maintains a competent field serving staff. Replacement and Spare Parts Service is maintained. Most items are carried in stock.
300 300,000
92 3500
Y l-
400
400,000 106 4500
i
Y
500
500,000 126 6000 2
Y Y
600
600,000 202 7000 3 jY
750
750,000 235 8500 5
r V
79
380 2.6
3000 2100
82*
500 3.5
3100 2200
77
630 . 4.3
3300 2400
79
750 5.2
4500 4000
82
940 6.5
4700 4200
Leo Heater Number
Uutput Capacity (Btu per hr) lotal Heating Surface in sq ft Cu ft of Air per min. (Approx.)* -ban Motor hp
External Static Pressure (Std.) Maximum External Static Press.
Available for Duct Work _ (Larger Motor Required) Temperature Rise (Degree F) Fuel Consumption**
A-cu ft Gas per hr. (Add.) B-gal Oil per hr. (Approx.)
Shipping Weight (Approx.) Lbs Refractory Comb. Chamber Stainless Steel Comb. Chamber
1,000
1,000,000 278
11,500 5
Y Y
1250
1,250,000 333
14,000 7* Y Y
1500
1,500,000 375
17,000 10
Y Y
1750
1,750,000 423
20,000 15
1'
2000
2,000,000 470
22.000 15
j* r
80
1250 8.6
6000 5200
83
1560 10.8
6300 5500
82
1880 . 13.0 .
7500 6200
81*
2190 15.0
8600 7400
84*
2500 17.2
9800 8600
*Bssed on Standard Air at 70 F Free Delivery. Fuel Consumption Based on 1000 Btu per cu It Cas, 145,000 Btu per Gal Oil, and on 80 per cent Effi
ciency for the heater.
1183