Document kmVorKBdZnXN8rx3Qv0gdvZO0

Moiusanto Lhemical Company J ANNISTON, ALABAMA DIRECTIONS 70S TEST NO* 14-8&-41 SUBJECT: Dielectric Strength of Liquid Aroclor ^ frj *- >. . 'a# - Lmethod: >rj vm '* ^ ~* 1 v^ ' ' ?- - * * * , -s"11 . 4 ` . - . > Ji ,'?& Scop#}>.^'5K ,.:^,n . , # -.. ^,,r, > V>ft - *,T _,; F'^%, This method applies to mineraloils and oil substitutes used Apparatue Capaeltenoe Bridge General Radio Go*, Type 716-Alf Cathode Say Null Detector " " Type 707-A Oscillator * " " Type 60S-A Constant Temperature Oven CencoHDeEhotinsky #95060 Variable Air Condenser General Radio Co*, Type S34r7 \. 1500 oc* Fyrex Beaker . - '' \ . i A- F; `1 #- "ffc*'-rV '.'.:'.. , ><;:j: . \- . . r ifr. , - -- '*? ?. r: - ' ' Procedure " - / ' " .. '" Electrode and beaker aust be cleaned as directed under "Clean ing Apparatus for Dielectric Constant", and he at 100*0* Heat Aroolar in the can to 105*C* Pour over electrode until plates and ceramic insulation is covered* Connect leads* Stir with thermometer outside oven until temperature reaches 101*J place in oven which has been carefully adjusted to 100*C* At the time sea-- pie is placed in oven its teaperature should not have fallen below . 90*C* . ;'"x .:\ ... . ' . ' Connect leads to capacitance bridge, observing that the lead from insulated side of condenser goes to insulated terminal on bridge* Balance bridge carefully according to direction under "Balancing Capacitance Bridge"* Until Aroclor and oven temperatures have be-- come identical the bridge balanoe will constantly shift* After oven temperature reaches 100*C*, maintain bridge balance until no pronounced shift is evident* Record reading of capaoitanee scale multiplied by multiplier setting* 4 - Dielectric Constant - Capacitance in Aroclor at 100*^ , A,.**. i *, - r.\ Capacitance in air at 100*C* ' r-- Balancing Capacitance Bridge Condensed procedure* Operator should read operating instruc tion for Null Detector for complete details* 1* Connect to power supply leads to oscillator and null detec tor* Ground the oscillator* DSW 330707 STLCOPCB4077351 Monsanto Lhemical Company ANNISTON, ALABAMA Page Ho* 2 Dielectric Strength of Liquid Aroclor -- Test 14-GS-41 2* Turn on oscillator by pushing 5000 ohm, 10 multiplier, 100 cycle frequency buttons* Adjust harmonic control until oscillation begins as shown by closing of sector in cathode ray tube* h?' : 3* On null detector turn brilliance knob to extreme left, the focus,knob to"extreme right, gain control to extreme left, sweep amplitude atmld--scale position, the sweep frequency switch on line Side* 4 Turn on power switch, lighting pilot light* 5* Wait fifteen seconds, turn brilliance knob to extreme right* 6* Adjust focus and bllliance knobs until sharp fine line* 7* Connect external terminals on detector to output terminals on oscillator* Switch sweep frequency to external side* x 8o Connect detector terminals of bridge to input terminals of detector, taking care that the black wire (ground wire) of the lead goes to grounded terminal on both ends of lead* 9* Set gain control at mid-scale and selectivity to extreme left* Turn sweep amplitude to extreme left, obtaining vertical line* With gain control make this about 1/4" long* 10* With turning control knob obtain the maximum, length of this line, keeping it always under 1/4 inch with gain knob* ; 11* Set sweep amplitude to extreme left* 12* Set gain control to give vertical straight line of about 3/6 . inch* . . .. . .. . . ' - . ......... ..... ... , . ... . 13* Balance bridge by adjusting power factor and capacitance dials until only a dot remains on the eereen when the gain control is at extreme right* ' , , < : ' vf. oi 14* Set sweep amplitude beyond mid-point, and slightly displace the power-factor dial to obtain a tilted ellpse* . 15* Adjust phase control until this ellipse closes into a straight line inclined to the horizontal* 16* Bring power-factor dial back to balance position, which should . restore the horizontal straight line* Displace this control the same amount in the opposite direction* This should again tilt the straight DSW 330708 STLCOPCB4077352 ; Maiidanta Lhemical Lompany ANNISTON, ALABAMA Page Bo* 3 Dielectric Strength, of Liquid Aroelor -- Test 14-36-41 line but in the opposite direction* Adjust phase control until there is no tendency for this line to open up when it is swung 30 degrees from horizontal in both directions* ' s ' ' > -. s\ , f* *' . 4 ,17* Throughout, these adjustments the other bridge control (the . ^ capacitance dial) must be in balance position* If the ellipse grad-* ` ually opens when the line Is horizontal it nay he brought back to the line again by making slight changes in this control* If confusion results, balance both controls again as in (13) and repeat the suc ceeding adjustments* ' This is the position of bridge balance: An alteration of the power-factor control will tilt the line which does not open apprecia-- ;| hie thru an angle of 30* to the horizontal both ways; an alteration of the capacitance dial opens the ellipse but does not change the inclination of the major axis* ^ H: The apparatus nay be left in this balanced condition, turned off is by switching off first the brilliance knob of the detector, then the power switch, then turning off the oscillator* . For successive measurements the controls are not changed, the apparatus left in adjustment* Then the following steps define the ^ `r,- procedure* `-v.,-- -, -.'v;" I ' ; ; l i-' 1* Connect all leads as previously directed including that from null detector to bridge* i ^ :* : ! 2* Turn on oscillator by pushing 100 cycle frequency button* ' i* 3* Turn bn null detector, wait 15 seconds then turn on cathode ray tube* Turn sweep amplitude to extreme left and adjust brilliance to obtain a fine vertical line on screen* 4* Bring this line to a dot by adjusting the two bridge controls* Initial adjustment is facilitated by having "Gain".control to left* When final adjustment is obtained this knob must be at extreme right* >;?<% . v ` 'V^;' 1- .' 5* This dot remaining unchanged shows condition of bridge balance* - is: Cleaning Apparatus for Dielectric Constant The condenser is removed from Aroelor while still hot by suspends ing it from the plate attached to the frame and allowed to drain. Never handle condenser by the Insulated terminal* After allowing to eool somewhat a 50-60 mixture of benzene-carbon tetrachloride is poured over condenser into the beaker used in the test* After draining it is washed in a mixture of equal parts benzene-tetrachloride* It is then washed successively in three different mixtures of benzener-tetrachlorde, drainr ing thoroughly between washes* Finally the electrode is placed on clean paper and brought to 100* in constant temperature oven* DSW 330709 STLCOPCB4077353 m f- . .......... ........... I Miidanto Lhemical Company ANNISTON, ALABAMA Bage Ho* 4 Dielectric Strength of Liquid Aroclor -- Test 14-06-41 Tbs beaker is rinsed with the cleaning mixture originally poured over the condenser, then washed with TSP* and hot water* After draining thoroughly ~it is dried at 100* in the oven* . v..~ r yd When handling the condenser the operator should never suspend it by the termlhal to the insulated plates* WBD-p E/12/42 ;_V.'.^5-.V! V y:. \rif. Ajj* - w Av. . - ' DSW 330710 STLCOPCB4077354