Document kmQvKxKVqREyxqMgM7MOM7a1b

Inter Olficu Mi'. M. K. Lindsey Safety Engineer Sharonville Plant Personnel and OrgenUttlon Statf 17 November 1983 oc J. B. Condon S. Grendel, M.D R. M. Brio D. Sbepler Subject: Asbestos References: l) Volume 29, Code of Federal Regulations, 1910.1001 2) IRAM Industrial Hygiene Bulletins No. 4 and 4a As requested, the samples which you submitted to the Industrial Hygiene Laboratory on 25 October I9S3 were analysed for asbestos content. The samples were ceiling liner from the Administration Building and pipe lagging from a washer steam line. Test resuitb, as shown on the attached data sheet, reveal that the ceiling liner oontains significant amounts of asbestos. Excessive exposure to airborne asbestos fiber and dust may cause eerious, irrevers ible adverse health effects many years after exposure. These include asbestosis, a progressively disabling lung disease, and cancer of the respiratory tract and of the chest and abdominal cavities. The long latency period between exposure and when disease may develop emphasizes the importance of preventive industrial hygiene control methods. Steps must be taken to assure that the asbestos in the ceiling liner does not become airborne. Therefore, if the ceiling is friable and not sealed by a false ceiling, the ceiling Bhould be encapsulated and removed when convenient. Further, the ceiling should be designated as asbestos and treated as an asbestos exposure area if it becomes necessary to repair the ceiling or otherwise drill, abraid, or cut the ceiling. If asbestos dust is generated, control methods including wet methods of dust suppression, use of effective respirators, vacuuming, local exhauBt ventilation, debris containment, and protective clothing must be followed. OSHA, as of 4 November 1983* bas promulgated an Emergency Temporary Standard (ETS) for asbestos of 0.5 fibers greater than five microns in length per cubic centimeter of air. In addition to controls that went into effect at the old two-fiber standard (i.e., posting, isolation, and protective equipment) employees must bo trained relative to asbestos health hazards if they will be exposed to asboBtoa concentrations exceeding the ETS. Jb Attachment H. B. Lick, Industrial Hygiene Associate Industrial Hygiene Section Employee Health Services 8006 1949 SCF-FORD-3392 PRODUCED BY FORD INDUSTRIAL HTQXENE SECTION ENVIRONMENTAL HEALTH AFFAIRS employee HEALTH SERVICES Sharonville Plant 25 October 1983 Meteria^L Administration Building oeiling liner Vaeher eteavline pipe lagging Asbestos Percent Composition Found 58% None detected DATA RETRIEVAL NUMBERS1 HBL 2105-2106 ANALYSIS* EPA Polarizing Microscope Method 13-17-83 8006 1950 PRODUCED BY FORD