Document kmQvKxKVqREyxqMgM7MOM7a1b
Inter Olficu
Mi'. M. K. Lindsey Safety Engineer Sharonville Plant
Personnel and OrgenUttlon Statf 17 November 1983
oc J. B. Condon S. Grendel, M.D
R. M. Brio D. Sbepler
Subject: Asbestos
References: l) Volume 29, Code of Federal Regulations, 1910.1001 2) IRAM Industrial Hygiene Bulletins No. 4 and 4a
As requested, the samples which you submitted to the Industrial Hygiene Laboratory
on 25 October I9S3 were analysed for asbestos content. The samples were ceiling liner from the Administration Building and pipe lagging from a washer steam line. Test resuitb, as shown on the attached data sheet, reveal that the ceiling liner oontains significant amounts of asbestos.
Excessive exposure to airborne asbestos fiber and dust may cause eerious, irrevers ible adverse health effects many years after exposure. These include asbestosis, a progressively disabling lung disease, and cancer of the respiratory tract and of the chest and abdominal cavities. The long latency period between exposure and when disease may develop emphasizes the importance of preventive industrial hygiene control methods.
Steps must be taken to assure that the asbestos in the ceiling liner does not
become airborne. Therefore, if the ceiling is friable and not sealed by a false ceiling, the ceiling Bhould be encapsulated and removed when convenient. Further, the ceiling should be designated as asbestos and treated as an asbestos exposure area if it becomes necessary to repair the ceiling or otherwise drill, abraid,
or cut the ceiling. If asbestos dust is generated, control methods including wet methods of dust suppression, use of effective respirators, vacuuming, local exhauBt ventilation, debris containment, and protective clothing must be followed.
OSHA, as of 4 November 1983* bas promulgated an Emergency Temporary Standard (ETS) for asbestos of 0.5 fibers greater than five microns in length per cubic centimeter
of air. In addition to controls that went into effect at the old two-fiber standard (i.e., posting, isolation, and protective equipment) employees must bo
trained relative to asbestos health hazards if they will be exposed to asboBtoa concentrations exceeding the ETS.
Jb Attachment
H. B. Lick, Industrial Hygiene Associate Industrial Hygiene Section Employee Health Services
8006 1949
SCF-FORD-3392
PRODUCED BY FORD
INDUSTRIAL HTQXENE SECTION ENVIRONMENTAL HEALTH AFFAIRS
employee HEALTH SERVICES
Sharonville Plant
25 October 1983
Meteria^L Administration Building oeiling liner Vaeher eteavline pipe lagging
Asbestos Percent Composition Found
58%
None detected
DATA RETRIEVAL NUMBERS1 HBL 2105-2106 ANALYSIS* EPA Polarizing Microscope Method
13-17-83
8006 1950 PRODUCED BY FORD