Document kmOr780kJB7KKb8JJwxXRJw4q
TECHNICAL CHANGE ORDER f)
CertairiTeedEI
CerlainTeed Corporation Pipe and Plastics Group
applicable to:
A/C Standard Product Specificat ion
Spec. #13
BVff 6f issue:
May 1 , 1982
T.C.O. NO.
5
PAGE NO.;
1
OiaCRIPTION:
A/C Storm Drain Pipe, Couplings and Accessories
Purpose:
1. Revise the specification to reflect the need for the product to conform only to ASTM C-663.
REF: J.R. Alley letter of A/13/81 to M.R. Streepy M.R. Streepy letter of 6/25/81 to J.T. McCahon
2. Class 2500D has been added, making the total five.
3. The new coupling label has been added.
A. A few minor dimensional corrections have been applied.
5. All of the B.O.D.'s from the former East Coast Spec, have been adopted for this National Spec.
6. Class V (3750D) dimensions for Els, Tees and Wyes have been added. This class should cover minor order quantities for Classes 2500D and IV. Large order quantities should be handled via NSP1 procedure for greater cost effect 1veness.
7. Class III (2000D) dimensions for Tees and Wyes have been expanded to include the full range of reducing branches. More orders are being received for double and triple reductions.
8. Plant Q.C. comments have been considered in this revision. (The previous 1/1/82 approved version was not Issued.)
Effective Date: May 1, 1982
Disposition of Superseded Pages:
Destroy Page 1, 2 3 A 5-9
10-1A
2/7/72 6/1 A/72 6/15/73 2/7/72 7/19/76
Substitute with revised pages attached.
CTD015411
Inventory Effects:
None. Where former pipe or fittings differ In B.O.D., they may be shipped
freely. However, shipment of the older stock first Is recommended.
PREPARED BY:
APPROVED BY!
R *O
MPO.
ALES
f.C.
OTHERS
y J-4.A.
02- `o-zm (p$ffliT~rcy7S CONFIDENTIAL OOCUMCNT - NOT TO BE DISTRIBUTED TO UNAUTHORIZED PERSONNEL
TECHNICAL SPECIFICATIONS
CertainTeed Hi
SPECIFICATIONS CLASSIFICATION:
A/C Standard Product Specification
T.C.O. REF. NO.
SPECIFICATION NO:
PADS NO.:
CertainTeed Corporation Pipe and Plastics Group
5
SUPERSEDES:
February 7
1972
13 1
OATS OF ISSUE:
May 1, 1982
OCSCRIRTION:
A/C Storm Drain Pipe, Couplings, and Accessories
General:
A/C Storm Drain pipe Is Intended for use In storm-water drainage of highways, farma, foundations and other drainage systems. It is manufactured in sizes 6" thru 24" and In Classes II, III, 2500D, IV, and V. Class II = 1500D, Class III - 2000D, Class IV - 3000D, Class V - 3750D where D Is the inside diameter expressed in feet multiplied by the numerical value in front to obtain the minimum crush value.
General Product Description:
Refer to General Product Specification Data "Section D" of the General Standards Manual for information concerning the following:
1. Composition 2. Finish 3. Straightness
Chemical Requirements: Uncombined Calcium Hydroxide - 1.0 percent maximum.
Conformance: All pipe manufactured under this specification will meet the requirements of ASTM C-663, latest revision.
Pipe Length: Standard Length - 13'0" + 0"-l" Random Lengths - 7'0" to 12'6" in 6" increments +0"-l"
No more than 15 percent random lengths of each size and class may be shipped on any one order.
CTD015412
PREPARCO BY:
02-10-0023 4/ao
APPROVED BY:
I1 (fo\Y JJZ.A-
CONFIOENTIAL DOCUMENT - NOT TO BE DISTRIBUTED TO UNAUTHORIZED PERSONNEL
ocscRimo*:
oatk or imuc: May 1, 1982
crcctricATtON no: 13
A/C Storm Drain Pipe, Couplings and Accessories
PAOK MO.: 2
Permissible Variations In Dimensions:
The average Inside diameter of the pipe may be less than the nominal size by not more than 1/4 inch or 1% percent, whichever is greater. The out-of-roundness tolerance, applying to the inside diameter at the ends of each length of pipe for a distance equal to the length of the machined end shall be as follows.
Size, Inches
6 to 20 inclusive 21, 24
Max. Out-of-Roundness, Inches
3/16 1/4
Couplings:
Coupling material shall be in accordance with CT Standard Purchasing Specification Ho. 550.
One coupling shall be supplied with each length.
Physical Requirements:
Each pipe shall have sufficent strength, when subjected to a three (3) edge bearing crush test, on the unmachlned portion of the pipe, to support not less than the indicated load shown below.
Class
D Load
Crush Load
II III 2500D IV V
1500D 2000D 2500D 3000D 3750D
1500 X (inside diameter la feet) 2000 X (inside diameter in feet) 2500 X (inside diameter In feet) 3000 X (inside diameter in feet) 3750 X (inside diameter in feet)
Examples: 6" 1500D - Crush load is 1500 x .5-750 lbs 18" 2000D - Crush load is 2000 x 1.5 - 3000 lbs
The crushing strength test shall be conducted in accordance with Standard Method of test ASTM C500 on a one-foot unmachlned length of pipe. The specimen shall be cut from a randomly selected pipe representing 300 lengths or less of each size and class produced during a 24 hour period for sizes 21 inch and below. For 24 inch size the specimen shall represent 300 or less lengths of Identical class during a period not less than 7 days.
TECHNICAL SPECIFICATIONS
CertainTeedlH
CertainTeed Corporation Pipe and Plastics Group
specifications classification:
A/C Standard Product Specification
T.C.O. REF. NO.
5
SPECIFICATION NO:
13
PAOE NO.:
3
SUPERSEDES:
June 14, 1972
OATE OF ISSUE:
May 1, 1982
description:
A/C Storm Drain Pipe, Couplings and Accessories
Marking:
Standard and Random Lengths
Standard Coupling
0
Unless otherwise directed, the marking of all Storm Drain Items shall be In brown Ink.
Standard and Random Lengths:
Area A * At the exact center of the pipe, the following shall be stamped:
CERTAINTEED (Size) (Class) TYPE II STORM DRAIN
Area B - Either to the right or left of Area A, the following information shall be
stencilled in black Ink on all standard lengths. (This information may appear on random lengths).
First Line - Month, Day, Year, Plant, Shift Second Line - Pipe No.
CTD015414
PREPAREO St:
02-10-0023 *7*0
APPROVED BY:
R o
<by J.4.A
CONFIDENTIAL DOCUMENT - NOT TO RE DISTRIBUTED TO UNAUTHORIZED PERSONNEL
description:
DATE OP IMUC
May 1 . 1982
mtCiriCATION NOt
13
A/C Storm Ora in Pipe, Couplings and Accessories
PAOE NO.:
4
Standard Coupling Area C - At the approximate center the following shall be shown as a minimum.
(Size) (Class) Pressure sensitive labels shall be used.
CertainTeedB
PLASTIC COUPLING
Fw UseWitt A/C SbiraDrain
INCH DIAMETER
D LOAD
CTD015415
TECHNICAL SPECIFICATIONS
CertairileedH
SFCCIFICATIONS CLASSIFICATION:
A/C Standard Product Specification
T.C.O. ASF. NO.
iPCCiriCATION no:
CertainTeed Corporation Pipe and Plastics Group
5
SUPSASCDSS:
February
7,
1972
13
OATS OF ISSUC:
May I, 1982
OSSCAIFTION:
A/C Storm Drain Pipe, Couplings and Accessories
rH r
CC~ 90 2
ana
Site Inches
Class
QD.
I.D." Nom.
O.D." .04"
--rt
i0 r - 3/16" radius 1/16"
C" p" * db.06"
H" -.00"**
B.O.D.1 + .08" -.00"
6
II
6.00
6.85
2.40
1.00
III
6.00
6.85
2.40
1.00
2500D
6.00
6.85
2.40
1.00
IV
6.00
6.85
2.40
1.00
V
r6?00
6.85
2.40
1.00
.06 7.04 .06 7.04 .06 7.04 .06 7.04 .06 7.04
8
II
8.00
8.90
2.40
1.00
III
8.00
8.90
2.40
1.00
2500D
8.00
8.90
2.40
1.00
IV
8.00
8.90
2.40
1.00
V
8.00
8.90
2.40
1.00
10
II
10.00 11.00
2.90
1.00
III
10.00 11.00
2.90
1.00
2500D
10.00 11.00
2.90
1.00
IV
10.00 11.00
2.90
1.00
V
10.00 11.20
2.90
1.00
.06 9.06 .06 9.06 .06 9.06 .06 9.12 .06 9.24
.06 11.14 .06 11.14 .06 11.26 .06 11.26 .06 11.43
12
II
12.00 13.06
3.13
1.50
III
12.00 13.06
3.13
1.50
2500D
12.00 13.06
3.13
1.50
IV
12.00 13.34
3.13
1.50
V
12.00 13.48
3.13
1.50
.06 13.24 .06 13.36 .06 13.52 .06 13.52 .06 13.70
14
II
14.00 15.14
3.13
III
14.00 15.14
3.13
2500D
14.00 '15.14
3.13
IV
14.00 15.46
3.13
V
14.00 15.84
3.13
* "CV Tolerance
6" thru 10" + .06" 12" thru 24" +.00"
1.50 1.50 1.50 1.50 1.50
12"
.06 15.32 .06 15.50 .06 15.70 .06 15.76 .06 16.00
Minimum "H" at least 2/3 of circumference. O.D. must be completely machined
ratPAaco ar:
AfMOWD av:
o.c.
02- 10-0023 /so
Or J.G.A.
COMF1OSNTIAL DOCUMENT NOT T6 BS DISTRIBUTED TO UNAUTHOMI1KD PERSONNEL
CTD015416
ocfcmmoN:
ordatk
issue:
May 1, 1982
SPECIFICATION MO!
13
' A/C Storm Drain Pipe, Coup 1ings and Accessories
PAOK NO.:
6
Size laches
15
16
18
20
21
24
Class
II III 25000 IV V
II III 2500D IV V
II III 2500D IV V
II III 2500D IV V
II III 2500D IV V
II III 2500D IV V
I.D." Nom.
O.D." .04"
15.00 15.00 15.00 15.00 15.00
16.00 16.00 16.00 16.00 16.00
16.26 16.26 16.26 16.68 16.90
17.30 17.30 17.30 17.74 17.98
18.00 18.00 18.00 18.00 18.00
20.00 20.00 20.00 20.00 20.00
21.00 21.00 21.00 21.00 21.00
24.00 24.00 24.00 24.00 24.00
19.34 19.62 19.62 20.06 20.06
21.42 21.72 21.72 22.18 22.18
22.46 22.76 22.76 23.22 23.22
25.88 26.10 26.32 26.32 27.06
-
C" *
3.13 3.13 3.13 3.13 3.13
3.13 3.13 3.13 3.13 3.13
4.00 4.00 4.00 4.00 4.00
4.00 4.00 4.00 4.00 4.00
4.00 4.00 4.00 4.00 4.00
4.68 4.88 4.88 4.88 4.88
P" .06"
1.50 1.50 1.50 1.50 1.50
1.50 1.50 1.50 1.50 1.50
1.88 1.88 1.88 1.88 1.88
1.88 1.88 1.88 1.88 1.88
1.88 1.88 1.88 1.88 1.88
2.25 2.25 2.25 2.25 2.25
H" -.00"**
.06 .06 .06 .06 .06
.06 .06 .06 .06 .06
.06 .06 .06 .06 .06
.06 .06 .06 .06 .06
.06 .06 .06 .06 .06
.06 .06 .06 .06 .06
B.O.D." +.08" -.00"
16.42 16.62 16.82 16.92 17.12
17.50 17.74 17.94 18.04 18.30
19.60 19.86 20.10 20.30 20.58
21.78 22.06 22.32 22.52 22.82
22.86 23.18 23.44 23.62 23.96
26.14 26.48 26.80 27.00 27.40
* "C" Tolerance
6" thru 10" +.06" 12" thru 24" +.00" -.12"
** Minimum H" at least 2/3 of circumference . O.D. must be completely machined.
NOTE - A tool bar which woul d machine an O.D.2 a maximum of 1.5 Inches beyond the C dimension 1 s permltted but the H dimension Is critical and must be maInta1ned. The standard machining Is preferred.
CTOOA541T
TECHNICAL SPECIFICATIONS
CertainTeedlH
CertainTeed Corporation Pipe and Plastics Group
DESCRIPTION:
SPECIFICATIONS classification:
A/C Standard Product Specification
T.C ?o~ ref. no'
SPECIFICATION NO!
5 13 7
supersedes:
DATE OF ISSUE:
February 7, 1972
May 1, 1982
A/C Storm Drain Pipe, Couplings and Accessories
Size Inches
6
8
10
12
14
PREPARED BY:
Y>|
02-10-0023 4/SO '
Class
11 111 2S00D IV V
II III 2500D IV V
II III 2500D IV V
II III 2500D IV V
II III 2500D IV V
<pll
+.02" -.01"
.12 .12 .12 .12 .12
.12 .12 .12 .12 .12
.12 .12 .12 .12 .12
.15 .15 .15 .15 .15
.15 .15 .15 .15 .15
C.O.D."**
6.93 6.93 6.93 6.93 6.93
8.97 8.97 8.97 8.97 8.97
11.05 11.05 11.05 11.05 11.24
13.15 13.15 13.15 13.42 13.56
15.21 15.21 15.21 15.52 15.89
Cut Length*
21-1/2 21-1/2 21-1/2 21-1/2 21-1/2
27-29/32 27-29/32 27-29/32 27-29/32 27-29/32
34-7/16 34-7/16 34-7/16 34-7/16 35-1/32
40-15/16 40-15/16 40-15/16 41-25/32 42-7/32
47-13/32 47-13/32 47-13/32 48-3/8 49-9/16
APPROVED BY:
o.c.
3 Ok J.A.A
CONFIDENTIAL OOCUMENT - NOT T(f SE DISTRIBUTED TO UNAUTHORIZED PERSONNEL
L" -.0" +.125'
5.00 5.00 5.00 5.00 5.00
5.00 5.00 5.00 5.00 5.00
6.00 6.00 6.00 6.00 6.00
6.75 6.75 6.75 6.75 6.75
6.75 6.75 6.75 6.75 6.75
CTD015418
description:
OAT* Of lUUf:
May 1, 1982
SPECIFICATION NO*
13
A/C Storm Drain Pipe, Couplings and Accessories
PAOK NO.:
8
Sice Inches
15
16
18
20
21
24
Class
II III 2500D IV V
II III 2500D IV V
II III 2500D IV V
II III 2500D IV V
II III 2500D IV V
II III 2500D IV V
Tf> +.02"
-.01"
.15 .15 .15 .15 .15
.15 .15 .15 .15 .15
.18 .18 .18 .18 .18
.18 .18 .18 .18 .18
.18 .18 .18 .18 .18
.21 .21 .21 .21 .21
C.O.D." **
16.30 16.30 16.30 16.73 16.95
17.34 17.34 17.34 17.77 18.02
19.42 19.69 19-69 20.13 20.13
21.47 21.77 21.77 22.24 22.24
22.51 22.81 22.81 23.27 23.27
25.96 26.18 26.39 26.39 27.13
Cut Lenttth*
50-27/32 50-27/32 52-27/32 52-3/16 52-7/8
54-3/32 54-3/32 54-3/32 55-15/32 56-1/4
60-17/32 61-13/32 61-13/32 62-25/32 62-25/32
67 67-15/16 67-15/16 69-13/32 69-13/32
70-1M 71-3/16 71-3/16 72-5/8 72-5/8
81 81-11/16 82-11/32 82-11/32 84-11/16
L" -.0" +.125"
6.75 6.75 6.75 6.75 6.75
6.75 6.75 6.75 6.75 6.75
8.50 8.50 8.50 8.50 8.50
8.50 8.50 8.50 8.50 8.50
8.50 8.50 8.50 8.50 8.50
10.25 10.25 10.25 10.25 10.25
* Cat Length before welding. Including .101" for welding loaa.
* &>t Length Tolerance
6. 8". 10" --- +0" -1/811 12", 14" ... +o" -3/16"
15", 20",
16" 21" .
18" 24"
-- ---
40" 40"
--17//216< "
**
-
C.O.D. Tolerance
6", 6". 10" --- 4.02" -.05" 12", 14" --- 4.02" -.07" - 15",-16", 18" --- 4.02" -.15" 20", 21", 24" -- 4.02" -.17"
CTOOA5^9
TECHNICAL SPECIFICATIONS
CertainTeedEI
SPECIFICATIONS CLASSIFICATION:
A/C Standard Product Specification
T.C.O. REF. NO.
SPECIFICATION NO:
PAOE NO.:
CertainTeed Corporation Pipe and Plastics Group
5
supersedes:
July 19, 1976
13
9
DATE OF ISSUE:
May I, 1982
description:
A/C Storm Drain Pipe, Couplings and Accessories
A5 and 90 ELBOWS
Ply.;
Si.To, Inches
10 12 1 is
15 16 16
20 21 2V
Non. I.O.. > n.
6.00 0.00
10.00
12.00
1>|.OO
15.00 16.00 16,00
20.00 21.00
2*.00
L"
+ .00''
-.50"
19.50 19.50 19-50 19.50 19.50 19.50 19.50 39.00 39.00 39.00 39.00
B.O.P.", Hln. Ml V
7.06 9.06
i 1. 1 6
13.16 15.50 16.62 I 7.7<* 19-66 22.06 23.16 26.68
7.0'1 9.26
11.1-3 13 70 16 00
1178..1320
20.50 22.82
23.96 27-60
toove excess 00 Inside for saooth surface.
For fabrication of 90 Elbows, add fillet Co center of 45 elbow*
4, Epoxy fillet on all outside adjoin ing surfaces.
5 Tolerances on 90 elbows 45.
6 One plastic coupling shall ac company each elbow.
CTD015420
PREPARED SY:
APPROVED BY:
R aD
MFO.
SALES
I.E.
OTHERS
*5^ J.fiA.
02-10-0023 (P927) 12/76 CONFIDENTIAL DOCUMENT - NOT TO SC DISTRIBUTED TO UNAUTHORIZED PERSONNEL
description:
OATS OP imuc:
May 1, 1982
SPECIFICATION NO.
13
PAOS no.:
10
A/C Storm Drain Pipe, Couplings and Accessories
HARKING EXAMPLE: (Centered on Main)
CERTAINTEED STORM DRAIN TYPE II 16" x 16" x 15" TEE
CLASS 11
NOTES: I.
For main and branch end machined dimensions, refer to standard pipe ends in Spec. 13-
2. One plastic coupling to accompany each main and branch.
CTD015A21
OO CM
LA
OO +
TECHNICAL SPECIFICATIONS
CertairfleedBi
CertairiTeed Corporation Pipe and Plastics Group
SPECIFICATIONS CLASSIFICATION:
A/C Standard Product Specification
T.c.o. REF. NO.
5
SPECIFICATION no:
13
FAOE NO.:
n
SUPERSEDES:
DATE OF ISSUE:
July 19, 1976
May 1, 1932
OCSCRIFTION:
A/C Storm Drain Pipe , :oup! i ngs anc Accessories
TEE FI TTING
Ma i n 3!pe L" Size, In. 6
", 3. 00" For Mains of Branches Indicated (All Classes) 8 10 12 11* 15 16 18 20 21 24
6x6
39
8x8
39 39
10 x 10 39 39 39
12 x 12 39 39 39 39
11* X 11* 39 39 39 39 39
15 x 15 39 39 39 39 39 39
16 x 16 39 39 39 39 39 39 39
18 x 16 39 39 39 39 52 52 52 52
20 x 20 39 39 39 39 52 52 52 52 52
21 x 21 39 39 39 39 52 52 52 52 52 52
21* x 24 39 39 39 39 52 52 52 52 52
Ha In Pipe
Branch Pipe
Size, Inches
6 8 10 12 11* 15 16 18 20 21 21*
AH Classes Nom. 1.D .1"
6.00 8.00 10.00 12.00 11*.00 15.00 16.00 18.00 20.00 21.00 21*. 00
B.O.D.i ', Min. 11 111 V
7.01* 9.06 11.11* 13.36 15.50 16.62 17.7^4 19.86 22.06 23.18 26.1*8
7.01* 9.21*
11 .1*3 13.70 16.00 17.12 18.30 20.58 22.52 23-96 27.1*0
Size, All Classes B.O.D.b , Min."
Inches Nom. 1.0 .2" HI
V
6
6.00
7.04
7.04
8
8.00
9.06
9.24*
10
10.00
11.43* 11.43*
12
12.00
13-36 13.70
11*
14.00
15.50 16.00*
15
15.00
16.62* 17.12*
16
16.00
17.74* 18.30*
18
18.^0
19.86* 20.58*
20
20.00
22.06** 22.52*
21
21 .00
23.18** 23.96*
21*
24.00
26.48 27.40
*Branch requires reworking for proper fit at "G".
**Branch should be rolled heavy for proper fit at "G". Reducing branch use 20" - B.0.D-2 - 22.52 ", 21' ' -B.0.D.2 = 23.96
PREPARED SY:
APPROVED BY:
R AD
MFO.
SALES
I.E.
Q.C.
OTHERS
02- 10-0023 4/0
J.&.A.
CONFIOCNTlAL DOCUMKNT NOT TO BE DISTRIBUTED TO UNAUTHORIZED PERSONNEL
CTD015422
ocaotimoM:
DATE Or IHUC: May 1, 1982
qPCCirtCATION NO! 13
MAC NO.} 12
A/C Storm Drain Pipe, Couplings and Accessories
TEE FITTING
j|t"c * .25" Reducing Branch Sire (All Classes)
Inches 6 8 10 12 14 15 16 18
8x8 10x10 12x12 14x14
15x15 16x16 18x18 20x20 21x21 24x2*1
6.25 6.50 6.50 6.50 7.00 6.50
6.75 6.75 7.40
6.75
6.50 6.50 6.50 8.10 6.50
6.75 6.75 8.50 7.00
6.75 7.00 8.10 7.00
7.25
7-25 8.50 7.50
7.00 8.60 7.00
7.25 7.25 9.00 7.50
9.00
7.25 7-50 7-50 9-50 7.50
7.00
7.25 7-50 9-50 7-50
7.50 7-50 8.25 9 - 50 10.00 7-50 b.25
20
10.00 8.25
Pip. Size, Inches
6 8 10 12 14
15 16 18 20 21 24
Lg" t .25" (Non-Reducing Branch)
hi V
5.48
5.72 6.78
6.07 6.50 8.19
6.38
7.32 7.22
8.91 7.01
5.48
5.63 5-98
5-90 6.25 7.94 6.10 6.96 6.99 8.52
6.55
Inches
6x6 8x6 10x10 12x12 14x14 15x15 16x 16 18x18 20x20 21x21 24x24
6 ~B-- 10
9.00 10.25 10.25 11.50 11.50 12.50 12.50 13.50 13.50 14.50 15.60 14.50 14.50
15.75 15.75 16.75 16.75 17.90 19.00 18.75 19.00
11.75 12.75 14.00 15.60 15.00
16.25 17.25 19.00 19.50
12
12.75 14.00 16.10 15.00 16.25 17-25 19-50 19-50
F" (All Claiiei) Branch Size, Inches
n-- 15
i
18
14.25 16.50
15.25 16.50 17.50 20.00 19.so
16.50 15.00 16.25 17.50 20.00 19.50
15.25 16.50 17.50 20.00
19.50
17.25 18.25 20.50
20.25
20
18.25 20.50 20.25
21
20.50 20.25
24 20.2$
For Main Pipe Sizes,
Inches
la* ' + .25" All Classes
6x6 8x8 10x10 12x12 14x14
15x15 16x16 18x18
20x20 20x20 21x21 21x21 21x21 24x24 24x24 24x24
6" Branch All Branches A1! Branches Al 1 Branches Al 1 Branches All Branches Al1 Branches All Branches Through 12" lV' Through 20" Through 12" IV* Through 20" 21" Branch Through 12" 14" Through 21" 24" Branch
10.0 11.0 12.5 13-5 14.5 16.5 16.5 18.5 13.0
19-5 15-5 19-5 20.5 15.5 19.5 21.5
For Indicated Branch Pipe Size, In.
6 8 10 12 ]k
15 16 18 20 21
G" + .04",-.01" (Reducing Only
III V
7.06 9.08 11.32 13.26
15.52 16.58 17.62 19.82
22.34 23.68
7.06 9.16 11.32
13.72 15.86 16.96 18.08 20.22 22.34 23.68
Plp Slza, In.
in
6 6.28
8 6.47 10 6.93 12 6.88 14 6.75 15 8.32 16 7.70
18 8.60 20 8.34 21 8.67 24 8.20
: .06" .00"
V mi V
6.2a 6.38 6.78
6.(5 6.50
7.94 7.35 8.21
8.24 8.52 7.80
13.32
15.53 18.07 20.14
22.25 24.94 25.44
28.46 30.40
31-85 34.68
13.32 15-62 18.21
20.35 22.50 25.06
25.65
28.79 30.76 32.48 35.20
i I
CTD015423
TECHNICAL SPECIFICATIONS
nCIFICATIONI CLASSIFICATION:
CertairifeedU
CertainTeed Corporation Pipe and Plastics Group
A/C
T.C.O. MSF. NO.
5
Standard Product
SFCCIFICATION NO:
13
Specification
FAOB NO.:
13
UFCftSCDCS:
July 19, 1976
DATS OF IBSUB:
May 1, 1982
oucairriON:
A/C Storm Drain Pipe, Couplings, and Accessories
A5 WYE FITTING
MARKING EXAMPLE: (CENTERED ON MAIN)
CERTAINTEED STORM DRAIN TYPE
10" kS WYE CLASS III
II
NOTES:
1. For main and branch end machined dimensions, refer to standard pipe ends in Spec. 13-
2. One plastic coupling to accompany each main and branch.
V fc*PREPARCD by:
02-10-0023 4/SO
AFFNOVKO BY!
JJtA-
CONFIDENTIAL DOCUMENT - NOT TO SB DISTRIBUTED TO UNAUTHORIZED PIRIONNCL
CTD015424
DMCRirrKM:
OATS or IMUKI May 1, 1982
SMClriCATION HOI 13
MAC no.:
14
A/C Storm Drain Pipe, Couplings, and Accessories
45 WYE FtTTtNG
Ma i n Size
1 nches
8x8 10x10 12x12 14x14
15x15 16x16 18x18 20x20 21x21 24x24
L/' .25" Reducing Branch Size (All Classes) 6 8 10 12 14 15 16 18 20
6.25 6.50 6.50 6.50 7.00 6.50
6.75 6.75 7.40 6.75
6.50 6.50 6.75 6.50 7.00 8.10 8.10 6.50 7.00
6.75 7-25 6.75 7-25 8.50 8.50 7.00 7.50
7.00 8.60 7.00
7-25 7-25 9-00 7-50
9.00
7.25 7.50 7-50 9-50 7.50
7. 00 7. 25 7. 50 9. 50 7. 50
7.50 7.50 8.25 9.50 10.00 10.00
7.50 8.25 8.25
21 8.25
Size, 1 nches
6x6 8x8 10x10 12x12 14x14
15x15 16x16 18x18 20x20 21x21 24x21*
Main PI pc
All Classes Nom. 1.D.V
6.00 8.00 10.00 12.00 14.00 15.00 16.00 18.00 20.00 21.00 24.00
B.O.D.'i , Min. 111 V
7.04 9.06 11.14 13.36 15-50 16.62 17.74 19.86 22.06 23.18 26.48
7.04 9.24
11.43 13.70 16.00 17.12 18.30 20.58 22.52 23-96 27.40
Size, Inches
6 8 10 12 14
15 16 18 20 21 24
Branch Pipe
All Classes Nom. 1.D.9
6.00 8.00 10.00 12.00 14.00 15.00 16.00 18.00 20.00 21 .00 24.00
B.O.D.? Min. . Ill V
7.04
7.04
9.06
9.24*
11.43* 11 ,4R*
13.36 13-70
15.50 16.00*
16.62* 17.12*
17.74* 18.30*
19.86* 20.58*
22.06** 22.52*
23.18** 23.96*
26.48 27.40
*Branch requires reworking for proper fit at "G".
**Branch should be rolled heavy for proper fit at "G". Reducing branch use 20" - B.O.D.j = 22.52", 21" B.0.D.2 " 23.96".
CTD015425
TECHNICAL SPECIFICATIONS
SPECIFICATIONS classification:
CertairifeedH
CertainTeed Corporation Pipe and Plastics Group
ocacaimoN:
A/C Standard Product Specification
T.C.O. SEF. NO.
SPECIFICATION NO!
PAOE NO.:
5 13 15
supersedes:
OATS OF issue:
July 19, 1976
May 1, 1982
A/C Storm Drain Pipe, Couplings, and Accessories
A5 WYE FITTING
Main
Inches
6x6 8x8 10x10 12x12 14x14 15x15 16x16 18x18 20x20 21x21 24x24
U1 + .00" -.25" All Classes
S
13.0
11.9 11.8 12.2
12.2
14.9 12.1 13.2 13.8 15.6 13.7
8-- 10
14.3 15.7
17.7 16.7
19.6
21.9 23.8
17.3 25.7
15.7 17.7 18.2 19.6 21.9 23.8 18.8
25.7
12
17-7 19.8 19.6 21.9 23.8 20.4 25-7
14
21.3 19.6 21.9 23.8 22.0 25.7
15
19.6 21.9 23.8 22.7 25.7
16
21 .9 23.8 23.5 25-7
T8
23.8 25.1 25-7
20
26.6 25-7
2l 25-7
W
Main Size, Inches
6x6 6x8 10x10 12x12 14x14
15x15 16x16 !8x!S 20x20 21x21 24x24
16.5
16.5
17.5
13.0
20. 0
23. 2
2J1li,.
0 0
25. 0
27. 1
27. 0
19.0 20.0
22.5 25.5 25.0
28.5 32.0 35.0 28.8
37.0
10
22.0 22.5 25 5 26 5 28 5 32 .0 35 0 30 3 37 .0
M' - All Classes
Branch Size , Inches
12 IT 15 16
23.5
25. 5 28. 1
28. 5 32. 0
35. 0
31. 9 37. 0
27.5 29.6
28.5 32.0 35.0
33.5 39.0
30.4
28.5 32.0 35.0
34.3 39.0
31.5 32.0 35.0 35.0
39.0
rr
34 5 35 .0 36 .6 39 .0
20
37.5 38.2 39.0
21
39.0 39.0
tpt
42.0
Main Size, Inches
6x6 8x8 10x10 12x12 14x14 15x15 16x16 18x18 20x20 21x21 24x24
F" - All Classes Branch Size, nches
6 8 10 12 14 15 16 18 20 21 24
15.00
16.25
17.75 19.00 20.50 22.30 22.00
23.25 24.75 26.60 27.50
19 .00 19 .50 20 .75
23 25 24 .80
23 .75 25 .00 26 .50 29 .00
29 .so
21 75 22. 75 24. 00
26. 30
25- 25 26. 75 28. 25 30. 50
31. 00
23. 50 25. 75 28 20
25. 00 26. 50
27. 75 32. 50 JO. 75
27.25 29-70
28.50
29.75 31.25 33.90 34.00
29.70 29.50
29.75 31.25 34.20 34.00
31-25 31.25 32.75 35.10 35.50
34.25
35.25 36.80
37.50
37.25 37.80
39.75
38.10 39.00
41.75
by:
1 Anenovxo ay:
n ft d
MFS.
SALES
I.E. o.c.
Ja.a
ioN^iOCKTIAL DOCUMENT - NOT TO BC DISTRIBUTED TO UNAUTHORIZED PCRSONNKL
CTD015426
description:
ordate
issue:
May 1, 1982
4PCCinCATION NO!
13
A/C Storm Drain Pipe, Couplings, and Accessories
PAD* NO.i
16
1*5 WYE FITTING
For Indicated Branch Pipe Size. In.
6 8 10 12 14
15 16 18 20 21
G" + ..04",-.01" (Reducing Only)
1 11 V
7.06 9.08
11.32 13.26
15-52 16.58 17.62 19.82 22.34 23.68
7.06
9.16 11.32
13.72 15.86 16.96 18.08 20.22 22.34 23.68
For Indicated Branch Pipe Size, In.
6 8
10 12 14
15 16 18 20 21
. + .00" < -1.00"
(All Classes)
14.25 17.25 19.75 20.75 25.00 27.50 27.50 30.50 34.00 35.00
For Indicated Branch Pipe Size, In.
6 8 10 12 14
15 16 18 20 21 24
<-g"
111
15.03 17.10 19.62
20.72 24.32 26.94 27.81 30.37 32.91 34.18 36.49
.25"
V
15.03 17.08 19.62 20.66 24.18 26.85 27.70 30.23 32.83 34.03 36.33
L|P - .25" 11 1 V
7.95 8.01
8.13 7.32 8.78 10.28
10.03 10.47 10.81 IO.96
9.97
7.95 7.79 8.13 6.91 8.13 9.68
9.35 9.60
10.25 10.01 8.86
Pipe Size,
In.
6 8 10 12 14
15 16 18 20 21 24
L., + .00" LU -.06"
III V
7.95 7.95 8.01 7.79 8.20 8.14 7.32 6.91 8.73 8.13 10.28 9.68 10.03 9.35 10.47 9.60 10.81 10.'25 10.96 10.01 9.97 8.86
.11 +.06" E -.00"
III V
17-96 20.88 24.42
26.27 30.70 33.84
35.17 38.61 42.06
43.79 47.48
17.96
20.91 24.36 26.34 30.81 33.94 35.28
38.76
42.15 43.95 47.66
CTD015427