Document kmOZja8vybQkm2NX98yZY9LLy
380
Heating Systems bm<, c.
The Sonner Burner Company
gmmmw
DESIGNERS AND MANUFACTURERS OF GAS
CONVERSION BURNERS
OFFICES AND FACTORIES : WINFIELD KANSAS
Smr Gas Conversion Burners are a product of nearly a half
century of specialisation in design ana manufacture. Many of
the Sooner Conversion Units feature the Blue Ribbon Flame LV Burner Head with Airblend Design. Each ribbon of flame
receives all the oxygen it needs to support complete effective combustion--from both sides along its full length--because the extraordinary Sooner Airblend Design provides just the right
amount of secondary air in the right places. Catalog 6i~L~t gives complete description of this efficient blue ribbon of flame. A wide range of designs provides a Sonner Burner for do mestic, commercial, or industrial use. Sonner engineering serv ice is always available for consultation; write for catalog con
taining complete line.
Type LVS Step-Fire Burner assemblies for large heating
plants and power boilers where load varies to such extremes as to mntfA this operation desirable. Three step control is the
arrangement although it may be altered to meet engi
neers' specifications. Standard assemblies using the Sonner Blue
Ribbon Flame LV Burner head with airblend design which provides just the right amount of secondary air to support
complete and effective combustion, capacities for 1,440,000 to 7,200,000 Btu/hr are described in Catalog 57-LVS-I. Larger ca
pacities available; consult Sonner engineering service.
Type H Heat Machine is designed specifically for the con version of residential heating plants, either round warm air furnace or a rectangular boiler, to gas. Completely automatic burner, using the Blue Ribbon Flame LV Burner head with air blend design, is A.GA. listed. Available in two sizes with ca pacities ranging from 75,000 to -400,000 Btu/hr. See Catalog
6S-L-B.
Type WX-55 Sooner Burner specifically designed for re placing ral1 gun type oil burners in domestic furnaces and boilers, A.GA. listed with inputs ranging from 75,000 to
200,000 Btu/hr. See Catalog WX-55-1.
Type R Sonner Burner with horizontal flame for conversion of scotch marine boilers and similar equipment to gas and stand-by fuel applications. A multiple-venturi burner in fac tory built fully assembled form. Standard assemblies from
240,000 to 7200,000 Btu/hr. See Catalog 68-R-l. Larger capaci ties available; consult Sooner engineering service.
Gas-Oil Unit for commercial and industrial boilers, two fuel
burning units, each designed for one fuel only--natural gas and light fuel oils. For capacities from 280,000 to 2,800,000 Btu/hr input; See Catalog 6S-CJ-1. Larger capacities avail
able; consult Sonner Engineering Service.
nr
Heating Systems * Baatn, OR
381
THE CARLIN COMPANY
912 SILAS DEANE HIGHWAY WETHERSFIELD 9, CONN MANUFACTURERS OF OIL BURNERS AND OIL-FIRED HOT WATER HEATERS
Pressure-atomizing, fully automatic, gun-type Oil Burners for residential and commercial in stallations.
..c>; -
The Carlin Company manufactures a complete line of quality oil burners in capacities from 0.65 to 20.00 gph for use of No. 2 grade fuel oil. Pedestal and flange mounted models are offered. Mounting to popular makes of boilers and furnaces is mnH* easy with a wide selection of flanges and mounting plates especially developed by U.S.-Cariin. Advanced design featuires include the "Shell Head,'' a significant improvement in oil burning which develops higher combustion temperatures, makes heat-wasting soot deposits negligible, conserves fuel.
With either distillate or catalytic fuels, operation is quiet, clean, economical. Generous use of heat and corrosion resistant alloys guards against deterioration--mulcts cleaning easier.
U.S.-Carlin Oil Burners are available with Electronic Controls which comply fully with Underwriters' Labora tories latest safety switch timing requirements. Many types are factory mounted and wired to insure proper hook-up and save on-the-job wiring expense.
For complete technical literature including consulting en gineers' manual, specification sheets, electronic controldata, combustion chamber dimensions, etc., address The Carlin Co., 912 Silas Deane Highway, Wethersfield 9, Conn.
CONDENSED SPECIFICATIONS
MOTOR--Long-hour duty with safety overload control. Complies with NBMA mounting specifications. M hp. (Models *,150F 4Q0S, 150SF-2, 500S-35); % hp. (Models 650,700^35, 800S-4); X bp. (Model 1200); M hp. (Modeli'2000S-5, 2000).
TRANSFORMER--Shielded to block radio and TV inter ference. 10,000 volt (12,000 volt on Models 2000S-5,1200, 2000).
AIR TUBE--Steel with heat resistant air cone.
FAN--Precision balanced. Mounted directly on motor shaft.
NOZZLE--Stainless steel alloy. Hollow cone spray (Hollow cone or solid spray on Models 1200, 2000). Dual nozzles on Models 500S-35, 650, 700S-35, 800S-4, 2000S-5, 1200, 2000.
FUEL UNIT--Single-stage standard on Models 400, 150F, 400S, 150SF-2, 500S-35, 650. Two-stage on Models 700S-35, 800S-4, 2000S-5, 1200, 2000. Built-in strainer and pressure regulating valve. Capacity of strainer equals or exceeds maxi mum firing rate of burner.
SOLENOID VALVE--Combination delayed-opening and in stantaneous cut-off oil valve standard on all "S'* models, also 1200, 2000.
COMBUSTION HEAD--Models I5QF, 400, and 650 have standard head with diffuser vanes formed at a fixed angle to establish air pattern. Model 150F (0.65 to 1-35 gph capacity) and Model 400 (0.65 to 1D0 gph capacity) have a series of adustable openings in center of diffuser for regulating air deivery to shape the fire. All "S" Models have "Shell Head'' and finned collar for efficient .mixture of air with oil. Models 1200, 2000 have High Temperature Combustion Head with finned collar for greater firing rate (Model 2000) and narrower lire.
ELECTRODES--Nichrome steel with full-glazed porcelain insulators counterbored for utmost safety. Flared, "Wide-arc" design permits heavier spark and assures positive protection during low voltage periods.
BUS BARS--Rigid heavy-gage brass (Models 400, 4008, 500S35,7008-35, 800S-4); phosphor bronze (Models 150F and 150SF2); high tension leads (Models 650, 2000S-5, 1200, 2000).
HOUSING--Cast iron. Designed to assure efficient air de livery and quiet operation. Machined to rigid standards.
COUPLING--Universal type with neoprene center piece. (Flexible type on Models 2000S-5, 1200, 2000).
CONTROLS--Thermostat, Limit Control, and Stack Relay. - Electronic Control set in place of Stack Relay on Models 80QS-4, 2000S-5, 1200 and 2000.
ELECTRICAL CHARACTERISTICS--115V-60 cycle. 1725 rpm. All modelsexcept 150F and 15GSF-2 available with230V-60 cycleonspecial order. Also a complete line of 110 and 220V-50 cycle models with capacities from Q.50 to 15.00 gph.
Models 400, 400S, 15QF, 150SF-2, 500S-35, 700S-35 and 650 available for either flange or pedestal mounting.
MODEL 400 0.65 to 4.00 gph
MODEL 400S 0.75 to 3.00 gph
MODEL 150F 0.65 to 2.00 gph
MODEL 150SF-2 0.65 to 1.35 gph
MODEL 500S-3S 3.00 to 4.50 gph
MODEL 7QOS-35 3.50 to 7.00 gph
MODEL 650 3.50 to 6.50 gph
MODEL 800S-4 4.00 to 8.00 gph
MODEL 1200 MODEL 2000S-5. 7.00 to 12.00 enh 6.00 to 12.00 gph MODEL 2000, 10.00 to 20,00 gph
U.8.-Carlin 03 Burner* an listed by UtUcnrriUrt' LoboralarUt, Inc. aad an approved under U. S. Oeronmni Commtreial Standard C87SU. Grade of fuel oil mommended ia No. 1 U. S. OeocnmnU Commini Stanford C3SI.