Ethanolamines/Glycol Ethers
In Plant Training (IPT)
Section Number Issue Number Origination Date Revision Date Section Test
13 1.3 07-30-91 12-23-97
:13
Author: Mike Viator
Ethanolamines Water Removal Control Module T-240
Answers:
1. State what should be done if the recirculation flow is lost to E-240. Cut off the steam flow and correct the flow problem.
2. State what type cooling tower water should be used on E-241. All fresh water
3. Explain what could cause the loss of T-240 overheads to Environmental Operations. T-240 overheads emergency block valve (EBV) to environmental operations works on a difference in pressure trip control scheme. As the header pressure on the line to environmental operations approaches P-241 discharge pressure, the EBV trips to keep the liquid in the header from back flowing into our system.
4. Explain how the bottoms temperature control scheme works on T-240. The temperature controller (TIC-2152) is cascaded to the steam control valve (FIC-2163) to control the bottoms temperature on T-240.
5. Explain how the reflux temperature control scheme works on T-240. The VAX computer controls tray #13 temperature through the reflux controller (FIC-2151).
6. State what you would do if T-240 bottoms percent water were .09. Increase the temperature set point on controller TIC-2152.
7. State what you would do if T-240 overheads percent MEA were .18. On the VAX computer, increase the temperature set point on tray #13 which would decrease the column reflux.
Date Printed: April 18,1998 Paper Copies Of This Document Are Uncontrolled & Not Subject To Update.
The Controlled Document Resides In File: T:\ORIGINAL\IPT\EACONTRL\PURIFICA\ASOST240.DOC
Page 1 Of 3
DO A 058641
CONFIDENTIAL
8. Explain what process variable would cause the pressure on T-240 to rise. State what should be done to correct this problem. A. T-230 bottoms temperature (tray #4) too cool, ammonia in T-230 bottoms feed to T-240. B. Increase T-230 temperature control set point and flush VP-240 with fresh water.
9. State what should be done if you loose VP-240. Put EA-280 on T-240 until the vacuum pump can be put back in service.
10. State the water spec for T-