Document kmBeoryzOGMGE4oaVo0q9kqR0

Johnson Service Company Temperature Control Equipment How. to Specify Air Compressors--Specify kind of air Furnish and install a complete system of automatic temperature regulation and humidity control, furnishing all neces sary thermostats, valves, dampers, hu midifiers, special devices, air compressors, piping and fittings, and labor of installing system, except setting valves and dampers compressor (steam, hydraulic, electric or power driven), requiring that the air com pressor shall be of sufficient size to operate the system, with a factor of safety not less than 3, and requiring that it be provided with all necessary governing devices, fit tings, gage, etc. in position--all in accordance with the following schedule and detailed speci fication: Schedule--State the rooms to be con trolled and number of thermostats in each; the manner in which the tempered air, if there is any, is to be controlled; the manner in which the drafts of the boiler are to be controlled; and specify the manner of the control of any fresh air, vent or return air dampers, stating the location and number of switches. Thermostats--Where the greatest economy of fuel and the most flexible handling of the heating system is desired specify the Johnson Dual orTwo-Temper- ature thermostat and that it shall operate at all times at one set pressure not less than 15 lbs. per square inch. If dual thermostats are not desired specify Johnson Metal Diaphragm Model Ther mostat, size, x 2 x l in.; and state whether it is to have residence or school cover, indicating device, positive shut-off, and whether it is to be positive or inter Humidostats--Specify Johnson Humidostat and Humidifier, stating the kind of humidifier, whether perforated steam .or copper evaporating pan. Dampers--Specify that dampers shall be made by the heat regulating contrac tor, but installed by the galvanized iron contractor, and that dampers shall consist of wrought iron frames, sheet steel blades, strongly cleated, with brass bearings. Guarantee--Require that system be complete in every respect, and that all necessary material and special fittings shall be furnished whether specifically mentioned or not. Require that entire system be guaranteed free from all orig inal defects in material and workmanship, and that any parts proving defective or . wearing out within 2 years from date of completion shall be replaced free of charge. Require that thermostats shall operate.the valves or dampers to which they are at tached, at a variation of not to exceed 1 deg. above or below any given point. mediate motion. Specify the number and kind of inserted thermostats. Valves--Specify Johnson Metal Dia Contracting phragm Valve having the ``Sylphon" This company contracts to furnish.and Metal Bellows for its diaphragm. State install in complete working order the whether valves are to be plain or nickel- Johnson System of Temperature Control, plated with or without unions; add: including.thermostats, valves, piping, etc., Valves to be placed in position by heating and gives annual inspection and prompt contractor. service to all plants constantly. 488 Temperature Control Equipment The Powers Regulator Co. 34 years of specialization in temperature control GENERAL OFFICES AND FACTORY CHICAGO, ILL. 2719 GREENVIEW AVENUE GENERAL EASTERN OFFICES NEW YORK, N. Y. 126 EAST 44th STREET ATLANTA. GA. BALTIMORE. MD. BOSTON. MASS. BUFFALO. N. Y. BUTTE. MONT. CHARLOTTE. N. C. CHATTANOOGA. TENN. CINCINNATI. OHIO CLEVELAND. OHIO BRANCHES AND SERVICE STATIONS DENVER. COLO. DES MOINES. IOWA DETROIT. MICH. EL PASO. TEXAS HOUSTON. TEXAS INDIANAPOLIS. IND. KANSAS CITY. MO. LOS ANGELES. CALIF. MILWAUKEE. WIS. MINNEAPOLIS. MINN. NASHVILLE. TENN. NEW ORLEANS. LA. PHILADELPHIA, PA. PITTSBURGH. PA. PROVIDENCE. R. I. ROCHESTER. N. Y. ST. LOUIS. MO. SAN FRANCISCO. CALIF. SEATTLE. WASH. THE CANADIAN POWERS REGULATOR CO.. LTD.. TORONTO. ONT. BRANCHES CALGARY. HALIFAX. MONTREAL. VANCOUVER. WINNIPEG (so) Products control by which all other methods Automatic Temperature Con-. trolling Systems, applying them, under the supervision of the Powers engineers, to the heating are measured. In design. Powers thermostats are second to none in beauty and perfection of finish; in size, as small as is consistent with plants, new or old, in residences, the reliability so necessary in such offices, factories, schools, institu instruments; in operation, sure, tions, and to any other conditions with gradual or positive action, as of artificial heating where uniform conditions require. temperature is desired. Diaphragm radiator valves, Automatic Regulators for- AC diaphragm motors, mixing dam CURATELY controlling tempera pers and., other equipment are ture and pressure of Liquids, Gases and Air, Pressure Reducing Valves, D Thermostat especially rugged in construction, dependable and durable; built re Steam Traps, Humidity Control Devices, gardless of expense, whenever strength is Shower Mixing Valves, Etc. needed for efficiency and long service. Motive power used in these systems is Temperature^Controlling Appliances compressed air. The company, builds its Powers thermostats own air compressors, are accurate' in their working and wilt main tain their adjustment. They are of the vapor disc type, exclusive with Powers regulators, and are not thrown out of adjustment by extremes operated by steam, electricity or water, and characterized by their reliability, noiseless operation, perfect control and long life. of temperature or long disuse. For over thirty years the accurate con Installations Installations trol obtained by this of Powers sys method has been the tems are invari- ,, K Thermostat standard of thermostatic ably made by this Radiator Valve 489