Document km5bdDL3pEo9jqE0z40EEXQoV

I Heating Systems Boiier-Bumer mS-m} jwiKRSS. Aldrich Company 121 E. Williams St., Wyoming, Illinois Boiler-Burner Units, Domestic and Commercial Oil Burners Aldrich Boiler-Burner Units--available in 7 sizes for Hot Water Heating, Steam Heating, and Hot Water Supply--de signed for home, apartment, garage, club, restaurant, hotel, and factory installations. Gages, covers, and trim furnished to suit model and unit type ordered. Heavy-duty, double-spiral hot water coils factory-installed and tested in SC and WC models. Matched Al drich Oil Burner with each unit. Stand ard equipment includes full set of basic automatic controls. Series BG Boilers are gas-fired with A.G.A.-approved burn ers for first five sizes. Oil and gas burners are readily interchangeable. Welded steel fire box lined with cast re fractory having high resistance to de terioration. Large burner - mounting plate provides access to fire box for re placement of combustion chamber. ' Ex tra thick wool insulation blanket pro vides high insulating value and minimizes heat loss through radiation. Universal tappings on all models except "Bantam." BOILER-BURNER UNITS Sizes--Specifications--Dimensions Size of Boiler Bantam 118 160 225 315 514 808 Rating Sq. Ft. Hot Water 660 750 1000 1500 2100 3300 5000 Rating Sq. Ft. Hot Water Standing Radiation............ 440 Rating Sq. Ft. Steam EDR... 425 500 500 650 1000 1400 2200 3333 630 935 1275 2925 3000 Rating Sq. Ft. Steam StandingKadiation...................... Rating BTU Per Hr. (Max.).. 100,000 333 420 620 850 1350 2000 118,000 160,000 225,000 315,000 514,000 808,000 Water~Heater Delivery GPH >100 Rise.. 93 Storage Capacity Gallons...... 20 Firing Rate--GPH Maximum 1.00 Firing Rate--GPH Minimum .65 Firing Rate--GPH Best....... .75 Model Burner Furnished....... CXI Sq. Ft. of Heating Surface---- Ena Main Shell (Inside)........ 16J4# Height of Main Shell............. 42H' Dia. of Fire Box (Inside)...... 12* Height of Fire Box................. 21 Number of Tubes.................. Length of Tubee 15$** Output Hot Waterl wc--opm Coil @ 100 Rise I bc--qpm 3 125 28 1.25 .75 1.00 SAX1 21 19* 46M# 14M* 24* 16 15$** 1.75 2.00 190 38.5 1.65 1.25 1.35 SAX2 37 21* 60M' 16* 24* 20 19K* 3.00 3.75 280 450 72 99 2.75 3.65 1.75 2.4 2.00 2.5 SAX3 SAX3 44 67 24H'- 28* 58M* 66H' 19* 23H' 26* 26* 30 42 23M' 30H' 3.66 5.25 3.67 6.75 610 120 5.7 3.7 4.5 BX 93 32* 68M' 27* * 26* 60 6.50 8.00 850 170 9.00 6.00 7.5 BX 136 38* 70M' 26* 94 sm 7.25 10.00 Shipping Weight Lbs.--Boiler uy 440 697 843 1170 1760 1975 2370 Shipping Weight Burner Only......... Shipping Weight Lbs. 517 90 787 90 90 90 too 100 933 1260 1850 2075 2470 ALDRICH OIL BURNERS--Capacities from 0.75 gph to 19 gph. Models SAX-CX-BX-JU. 6 sizes, 4 models for domestic and commercial warm air, steam, or hot water systems. UL listed. SAX (illustrated) 3 firing ranges--0.75 to 1.35; 1.35 to 2; 2 to 4.5. Model CX 0.75 to 2. BX 4 to 8.5. JU 7 to 19.00 gph. 1332 MODEL DESIGNATIONS Without Coil Steam Heating Hot Water Heating Hot Water Supply S W HGS* With Coil Steam Heating Hot Water Heating SC wc Hot Water Supply - * Galvanised, with dress jacket. Heating Systems Boilers & Radiators Unit Heaters Brown Products Company 97-12 Metropolitan Ave., Forest Hills, New York Brown Bayce-Heetis a"high-output" baseboard designed for residential andcommercial use. This smart looking new unit has a rating of 1100 Btu at 215F. (4.6 sq ft EDR per lineal ft) made possible by the remarkable TILT-FIN design wherein two diagonally opposed fins are folded downward and the entire heating element (fins and tubes) is tilted to allow more efficient air circulation. For use on forced hot water or two pipe steam system. Heating element:)^ in. copper tubes expanded into rectangular beaded aluminum fins for greater strength and heat transfer area. Th>o*vt*Ij$ggS' Automatic Oil-Fired Boiler Burner Units Domestic Water Heaters Available in 6 sizes for hot water radiation 68,000-472,000 Btu/hr. For steam radiation 5 sizes available from 93,000472,000 Btu/hr (388-1965 sq ft EDR). Boilers come with built-in combustion chamber and flange mounted gun-type oilburner with controls. Available with 3, 4, or 5 gal instantane ous coil for hot water. Publication 100-2. mgr CONVECTOR UNITS (gggr"JglMyH'n Brown Heet Convector Units in the dis tinctive heavy gage cabinet design can be used with forced circulating hot water, one or two pipe, steam vapor or vacuum systems. Heat regulation is by simple chain control damper. Free standing or recessed style 20 in. or 24 in. high, 6 in. depth, 20 to 64 in. length, ratings from 17 to 68.6 sq ft EDR (4075 Btu/hr to 16,464 Btu/hr). /!> in. copper tube--expanded into aluminum fins. Publication 600-1. Unit Heaters Horizontal Suspended Type Brown Heet Unit Heaters are available in capacities from 2,400 to 240,000 Btu/hr (100-1000 sq ft EDR) operating at 2 lbs steam pressure 60 F air entering. _ Hot water use is optional. Heat ing element consists of ) in. OD copper tubes expanded into alimiinum fins providing positive permanent mechanical bond. Publication 500-1. 1333