Document km0nNx8Lbkr5B2O75X153kdMD
Monscnto
Lnsal'le, Quebec.
FROM
Nov. lj 17o7
SUBJECT REFERENCE
Minutes of Meeting held between Mr. J. Hughes Spectroscepist at N.E. and Monsanto Personae] on Oct. IQ/67
AV-67-415
TO
To those present: Messrs
A . J. Parent K. Jongsma
e.h; Toombs G. Ringrose
n. Nar'oonne
n \j
Bias
St
A. Vend ette
J. Darby .y
K.F. Dixon
R. Trump
R. Beau-" sh
K. McCabe
A meeting was held to discuss Northern Electric ' s new procedure for acceptance of raw materials for electrical type applications. Mr. Hughes described two rapid methods in use for electrical pro perty determination. These methods are summarized as follows:
1- Rapid fusion of a thin film of resin (2-3 gram sample) with
subsequent immersion cf film in water. Haze development indi
cates poor electricals.
^
2- Slab test to .determine whether 26 week IR will pass. Compound is milled, molded and then subjected to high voltage. The ratio of current passage at the ine "minute interval and the 10 minute interval should be over 1 If The results are supposedly
comparable to both wire and slab tests.
We gave Mr. Hughes samples of compounds representing a questionable
lot,, jreturned by Canada wire (1068 B # 70224) and an Acceptable 106B
"lot, Of fOo^P. Their results confirmed Canada Wire's finding ST...The
Test's' took a total of 05 minutes and the results were as foilov:s:
N.E.
N.E
70224 70604
Av OJ 2X1012 _ -1 o 14 f'XlUJ--
V.R
Oak Avp. IR Reading
` ' ' 244
"600
isposltie '.order lfritv
ilure /
. T064
2400
1.47
* The results are in terms of a 0.31" coating on power cable.
Discussion
The test as indicated under 2, evidently shows good correlation
with the 26 week 'IR test and VR test^ . The reproducibility is
within 1$, which compares favourably with the 30$ reprcducibility
of the VR - IR results. N.E. can carry up to 100 of these tests
per day. Tne quantity of clend required ' per test, is 100 grams . The
applied voltage is 500 volts. Apparently no direct reacting is
involved, but the ratio is calculated after one and 10 minutes.
1C*
is> JU*
L
lUs-4, l* Fj
(70b0t)
t/j^,
DSW 587703
fJb
,
STLCOPCB4093039
Page 2
The time of measurement (usually 2-3 minutes) for the electrometer needle to go down is important. Slabs, cables and film can be tested and in such a way so that area in which problems occur are isolated.
Milling must be standardized as variation of 100^ of test result may occur.
ASTM and Government'approval is presently being requested by N.E. -
and may take one year.
.
/ An impending meeting of Monsanto personnel at N.E. has been
[ cancelled because of N.E.'s reluctance to expand upon details of test.'
'-until fully proved out.
.
.-
,P.S. 1- J. Hughes is an es-MCL employee at Ruabon.
2- *J. Hughes will probably give us the supplier of:
a) Electrical Model press with a sample of a molding
DSW 587704 STLCOPCB4093040