Document kb95roOjrQwK54ZMn0a24qZJ
Htxagon Laboratories
Vo
-7
February 14, 1961
Moo*anto CKomlcal Co. 800 N. Lynberg 81 vd. $t. Loult 66, MiHourI
Attention: Dr. Emmet Kelly
Door Dr. Kolly:
In reference to our roconl telephone conversation, I would Ilk* to further dltcuu the Incident wherein two of our plant personnel were exposed to hot Arochlor (1248) vapon generated by o broken pipe connection. For your Information and records the two men developed symtoms of Hepatitis as you predicted and were confined to a hos pital for approximately two weeks.
In view of the above experience which has given me considerable concern I felt lhat the matter dtould be brought to your attention. Since we ore dealing with a highly toxic material at high temperatures and since these failures cannot be prevented, it is felt that a more thorough and clearly written description of the hazards be described under Safety of Handling. Also the antidote or first aid treatment if any be Included. I certainly would be Interested In this Information If available.
I trust that this matter will be given your serious consideration to that other or new ueers are fully aware of the problem.
Thank you for your assistance in this Incident and would appreciate hearing your views on the above.
Very truly yours,
HEXAGON LABORATORIES, INC.
Chief Engineer hons 039413