------------------------------------------------------------------------------------------------------------- DAME OF OPERATION OR EQUIPMENT TYPE OF HOOD (dimension) Strip Drill #2 Down draft (5" x 6") Strip Drill #3 Flexible duct (A" diameter) Strip Drill #4 tl FACE VELOCITY PPM 800 600 It AIR VOLUME CFM 167 50 50 Strip Drill #5 ft 500 45 Avey Block Drill Table saw (Block) Block I.D. Grinder Enclosed and exhausted Flexible duct (4" dia.) 3/4 enclosed (13" x 7") ft 1200 BOO tt -100 500 Comments: 1. A total of five directions were suggested in Dr. Verma's report dated February 6,1973. Out of the five directions, No. 1 and 5 should be considered to be complied with. The company is working on the other three directions. Two additional directions are suggested in this report. 2. There is an immediate need for proper and improved local mechanical exhausts for the kneeders. 3. The "Lodige" mixer should be provided with adequate dust control measures to control the dust dissemination. h. Brushing and dry sweeping are still used to clean the equipment. j. The use of compressed air is widespread and frequent. This should stop immediately. The company should consider installing a clothes cleaninp station. o. The number of damaged bags should be reduced to a minimum. 7. The existing exhaust hood for the "Dual Saw" is not very effective A c on id arable amount of fibres escapes into the general area. SPNY 001353