Document kDyqq1jaz5edwDpb1nQ8XrOGV
o5
SPECIALTY PRODUCTS AROCLOR ENVIRONMENTAL PROGRAM
Bio-Test Tissue Analysis .
An inventory of all Bio-Test tissues held by Monsanto for PCB
analysis has been prepared as well as an estimate of those
retained by Bio-Test Laboratories. Analysis of all tissues
(muscle, fat, liver and kidney) from the first sacrifice (3
month exposure) of the two year chronic rat toxicity study
have been completed.
.
Customer and Plant Support Analysis
-
No. Of Samples
Sample Source
Sample Description
Status of Analysis
| >
11 !3
\ 2
-i 1 1
NCR (Dayton)
Plant effluent com posite '
Ameripol
Plant effluent com posite
J. F. Queeny
Plant effluent com posite (Feb. t Mar.)
Rogansky Feed Co. R-83
C. F. Mueller Co. Vermicelli
Completed
Completed
\
Completed
Completed Completed
/ \
/M
( '2
R. A. Kimerle/ CRD
-Goodyear Point Pleasant, West Virginia
Coagulated Anniston plant effluents
Plant effluents
Completed Completed
<
1
Kimberly Clark
Plant effluent
(Moraine Mill)
Completed
t 25
!
{
:8
Central Soya
Westinghouse Aquatechnics
Products associated with commercial chicken raising .
Treated Plant
effluents
"
B/25 Completed
Scheduled for Completion 4-30-71
Polychlorinated Terphenyls (PCT)
HUNS 042653
Hexane extraction of effluent water spiked with Aroclor 5460 demon strated that it is not a suitable solvent for quantitative extraction
C# -2-
.0
of PCTs from plant effluent samples. The recovery (50+1%) on duplicate samples was reproducible but much too low to be used for isolation of PCTs from water. Quantitative extractions of PCTs were obtained with either benzene or dichloromethane. The extraction recoveries using dichloromethane (99.0%) were calculated from UV absorption data. For benzene, total organic chlorine was determined using a sodium biphenyl-silver nitrate
titration procedure.
MCS 1043, MCS 1016, Aroclor 1221, Aroclor 1242, Aroclor 1254, and Arobromochlor 1232
The present SCAS tests on MCS 1043, MCS 1016, Aroclor 1221, Aroclor 1242, and Aroclor 1254, and Arobromochlor 1232 have been halted and the total residues from each unit isolated for detailed GC analysis.
Two new test units were started on MCS 1016 and the Aroclor 1142
distillation residue, at a 5 mg feed level and a 5 day time
cycle, in hopes of demonstrating differences between these materials.
In the 1st cycle, 58% of the MCS 1016 was lost and 53% of the
distillation residue. EC/GC analysis of samples from both units
did not show any isomeric alteration indicating that the initial
losses are due to a physical phenomenon, i.e., adsorption on the
glass, etc.
.
Aroclor 5460, Aroclor 5432, ARobrom 5465, and Hexabromobiphenyl
Current scheduling should allow sampling and analysis of these four SCAS units to start in the first or second week of May.
E. S. Tucker:db 4-29-71
HONS 0A2`>5'*