Oboes*vat- ions on a visit to the Zonolita plant, Calgary,
" "
IS-September l^bT;
''
N"
Both expanding machines were operating, One machine was producing normal Zonolita fill, whilst tha other wa3 producing the waterproof masonry fill. It was a warm day and all :no windows were open. The plant was very dusty, and considerable amounts of dust issued from various ^ cracks and openings in the machines. Most of tie dust appeared to have a fairly large particle size, and four test samples were wero taken from the atmosphere at various locations in the plant. Counts of the dust particles in these samples varied from 70,000 to 13i>,000 particles pir cubic foot having a diameter less than lOu (0,01 mm). It is the particlos less than 10(u in diameter which would be small enough to penetrate the lungs and cause the trouble mentioned by Dr.Siemens. Particle counts less than 1,000,000 per cubic foot(less than 10^ in diameter) are not normally thought to cause any trouble, A more detailed air sampling investigation with more sophisticated equipment appears to be necessary in order to define more accurately -he conditions prevailing in the plant. We hope to be in a position to do this in a few weeks time.
It was noted that a special mix known as 'Kono-Kote',
containing a fairly large amount of ground asbestos, ia
occasionally prepared, Asbestos i3 well known as the
cause of lung fibrosis, and the influence that the mi.v ing
of 'Mono-Kote' may have had is an unknown factor, We hope
to bo able to take air samples near the mixer next time
a batch of 'Mono-Koto* i3 prepared.
It is most important that dust respirators should be
worn wher any work is done with ground asbestos. It was
noticed that two respirators were available in the mixing
room, but these appeared to be dusty and in an unhygienic
condition, lb is advisable tha'; respirators should be
issued on an individual basis, and should bo kept clean
and covered when not In use.
A suitable for use throughout tha plant would be the
MSA 'Dustfoe' 66 or equivalent. Thi3 is a light respirator
approved by the U,S, Bureau of Mines as suitable protection
against fibrosis-producing dusts. Care should be taken
that the respirators should be properly fitted for each
individual. Proper maintenance of the respirators and
regular filter changes are important,
------ H,EuohwaId y-w -- ' -------