Document kDoyvxyExjagrQ5mBm1kdM8Qy
HONS 071672
Contents
PAGE 1 The Pydraut Air Compressor Fact Finder
1 How Compressor Fires and Explosions Occur
3 Pydraui Fire-Resistance
4 Pydraui AC-A Virtually Eliminates Valve Deposits
5 Converting To Pydraui Is Easy
6 Pydraui Provides Excellent Lubricating Qualities
7 Mixing Compatability
7 Pydraui Is Used As A Lubricant For Compressors Made By All Major Manufacturers
8 Safe Handling
i
HONS 071673
3
The Pydraul
Air Compressor
Fact Finder
. . . is designed to make the many facts about Pydraul1, fire resistant lubricants for air compres sors--Pydraul AC-A, Pydraul AC-A Winter Grade 28 and Pydraul 625A--easy to find. These satety lubricants for air compressors were specially developed to offer you:
Safety from Fire and Explosion Pydraul eliminates combustible mists and mini mizes carbonaceous residues -- greatly reducing the threat of compressor fires and explosions.
Lower Maintenance Costs Pydraul eliminates deposits on exhaust valves, in coolers and in piping. You save the costs of com pressor downtime and cleaning. Many compressor users find these savings alone justify using Py draul lubricants.
How Compressor Fires&
Explosions Occur
Every theory about the mechanisms of compres sor fires and explosions hold one idea in common: petroleum oils are directly involved.
Petroleum Oil Mists * Films Mist and accumulated films from petroleum oi) in compressor systems can, under a variety of con ditions, break down into combustible gases and carbonaceous residues that can ignite and pro duce an explosion, a receiver fire--or both. The U. S. Bureau of Mines* found that carbon deposits in air compressors lubricated with petroleum oil form a "carbon-oxygen complex/* Oxidation forms this complex, and accelerated by heat, this oxida tion process can lead to an explosion.
The Shortcomings of Safely Devices Safety devices do not completely eliminate fire and explosion possibilities. A study on "The Mecha nism of Explosions In Starling Air Lines/'* based on an exhaustive survey of compressor operations at 53 companies, reports that a stuck or leaking air check valve permits the engine being started to pack the section of line between the check end air timing valve with an explosive "oil residue-etr" mixture. A pressure wave will force this mixture upstream into the main air line--and coupling this with good flame propagation In the power cylinder, the condition is laid for explosion in the pipe sys tem.
Air line explosions and fires may even occur with out the engine being started or before the ignition is turned on. Carbon and rust particles m a "hot" air line, due to operating an overheated compres sor too long--hardly an improbable condition-- can become saturated with oii, and with the flow of starting air, can cause these oit-saturated par ticles to flame.
Explosion Tests t 1300 FBI The Walter Kidde Company, makers of fire extin guishing equipment, warns in a study* that users of high pressure air should guard against intro ducing a shock wave into high pressure lines by suddenly opening a plug cock in air compressor systems using petroleum oil. This report showed that in a 1-inch diameter tube, the inside welts filmed with oil. a sudden admission of air at pres sures above 1300 psi caused combustion.
How can you eliminate the conditions that eause fires and explosions in air compressors? Eliminate the source of carbon deposits, the basic cause of most air compressor disasters--petroleum oil.
Substitute fire- and explosion-resistant Pydraul.
t. "The Carbon-Oxygen Complex at a Poaalbla fnttietor ot
Explosion* and Formation ot Carbon Monoxide in Com* pressed Air Systems," by Bueeh. Berger, end Schranfc. Bureau of Minas paper R.I.44M. June 1949.
2. "The Mechanism of Explosions in Starting Air Linas," by Rldgway, Robert S.. Pafro/aum Refiner. June ISM.
3. "Oil Combustion Phenomena in High Pressure Air Sys tems." M. W Waibet. Wetter Kidde A Co.. Ine.. Report R-831. copyright 1952.
MONS 071614 1
TABLE 1
PYDRAUL AC-A
PYDRAUL AC-A
WINTER GRADE 2S
......' Cijtf Blu*U**T, * I.J0-U4 .V:.
0.1555
i
LyiscMirr-
ftatiilokn 100T;
*m-,;.ivV
jkmptm
BWi*iw.vi
t ........ 125'teW# .vnutfffi
... ... imjsu r. r* saSSlH'?'.'-* 65 SSU +m. MO
.
\
'
t
le^'iaMsss
j^'^M^SBPgBSga
.mrr. ' 00048
MOSS-
.
^iissa
Om BIH UquM
U8S-U2S 115 0.1555
85*56 5.9 to u 417.0 5SU 4unu S45SSU
60SSU +5*r. ISO
350T
7>7*F. 000045
(LSI aou
4001000
m
IU
Negligible.
45.0 Ne^lsAlo
CtoM * l*N* I.235-1-255 0.15 0.1555
21 Id 30 Ut02 132JSSU SI.3SSU IttSSU 45SSU --25*F.
2.03
350*F.
SWT. ooooii
133 1001
3M.000
41.0 NeffigrWt
COMPATIBILITY WITH METALS
Pydraul air compressor lubricants are compatible with all construction metals Including aluminum. In most operations, aluminum bearing surfaces will wear as long as any other metal surfaces lubri cated with Pydraul if they have been anodized.
TABLE 2--VAPOR PRESSURE
Temperature
Vapor Presaure mm Hp
X. F. PYDRAUL AC-A
PYDRAUL 625A
PYDRAUL AC-A WINTER GRADE
28
0 10 20 40 60 SO 100 150 200
32 50 68 104 140 176 212 302 392
J.b x 10-6 11.0 x 10 6
3.3 x 10-5 2.4 x 10-4 11.5 x 10-4 5.0 x 10-3 1.7 x 10-7 0.26 2.2
0.30 x 10- 1.1 x 10-6 4.0 x 10-6 3.8 x 10-3 2.3 x 10-4 1.2 x 10-3 0.55 x 10-2 0.13 1.4
5.5 x 10-fr 17.5 x 10- 50 x 10-
3.5 x 10-4 1.6 x 10-3 6.6 x 10-3 2.2 x 10-2 0.31 7.3
Vapor Comity 11.2 cumpwftsd lo value for air of one (1).
FIGURE 1--TYPICAL VISCOSITIES
_ PYDRAUL 625 A _ PYDRAUL AC A _____ PYDRAUL AC-A WINTER GRAOC 28
2 HONS 071075
*
Pydraul Fire-Resistance
Pydraul fire-resistant fluids and lubricants have worked in industry since 1951, providing many
millions of machine hours of fire-free operation. Never during these hours of machine operation has a Pydraul fluid contributed to a fire and
never since their introduction in 1954 has any Pydraul fire-resistant compressor lubricant caused a compressor fire or explosion.
FIRE-RESISTANCE TESTS OF
PYDRAUL AC-A,
PYDRAUL AC-A WINTER QRADC AND PYDRAUL USA
TEST
High Pressure Spray Teat AMS3150C end Federal Teat Method Std. 791. Test fluid sprayed at 1000 pel through orifice. pasting through flame of oxyacetytene torch. 6000*F.
RESULTS
Does not flesh or Ig nite up to 3% foot from orifice.
Atomized Spray Test (procedure
used by Factory Mutual Engineer ing Division). Test fluid heated to 140*F. sprayed at 1000 pel from
atomized cone type nozzle. A
torch Is passed through thie spray 2 feet and 2 to 0 tnchee from the orifice.
Local burning by toreh at 6 Inchas and 2 feet
from orifico. Flamoe --if^KUnguiehe hwmedlstely arhon torch re
moved.
Hot Manifold Test (Federal Teat Method Std. 791). Teat fluid drip ped on tube at 1300'F.
Dooo not flash or bum.
Molten Metal ignition Teat. Teel
fluid exposed to the surface of aluminum alloy at 1200*F., to leaf for spontaneous Ignition.
Does not ignite.
i
3 HONS 071676
1
Pydraul AC-A Virtually Eliminates
Valve Deposits
Compressor Data: 142 CFM, 6" LP Bore, 5" HP Bore, 5" Stroke, 870 RPM, 100 psi air
The photos compare exhaust valve deposits formed during individual 500-hour operations on two lubricants: a premium grade petroleum oil ... and Pydraul AC-A*. A glance at the photo of the valve lubricated with petroleum oil shows considerable carbon deposit build-up after 500 hours operation. The improve ment in the valve condition in the photo on the rioht is obvious--virtually no carbon deposits alter 500 hours operation with Pydraul AC-A. In the par ticular case, the compressor operator expects to get 7500 to 10.000 hours of service from Pydraul AC-A without shutting down--a 15- to 20-fofd in crease In operating time without a shutdown. Re sult: substantial maintenance savings in time and money--end virtual elimination of the fuel souree of most air compressor fires and explosions.
No photograph* availabia of Pydraul 625A and Pydraul AC-A Wlntar Qrada 26. but raaulta art at laaat idantical.
HONS 071677 4
Converting To Pydraul Is Easy
First, simply drain the petroleum oil and wipe the crankcase or lubricator.
Thoroughly clean the exhaust valves and inter stage equipment before filling the crankcase or lubricator with Pydraul. Pydraul will loosen car bonaceous deposits, varnishes and sludge. Unless these loosened deposits are cleaned from the sys tem. they could clog pipelines and components, requiring additional downtime and production loss. Once the valves have been thoroughly cleaned of potentially dangerous carbon deposits, Pydraul lubricants will keep them clean--and let compres sors run longer between maintenance shutdowns.
STANDARD CHECK FOR COMPRESSORS--Plas tic separator bowls. Not ail plastic separator bowls are suitable for Pydraul service. Certain plastics are "crazed" or softened when exposed to Pydraul. Bowls made of glass, brass, steel, and these plastics--polycar bonate, polyethylene, or nylon--are recommended for use with Pydraul. If you have a question re garding the resistance of a particular plastic, Monsanto will be happy to advise you.
Diaphragm valves. Pydraul lubricants have a sof tening effect on neoprene and buna N rubber diaphragms normally used for petroleum oil serv ice. These diaphragms should be replaced with butyl rubber, EPR (ethylene propylene rubber), fluoroelastomer, silicone or other compatible etaalomer materials resistant to Pydraul fluids. Dia phragm sheeting is available from normal sources of supply.
All diaphragms in unloading vatves or downstream control valves should be replaced at the time of changeover. Diaphragms In valving downstream from separator systems or drying systems need not be replaced at changeover time, but should be changed on a preventative maintenance schedule as soon as practicable after operation on Pydraul is begun.
For air compressors supplying air for instrumenta tion functions, mist eliminator systems are recom mended to remove lubricant mists and moisture from air streams. A Monsanto development, a Brink* mist eliminator is a particularly effective system, available from Monsanto in a series of lowcost mist eliminator systems to operate at all ca
pacities. For information on a Brink series suitable for your compressor system, write to:
Monsanto Enviro-Chem Systems, hie. 800 North Undborgh Btvd. St Louis, Mo. 83183 Telephone: (314) IM-ttM
(Joseph A. Brink)
SPECIAL CHECK FOR SPLASH-LUBRICATED COMPRESSORS
Crankcase paint. Pydraul air compressor lubri cants will soften and loosen some paints from crankcase interiors. These paint particles could block the lubricant passages. For this reason, it is a good practice to remove paint from crankcase interiors before Pydraul is added to the system. Standard paint removers are adequate for remov ing this paint.
SPECIAL CHECK FOR FORCE-FEED LUBRICATORS Sight-glass fluid. If a separate force-feed lubri cator of the type normally filled with water and glycerine is used, one of two changes it neces sary: either replace the sight-glass fluid with one heavier than Pydraul or insert a metal bobber in the sight-glass. Pydraut fluids are heavier than water or glycerine and will not rise through these standard sight-gfaaa liquids. Fluorochemicai 10V a clear liquid supplied by the Minnesota Mining and Manufacturing Company, has a higher density than Pydraul and is a completely satisfactory re placement.
Metal bobbers. The alternate to using Fluoro chemicai 101 Is to modify the sight-glass lubricator by inserting a simple metal bobber. The bobber is installed by draining the sight-glass liquid, remov ing the guide wire and inserting the bobber. Operation of the lubricator is then indicated by movement of the bobber with each stroke of the pump plunger instead of counting the drops as with guide wires. Bobbers ere available for either McCord, Manzell, or Lincoln Engineering lubri cators. Modification of the Madlaon-Kipp lubricator requires replacement of the entire sight-glass.
Vacuum-sight lubricators. Vacuum-sight lubrica tors require no modification for Pydraul usage.
5 HONS 071678
Pydraul Provides Excellent
Lubricating Qualities
TABLE 3 FALEX LOAD TEST
PASSING LOAD
Pydraul 625A
Pydraul AC-A
Pydraul AC-A Wlntar Grada 28
4250 4025
4175
TABLE 4 FALEX WEAR TEST
WT. LOSS, PIN (mg.)
WT. LOSS, BLOCKS (mg.)
Pydraul 625A
1.1 5.8
Pydraul AC-A
0 0.5
Pydraul AC-A Wlntar Grade 2B
0.6
0.9
DROP SIZE
Drop size of a lubricant is important to determine an adequate lubricant injection rate to insure proper compressor lubrication. The rate of lubri cation is controlled by noting the drops per unit of time.
The drop size for the fluids tabulated below were determined by noting the number of drops formed at room temperature (75*?.) on a 1 mm I.D. by 3Vi mm O.D. glass tip. (Larger or smaller drops will result If different sized tips are used.)
FluM
Medium weight petroleum oil Pydraul AC-A
Drape par 1 cubic eaadmatar
33 I 30
When installing new equipment, it Is best to Mart with an increased lubricant teed rate and reduce
this rate by successive increments. Inspection ol cylinder walls and valves will indicate the proper degree of wetting.
TABLE 5 TIMKEN
OK LOAD (lbs.) FILM STRENGTH
<pi>
Pydraul 625A
Pydraul AC-A
Pydraul AC-A Winter Grade 26
30 11.700 45 15.100
24 8,600
TABLE 6 SHELL FOUR-BALL WEAR
(167*F,, 1 hour, 630 rpm., mm scar diameter)
STEEL ON STEEL
PYDRAUL S25A
PYDRAUL AC-A
PYDRAUL AC-A WINTER
GRADE 28
10 kg 40 kg
STCCL ON BRONZE
10 kg
0.23 0.60
0.46
0.33 0.67
0.48
0.42 0.66
0.43
6 HONS 071679
Mixing Compatibility
pydraul AC*A, Pydraul AC-A Winter Grade 28 and pydraul 625A are completely miscible in ail pro portions with competitive synthetic phosphate otter lubricants.
t
Pydraul Is Used As I A Lubricant For
Air Compressors Made By
j All Major Manufacturers
New air compressors of most types and sizes pro duced by major compressor manufacturers can be manufactured tor lubrication with Pydraul. The
manufacturers listed (below) have manufactured compressors equipped for Pydraul, upon specifi cation of the buyer, for over ten years. Many com pressors have operated on Pydraul lubricants con
tinually with exhaust air temperatures of 350F. Pydraul Is also used to lubricate cylinders in com pressors operating at pressures over 4500 psig.
American Messer Corporation
Atlas Copco Bury Compressor Company
Carrier Corporation
Chicago Pneumatic Tool Company Clark Brothers Company,
division of Dresser industries Cooper-Bessemer Corporation DeLaval Steam Turbine Company Gardner-Denver Company
Ingersoll-Rand Company
Joy Manufacturing Company
Kinney Manufacturing, division of The New York Air Brake Company
Norwalk Company, Incorporated Schramm, Incorporated Worthington Corporation
7
r
HONS 071680
Safe Handling
There has been no reported case In many years of service to Indicate any special health hazard with Pydraul air compressor lubricants. However, as with all specialized industrial fluids and lubricants, certain precautions are advisable.
Animal toxicity screening studies indicate Pydraul AC-A, Pydraul AC-A Winter Grade 28 and Pydraul 625A may be considered only slightly toxic from the standpoint ot accidental ingestion or skin ab sorption. It does not appear to have any signifi cant potential for skin or eye irritation. Because these fluids have excellent solvent properties, re peated or prolonged skin contact could lead to de tatting and drying of the skin; thus reasonable personal hygiene practices are recommended to avoid prolonged and repeated skin exposure.
It Pydraul fluids are splashed or sprayed into the eyes, moderately severe pain and irritation may
result. There Is no evidence to show Pydraul causes permanent eye tissue damage. Eyee should be thoroughly flushed with water and the workman referred to a physician. To relieve irritation, physi cians have used 1% pontocaine solution, as well as the ophthalmic cortisone acetate solution.
Vapor Inhalation. At room temperatures, there is no vapor inhalation hazard from Pydraul fluids. Although there has been no problem with high concentration of vapors, inhalation of vapors at high temperatures should be prevented.
If the compressed air is to be used for air line masks, respirators and other inhalation equipment, it is always recommended that a commercial filter cartridge for air-supplied masks be Incorporated in the compressor air line to remove any foreign matter. This is good industrial practice lor any compressor fluid or lubricant.
8 HONS 071681
DISTRICT SALES OFFICES ALL DIVISIONS
AKRON, OHIO 44313
260 Springtide Drive Montrose Development Park Tel. (216) 666-4111
ATLANTA, GEORGIA 30326
Lenox Towers East 3400 Peachtree Pd. N. E. -- Suite 1711 Tel. (404) 577-2260
BOSTON, MASSACHUSETTS 02149
Everett Station Tel. (617) 387-5010
CHICAGO, ILLINOIS
3158 Des Plaines Ave. Des Plaines. Illinois 6001Q Tel. (312) 296-6688
CINCINNATI, OHIO 45206
1601 Madison Road Tel. (513) 751-6707
DETROIT, MICHIGAN 48235
500 Northland Towers East Tel. (313) 357-0910
HONOLULU, HAWAII 96812
205 Pacific International Bldg. 677 Ala Moane Blvd.. P. 0. Box 3824 Tel. (808) 531-2744
HOUSTON, TEXAS 77027
1301 Post Oak Tower 505 1 Wastheimer Road Tel. (713) 621-9550
LOS ANGELES, CALIFORNIA 90022
6670 E. Flotilla St. Tel. (213) 723-2492
NEW ENGLAND AREA
Hydrocarbons 8 Polymers Div. 730 Worcester St.. Indian Orchard. Mass. 01051 Tel. (413) 788-69T1 Pteatic Products & Resins Div. P. O. Box 2130, Springfield. Mess. 01101 Tel. (413) 788-6911
NEW YORK. NEW YORK 10017
277 Perk Avenue Tel. (212) 922-4111
ST. LOUIS, MISSOURI 63166
800 N. Lindbergh Blvd. Tel. (314) 694-1000
SAN FRANCISCO BAY AREA
27JO Le/eyette. Sente Clare. Calif. 95052 Tel. (408) 243-0414
SEATTLE. WASHINGTON 98121
2112 Third Avenue Tel. (206) 622-4203
WILMINGTON. DELAWARE 19803
2005 Concord Pike, Fairfax Tot. (302) 658-6531
Additional District Office*
arm maintained by:
Agricultural Oiviitun
ALLENTOWN. PENNSYLVANIA 1S1Q4 Park Proleeeronat Building 3200 Hamilton Siraat T*l. (215) 437-5471
DECATUR. ILLINOIS 62523 207 Decelur Proleaaipnel Building 363 South Mam Straet Tot (217) 423 603T
DES MOINES. IOWA 50310 312 Merle Hoy Tower Tot. (SIS) 276 8503
FREMONT. NEBRASKA 68025 150 South Main Snoot Tot. (402) 727-1230
INDIANAPOLIS. INDIANA 46205 Suite 216. 4000 Meedowe Drive Budding Tot. (317) 647-9140
KANSAS CITY. MISSOURI 64133 701 Blue Ridge Tower 4240 Blue Ridge Boulevard Tel. (616) 353-8060
LULINC. LOUISIANA 70070 P. 0. Box 174 Tel. (504) 764-6263
MANKATO. MINNESOTA 56001 111 Maditon East Tel. (507) 387-3406
MEMPHIS. TENNESSEE 36104 303 Union Plate Budding 1635 Union Avenue Tel. (901) 276-7611
MUSCATINE. IOWA 52761 P. 0. Box 473 Tel. (313) 263-1331
Hydracarbgnt A Palymaxe QMeiet-Ug<i OH
EL DORADO. ARKANSAS 71730 Lion Oil Budding Tel. (501) 563-3111
JACKSON. MISSISSIPPI 35206 P. O. Bua 10937. Weetlend Station Ta) (601) 352-3646
N. LITTLE ROCK. ARKANSAS 72116 410 Wett 6th Street, P. O. Bex 6621 Tal. (601) 376-2437
MEMPHIS. TENNESSEE 38113 1023 Rivereide Drive. P. 0 Box 13246 Tal. (901) 940-4461
Organic Dimtttt (Robber leatremeau)
AKRON. OHIO 4431! 920 Brown Street, P. O. Box 2307 Tet. (216) 434-1962
flattie Predacti A Katina BMeton
EUGENE. OREGON *7401 P. 0. Box 1819 856 Seneca Roed Tet. (503) 342-7201
KENILWORTH. NEW JERSEY 07033 North Seventh St. A Monroe Ave. Tel. (201) 276-2900
Textiles Oiviaian
ATLANTA. GEORGIA 30303 Allente Merchandise Mart 240 Peachtree St . N. W. Tel. (40d) 677-2260
CHARLOTTE. NORTH CAROLINA 26210 6230 Pairview Road. Suite 400 Tel. (704) 364-0110
GREENVILLE. SOUTH CAROLINA 29606 McAlister Plata P. 0. Box 6564. Station B Tal. (603) 339-9171
NEW YORK. NEW YORK 10001 350 Filth Ava. Tal. (212) 866-5100
HONS 071682
MOMS 071683
Monsanto
"Nolhmf coAlamrt h*t**n it bt ctnifttH m
WARRANtllS AS TO INI MtNlSS OR MIRCNAN1 A|lttT V Of ANY PRODUCTS RITIRRI^ TO. na ttfinlff fl utitlMwy itwNt had*
all iiatiiliiy loi *<ii
Am m dtmaf?"
Monsanto Company / Functional Fluids / 800 North Lindbergh Blvd. / St. Louis, Missouri 63166
0770-16HM
litlio in U. S. A.