Document kDnOX3Dmd81MBeJ6BKz47jqXD

MONSANTO INDUSTRIAL CHEMICALS COMPANY Welcomes Mr. Wayne Peterson Mr. Duane Blough Mr. Ray Hurd CORNELL-DUBILIER CORPORATION Division of FEDERAL PACIFIC ELECTRIC St. Louis, Missouri August 3, 1972 HONS o^zo** INDEX SECTION I II III IV V The Need For PCB-Type Fire Resistant Dielectric Fluids (Excerpts from the Jan. 5, 1972 report by the National Industrial Pol lution Control Council - U.S. Dept. Commerce, Washington, DC A. Capacitors B. Transformers U.S. Government Interdepartmental Task Force Report, May l^t, 1972 entitled "Polychlorina ted Biphenyls and the Environment" A. Continued PCB use for capacitors and transformers is considered necessary B. Disposal of scrap capacitors by burial C. Disposal of scrap PCB fluid by in cineration Handling and Policing PCB Dielectrics A. ANSI Committee C107 guidelines for capacitors and transformers B. ASTM D-27, Methodology for sampling PCBs and analysis of water and air Purchase of Capacitor and Transformer Askarels A. By Cornell-Dubllier B. By Federal Pacific Electric C. Purchases Table I D. Prices Table II E. Pricing Characteristics Table III _ Summary of Monsanto's Actions to Meet the Electrical Industry Requirements and To Mini mize PCB Environmental Pollution 15 charts Q4420? mon$ PAGE 1 1-3 3-5 6 6 6 6 7 7 7 8 8&10 8&10 10 11 12 12 on SECTION I The Need For PCB-Type Fire-Resistant Dielectric Fluids (Excerpts from the Jan. 5, 1972 report by the National Industrial Pollution Control Council - U.S, Dept. Commerce, Washington, D.C.) HONS 04<t20a I. The Need For PCB-Type Fire-Resistant Dielectric Fluids (Excerpts from the Jan. 5, 1972 report by the National Industrial Pollution Control Council - U.S. Dept. Commerce, Washington, D.C.) A. The Need For PCB Type Dielectric Fluids In Capacitors 1. Widespread use of PCB capacitors PCBs are used in more than 90# of the electric utility (large power) type and smaller indus trial type capacitors made today. They are needed for safety, reliability and long life, and to achieve sizes compatible with equipment and Installation requirements. The principal types of PCB-impregnated capaci tors and their applications are high voltage power capacitors used primarily for power fac tor correction in the distribution of electric power; low voltage power capacitors Installed ln_ industrial plants at the load (typically large motors); ballast capacitors to improve the efficiency of lighting systems; and small industrial capacitors for power factor improve ment in such equipment as air conditioning units, pumps, fans, etc. Almost 80 million such capa citors are manufactured annually, most of them for flr3t-time use. Capacitors used in lighting and air condition ing applications contain 0.005 to 0.09 gallons of PCB per unit. The largest power capacitors contain about 6.7 gallons of askarel. The most popular size contains about 3.1 gallons. The National Electrical Code requires that any in stallation of capacitors in which any single unit contains more than 3 gallons of combustible liquid shall be in a vault like that required for transformers. During 1968, the last complete "normal" year for the electrical industry, the total amount of fire resistant PCBs used in capacitors was approximately 14.4 thousand tons. 2. Reliability, life and safety of PCB capacitors PCBs are thermally and oxidatively more stable than mineral oils and most other dielectric fluids. Discharges, which can occur in capa citors, are less likely to generate gases from askarels than from mineral oils. The-chemical stability of PCBs in the presence of capacitor MONS 044^09 tissue and plastic films and the favorable stress distributions between solid and liquid have made it possible to design low ' cost capacitors with a life expectancy of more than 10 years life In lighting applica tions and more than 20 years in electric utility applications. In each application the first-year failure rates are less than 0.2%. This level of life and reliability had not been achieved prior to the Introduction of PCBs. The relative non-flammablllty of PCEs signi ficantly reduces the fire hazard that might otherwise accompany those failures that re sult In rupture of the case. 3. Consideration of other dielectric fluids for PCB-type capacitors a) Mineral oil ' The single most important property of a liquid to be used In a capacitor Is Its dielectric constant (the ratio of its ability to store electrostatic energy relative to air). The dielectric constant of the capacitor-grade PCB (Aroclor 1242) is 5-85 while that of mineral oil Is 2.25. Reverting to an oil-paper dielectric system would increase the average capacitor volume (size) by approximately 600$, the weight by 500#, and the cost by approximately 400#. At the present levels of demand for capaci tor KVAR, there would be a shortage of elec trical grade paper and a shortage of capa citor factory facilities further tending to increase the cost to the utility, and ulti mately to the consumer. b) Castor oil The dielectric constant of castor oil Is 4.5 and this material is useful as an impregnant in D.C. energy storage capacitors. However, A.C. capacitors filled with this liquid have relatively short lives and are not very stable under A.C. discharges and in the presence of water derivable from the celluloslc paper. -2- MONS 044210 ) Dlbutyl Sebacate This ester Is especially useful in high frequency parallel plate capacitors because of its low, flat loss characteristics over a broad frequency range. In this type of con struction the liquid Is the sole dielectric material. When used in conjunction with paper this ester is also unstable. d) Silicone Fluids These materials have a dielectric constant of 2.7 and would generally be subject to the same disadvantages as mineral oil. 4. Monsanto developed Capacitor flroclor 1016 to achieve a higher degree of environmental compatibility. As the environmental studies indicated that the higher boiling (the higher chlorinated) PCB isomers persist in the general environment, Monsanto sub stantially removed these persistent components from commonly used capacitor Aroclor 1242. This Aroclor 1016 capacitor dielectric has the same fire-resistant rating assigned to Aroclor 1242 by the Underwriter's Laboratory. Replacement of Aroclor 1242 with Aroclor 1016 in capacitors Involved no handling, process nor capa citor design changes. This work done by Monsanto in collaboration with the capacitor Industry was culminated by universal adoption of Aroclor 1016 for capacitors in mld-1971. B. The Need For PCB-Type Dielectric Fluid In Transformers Because of the nonflammability of transformer askarel fluids, their vapors, and their arc-formed gaseous products, transformers filled with PCBs are free of fire and explosion hazards and may be used in locations where failures of oil-insulated transformers would pre sent a potential danger to life and property. Most of these transformers are located inside public, commercial, or industrial buildings; on the roof tops of such buildings or in close proximity to such build ings, and require no special enclosures other than what are necessary to prevent accidental hazardous mechani cal or electrical contact of persons with We equipment 3- MONS 044211 b) Furthermore, liquid-insulated transformers have a much greater overload capability. Many liquid-insulated units can sustain a 100$ overload for 8 hours and a 200$ over load for 2 hours. These transformers are able to maintain continuity of electrical service during periods of temporary mal function of related equipment. c) Some dry-type transformers are larger by . 10 to 30$ than comparably rated liquid in sulated units, and most are more expensive. d) Dry-type transformers are nolser by 5-10 dB than are liquid-insulated transformers. e) Open dry-type transformers, which are cheaper than sealed dry-type transformers, cannot be used in certain corrosive or hazardous atmos pheres, e.g. on furnaces or on electrostatic precipitators near hot stacks. 3. Other fluids The fire underwriters will not accept the use of oils, silicones and other flammable liquids .for indoor transformers. No currently available liquid which will replace askarels in existing transformers is known. -5MONS 044212 SECTION II U.S. Government Interdepartmental Task Force Report May 14, 1972 Entitled "Polychlorinated Biphenyls and the Environment" HONS 044213 IX. U.S. Government Interdepartmental Task Force Report May 14, 1972 Entitled "Polychlorinated Biphenyls and the Environment. This report is available from the National Technical Information Service, U.S. Department of Commerce, Springfield, Va. 22151. The task force included opera ting units of five Executive Branch Departments: Department of Agriculture Department of Commerce Department of Health, Education & Welfare Department of Interior Environmental Protection Agency These government agencies are fully appraised of Mon santo's voluntary actions to discontinue sale and supply of PCBs for all non-electrical uses. The Task Force Report states: A. "The use of PCBs should not be banned entirely. Their continued use for transformers and capacl- tors in the near future Is considered necessary because of the significantly increased risk of . fire and explosion and the disruption of electri cal service which would result from a ban on PCB use. Also, continued use of PCBs in transformers and capacitors presents a minimal risk of environ mental contamination. The Monsanto Company, the sole domestic producer, has reported voluntarily eliminating lta distribution of PCBs to all ex cept manufacturers of electrical transformers and capacitors." _ B. Disposal of Scrap Capacitors "Most capacitors presumably have been disposed of in landfills. FCB-contalnlng material burled in soil is not expected to migrate but should remain in place. In the past, many fluids containing PCBs have been disposed of In sewers. More appro priate means of disposal such as high temperature (at least 970C) incineration must be used Instead." C. Disposal of Scrap PCB Fluid Monsanto is one of several to provide proper high _ temperature Incineration and HC1 neutralizating facilities to completely destroy PCB liquids. Monsanto charges 3 cents a pound and shipping charges are to the sender's account. -6- rtoNS SECTION III Handling. and Policing PCB Dielectrics moNS III. Handling and Policing PCB Dielectrics A. The American National Standards Institute ANSI Committee C107 composed of a capacitor section and a transformer section, on behalf of all parties Interested In PCB dielectrics. Is scheduled to publish guidelines for hand ling and disposal of capacitor-grade askarels and transformer-grade askarels. B. PCB analysis Methodology developed by Monsanto and others Is In process of documentation at ASTM D-22 for sampling and analyzing of PCB from water and air. C. Need to Avoid Environmental Contamination While the continuing need for PCBs In closed elec trical applications is conclusive, the electrical Industry must well understand that continued use of these materials requires unusual.protective measures and exceptionally clean "house keeping". EPA plans to regulate the controllable sources of PCBs to the water environment. Pish and shellfish will be examined to reveal locations with high PCB content. The PDA guideline allows no more than 5 ppm PCB in the edible portion of fish. It Is not believed necessary to regulate PCBs In air, at this time. The Industry goal Is "zero" concentration of PCB In plant water effluent streams. However, it Is recognized that existing drain systems in (for example) capacitor manufacturing plants are prob ably contaminated as a result of past practices and PCB traces may continue to show up In effluent streams for some time. -7-' 0^ib SECTION IV Purchase of Capacitor and Transformer Askarels I IV. Purchase of Capacitor and Transformer Askarels A. Capacitor Aroclor As Cornell-Dubilier Is one of the early manufacturers of Aroclor capacitors, their Initial use of Aroclor 125^ must date back to the early 1930s. Over the past 20 years Cornell-Dubilier's use has ranged from 8.558 to 13.1# of the total annual amount of capacitor Aroclor used In the USA. The annual pounds used by Cornell-Dubilier has ranged from about 1 million pound rate in the early 1950s to the 2.5 million pound peak used in 1970, when the annual dollar volume was also a maximum, at $390,000. B. Transformer Askarel Federal Pacific Electric, located on the west coast, has been confined through the years to serving that market area. Accordingly their use has been relati vely small. The peak year was 1959 when Federal Pacific purchased *185,000 pounds of transformer askarel. This represents 13.1# of the total transformer askarel used that year, in the USA. Over the past several years Federal Pacific use of transformer askarel has ranged from one to two hundred thousand pound3 annually. With advent of the PCB pollution problem, recently. Federal Pacific at Milpitas, Ca. seem to have dis continued manufacture of askarel units. This may well deserve reconsideration as there is need for askarel transformers on the west coast where now few (perhaps only one) producer remains. C. Purchases (Pounds of Fluids) ) ! The recent purchases of askarel dielectrics by Cornell-Dubilier and Federal Pacific Electric are i i given in the attached Table I. D. Prices i The historical sales prices per pound for the askarel I fluids sold to Cornell-Dubilier and to Federal Pacific Electric are given in Table II. 1 -81 MONS 044218 E. Monsanto Dielectric Fluids Pricing Characteristics 1. Unusual price stability through the years until 1970. 2. Increases 1970-1972 fully accounted by fac tors related to the PCB-cnvironmental problem; see Table III. -9- 04<,21.9 HQNs TABLE I. Cornell Dublller, Purchase of Capacitor Aroclor Federal Pacific Electric, Purchase of Transformer Askarel (POUNDS) 1968 1969 1970 1971 6 months 1972 Cornell Dublller (capacitor Aroclor) 1,857,000 2,495,000 2,539,380 1,216,800 874,000 Federal Pacific Elec, (transformer Askarel) Totals 97,000 1,95^,000 170,000 2,665,000 106,968 2,646,348 235,400 1,452,200 20,220* 894,220 -10- Reflects rumored discontinuation of askarel transformers by Federal Pacific Electric at Milpitas, Cal. - m0NS Year 1953 1957 i960 1964 1$S6 1970 1971 1972 TABLE II. Historical Price of Capacitor Aroclor Sold T6 Cornell Dublller Hew Bedford, Haas. " Price Per Pound (Bulk) 14.0* Not Delivered 13.88* Delivered 14.98* Delivered 14.50* Delivered ' 14.95* Delivered 16.00* Delivered 18.00* Delivered 20.50* Not Delivered Product Aroclor 1242 Aroclor 1242 Aroclor 1242 Aroclor 1242 Aroclor 1242 Aroclor 1242 Aroclor 1016 Aroclor 1016 Price of Inerteen 70-30 Sold to Federal Pacific Electric Milpitas, Ca. Year Price Per Pound FOB Sauget, 111. _________ (Drums) CL/TL 1970 19.20* 1971 1972 21.50* 24.50* -11- (HONS 044221 Table III Monsanto Dielectric Fluids Pricing Characteristics Unusual price stability until 1970 even though ----- Cost Increases Labor Costs: Raw Materials: Indirect Fixed Costs: 197# Increase 20# Increase 41# Increase (1953-1972) (1953-1972) (1953-1972) (e.g. Capacitor Fluids Increased by only 7#, 1953-1969) Increase 1970-1972 due to: A. Successful development of Aroclor 1016 B. Loss of 45# PCB sales to other markets -- divisor loss C. Costs of Environmental Control Programs -- Incinerator Program Plant Clean-up -12- HONS 044222 SECTION V. Summary of Monsanto's Actions to Meet the Electrical Industry Requirements and to Minimize PCB Environmental Pollution -12- HONS t,7 7 l>*'0 o i' *OT o MONSANTO PRESENTATION TO FEDERAL GOVERNMENT PCD TASK FORCE . MAY 15, 1972 . OBJECTIVES 0 PROGRESS REPORT ON LABORATORY BIODEGRADATION OF PCB'S O RESIDUE ACCUMULATION STUDIES IN FISH, BIRDS AND HAHHALS O TO SHOW REDUCTION IJSl LESS BIODEGRADABLE PCB'S AS A RESULT OF MONSANTO ACTIONS ON SALES AND PRODUCTS SZ?r*rO SNOM o o MONSANTO PCB ACTIONS O PHASE-OUT OF PCB SALES WORLDWIDE IN ALL APPLICATIONS EXCEPT DIELECTRICS O CONVERSION OF DIELECTRIC FLUIDS TO MORE BIODEGRADABLE PCB'S o S3' MONSANTO PCB SALES IN U.S.A. (million pounds) * DIELECTRICS ALL OTHERS TOTAL 1969 37.0 30.0 67.0 1970 40.5 33.5 74.0 ' 1972 (est.) 32.0. -- 32.0 9 7 7 * ^ 0 SNOW QO O* o EFFECT OF. PHASE-OUT POLICY PCB SALES REDUCED IN U.S.A. BY 30 TO 33 MILLION POUNDS, OR 45% . o 9 &o I . o PCB PRODUCT CHANGES IN DIELECTRICS CAPACITORS 97% CONVERSION TO AROCLOR 1016 TRANSFORMERS ELIMINATION OF AROCLOR 1260 Czto o I ii ooo / DEGREE OF BIODEGRADATION OF PCB'S BASED ON DATA PRESENTED O TRANSITION IN BIODEGRADATION OCCURS AROUND PENTA-/HEXA-CHLORQBIPHENYL O DISAPPEARANCE OF ALL HOMOLOGS BELOW HEXA-CH LOROBIPHENYL OBSERVED . O PENTA- AND HIGHER PCB DETERMINED BY SPECIFIC GLC/MS TEST METHOD I 6 7 2 ^ 0 SNOW HONS 0 4 4 2 3 0 is)- O I oo PCB'S USED IN CAPACITORS MAJOR PCB USE PERIOD AROCLOR 1254 AROCLOR 1242 1930-1952 1952-SEPT. 1971 AROCLOR 1016 OCT. 1971 % PCB (PENTACHLORO- AND HIGHER 77.0 9.0 1.1 % PCB (HEXACHLORO- AND HIGHER 29.0 1.0 0.1 MONS O'*4* 2 3 1 oli- oo CAPACITOR FLUIDS WHY CONVERT TO AROCL.OR 1016 ? O 9-FOLD REDUCTION IN PCB'S OF PENTACHLORO- AND HIGHER O 10-FOLD REDUCTION IN PCB'S OF HEXACHLORO- AND HIGHER ' O MINIMUM INDUSTRY TESTING REQUIRED G\e,. O G ' CAPACITOR FLUIDS ' WHAT IS THE EFFECT OF.AROCLOR 1016? U.S. CAPACITOR FLUID SALES (1972):-20 M LBS. IF AROCLOR WAS l PENTACIILOROAND HIGHER PCBs WOULD BE* % HEXA CHLOROAND HIGHER PCBs WOULD BE* 1254 1242 1016 15/400,000 pounds 1/800,000 220/000 5/800,000 pounds 200,000 20,000 "THIS DOES NOT MEAN AMOUNTS OF PCB ENTERING THE ENVIRONMENT HONS 0 4 4 2 3 2 v* - O ' o o swo'rf \ o OJJrfot o> WHAT IS CAPACITOR FAILURE RATE ? INDUSTRY SOURCES CITE : 0.02-0.2X per year o IF CAPACITOR FAILURE RATE IS 0.2% PER YEAR (WORST CASE) o PCB ESCAPE TO THE ENVIRONMENT* IS -- ALL PCB HOMOLOGS PENTA CHLORO- AND HIGHER HEXA CHLORO- AND HIGHER AROCLOR 1242 40,000 pounds 3,600 400 AROCLOR 1016 40,000 pounds 'm , 40 ASSUMES U.S. FLUID SALES OF 20 M LB./YEAR MQNS 0 4 4 2 3 4 ooo PCB CHANGES IN .. TRANSFORMER FLUID APPLICATIONS % O AROCLOR 1260 BEING PHASED-OUT NOW O INCINERATION OF SCRAP PCB'S - 1971 NOTE: ASKAREL (PCB) TRANSFORMERS ARE TIGHTLY SEALED UNITS o44ruo>" SNOW WHAT IS FAILURE RATE IN LIQUID TRANSFORMERS INDUSTRY SOURCES CITE: UNDER 0.22 PER YEAR* *ALL LIQUID TYPES - MINERAL OIL MD PCB. IF ASKAREL (PCBI TRANSFORMERS FAIL AT 0.2%/YEAR fHOW MUCH PCB IS AFFECTED' ALL PCB HOMOLOGS 24,000 lbs. (ESTIMATED PCB TRANSFORMER FLUID SALES IN U.S. 12 M LBS./YEAR) INCINERATION FACILITIES AVAILABLE, NOT ALL THESE AMOUNTS HILL ENTER ENVIRONMENT. L ARUUNIS Civ O I O o MONSANTO'S PRESENT PROGRAM TO PREVENT ENVIRONMENTAL POLLUTION BY PCB'S O NO MORE SALES WORLD-WIDE EXCEPT APPROVED DIELECTRIC USERS ------------- ** O RESTRICT OVER 97Z CAPACITOR FLUID SALES TO AROCLOR 1016 ONLY . O ELIMINATE AROCLOR 1269 FROM TRANSFORMER FLUIDS t ' O CONTINUE INCINERATION FACILITIES FOR SCRAP PCB'S 1 O ENCOURAGE DIELECTRIC INDUSTRY THROUGH ANSI ' C-107 TO ENFORCE STRICT ENVIRONMENTAL CONTROL OVER PCB'S Monsanto has attempted to act responsibly as concern about the effects of PCBs on our environment developed. Based on cur rent knowledge about PCBs, the approach presently being taken by the U.S. Government and the continued need by our customers In the electrical Industry for PCB-containing dielectric fluids, Monsanto Intends to maintain Its policy of remaining a supplier of these materials for dielectric uses. However, should changes In present conditions occur, Monsanto may find It appropriate to revise Its policy. MQNS 044239