Document kD96NjawoORog1KZXE0vdb2a0

E. I. ou Pont de Nemours & Company Wilmington. Oelaware '9898 engineering DEPARTMENT c 'ir.dso SAftTT l F1IE PMTOr.uH J Ef TO, APR 7 1972 am ________ r* 71 s i *ito> tilii11 xis;i a i s 1 1 I ! I I i I I I II April 6, 197| DR. CHARLES F. REINHARDT HASKELL LABORATORY The attached letter from Felix Stein of the University of Pittsburgh regarding asbestos sampling technique will undoubtedly have some bearing on our future procedure. Engineering Standard S4T, ''Control and Measurement of Asbestos Dust", is in final typing and should be issued in the near future. If the procedure developed by Haskell does not include Stein's i references from OSHA you may wish to consider them. In any case would you let me have your thoughts on the matter so that we may answer Stein in behalf of the Construction Division? The sending of two unused filters with each sample seems like an expensive requirement. Thanks for your assistance. CONSTRUCTION DIVISION Ingo Zsise Asst. Division Safety Engineer IZ:rbw Attach DUP U1 1037 DU 055030 from: mr. Felix oteiu oo2 r.ecxier ur. nstsuurgn, ra. ip22u To: Engineering department, IiOuYiers aauc-r*g dilair^ton, le. Constr. oiv. ^aiety uifice i j-J>L- I 2 Gentlemen: New guide lines have been recently published by tne Occupational Safety and Healtn Administration regarding, tne sampling and analysis of air-borne asbestos fleers. For your information a copy of tne new aetnod is enclosed. The caanges as outlined in tne enclosed puoiication are froa tecnnical standpoint amor ana therefore 1 believe that tne results ox tne asoestos fiber counts will not ce significantly different as determined oy either aetnod. However, tne newly recommenced procedure is legally tne correct uniform way to monitor your environment in tne plant. The new sampling rate is 2.0 1pm witn an open face filter ana with eacn oaten oi samples two filters snould be submitted to me whicn were subjected to exactly tne same handling except that no air was drawn tnrougn them. In regard to tne analytical procedure used by me, the change is only in tne magnification for tne microscopic fiber analysis. The new recommended magnification is lower tnan tne one 1 used so ar. This will result in a somewhat lower fiber count since some of tne tninnest fibers will ce no longer visible for me. Please let me know if and when you wish to change over to tne new procedure. 1 am ready at any time to maxe tne change and I will be glad to assist you if you have any questions regarding tne sampling. With best regards 0UP 111*038 DU 055031 6SG 3 OCCUPATIONAL SAFETY C. HEALTH RErQRTE SAMPLING DATA SHEETS FOR HEALTH HAZARDS PREPARED BY THE OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION OSHA SAMPLING DATA SHEET NO. 1 Substance: Carbon monoxide. S:a-dard: 29 CFR 1910 92 b, Table G-l, of August 13. 1971 S-liour time-weighted average: 50 ppm (55 mg/mJ). Sampling ltjitipinent: ill CO meter, (Portable. Hapcabi: - reagent type) - IV.I.nv directions. (Print jr;. Method) (21 Certided or N10.SII .pproved detect.: tubes end i hand operated pump (not squeeze bulbl may be used for eempltatiee purposes. (Sccand-ry Method) Inals nail Procedure: (l) Direct reading instrument based go measurement of heat of reaction produced by oxidation of CO to C02. f-cihiw instructions. td) Detector tubes are read for length of stain, strokes pump are noted end appropriate corrections made for . oure (or altitude) abate 5CC0 feet (I5C0 ml. The ..as jic not to be used when below 0 degree F (-IS C) above 125 degrees F (52 C). 2.~,-.'.7ie Period: it) Il'pcaJttc: maximum feasible number of readings '.! be averaged to determine average exposure. Time .red dependent on variability and cyclical nature of ctn'cuev 12) Detector tubes: direct reading, ienath-of-stain t bi*-es (certified on MOSH approved) may bq' : i : c. mpuancc pu'rpo:es."Taneast one sample]pcr_ ' ' :.\.n*per exposed''',vorKer or "close'group of * ' ' i i an KTiour day Tnofe frcquenT"samptings' per '* n-.-fetted. especially for exposures over 50 ppm. > ' ' 'N'cnt samplings (one per hour is considered the * --TvcniiirtmumBfr). ------------- * ---- .........< 0:'~-r Situations: 1 u ns above 500 ppm (10 x TLV) for any ' arc considered to be an imminent danger. ' ! f fjtirtn; 1 'iii'ms above 150 ppm (3 x TLV") for a total 1 ' '< more in an 8-hour workday are considered h l-iunn: ' '"''"ns above 50 ppm, but below 150 ppm for '' ''"'-hied average are considered nonsenous ' * ** *^"'liitinn: Standard 29 ChR tOIOSSa-a, ] Ceae, .z.r ' . 3-hour tinic-wcigiucd avcr.ga*. 5 fibers per r.t greater than 5 microns in length. Excursion limit*: 10 fibers per milliliter, up minutes m an hour for up to 5 hours per a-iiour 2u Unprotected or improperly protected w^.-.v posures. Analytical Method: Fibers counted ai 4G0-450 magnification. u;.rg contrast illumination, with scmpie rncumea viscosity solution of memoranc tilter material. Sampling Equipment: Personal sampling pump plus Mdlipore tv pe A A (..!*. (37 mm. 0.8 micron pore size). Face cap is reraced . filter used open face during sampling. Sara;u-, a- *,,:q l.m. Sample Size: Minimum penod of 15 minutes for aval cat:;;, excursion limit. Several samples of up to A l-.au:> : evaluation of S-hour average. Samples w.th a :s;~ depostt may be too heavy to count. Compare with a filter. Heavy concentrations of visible dust in the air t. to 500 fibers/ml) may require short sampling penocs only 5 rmnutes, or less. Blanks: With each batch of samples submit two filters wb are subjected to exactly the same handling js for '.. samples except that no aat is drawn through them. La these as blanks. Shipping: The cassettes in which the samples are collected be shipped tn e suitable container, designed ta r----- damage tn transit. Imminent Danger Situations: Generally not applicable. Serious Violation: 5.1 or more fibers per ml. greater than 5 mterens length, for an unprotected or improperly protected e er. for an 8-hour time-weighted average, except ter cert proven excursions as noted m the emergency st.r.da which may raise the 8-hour time-weighted avcr.ge t.j fibers per ml. Summons Violation: Not applicable. / De Minimis Violation: Not applicable. V.MPLING DATA SHEET NO. 2 . OSHA SAMPLING DATA SHEET NO. 3 Substance- Crystalline silica. Occupational Safety & Health Reporter o~ DUP 1111039 DU 055032