Document kD12xDmR0JNrjBy5KgaonXJeE
ES-36C6
cc:
C. F . Reinftardt
F. A. Bowe r A. M. Kaplan
HASKELL LABORATORY
October 18, 1984
J. R. GIBSON CR&D HASKELL LABORATORY
RESPIRATOR WORKPLACE PROTECTION FACTORS FOR ASBESTOS (Haskell Laboratory Report No. 462-84; MR-5557-001)
SUMMARY AND BACKGROUND
Workplace protection factors for elastomeric and single use naif-face respirators were measured during asbestos removal operations. The operations^consisted of asbestos removal from a ceiling (fire proofing) and removal of pipe insulation. The use of water/surfactant solutions to spray fire proofing and insulation resulted in conditions of high humidity for indoors operations. Out-of-doors operations were also under high humidity conditions since light rain occurred on two of four days of sampling. Temperatures for both operations were in the 65-35F range.
The respirators were used in the context of a respirator program that followed the guidance in 29 CFR 1910.134 and ANSI Z88.2 (1980) including proper respirator selection and fit testing. A total of seventeen volunteers participated in the study. One or two workplace protection factors were determined for each respirator for which the fit test had been passed.
The respirators tested were:
One successfully fitted elastomeric facepiece respirator chosen for comfort from six respirators (MSA Comfo II and Survivair 2000 brands - small, medium and large sizes). These respirators were tested using dust, fume and mist and high efficiency filters.
Each of three disposable respirators successfully fitted (3M 9910, 3M 8710 and American Optical R 1050).
A successfully fitted North 7700 elastomeric facepiece respirator, chosen from the small, medium or large size facepieces.
DUP 0947094
-1-
DU 038374
In addition two workplace protection factor measurements were made for a self-contained breathing apparatus operated in the pressure-demand mode.
Results show that all respirators tested, reliably provide workplace protection factors of ten dr greater, except the AO RIO50, which reliably provides a protection factor of five or greater, based on estimates~of lower 5th percentile. These results are consistent with information supplied to the OSHA asbestos record by Los Alamos National Laboratory which reported on the.penetration of asbestos through respirator filter media.
Results for the self-contained breathing apparatus suggest that it may not provide appreciably better protection than the two better disposable respirators and the elastomeric facepiece respirators, though it presents a considerable stress and hazard of falling because of it's weight and awkwardness. Myhre et al.^2^ and Raven^ have shown that pressure-demand respirators do not maintain positive pressure inside the facepiece when workloads are increased from rest conditions. This may explain, in part, why the pressure-demand and self-contained breathing apparatus did not provide superior protection.
PROCEDURE
Prior to testing, each person was trained in the selection and fit testing of respirators using the National Paint and Coatings Association Training Program^4). Each was then fit tested using the saccharin fit test^ . Fit test results are given in Table V. Respirators selected for use and vendors are listed in Table I.
Two individuals were also trained in use of a pressure-demand self-contained breathing apparatus. Fit testing was not done, as it is not required for pressure-demand equipment per the ANSI Z88.2 (1980) standard.
During sample collection, each participant was observed continually to ensure that the sample train remained intact and did not interfere with the respirator seal on the face, and to note occurrences which might have affected respirator performance, such as movement of the respirator on the face. The participants were very busy-with their work activities and soon ignored the presence of the researchers.
AIR SAMPLING AND ANALYSIS
To determine the workplace protection factors, concurrent samples were taken from inside the respirator (in-mask) at nose level and outside the respirator at the lapel (lapel). Closed-face Glasrock (#1505) cassette filter holders fitted with half inch extenders and probes developed by NIOSH'5' were used for both the in-mask and lapel samples. The sample probes are specially designed to minimize the loss of particulates. The cassettes contained 0.8 um, 25mm cellulose ester filters.
- 2-
DU 038375
OUP 0947095
The sample trains were calibrated before and after taking each sample using a mass flow meter. The mass flow meter was calibrated against a bubble flow meter at the beginning and end of the study. A flow rate of 2 Lpm was used for the in-mask samples. Lapel samples were taken at 0.5-1.0 Lpm to avoid overloading.
Samples were collected for a one- to two-hour period. Each sample represented a single wearing of the respirator.
Fiber counts were done per NIOSH method P&CAM 239^ (phase contract microscopy), except that the triacetin/acetone mounting method was used as described in NIOSH method 7400'' . Counting was done according to the P&CAM 239 rules (the "A" counting rules in method 7400). Five hundred fields were counted for in-mask samples to increase analytical sensitivity. All analyses were done by one counter who participates successfully in the American Industrial Hygiene Association's Proficiency Analytical Testing quality assurance program. Concentrations were calculated from the actual number of fibers counted (even if fewer than 50 fibers were counted) per the formulas in the NIOSH method.
NIOSH method P&CAM 239 reports a coefficient of variation of 0.12 which applies to lapel samples in this study. We estimate that the coefficient of variation for the in-mask samples is 0.4 at the median in-facepiecc concentration and fiber count (Table III) .
Transmission electron microscopic analyses were also done on selected samples to obtain data on small fiber penetration and size distribution.
All field and analytical data are retained in the MR-5557 f ile.
SAMPLING AND ANALYSIS METHOD VERIFICATION
In-mask sampling required use of closed-face filter cassettes. We used Glasrock #1505 25mm filter cassettes which have a unique tapered design for the outlet and a half inch extender which improves the deposition patterns'8 . To minimize sample loss, the NIOSh' probe was used to withdraw in-mask samples.
To eliminate possible bias, the same closed-face/probed cassette was used for both in-mask and lapel samples. To document whether concentrations determined from closed-face/probe cassette sampling differed from open-face sampling, twelve area samples were taken using both methods. Results are compared in Table II with Student's t and Variance Ratio tests 9 . The two sampling methods were found to give similar results with no significant bias or difference in precision.
-3-
DU 038376
DUP 0947096
iMi.t.5.a.L..BiiM8iSBiMtBittMin. iiCiin-fril-iaaiaaim
I.
H
RESULTS AND DISCUSSION
Transmission electron microscopic analyses were done on four lapel samples by Electron Microscopy Service Laboratories, Inc., Camden, New Jersey. The resultant distributions of fiber diameters and lengths are shown in Figures 1 and 2. Fiber diameters and lengths covered a wide range.
The overall median concentrations of fibers for in-mask, and
lapel samples are given in Table III. The median number of
fibers counted for in-mask (500 fields counted) and lapel (<100
field counted) samples are also given in Table III.
~
Cumulative distributions, geometric means, geometric standard deviations, best estimates of 5th percentiles and lists of workplace protection factors are given in Figures 3 through 8 for each respirator. The distributions of workplace protection factors were found to be approximately lognormal for all respirators studied. Therefore, logs were used for the plots, geometric means are reported as the proper measure of central tendancy and geometric standard deviations are reported as the proper measure of variability. Best estimates of 5th percentiles represent the workplace protection factors that most (95%) respirator users are expected to obtain from each respirator.
Distribution plots and geometric standard deviations include variability from the sampling and analytical method as well as
from the workplace protection factors. The unavoidable inclusion of the sampling and analytical variability in the plots results in best estimates of 5th percentiles which are conservative (lower than actual). This should be considered in evaluating results.
Workplace protection factors were determined for a selfcontained breathing apparatus for two individuals. Results are reported in Table IV.
Table v gives geometric means, geometric standard deviations, best estimates of the 5th percentile, and ratios of participants passing the fit test for each respirator studied. A
Bonferroni * test for differences (p=0.05) was done and results
are given in Table V. Workplace protection factors for the 3M 9910 were found to be significantly higher than those for the AO R1050. No other significant differences were found. The importance of doing a fit test is apparent from the fit test results in Table V.
The relatively low results for the AO R1050 are likely due to poorer filter efficiency for asbestos, reported by Dr. Ortiz of Los Alamos National Laboratory^1'.
-4 -
DU 038377
DUP 0947097
HKiBegMaaai3iijg[ffiBBSgaa
SajifclJBiili,
The unexpected comparability of the results from the 3M disposable respirators, and elastomeric facepiece respirators with both dust, mist and fume filters and high efficiency filters may be explained by several factors. First, because the filter efficiency is high F^99.9%), the limiting factor in performance of the respirators is likely face fit, not filter efficiency (except for the AO R1050 as noted above), since the same fit test was used to select good fitting respirators for the study, comparable face fit results would be expected, in addition, the researchers noted a tendency for elastomeric respirators to slip around when some wearers' faces became wet with the water/surfactant spray. This did not occur with the disposable respirators because their fibrous material of construction clung to the skin.
It is particularly noteworthy that the workplace protection factors for the self-contained breathing apparatus were not superior to the better disposable and elastomeric respirators. Myhre ^ and Raven 3' have shown that at workloads exceeding approximately 35% of maximal aerobic capacity pressure inside the facepiece of pressure-demand type respirators does not remain positive with respect to the surrounding atmosphere. This would provide an opportunity for airborne asbestos to be drawn into the facepiece.
The volunteers who wore the self-contained breathing apparatus complained of stress and discomfort due to its weight and bulk. Movement and balance were difficult and one volunteer almost fell from a step ladder as a result. Based on their observations, the researchers believe that routine use of self-contained breathing apparatuses for asbestos removal would likely result in injuries, in view of the large amount of climbing involved. Certainly, acceptance will be much poorer than for the other respirators studied, due to discomfort which would discourage respirator use.
Transmission electron microscopic analysis results were also used to determine workplace protection factors for thin fibers (Table VI). Results for small diameter (<0.2um) fibers do not appear to differ from those for large diameter (>0.2um) fibers, for 5 um or longer lengths. Thus, results for fTbers visible with the phase contrast method (>0.2um diameter) appear to be representative of those for smaller diameter fibers for the 3M 8710 and 9910, and for elastomeric respirators with dust, fume and mist and high efficiency filters.
CONCLUSIONS
1. All respirators tested provided protection against asbestos. The American Optical R1050 disposable respirator reliably provided workplace protection factors of 5 or greater. The 3M 9910, 3M 8710, and elastomeric half-face respirators with both dust, fume and mist and high efficiency filters reliably provided workplace protection factors of 10 or greater. -5-
DU 038378
DUP 0947098
2. Use of higher efficiency filters did not appear to improve the workplace protector factors of the elastomeric respirators.
3. Workplace protection factor measurements for a pressure demand self-contained breathing apparatus were not significantly higher than those for the better disposable and elastomeric respirators. Comments from the test volunteers and observations indicate that acceptance of the selfcontained breathing apparatus would be poorer than that of the other respirators tested. In addition, it presents a significant risk of tripping or falling, where removal work requires climbing ladders and working from scaffolding.
4. Transmission electron microscopic analyses suggest that for fibers longer than 5 um, the overall workplace penetration of small diameter (<0.2um) fibers is not higher than that of larger diameter fibers for the 3M 8710 and 3M 9910 disposable respirators nor for elastomeric respirators with dust, fume and mist or high efficiency filters.
ACKNOWLEDGEMENTS
The valuable collaboration and participation of Thomas J. Nelson in this study, and the perserverance and thoroughness of James E. Henry in doing microscopic analysis are gratefully acknowledged. Special acknowledgement is also due Robert L. Frye, C. Norman McLean, the study volunteers, and numerous other at the Kingston, Ontario site and the Potomic River site for their excellent cooperation and assistance.
The assistance of James M. Kayser, James C. Piner, James E. Henry and Susan S. Mileti in doing the workplace studies is greatefully acknowledged, as is the peer review of Edwin C. Hyatt, Earle P. Shoub, and Charles E. Billings.
REFERENCES
1. Ortiz, L. W. et al.: "Interim Report: penetration of Respirator Filters by an Asbestos Aerosol." May 2, 1984 (Los Alamos National Laboratory).
2. Myhre, L. G., R. D. Holden, F. W. Baumgardner and D. Tucker: Physiological Limits of Firefighters. Unclassified Report #ESL-TR-79-06, AFESC, Tyndall AFB, Florida (June 1979).
3. Raven, P. B. et al.: "Physiological Response to 'PressureDemand' Respirator Wear", Am. ind. Hyg. Assoc. J. 43(10):773-781 (1982).
4. "Guide to Respirator Fit Testing" (1981), National paint and Coating Association, Washington, D.C.
-6-
DU 038379
DUP 0947099
5. Liu, B. Y. U. et al.: "In-Mask Aerosol Sampling for Powered Air purifying Respirators", Am. Ind. Hyg'. Assoc, j. 45(4 ):278-283 ( 1984 ) .
6. (J. S. Department of Health, Education and Welfare: NIOSH Manual of Analytical Methods, Second Edition, Volume I (April 1977 )
7. National institute for Occupational Safety and Health, Method 7400, February 15, 1984.
8. Adams, M. J. et al., "Cassette Extenders: Effects on Chrysotile Fiber Deposition and Concentration Measurements", Presented at the American Industrial Conference, May 24, 1983.
9. Snedecor, G. W. and W. G. Cochran: Statistical Methods, 7th Ed., Iowa State university Press, Ames, Iowa (1980).
Report by:
STEPHEN W. DIXON SECTION SUPERVISOR
INDUSTRIAL HYGIENE
Approved by:
A. MICHAEL KAPLAN MANAGER - FIELD SERVICES
SWD/tac/3.52 Date Issued: October 18, 1984 Attachments: Table I-VI, Figure 1-8 Number of pages in this report: 21
DUP 0947100
7 DU 038380
an
aaaas
Respirator Name Survivair 2000
Comfo II
3M 8710 3M 9910 AO RIO 50 North 7700 Scott Air- Pak
TABLE I Respirators Studied
Type
Elastomeric (silicone rubber) with dust, fume and mist and high efficiency filters
Elastomeric (neoprene) with dust, fume and mist and high efficiency filters
Disposable with nonadjustable staps
Disposable with adjustable straps
Disposable with nonadjustable straps
Elastomeric (silicone rubber) with high efficiency filters
Self-contained breathing apparatus, pressure-demand
Vendor U.S.D. Corp.
Mine Safety Appliance Co.
3M Company
3M Company
American Optical Company North Company
Scott Aviation
DUP 0947101
HLR 462-84
8DU 038381
ISgMiiilB&raiStta EilBBBSU
TABLE II
COMPARISON OF ASBESTOS SAMPLING METHODS (OPEN-FACE VERSUS CLOSED-FACE WITH PROBE)
Parameter Mean
Value
2.2 fibers/mL - open face filter cassette 2.3 fibers/mL - closed face cassette with probe
Standard Deviation probe
0.264 fibers/mL 0.286 fibers/mL
open face cassette closed face cassette with
T Statistic*
1.28
Variance Ratio**
1.17
Data
Open-face cassette:
1.9, 1.9, 2.0, 2.1, 2.1, 2.1, 2.2, 2.2, 2.2, 2.2, 2.3, 2.9
Closed-face cassette: 2.0, 2.0, 2.0, 2.2, 2.3, 2.3, 2.3, 2.4, 2.4, 2.4, 2.5, 3.0
* 1.28 is less than a comparison t statistic of 1.78 (p=0.05). Therefore, the means do not differ significantly.
** 1.17 is less than a comparison F statistic of 2.69 (p=0.05). Therefore, the variances (precision) of the methods do not differ significantly.
DUP 0947102
HLR 462-84
9DU 038382
ii HI
TABLE III
MEDIAN ASBESTOS CONCENTRATIONS AND COUNTS FOR WORKPLACE PROTECTION FACTOR STUDY
Concentrations Inside Respirator Outside Respirator
Counts Inside Filter Outside Filter
0.006 fibers/mL (8 HR. TWA -^ 0.003)*
2.6 fibers/mL (8 HR. TWA ^1.3)*
9 fibers 130 fibers
No more than four of eight work hours were spent doing
asbestos removal. Therefore, a factor of 0.5 (4 HRS/8HRS) was applied to concentrations to estimate 8 HR TWA concentrations.
DUP 0947103
HLR 462-84
10 -
DU 038383
TABLE IV
WORKPLACE PROTECTION FACTORS FOR SELF-CONTAINED BREATHING APPARATUS (PRESSURE DEMAND)
Workplace Protection Factors::
400 880
Geometric Mean: 620
DUP 0947104
HLR 462-84
- 11 -
DU 038384
TABLE V
COMPARISON OF WORKPLACE PROTECTION FACTORS FOR SEVEN RESPIRATORS
Respirator
Number of Measurements
Workplace Protection Factor
Geometric Mean (Geom. S.D.)
Ratio Passing Fit Test
Lower 5th Percentile
3M 8710
18
3M 9910
14
AO RIO 50
7
Elastomeric/Dust,
Fume and Mist Filter
17
Elastomeric/High Efficiency Filter
14
North 7700 High Efficiency Filter
14
Self-Contained Breathing Apparatus
2
310 (5.3) 580 (4.2)
52 (4.2) 240 (6.3)
94 (3.0) 250 (6.9)
6 20
15/17 14/17
4/6 Not Tested
Surv.-14/16 MSA-1/2 15/15
Not Tested
20 55
5 12
16
11
`Based on a Bonferroni test' 1 at a 0.05 level of significance only the 3M 9910 and AO R1050 differed.
HLR 462-84
O c -o
12 sg
oU!
DU 038385
TABLE VI
WORKPLACE PROTECTION FACTORS FROM TRANSMISSION ELECTRON MICROSCOPIC ANALYSES
Respirator
Workplace Protection Factor
Fibers Exceeding 0.2 um
All Diameter Fibers
Diameter and 5 um Length* Exceeding 5 um Length
3M 8710
3M 9910
Survivair 2000 with Dust, Mist and Fume Filter
Survivair 2000 with High Efficiency Filter
3 30 47 28
21
120 41 29
19
*Those which would be counted by the standard phase contrast microscopy method.
HLR 462-84
- 13 -
O c 0 too $-A aO>
DU 038386
, eP
FIGURE 1 - FIBER DIAMETERS
DIAMETER
&
IF51 p
& A-juJL
^vv-aW^XV^.V'-' votww.vv
k,,,','^Vk.^*\'!*!*'.?Vv'1 v*>v\*S1 'i\'*'.VV\^So\,"','*VSv v\ V* %v\fc. % \>\ss*'i,**%,'v*1fc,'^S VjrV'T\^sr'JTy'.r^T\^Vi' v\v-.V.\Vv.*
P
o o HLR 462-84
ooo
o K)
o CN
o*--
sa38u jo aaawriN
14 -
P
o
o c "0
S
$_i
DU 038387
ilifiililliliiliii
liiiilMri
e 3 o
oI--I
FIGURE 2 FIBER LENGTHS-
E
3
J.1,1 \ *i
>W\S"--NSs-N^Wv>\NN^W.>\V->\\\',?\>`NW\\>W'SN `NNS'v%W^ i'** wy\'vV \\\w1' * *
3
CE-i >a4
i
3
oo
ooo o
o o o cs o o
o IO TT fo N
snaau jo HaawnN
HLR 462-84
- 15 -
DU 038388
DUP 0947108
Figure 3 - Workplace Protection Factors for 3M 8710 Respirator
Cumulative Distribution: (Lognormal)
DUP 0947109
Geometric Mean: 310
Geometric Standard Deviation: 5.3 Best Estimate of 5th Percentile: 20
Data: 7.4, 15, 61, 110, 110, 180, 200, 310, 400, 420, 430, 1000,
1000, 1100, 1500, 1600, 1800, 3200
HLR 462-84
- 16 -
DU 038389
Figure 4 - Workplace Protection Factors for 3M 9910 Respi'rator
Cumulative Distribution: (Lognormal)
DUP 0947110
WPF
Geometric Mean: 580
Geometric Standard Deviation: 4.2
Best Estimate of 5th Percentile: 55
Data: 94, 110, 150, 150, 170, 280, 550, 630, 710, 1300, 2400, 3000,
3700, 5600
HLR 462-84
- 17 -
DU 038390
Figure 5 - Workplace Protection Factors for AO R1050 Respirator
Cumulative Distribution: (Lognormal)
DUP 0947111
Geometric Mean: 52
Geometric Standard Deviation: 4.2
Best Estimate of 5th Percentile: 5
Data: 9.7, 26, 28, 38, 52, 75, 970
HLR 462-84
- 18 -
DU 038391
Wiitgiisit^* --rrflts^tagaa
Mir rjelliliii Mlisaig
Figure 6 - Workplace Protection Factors for Survivair 2000 and MSA Comfo Halfmask Respirators with Dust, Fume and Mist Filters
Cumulative Distribution: (Lognormal)
-< H -- r " -- CD co O ID "0>
DUP 0947112
Geometric Standard Deviation: 6.3
Best Estimate of 5th Percentile: 12
Data: 15, 24, 45, 46, 47, 74, 88, 140, 190, 370, 480, 1000, 1100
1100, 1800, 4100, 4200
HLR 462-84
- 19 -
DU 038392
l."g,r-`) Sr^Sj^feer- aSMtoaittk > l.
i
ngure I - Workplace Protection Factors for Survivair 2000 and MSA Comfo Halfmask
Respirators with High Efficiency Filters
Cumulative Distribution: (Lognormal)
-< H 1-- -- 00 > CDO 30 "U"
DUP 0947113
Geometric Standard Deviation: 3.0
Best Estimate of 5th Percentile: 16
Data: 12, 28, 32, 42, 65, 85, 110, 120, 140, 160, 160, 220, 220,
780, 7900*
HLR 462-84
Removed from plot analysis, as an outlier. - 20 -
DU 038393
Figure 8 - Workplace Protection Factors for North 7700 Halfmask Respirators with High Efficiency Filters
Cumulative Distribution: (Lognormal)
DUP 0947114
Geometric Mean: 250 Geometric Standard Deviation: 6.9
Best Estimate of 5th Percentile: 11
Data: 12, 20, 36, 60, 74, 110, 260, 350, 400, 1000, 1900,
2000, 2400, 3100
HLR 462-84
- 21 -
DU 038394
Mj F-'T ftMtiMffgEWFw--
- riHrtrifcziM;::
Mtit>l .g^i?Slgl-^l:t>tt^
Darrell K. Mattheis
Organization Resources Counselors, Inc
1625 1 Street, JvVV Washington, DC 20006 202-872-1080
DUP 0947118.001
DU 038395