Document k99RB5prkvOdb9ybLo8DY3GO
steam boiler illustrated
The A-5 oil-fired boiler is designed for installation in large homes and small to medium-size apartments and commercial buildings. This big performance boiler has been engineered specifically for oil operation and is available as a boiler only in a full range of eight sizes for hot water or steam application, with gross l = B = R output ratings of 261,000-830,000 Btu hr range. The A-5 is built for long-lasting efficiency and easy, low-cost installation. Vertical flue design reduces section weight, speeds heat circulation; unique tankless hot water heater adapts to meet varying domestic requirements; rugged cast iron sections assure long, dependable serv ice; wet base construction eliminates need for special base, keeps floor cool, optional pre-east combustion chamber saves on installation time.
The A-5 boiler is unmatched in its ability to meet a wide variety of domestic hot water needs. A unique tankless heater arrangement lets you match expanding domestic hot water requirements (from 4 to 16 gpm) by the inser tion of extra tankless water heaters into A-5 center sec tions. No need to install a bigger boiler or separate water heater to handle expanding hot water requirements. A special copper manifold assembly, pre-fabricated to cut installation time and cost, connects multiple heaters in parallel. Special center sections, with heater opening, are supplied at no extra cost on all A-5 boilers specified for tankless use. This special A-5 tankless heater ar rangement also permits the use of split systems to serve different domestic hot water needs. For versatility and flexibility in meeting domestic hot water needs, the
A-5 is the answer.
2 00231
oil-fired boilers
1- -matches jacket and has removable front panel for ready access to burner and controls; arch-type openings to provide ample air for combustion and circulation.
2- -permits convenient flame view ing; simplifies burner and control adjustment while boiler is firing. A 1/3-inch pipe tap is provided for draft test purposes.
3- -built into the front of the boiler; provides for easy accurate adjustment of sec ondary air.
4- -4-inch supply (top) and 2V2-inch return (bottom) located in both front and back sections, eliminate need for headeron largest steam assembly.
5- -aluminized steel construction per mits smaller flue pipe sizes; makes A-5 readily adapt able for gas firing.
6- -internal tankless type with finned copper tubing. Unique arrangement permits flexibility m meeting domestic hot water requirements ranging from 4 to 16 gpm.
7- -connects multiple water heater in parallel and is pre-assembled forquick installation.
8- -are ruggedly constructed of cast iron and feature vertical flue design with large 7-inch top nipple port. Off-center location of nippie port speeds up circulation; projecting studs and horizon tal bars extract maximum heat from combustion gases. Sections are water tested at 125 psi (2V2 times rated capacity of relief valve). Accessible from left side for cleaning.
9- -heavy glass fiber insulation prevents wasteful heat loss, keeps jacket cool.
10- -high-temperature, pre-cast refractory combustion chamber-provided for all assemblies-heats quickly and evenly.
11- -smartly-styled of sturdy steel in sparkling gray finish with modern radius corners.
12-
-provides extra heat-
absorbmg bottom surface and increased water con
tent. Waterways completely surround combustion
area, extend beneath boiler, keep floor cool.
AMERICAN STANDARD
00232
A-5 ratings
numbers
water
steam
g. i wa. s 1=B=R output water & steam
(Btu/hr)
net 1 - B = R ratings
water (Btu/hr)
steam (sq. ft.)
steam (Btu/hr)
l=B=R burner
capacity (gph)
chimney
size height (inches) (feet)
water content (gallons)
water bailer
steam boiler
A-504-W(T) A-505-W(T) A-506-W(T} A-507-W(T) A-508-WIT) A-509-W{T) A-510-W(T) A-51 l-W(T)
A-504-5(T) A-505-S1T) A-506-SiT) A-507-S(T) A-508-SIT) A-509-SIT) A-510-S(T) A-5U-S(T)
261.000 346.000 426,000 508.000 568,000 668,000 748.000 830,000
227.000 300,900 370,400 441.700 511,300 580,900 650.400 721.700
816 1C82 1332 1588 1838 2088 2338 2594
195,800 259.600 319,600 381.100 441,100 501.100 561.100 622,700
2 55 3.30 4 00 4 75 5.55 6.30 7 00 7.65
8 x 12 8 x 12 12 x 12 12 x 12 12 x 16 12 x 16 12 16 16 16
15 20 20 20 25 25 25 30
57 7 66 7 75 5 34 5 33 4 102.3 111 3 120.2
45 6 52 4 59 3 66 1 72 9 73 3 86.6 93.4
Net l = B = R ratings shown are based on a piping and pick up allowance of 1.333 for steam and 1.15 for water Amencan-Stanoard should be consulted before selecting a boiler for installations having unusual piping and pick up requirements.
Note; "S" denotes steam: "W" denotes hot water; "T" denotes unit with tankless heater section(s).
optional control sets for A-5 boiler units
control set
control function
no. 1 steam
no. 2 steam
no. 3 gravity water
no. 4 forced water
no. 5 forced water
no. 5-Z forced water
unit without domestic hot water
unit with year-round domestic hot water. Duitt-m tankless heater
unit without domestic hot water, immersion control
unit without domestic hot water
umt with year-round domestic hot water, built-in tankless heater, using circulator one no. 5-Z control set is required for each zone in addition to the first zone which is controlled by no. 5 control set.
description
thermostat, Pressuretrol
thermostat, Pressuretrol Aquastat ccerating control
thermostat, Aquastat limit control
thermostat, Aquastat limit and circulator control thermostat. Aquastat limit, reverse and operating control, circulator relay thermostat, relay
sample specification for A-5
Contractor shall furnish and install, as indicated on plans. oil fired boiler(s) having a firing rate of ........ gph
and an I = B = R gross output of............Btuh. Boiler(s) shall be constructed of cast iron in accordance with A.S.M.E. requirements for low pressure heating boilers and bear the A.S.M.E. symbol. Each section shall be factory tested at 2-2 times maximum working pressure of 50 lbs. for water. Boiler(s) shall have l = B = R ratings. Boiler(s) shall be com posed of cast iron sections with vertical flues. Manufac turers will furnish boilers with an aluminized steel canopy.
Water or steam trim as required. Oil burners shall include controls as herein described. (Note: include description of controls as required and other burner features and com bustion chamber as desired.)
Boiler shall be equipped with tankless heater(s) having a
rating of
. gpm. If more than one heater is required
to meet requirements a copper manifold factory assembled
will be installed by the contractor as recommended by the
manufacturer to connect the heater in parallel arrangement.
A-5 oil-fired boilers are designed and built to comply with the American Society of Mechan ical Engineers' Code and bear their approval symbol. Ratings have been approved by the Institute of Boiler and Radiator Manufacturers.
00233
oil-fired boilers
dimensions and tappings
ciean-cut access door
bent of boi'er
-F-
4 ' :oc flow tapping'
*7
fop flow tapping
___ ^
3Hj < top view *3*4
Ai.ntiro mats. 3: zR-
3`-iR
r?iS'
T 3*-i I ^--// - 22 Via
boiler
number
number of sections
A-504 A-505 A-506 A-507 A-508 A-509 A-510 A-511
4 5 6 7
8
9 10
H
number and size or tappings
flow (in.)
return (in.)
(2)-4 (2)-4 (21-4 (21-4 (21-4 !2!-4 (2)-4 (2)-4
(4)-2Vz (4]-2Va (4)-2i 2 (4)-2Vj (41-21/2 (4) -2 Vi (4)-2Vj (4).21/2
A
161/2 21 251/a 30 341/2 39 43V2 48
B
13>/4 16*4 16% 16% 163'i 16% 163-4 16%
dimensions (inches)
cD
E
9 lll'z
9%
9 111/2
9%
10 12
10
10 12
10
10 12
10
12 13 1 0 13
11 11
12 13
11
F
151/2 20 241/2 29 33V2 38 42Vz 47
Q flush jacket
22% 27*fc
313/8 36% 407e 45V8 49% 54%
jacket extension
477b
52*8 567/a ` 613-a 657a 70^8 747a 793 8
assemblage of sections
boiler number
A-504 A-505 A-506 A-507 A-508 A-509 A-510 A-511
arrangement of sections from front of boiler (with tankless heater opening)
1 2 3 4 5 6 7 8 9 10 11
FX CT CT BX FX CT CT CT BX
FX CT CT CT c BX FX CT CT CT c c BX -- -- -- -- FX CT CT CT c c C BX -- -- -- FX CT CT CT CT c C C BX -- -- FX CT CT CT CT c c c C BX -- FX CT CT CT CT c c c c c 8X
arrangement of sections from front of boiler
(less tankless heater opening)
1 2 3 4 5 6 7 8 9 10 11
FX c c BX FX c c c BX FX c c c C BX -- -- -- -- -- FX c c c C c BX -- -- -- -- FX c c c C c C BX -- -- -- FX C c c C c C C BX -- -- FX c c c c c c c C BX -- FX c c c c c c c c c BX
FX-front connecting section
CT-center section with tankless heater opening
C -center section without tankless heater opening
8X-back connecting section
control tappings
location
size
on boiler (inches)
F 2% G V4 H% J V2 K% L%
steam
low water cut-off pressure limit control operating control, tankless heater pressure gauge not used not used
control used
water
4f p . |
not used
JV\L
temperature limit control
not used
combination altitude gauge and thermometer
operating control, tankless heater reverse acting control
Note: 2-inch blow-off m back section. 2-mch safety or relief valve on top of back section
r * VER!CAK| v. j i AN DAk.J
00234
no. 530 tankless heater ratings
boiler number
number of heaters
ratines* (gpm)
A-504--A-511 A-504--A-511 A-505--A-511 A-503--A-511 A-510--A-511
i 2 3 4 5
4 7 10 13 16
Gallons of water per minute raised from 40'F to IWF with 20Q'F boiler water temperature.
The above table shows the recommended number of heaters to be used with each boiler and the ratings attained if more than one heater is connected in parallel. Additional heaters can be added if the heaters are serving different systems and it is not likely that heaters will all be in use at the same time.
No. 530 tankless heater available for single purpose or multiple parallel hook-up. Copper manifolds (illustrated below) for two, three or four-heater parallel arrangement furnished with No. 530 heater if specified.
Provision for tankless heater is available when specified. If suffix letter "T" is added on order to unit or boiler numbers, the following maximum number of center sections with heater openings will be furnished.
boiler or unit number
number of openings
A-504-T
A-505-T A-506-T A-507-T
2 3
A-508-T A-509-T
A-510-T A-511-T
Note: Additional openings can be specified on order. Cover plate for water heater openings will be furnished if specified on order, at added charge for "T" type units and boilers. Cover plate is available with 2" tapping for connection of external water heater.
tankless heater piping
Note: Single arrangement or any com bination of the above manifold piping arrangements can be used. Water heat ers are assembled in boiler starting with the second section from front of boiler. Heater cover plates are marked '`steam" and "water." When installing in a steam boiler the word "steam" should read at the top. when installing m a water boiler, the word "water" should read at the top.
`rent
of
DQiler
1 'eater manifold oiomg
00235
minimurr piping recommendations
oil-fired boilers
boiler number
A-504 A-505 A-506 A-507 A-508 A-509 A-510 A-511
gravity
supply (in.)
return (in.)
2Vz 2 Vi (2)-2 (21-2 (2)-2Vi (2)-2Vi (2)-2Vi (2)-2Vi
2 Vz 2Vi (21-2 (2)-2 (2)-2Vi (21-2 Vi (2)-2Vi (2)-2Va
forced
supply return
(in.)
(in.)
lVz 1 Vi 22 22 22 2 Vi 2 Vi 2Vi 2VZ 2ya 2Vi 2Vi 2Vz
boiler number
A-504 A-505 A-506 A-507 A-508 A-509 A-510 A-511
riser (in.)
3 3 4 4 (2)-3 (2)-4 (21-4 (2)-4
header (in.)
--
--
--
--
4 4 4 5
equalizer (in.)
2 Vi 2Vi 2 Vi 2Va 2 Vi 2 Vi 2Vi 2y2
return (in.)
IV. IV. 1V 1 Vi lVi iy* 2 2
optional combustion chamber dimensions
Heat lib-O-Rator molded refractory combustion chambers
fire brick refractory combustion chambers
A-504*
A-505 through A-511
A-504
A-505 through A-511
i lo J*w_
sectional view Chamber number 14-A
Heat lib-O-Rator refractorycombustion chambers are standard equipment on
units; optional with boiler only.
boiler number
A-505 A-506 A-507 A-508 A-509 A-510 A-511
sectional view
Heat Lib-O-Rator
chamber number
15-A 15-AA 16-A 16-A 17-A 17-A 17-A
A (in.)
15Vi 20 21Va 21Va 27Va 27Vi 27Vz
. -i to
ris 8i/2 JT__ T_
:occU'
sectional view
bailer number
A-505 A-506 A-507 A-508 A-509 A-510 A-511
A (in.)
14Va 18 20 22 24 24 26
B (in.)
18 18 22 22 22 22Vi 22Va
PSl AMERICAN STANDARD
00236
oil-Tired boilers
m N0 758 2 Per 2 5 7;
AMERICAN STANDARD
PLUMBING / HE AT INC
P O BOX 3003, NEW BRUNSWICK, N. I. 08903
00237