Document k963707a7a4joDVRyaXNY6aZO

Healing Systems Burners, Oil Herco Oil Burner Corporation Lancaster, Pa. The Herco Line--established since 1925 includes burners ranging from small resi dence units to burners suitable for large industrial applications. Herco Oil Burners are listed as approved by Underwriters' Laboratories, Inc., for Commercial Stand ard CS75-39. Write for de scriptive liter ature. Herco P - 50 and' P-35--The P-50 effi ciently han dles the re quirements of industrial, commercial and large residential instal lations requiring oil burning capacities of 9.00 to 20.00 gals, per hour. The P-50 is equipped with long-hour duty } H.P. motor with built-in microswitch for thermal overload protection; 9J4 in. x4 in. multiple blade Sirocco fan; twin nozzles. The P-35 provides excellent perfor mance for installations with requirements of 3.00 to 7.00 gals, per hour. The P-35 is equipped with long-hour duty Jfj hp. motor with built-in micro switch for thermal overload protection; 6 in. x 4 in. multiple blade Sirocco fan. Standard equipment on each of these Herco P models includes: latest type posi tive pressure pump; mid-point grounded transformer; electrode porcelains guar anteed for 60,000 volts. Mercoid Magnetic Valve (K-20-2)-- Optional on Herco P-50, this valve cuts off oil flow to nozzle and permits operation of fan for sufficient time to eliminate gas from combustion chamber. Herco LV 1-2-3--Capacities range from .75 to 7.00 gals, per hour. All three LV models are equipped with longhour duty motors with built-in micro switch for thermal overload pro tection. Mercoid "Vlsaflame"--Standard on all LV models, this light-actuated control shuts off burner within 45 seconds in case of ignition failure. (Standard controls are available on LV models if desired). Herco "Thrifti-Fier"--Standard on all LV models, the "Thrifti-Fier" permits hot gases to travel slowly through the boiler so that maximum heat is delivered to all heating surfaces. WRITE FOR FREE LITERATURE P-60 Measurements. LV Measurements. TABLE OF DIMENSIONS (In Inches) A--Bottom of flange to top of burner (Minimum).. A--Bottom of flange to top of burner (Maximum). B--Overall width.......................................................................... C--Center of homing to end of motor............................ D--Center of bousing to end of pump............................. E--Overall length (Minimum)............................................. E--Overall length (9' tube)................................................... F---Depth of bousing................................................................ G--Length of tube....................................................................... H--Diameter of tube................................................ ............. I--Bottom of flange to center of tube (Minimum). I--Bottom of flange to center of tube (Maximum). P-3S P-50 LV-1 LV-2 13 15 18 17 %9% 8i/4 25'/4 2IVe rA16% 9 l29>/ it iofyt. 1030 '(7* tube) LV-3 w/f i1i8Vi ft 24 15 9 150% 12 Heating Systems Burners, Oil H. C. Little Burner Co. Head Office: San Rafael, Calif. Branches In Principal Cities Fully Automatic Oil Burning Floor Furnace These low cost units are factory assembled, including ail controls, ready to hang in floor. Easy installation, no basement needed. Natural draft vaporizing burner, auto matic operation, with electric ignition and thermostatic control. Inexpensive to operate. Listed by Underwriters' Laboratories for No. 3 oil (27 4- Diesel oil). Two sizes: No. 70-42--47,250 Btu output (22 in. wide x 28 in. long x 44 in. high; No. 100-42--75,000 Btu output (22 in. wide x 40 in. long x 45+ in. high). Natural Draft, Automatic, Vaporizing Burner Natural draft vaporizing burner specifically designed for No. 3 oil (27+ Diesel oil) and listed by the Under writers' Laboratories. Model shown (with controls atr tached) is fully automatic, with electric ignition (no pilot light) and thermostatic control. Manually operated models, which do not require electricity, are algo listed for No. 3 oil. Seven sizes: 1.45 qts. to 2% gal. per hour. Aquatherm Water Heaters Economical operation and ample capacity for all domes tic requirements. Aquatherm "30" has 28 gal. storage, 40 g.p.h. recovery rate, is 19 in. wide x 21 in. deep x 56 in. Aquatherm ''60" has 60 gals, storage, 160 g.p.h. recovery, is 24+) in. wide x 36 in. deep x 68 in. Both units listed by Underwriters' Laboratories for No. 3 oil. Coil Water Heater For camps, auto courts, apartments orsmall hotels. Uses separate hot water storage tank. Also makes excellent boiler for hot water installations in home, heating. Two sizes: No. 150--106,960 Btu output, * 150 g.p.h. (80? rise); No. 250--160,440 Btu output, 250 g.p.h. (80 rise). Winter Air Conditioner ,, Size A, 77,000 Btu output. Size B, 125,000 Btu output. Multivane blower, filters, vaporizing burner. Ceiling Furnace Industrial overhead heating saves floor space. Units are factory assemb led, including vaporizing oil burner (no refractory brick saves much weight), thermostatic control, high capacity heat distributing fan with K hp motor. Conforms to requirement of the Underwriters' Lab oratories for use in garages. A complete line of oil-fired small home heating units --plus special industrial units of moderate capacity. 1031