stationary storage tank at a gasoline dispensing facility If:
.1) The tank t.s equipped with a floating roof or other system of equal or better Mission control.as approved by the Agency:
2) The tank has a capacity of less than 2M0 gallons and Is In place and operating before January I; 1979;
3) The tank has a capacity of less than 575 gallons;.-or
4) The.tank Is not located In any of the following counties: Boone. Cook. OuPage.' Kane. Lake. Madison. McHenry, Peoria. Rock Island. St. Clair. Tazewell. Will or Winnebago.
c) Subject to subsection (b), each owner of a gasoline dispensing facility shall:
1) Install all control' systems and make all , process modif ications required by * subsection (a); .
2) Provide Instructions to the operator of the gasoline dispensing facility describing, necessary maintenance operations, and procedures for prompt notification of .the owner In case of any
malfunction of a vapor control system; and
.........3) Repair, replace or modify any worn out or malfunctioning component or element of design.
d) Subject to.-.subsectlon (b). each operator of a gasoline dispensing facility shall:
1) Maintain and. operate each vapor control .system In, accordance with the owner's . Instructions;
2) Promptly notify the owner of any scheduled maintenance or malfunction requiring feplacment or repair of a major component of a vapor control system;
3) Maintain gauges., meters or other ; specified testing devices in proper working order;
4} Operate the vapor collection system and delivery vessel unloading points In a manner that prevents:
A) A reading equal to or greater than 100 percent of the lower explosive limit (LEL measured as propane) when
. tested in accordance with the procedure described In EPA 450/2-78-051 Appendix 8. and
B) Avoidable leaks of liquid during the filling of storage tanks: and
5) Within IS business days after discovery of the leak by the owner, operator, or
the Agency, repair and retest a vapor collection system which exceeds the 'Units of subsection (d)(4)(A).
e) Gasoline dispensing facilities were required to take certain actions to achieve compliance which are sumnartzed In Appendix C.
(Source: Amended" InMS^HA) at 11 111. Reg. 11774. effective June 29. 1987)
Section 215.584 Gasoline Oelivery Vessels
a) Any delivery vessel equipped for vapor ' control by'use of Vapor collection equipment:
1) Shall havc a vapor space/eewnectTom-thabIs equipped with fittings which are vapor tight;
2) Shall have it's hatcftes cTdsetf at aTT
times during loadtng or unloading
,
operations, unless a top loading vapor
.recovery system Is used; .
3) Shall not .Internally exceed, a gauge , pressure of 18 Inches of water or a vacuum of 6 Inches of water; .
4) Shall be' designed and'mairltaTned'tabe
. vapor tight at' all times during normal operations:
5) Shall not be refilled In Illinois at other' than:
A) A bulk gasoline terminal that complies with the.requirements of
. Section 21$.582 or
B) A-bulk-gasoline plant that complies with the requirements of Section
2TSrS8TT*fHl)*an#'t2).
6) Shall be tested annually In accordance with the pressure-vacuun test procedure described In EPA 450/2-78-051 Appendix A. Each vessel must be repaired and retested within TS business days aflerdiscovery of the leak by the owner, operator, or the Agency, when it fails to sustain:
A) A pressure drop of no more than three Inches of water In five minutes; and"
B) A vacuum drop of no more than'three Inches of water la f lve .minutes.,
b) Any delivery vessel meeting the requirements
of Subsection (a) shall have a sticker affixed to the tank..adj&cgnt.to the tank manufacturer's data plate which contains the tester** name, the tank Identification number
and the date of the test. The sticker shall be In a form prescribed by the Agency, and shall be dlsplayed-no-laterUiaa.Qecemtaeell..
1987.
c) The owner or operator of a delivery vessel shal1: