300 CHAPTER 13 1956 Guide Table 12. Tbansmittances and Absorptances of Common Window Glass for Direct and Diffuse Solar Radiation Angle op Incidence, 0, DEG 50 oo | Single Sheets TWO AIR-SPACED SHEETS D D td aD td Outdoor Sheet Indoor Sheet For Direct Radiation 0.87 0.87 0.86 0.84 0.79 0.67 0.42 0.0 0:05 0.05 0.06 0.06 0.06 0.06 0.06 0.0 0.76 0.76 0.74 0.72 0.66 0.52 0.25 0.0 0.06 0.06 0.06 0.07 0.07 0.07 0.07 0.0 0.04 0.04 0.04 0.05 0.05 0.05 0.05 0.05 0.79 For Diffuse or Sky Solar Radiation | 0.06 | 0.6S | 0.07 | 0.05 dry-bulb temperature cycle, with a 95 F maximum as tabulated. The total heat gain is the sum of the Table 13 and Table 14 values. In preparing Table 14, convection and radiation heat exchange were combined, and a combined surface conductance of 4.0 used. Corrections to be applied for other design temperatures are given in Table 23 in a later section,/Effect of Deviation from Design Conditions. Tables 13 and 14 may be used for other types of glass with good accuracy, by using the factors given in Table 15. Table 13 values are multiplied by the appropriate factor given in Table 15 to obtain heat gain due to trans mitted solar radiation. For glasses having a transmittance for normally incident radiation differing from the table values, factors may be found by linear interpolation. To obtain instantaneous rates of heat gain by con vection and radiation, two steps are required. First, Table 14 values are multiplied by the appropriate coefficient of X listed in Table 15. Second, Table 16 values are multiplied by the appropriate coefficient of Y listed Fio. 3. Convection and Radiation Heat Flow for Vertical Single Glass: Cooling Load 301 Table 13. Instantaneous Rates of Heat Gain Due to Transmitted Direct and Diffuse or Sky SoDar Radiation bt A Single Sheet of Unshaded Common Window Glass For Clear Atmospheres and 18 Deg Declination, North (August 1) Note: For total instantaneous heat gain, add these values to the Table 14 values. a t it u d e 1L Sun Time Instantaneoub Heat Gain in Btu per (hr) (sq ft) AM - r N " NE E SE S SW W Nff Horiz. sc 6 a.m 6 p.m. s7 5 o Z9 3 a 10 Q o 11 12 2 1 25 98 108 23 155 190 16 148 - 205 16 106 180 17 18 18 ' 54 . 128 20 59 19 19 5 a.m. 7 p.m. .6 6 5 Z 3 26 16 14 a 9 11 3 1 -- 15 16 17 17 5 a.m. 7 p.m. *6 75 Z 20 25 12 13 a9 n 3 14 15 16 16 7 116 149 129 79 31 . 18 17 . 54 128 139 107 54 18 16 16 6 131 195 205 180 127 58 19 54 149 197 202 176 124 57 18 __ r PM -- N Nff | W , 52 110 136 136 116 78 35 2, 67 124 156 .- 162 148 113 64 - 20 81 136 171 183 174 143 96 5 10 14 21 34 45 49 0 7 II 18 42 69 90 98 3. 8 12 32 72 110 136 144 SW S 10 13 15 17 19 35 0 6 10 12 14 16 23 64 3 7 10 12 14 16 42 96 SE 13 13 137 15 15 195 16 16 241 18 18 267 19 19 276 6 10 12 12 137 14 16 17 19 17 259 10 12 12 129 14 15 16 18 16 234 E NE | Horiz. Table 14. Instantaneous Rates of Heat Gain by Convection and Radiation from a Single Sheet of Unshaded Common Window Glass For Clear Atmospheres and 18 Deg Declination, North (August 1) For 80 F Indoor Temperature Note: For total instantaneous heat gain, add these values to the Table 13 values. Sun Time Dry- North Bulb Latitude Deg F Degrees N 5 a.n 6 7 10 11 12 1 p.m. 2 3 4 5 74 --6 74 --5 75 --5 77 --3 80 83 87 90 30,40,50 93 94 95 94 93 91 87 3 8 12 15 16 17 16 15 13 85 6 83 3 Instantaneous Heat Gain in Bto peb (hr) (sq ft) NE --6 --1 --2 0 2 4 8 12 15 16 17 16 15 13 8 6 3 E --6 --4 --2 1 4 6 10 12 15 16 17 16 15 13 8 6 3 SE --6 --5 --3 0 3 6 11 13 . 16 16 17 16 15 13 8 6 3 S --6 --5 --5 --2 1 5 10 14 17 18 19 -17 15 13 8 6 3 SW --6 --6 --5 --3 0 3 9 13 17 19 21 20 18 14 8 6 3 W --6 --6 --5 --3 0 3 8 12 17 19 21 20 19 15 8 6 3 NW --6 --6 --5 --3 0 3 8 12 15 17 19 19 18 15 8 6 3 Hor. --6 --5 0 3 16 21 21 17 13 8 6 3