a fire-resistant, heat-transfer agent that operates up t.o 600"l". in the litjuiJ phase
i
TOWOLDMONOQ26120
022-`, t
O'
........................... has been used successfully since 1941 as a liquid phase heat transfer medium at atmospheric pressure and temperatures up to 600F.
The compound, essentially tetrachlorobiphenyl, is a fire-resistant and noncorrosive liquid, which does not crystallize at low temperatures. Handled properly, in ' well-designed forced circulation heat exchangers which avoid localized over heating damage, the fluid gives satisfactory continuous service for many years without replacement.
Most significant, Aroclor 1248 is practically non-flammable. In one installation of record, a ruptured pipe that spewed the hot fluid into gas flames failed
to cause the fluid to ignite. For general heat transfer, Aroclor 1248 has several other important
qualities: it is highly mobile and can be readily pumped at temperatures as low as 50"F. If cooling is necessary, the heat transfer fluid can be put through a water cooler to be used as a coolant.. . using this single fluid for both heating and cooling.
Aroclor 1248 transfers heat (up to 600F.) as a liquid. This liquid phase heat transfer makes it unnecessary to use the expensive pressurized equipment required by a heat transfer medium that operates as a vapor. Aroclor 1248 operates safely and
efficiently with gas-fired, oil-fired, or electrical heat sources. It is used successfully in the following types of applications ....
' ''
j
J | . i ! . ; ( 1 ^ ; j
l
0221^80
Chemical Processing Equipment, particularly for reacting flammable materials
Cooking of Alkyd resins, varnishes, waxes
Plastics molding, extruding, calendering
Rubber processing
Heating asphalt
Food Processing, including potato chip and doughnut frying in vegetable oils
Processing titanium, magnesium, other non-ferrous metals
Fabrication of magnesium and aluminum honey-comb structures for aircraft
Indirect heating in dyestuff manufacture
Heating of corrugating rolls
.
Indirect heating of distillationequipment
Saponification of fats
Calcining Ovens
Impregnation and lamination of fibrous materials
TOWOLDMONOQ26122
I
illili Vrr
AROCLOR
1248
Appearance Absolute density, g./ml.
Absolute viscosity, centipoises
Thermal Conductivity, Btu./hr.sq. ft/F./ft
Spec. Volume, ml./g.
Practically colorless mobile Squid.
Temperature 'Centigrade `Fahrenheit
1.44 30 86
1.41 60 140
1.37
100 . 212
1.27 200 392
300 572
112.0 30
17.5 . . 60
4.2 100
0.99
200
0.47 300
86 140 212 392 572
0.0571
30
0.0564
60
0.0555
100
0.0534*
200
0.0512*
300
* Extrapolated Data.
.
86 140 212 392 572
0.6% 30 0.709 60 0.728 100 0.787 200 0.860 300
86 140 212 392 572
Table 1
TOWOLDMONOQ26123
(Table I, coot.)
Spec. Heat, cal./g./C.
Vapor Pressure, mm. Hg.
Distillation Range, ASTM D-20 Flash Pt., Cleveland Open Cup,
ASTM D 92-45 Fire Pt, Cleveland Open Cup,
ASTM, D 92-45 Pour Pt, ASTM, D-97 . Average Coefficient of Expansion
cc./cc./F.
0283 0297 0.326 0.355
0.00037 0.16 2.9 18.0 350.0
`Centigrade 50 100 200 300
`Fahrenheit 122 212 392 572
37.8 100 150 " 200 . 300
100 212 302 392 572
345-385
652-725
193-196
379-384
None
0.00037 0.00038 0.00041 0.00044 0.00047 0.00052
--
-7
-17.8 to 37.8 37.8 to 93.3 93.3 to 149 149 to 204 204 to 260 260 to 316
--
19.4
0 to 100 100 to 200 200 to 300 300 to 400 400 to 500 500 to 600
4
PHYSICAL CHARACTERISTICS
of
AROCLOR 1248
A complete knowledge of the physical characteristics of heat transfer media is highly essential to their satisfactory application in a heat exchanger. These physical constants have a major bearing on the equipment design, its mainte nance, and its operation. . The following figures and charts give basic physical data on Aroclor 1248.
0221482
TOWOLDMONOQ26124
0 2 2 1 '*83
DENSITY OF AKOCLOR 1248
(Top axis, Ibx./cu. Ft.; bottom axis. Km./ml.)
TOWOLDMONOQ26125
VISCOSITY OF AROCLOR 1248
0221A84
VISCOSITY OF AROCLOR 1248 (Saybott Universal Seconds)
<
(Si
rsi O
VISCOSITT. SAYBOLT UNIVERSAL SECONDS
'
ii
i
i
I
i
II1
I I II
I 4.
'38 -20
0
20
40
60
80 100
120 140 160UQ20Q220 24a 260 2360329340 350
Figure 3
TEMPERATURE, DEGREES FAHRENHEIT
7
TOWOLDMONOQ26127
0 2 il'< 8b
HEAT CAPACITY and Its Relationship to Density
Systematic errors exist in the various accepted pro* ccdures for making specific heat determinations. Consequently values may vary depending upon the procedure used. In practical operation, it frequently appears that the values for Aroclor 1248 shown in Figure 4 are somewhat low. Consequently, although these values have been accurately determined, they may be regarded as conservative.
When comparing the specific heat values of Aroclor 1248 with corresponding values for other heat transfer fluids, it is important to note that the density of Aroclor 1248 is much higher relatively than the density of other liquids used for heat transfer. Accord ingly, when comparison of heat capacity is made on a
volume basis (which is most pertinent in equipment design and efficient ojicrution) the heat capacity of Aroclor 1248 shows itself to l>etter advantage than by direct comparison of specific heat values.
Although specific heat values are important, they represent only one of several important constants that enter into the equations for calculating over-all heat transfer efficiency.
Through the use of these conservative heat capacity values, it is possible that equipment engi neered from such data might be slightly "over designed." It may be one of the factors that accounts for the exceptionally good operating performance of a number of highly successful commercial applications.
TOWOLDMONOQ26128
SPECIFIC HEAT OF AROCLOR 1248 (Btu. per lb. per degree F.)
t
TEMPERATURE f.
TOWOLDMONOQ26129
: -*
!
! I 10
oin
Temperature 6C, P,
0 ll 10 50 38 100
66 150 93 200
121 250
149 300 177 350 204 400
232 .
450
260 500
288 550 316 600
heat content
of Aroolor 1248
. Specific Heat Btu./lb./'F. .269 .272 . .280 .288 .295 .303 .311 .319 .327 .335 .343 .351 .359
Heat Content BUI. /lb.
0.0 4.85 18.65 32.85 47.43 62.38 77.58 93.48 109.66 126.21 143.17 160.52 178.27
00
4T
TOWOLDMONOQ26130
0221489
THERMAL CONDUCTIVITY and VISCOSITY
The thermal conductivity values of Aroclor 1248 are shown in Figure 5. The curve shows this value over Aroclor 1248's operating temperature range, from 50F. to 600F.
As freshly charged into a heat exchanger, Aroclor 1248 has an initial viscosity of 74 (S.U.S.) at 130F. which corresponds to a viscosity of approxi mately 5000 (S.U.S.) at 50F. -- which temperature is assumed for practical purposes to be about the limit at which Aroclor 1248 can be conveniently pumped with a centrifugal pump.
The following table shows a comparison of the initial yiscosity and the viscosity after a year's con tinuous service at 600F. in a LaMont forced circu lation heater:
TABLE III
Appearance Specific Gravity. 65 C. Viscosity, S. U. S. at 130f.
Original
Colorless liquid 1.410 74.0
After one Year of service at
600F.
Dark Brown Liquid
1.418
83.5
Although Aroclor 1248 tends to darken in use,
this darkening is not harmful and does not indicate decomposition. In actual use at .Monsanto, it has not
been found necessary to replace the fluid after seven years of continuous use; additional fluid is only added as necessary to make up spills or leaks.
In Figure 6, the horizontal line indicating vis cosity limit of pumpability at 50F. shows that the
rate of viscosity increase based on a year's continuous
service should permit Aroclor 1248 to serve approxi
mately four years before increased viscosity may inter
fere with its pumpability when cold. In practice,
Aroclor 1248 has given satisfactory pumpability for
much longer periods. A simple S.U.S. viscosity deter
mination by the ASTM-D-88 method can be used for
periodic checks on the fluid.
f
t TOWOLDMONOQ26131
O feV tZ Z O
THERMAL CONDUCTIVITY OF AROCLOR 1248 (Dotted extension indicate* extrapolated data)
I
i
j
i t
l
|
Figure 5 12
THERMAL CONDUCTIVITY, Bttt./(Hr.) <$Qit)(F-XTL)
TOWOLDMONOQ26132
EXPECTED MINIMUM SERVICE LIFE IN A FORCED CIRCULATION HEATER
i
VISCOSITY, SAYBOLT SECONDS, i t 130?.
13
TOWOLDMONOQ26133
0221*92
STABILITY
Aroclor 1248 is an extremely stable chemical com pound. Tests over long periods of time have shown that 600F. is a safe maximum temperature for continuous operation in heaters that are properly designed and operated to eliminate intense, localized overheating. At this temperature the fluid is 52F. 1m?1ow the initial temperature of its boiling range, and consequently re mains a liquid.
Near its boiling point Aroclor 1248 tends to dehydrohalogenatc to a very slight but measurable degree. If this occurs as a result of accidental over heating, the small amount of HC1 gas evolved tends to pass through the vent tank without harm to the equipment provided that the system is dry.
Experimental observations using ideally-suited heat exchangers operating at a temperature of 650F. with imposed nitrogen pressures of 30 and 70 psig. showed that application of pressure did not prevent this small amount of thermal decomposition, which also occurs when the material is heated above 600CF. at atmospheric pressure.
When heated continuously at 650F. under nitrogen pressure a gradual increase in the viscosity of the fluid occurs indicating that its service life would be limited to about 6 months to one year.
Results of operating at fi00"F., however, with out imposed nitrogen |>ressuro indicate Aroclor 1248 can 1m* heated continuously at this tem(MTatiire for about 4 years lx*fore any viscosity increase could 1m* exacted to interfere with its puuipahility at 50 F. which is slightly 1m*Iow normal r<M>m tem|M*ruturev
Provision should Ik* inade to prevent water contamination of the system. If the system lK*comes contaminated with water, any HC1 liberated by local ized overheating may dissolve in the water film which will float on top of Aroclor 1248 in tlx* expansion tank. The acidic solution thus formed can cause corrosion. It is recommended that moisture 1m* c]imiiuit(*d from the expansion tank by installing a moisture trap or by sealing the tank and applying 15 to 30 psig. of nitrogen gas. With exception of the expansion tank, the system should be kept full of Aroclor 1248 at all times to pre vent formation of air pockets where moisture may condense when the system c<x)ls off between periods of operation.
Many years of practical operating experience has shown that Aroclor 1248 is virtually non-corrosive to valves, piping, tanks, and jackets made of vast steel, steel, or stainless steel. In actual use, brass valves have been used satisfactorily.
SAFETY of OPERATION
* Aroclor 1248 can be considered a non-flammable liquid; no fire point is obtained by the Cleveland Open Cup method on heating to its boiling point (650F.). The spontaneous ignition temperature*2* is 1,299F.
In actual use, the following reported accident in a heating system demonstrates the fire resistance of Aroclor 1248 ami the freedom it offers from the hazard of fire propagation. An operator's failure to start the circulation pump when the gas heater was on resulted in excessive coil temperatures. The line containing Aroclor 1248 sagged into the fire chatnl>er. A weld rup tured and Aroclor 1248 poured into the red-hot fire chnmlxT in contact with the flame. Dense smoke and fumes arose from the heater but there was no external fire. After the gas flame was cut off, the smoking stopped.
Insurance authorities allow the use of Aroclor 1248 heaters in many locations with a minimum of protection. No fire walls are required to isolate the heaters.
Aroclor 1248 has a low vapor pressure. In sys tems that employ a vented expansion tank, the loss due to evaporation is not measurable. If Aroclor 1248 in the expansion tank would reach a temperature of
266F., the vapor pressure of the fluid would be only 1 mm. of Hg.
SAFETY OF HANDLING
Aroclor 1248 is an inert, unreactive liquid. If it is spilled on the skin, there are no noticeable ill effects. It is advisable, however, to wash the skin with soap and water after contact.
A skin burn resulting from accidental contact with hot Aroclor 1248 should be treated in the normal manner for hot oil burns. Any liquid adhering to the burned area need not be removed immediately unless treatment of the burn demands it. If the burn must be cleaned, soap and water or repeated washings with a vegetable oil (olive oil) may be used.
The vapors emitted by Aroclor 1248 heated to elevated temperatures are injurious on prolonged ex posure and should not be breathed. It is indicated that 2.0 mg. of Aroclor 1248 per cubic meter of air is the maximum safe amount permissabic in workrooms. In commercial heat transfer installations, it is presumed that Aroclor 1248 will be used in a closed system free from leaks. Accordingly, their should be little or no opportunity for workers to come in contact with Aroclor 1248 vapors.
of a
COMPLETE SYSTEM
HEATER
The most significant factor to rememlxjr when selecting or de signing a heat exchanger for Aroclor 1248 use is this:
Aroclor 1248 transfers heat as a liquid, tit the maximum recom mended temperature of 000K. for continuous operation, which is approxi mately 50t>l,\ Iwlow the boiling point. Consequently. Aroclor 12-18 does not form vapor to accelerate convection circulation. Ordinary fire-tube or water-tul>c heaters which dej>end solely upon convection perform satisfactorily only at relatively low tcmixTuturcs.
When temperatures of 500-fi(X)''F. are required, a forced circu lation type heater is recommended. A satisfactory tyjx* of heater design would consist of a specified miml>er of tul>es in {larallel. pro|xrly orifieed to provide a high velocity fluid flow of 8 to 10 feet per second. These should be spaced to permit uniform heat absorption throughout their entire length. A typical construction is shown in Figure 7.
In its fabrication, the heater should l>c ASME Code all-welded construction, conforming to state and local ordinances. Tube joints, which in an ordinary steam heater would he the expanded type, must be sealwelded to prevent leakage. All connections larger than should be flanged connections, since ordinary threaded pipe connection is not suited for Aroclor 1248 service. Spiral-wound stainless steel and asbestos com bination is recommended for sealing joints and plugs.
Drain valves should be installed at all low points on the hdater and the valves must conform with ASME requirements for "blow down" valves.
TOWOLDMONOQ26136
022lV 5
Since a heater operating on Aroclor 1248 is completely filled with liquid, costly liquid-level controls and condensate return pqx*s, fittings. tr;q>s, etc. are completely eliminated.
Heaters can Im* provided with any desired kind of firing. Portable and small size stationary are frequently electrically heated; larger units may l>e gas- or oil-fired. In installations where an open flame present* a fire hazard, to meet insurance requirements the heater may be installed in a separate build ing with piping carrying the hot Aroclor 1248 to the point of use. Properly constructed transmission pipes may extend for hundreds of feet.
HEATER EFFICIENCY
Forced circulation heaters with integral economizers will show
an efficiency of from 75 to 80%. Heaters of the straight con nector type show efficiencies of 65 to 75%, depending upon the discharge temperatures.
HEATER CAPACITIES
Heaters using Aroclor 1248 (gas- or oil-fired) are available in output capacities ranging from approximately 250,000 Btu. per hour to large units rated over 10 million Btu. per hour. A heat flux density (or heat energy input) of approximately 5,000 Btu. per hour per square foot of tube surface is regarded as satisfactory.
For lower output rate, elcctrically-heated units are favored, employing watt densities of 12 to 16 watts per square inch.
i
17
TOWOLDMONOQ26137
THE USERS
Tlit "users" or rtt ipicnls of the licat at the point of processing can be any type of In-aling pan, platen, jacketed kettle, or coils of steel or stainless steel construction. Ordinary low pressure construction is satisfactory, since the pressure imposed on the Aroclor 124H seldom exceeds 50 psig. In the user, however, it is important that all-welded construction be used. Threaded connections may allow leakage of the hot fluid. As in the heater, all connections N" and over should be flanged and all joints sealed with spiral wound stainless steel and asbestos gasket material. Alloy bolts should lie used to secure flanges. A typical system with several users is shown in Figure S.
EXPANSION VESSEL
FULL EXPANSION LEVEL GAUGE
COLO START
0 2 2 1 *S b
STORAGE TANK
Figure 8
TOWOLDMONOQ26138
THE PUMP
For most systems, cast-steel centrifugal pumps with watercoolgd stuffing box and bearings are to be preferred. However, high temperature centrifugal pumps with mechanical seals are now available which give excellent performance. In some in stallations, immersion pumps have been used. Whatever type is selected, the pump capacity and pressure head must be sufficient to circulate the volume of fluid at the rate the particular installation demands.
' To avoid shaft trouble and leakage at the seals, it is important to provide adequate expansion joints and to support the piping in a manner to avoid stresses on the body of the pump. Dircct-conncction pumps driven by 1,750 rpm. motors are most commonly used. Each pump should be fitted with a positive differential control to switch off the burner in case of pump failure.
When a new system is first put into operation, a slight leakage may lx* noticed at the pump. It is not advisable to tighten the pump gland, however, until the system has heated tip dose to tin* temperature of operation.
PIPING LAYOUT
Tito most important factors in the piping layout for
AnicW I2IS *vNt<*ms are (a) {troper sizing for the required
Ihw nAr wmI (Ii| iniiiiitii/iiig |m*s*urr drop. Ikvause tlie sys-
ttmn will nniilnttQw Imupn-jfiMr duiij'n. atk-qiMle expansion
j|milt.s mill
tti> inHW\\<e
.**#1
strips are
ttmmUuil
AlllpipM-llness.mii!
s'fWi&J t#* 14 extra heavy
sVtonlide ttiPwi'tiUniL'tMKtSMt'ftuw
utentt: Pl.wigiili jomK diimliti lie
prfntbfe
id minimt/c |h)t/n<Hai leak*
All valves and controls should be cast steel construction with stainless steel seats. Pipe lines should be well insulated and those exposed to temperatures below 70F. should be steam jacketed.
All high points in the piping system should be provided with vent valves; all low points should have drain connections. Piping should be well anchored at frequent intervals, particu larly near expansion loops, to prevent vibrations.
Figure 9 shows a typical piping diagram that illustrates the important features of an Aroclor 1248 piping system. These may be varied to suit the installation.
TOWOLDMONOQ26139
0 2 2 1 V *9
the expansion tank
The expansion tank should he large enough to accom modate alxxit 20% of the total volume of the entire system, including the fluid content of the heater, piping, and all heatusers. Tank should lx* sized to lx? Vi-full wlten system is cooled to 70' F. and %-fnll when system is at maximum operating temjx*rature. Expansion tank should lx? fitted with a sight glass at the "full" range and a float-ojx*rated low-level switch to shut off burner in case of accidental fluid loss in the system.
The expansion tank should he mounted on a platform high enough to support the liquid reservoir at least six feet higher than the highest point in the piping system.
THE FEED and DRAIN PUMP
To eliminate manual filling and draining of the heating system, it is recommended that a small 2-to-5 gpm. positive displacement pump he installed at some convenient point to pump the Ar<K.*lor 12-48 into or out of the system.
CONTROLS
Controls for heating systems using Aroclor 1248 should lx? installed both on the heater itself and on the heat-using units. A wide variety of thermo-operating controls are available and any reliable standard equipment is satisfactory.
Heater controls should be installed to regulate the firing mechanism in direct proportion to the required output. These controls should increase or decrease the heat in-put to main tain the Aroclor 1248 at the operating temperature required by the heat-demand of the user. Small units may be operated satisfactorily by relatively simple "on-off' or "high-low" con trollers; larger units may operate more uniformly if equipped witli modulating temperature controls.
User Controls should be installed to regulate the flow of the heat transfer fluid in direct proportion to the heat-con sumption of the heat-using equipment. In a multiple-user sys
tem, separate controls should lx? installed on each consuming
unit, to assure the proper heat-delivery.
Safety Controls. In addition to activating controls, the
heater must also lx* fitted with the proper safety controls to
meet the A.S.M.E. requirements. Safety controls should
include:
1. A high temperature limit control operating at the heater outlet to shut olf tlie hunter in tire event of an cxeci\c tein|eratiire rise.
2. A .suitable low-limit trtii|K-rature control to hold the Imrncr at low lire tintd the Aroclor 1248 in the system reaches a temjH ralure
level of 180*1**.
,
The low limit tcm|x*raturc control is essential lx*cause
the viscosity of Anxlor 1248 is rather high at normal room tem
perature. To avoid localized overheating upon start-up, it is not
advisable to apply full heat from the burner until all the fluid
in the system has attained a viscosity that allows gixxl flow and
unimpeded circulation. Cold start-nps require slow tip-heats.
Burners should lx* equipjx*d with automatic ignition
controls and flame failure controls. In wide-range firing opera
tions, an over-fire draft control will increase* the economy of
operation. Induced draft fans are another factor which should lx?
considered as a means of avoiding the excuse of high chimneys.
Where they are needed throughout the system, good
quality recording or indicating gauges should lx* installed.
COOLING EQUIPMENT
Where fast reduction of temperature is required suitable, air- or water-cooling installations may lx? used. If the cooler is to be a water-type unit, it is suggested that stainless steel tubing be used for the cr>ils to avoid corrosion on the water side. If a cooler is installed in the system, low temperature jimit con trols should also be installed to avoid excessive cooling that might raise the viscosity to the point of impeding the circulation in the system.
TOWOLDMONOQ26140
0221499
FILTERING EQUIPMENT
When heating systems operated on Aroclor 1248 are run continuously near the maximum temperature of recommended : operation (600 F.), it is advisable to provide a filtering device that can be attached to the drain line of the storage tank. In this . way discrete particles of dirt that may get into the system can be filtered out periodically. This is an advisable maintenance step since it will eliminate the danger of dirt clogging the valve seats or lodging in parts of the control mechanisms.
A small portable filter such as those manufactured by Honun-Cranc Corporation (Ixbanon, lnd.) or Sparkier Manufac turing Ounpany (Mundelein, 111.) is quite satisfactory.
CONNECTIONS and GASKETS
In u system operated on Aroclor 12*48, welded connec tions are preferable; threaded screw connections should be
avoided wherever possible. This precaution will minimize leaks with consequent make-up. All connections 1" and over should
W- (hinged (ype fastened with alloy bolts to prevent frozen
connections. Steel connectors should be used for all instruments
and control*. For gasketing, spiral wound gaskeU of corrugated
fcluioh's* steel and aslxsto* cowbinalhw slmijld fw? used on all
flanged connections.
>>
TEST! NO and GLEANING THE SYSTEM
When a new system has been installed, it is essential to test the entire system hydrostatically for leaks, and to wash out all the lines to remove dirt, oil films, or pipe scale. Both the cleaning and the testing can h<; done with a single operation, such as the following:
, , Fill the entiro system with a water solution containing 5 pounds of soda ash and 5 pounds of caustic sodp for every 1000 pounds (1^0 ga|.) of w^r usedt Thoroughly vcut.thp sys
tem at all of the highest points in the piping system to assure complete filling . . . then start the circulating pump. With the pump running, the entire system is next inspected for leaks.
Next, turn on the burner at low-fire rate and raise the temperature of the wash solution to 1805F. This hot wash solu tion should be circulated continuously through the entire system (heater and all users) for at least 24 hours. At regular intervals a portion of the solution should be drained and replaced by fresh water. This partial draining should he continued at regular in tervals until the drainage from the system is clear.
At the end of the 24 hour period, the temperature of the circulating wash solution should lx? brought up to 24(TF. and the fire turned off. The whole system should then lx drained and all vents in the piping opened. Residual heat will dry the pipes and the heater through the vents, which should remain open until inspection shows that the system is entirely dry. When all traces of water have dried out, the drains and vents are closed.
Aroclor 1248 is then charged into the cleaned, dry sys
tem. The circulating pump is started ami firing begun at low
heat until the Aroclor 12 IS has reached a temjxratnre of 250 F.
Periodically during this initial np-lieatiug, the line* should he
vented every 10-15 minute* for at least two hour* to allow any
residual moisture or air to escape. After it is certain that ail
moisture has been eliminated from the system, the entire system
should lx inspected for leaks with the pump circulating the hot
fluid. As a final inspection, the expansion tank should lx checked
to make sure that the tank is Vi full. After this, the burner can lx
set to full-fire and the system brought up to operating tem
perature.
:'
, , When the temperature of operation has Ixen reached
all controls should lx checked and adjusted so that the burner
is regulated for full, modulation, When the system is brought to
full operating temperature, all pipe lines should be gjvyn a final
insp^ctjion for expansion and bracing.
t
21
TOWOLDMONOQ26141
0221500
GENI'RAL RECOMMENDATIONS for Operation and Maintenance
Tfic following recommendations are primarily guides for the manner of using Aroclor 1248 in an operating system. They are supplemental to the equipment manufacturer's own recommendations for operation ami maintenance that relate to the heaters or the heat-using installations themselves. The recommendations for start-up, shut-down, precautions in event of power failure, and jXTiodie check-ups on the fluid and equip ment apply as generally accepted practice on all tyjH*s and sizes of systems. By following these recommendations, the troublefree service life of the heat transfer fluid will he increased.
START-UP
When systems have been shut down for week-ends or over-night and the fluid is cooled to room temperature, follow this start-up procedure:
1. Start the circulating pump and check the expansion tank to make certain the Aroclor 1248 is at the proper cold-start level (Tank should be Vo-full.)
2. Start burner at minimum flame setting and continue full circulation until Aroclor 1248 is heated to 180*F. when measured on tlx? return side of the heater,
3. Turn heater up to full heat.
SHUT-DOWN
The following procedure will eliminate overheating of the fluid when shutting down:
1. Shut off burner completely with circulating pump still oper ating. Continue to run the circulating pump at full head for at least Vi hour to dissipate high residual heat in the com bustion chamber of the burner.
2. Shut off circulating pump at the end of % hour and switch off all heater electrical controls.
PRECAUTIONS IN COLD WEATHER
When heat exchanger is exposed to ambient tempera tures below 50eF., it is recommended that unit not be shut down. It is recommended that the burner be turned low and the fluid circulated continuously at about 200F. The unit will then be "at ready" for immediate high temperature operation.
PRECAUTIONS IN CASE OF POWER FAILURE
In case of power failure, the burner circuit is interrupted by the heater controls. When power tomes on, the? circulating pump should first be nut for a few minutes to eliminate any vapor pockets that might have been formed by Ihe fluid's being held static in the hot combustion cIiuiuImt. If there is no knock ing in the piping system, full-fire may Ik? resumed immediately.
PERIODIC CHECK-UPS
The regular maintenance msjxtfion schedule sltould
include the equipment manufacturers recommendations and
also inspection of the heat transfer fluid. The following is a
listing of chock jxmits.
,
1. Lubrication of moving parts. 2. Operating fidelity and accuracy of readings of safety controls
and tem|xruture limit controls.
3. InsjH-ction of heater tu!x*s, Imrner, refractory linings. 4. Periodic cleaning of heater surfaces. 5. Inspection of water cooling at the circulating pump.
6. Regular repacking nf stuffing boxes according to the manu facturer's recommendations.
7. Semi-annual or annual sampling and analysts nf Aroclor 1248.
Under normal operating conditions not affected by fre quent power failures or accidental overheating, when Aroclor 1248 is operated at 600F. it should not be necessary to check on the condition of the fluid more often than once or twice a year.
The analysis for fluid condition is a simple determina tion of viscosity. The information given in Figure 6 serves as a guide to estimate the condition of the fluid, according to vis cosity values. Most users do their own testing; some have the viscosity determination made by an outside laboratory.
Customers can have their fluid tested by Monsanto free of charge. A one-quart sample is required, and sample should be carefully packed to avoid breakage in shipment Samples should be shipped to:
Monsanto Chemical Company
Organic Chemical Division
Industrial Fluid Sales
St. Louis, Missouri
22
ni r- 1
F
mU\
Designing or purchasing equipment for a heating system to be operated with Aroclor as a medium to deliver heat into a process requires consideration of heat transfer characteristics of both the user and the heater. The actual heat which can be absorbed by a user, for example, depends upon the over-all heat transfer coefficient, heat transfer area, and a mean tem perature difference between Aroclor and the material being heated. Both overall heat transfer coefficient and mean temperature difference are. in turn, affected by the flow rate of the Aroclor. .This inter-relation of flow rate, heat, and temperature is usually solved by a trial and error procedure as covered in standard reference texts. The approach of Granet-3 may be used to minimize or eliminate trial and error.
The following tables and graphs of physical properties and engi neering data are provided as an aid in layout and design calculations for systems to be operated with Aroclor 1248 as a heat transfer fluid in the liquid phase.
Table IV lists properties useful in heat balance calculations by which the flow rate is related to the heat transferred and the temperature change of the Aroclor. This relation is also shown graphically in Figure 10.
The over-all heat transfer coefficient for the heater or user may be estimated by the methods outlined in the texts of McAdams4 or Kern-5. This is usually done by combining the individual film coefficient of the Aroclor with other coefficients and conductivities to yield the over-all coefficient. Table V contains physical properties of Aroclor as a function of temperature which are needed for calculating the Aroclor film coefficient. Tables VI gives typical film coefficients for Aroclor flowing through a 0.81 inch i.d. tube. These are listed as a function of temperature and flow rate in a tubular heat exchanger. Other tube sizes would, of course, require a correction for the diameter in the Reynolds and Nusselt group of the equation (from McAdams) given at the top of Table VI. Correlations for estimating film coefficients for various material that might be processed by indirect heating may be found in the texts 4 and 5 cited and elsewhere in the literature.
For sizing pipe lines and pumping requirements. Figure 11 shows pressure drop vs. flow rate and pipe size for Aroclor 1248 at temperatures over 300F. Above this temperature Aroclor 1248 flows freely like water.
23
TOWOLDMONOQ26143
0 iil5 0 1
*.
gSSSs282i83331sS8gS33KsgSSsiBS3ii2iSSgSS5Sss8B!iss83esssBS5ss;s.,
if
iliiliiilBiliiiillilBiiiliiiiiiiiiiliiiSiiimmmm
I-
zS=S25"g22222222ggggg2ggggSgSgSS5SS5gsgggs52EigEigggn
r gi
sSSS5SSS^ill=llllliillllg|lllllllS55l5Slll5l55lllilllSS
I
i
sI2SS21gglSl55iisssig==555g5555SSgss2i:S2:==S8'siisSsg
l
0221502
TOWOLDMONOQ26144
FLOW RATES FOR AROCLOR #1248 ifSo
TOWOLDMONOQ26145
TEMPERATURE DIFFERENTIAL F OF AROCLOR ENTERING AND LEAVING THE USER
THERMODYNAMIC PROPERTIES of AROCLOR 1248 PRANDTl
TMfMikm f. C.
AbtoMi Viscosity
Lbs.
Hr. Ft
TkOffllOf CMdwIinb
Bt.
ft. Hr. if.
rvrC9M
k L*J
Tooipirstars F. C.
AkaMi Viscosity
lbs.
Hr. Ft.
Tfctrmol Coo<wrtwity
Bta.
Ft Hr. f.
k
ivr
LkJ
I * 32 0
0.0577
i>
40 4
.0576
yI
SO 10
0.575
l:
60 16 2060
.0574
9844
39.5
70 21 960
4)573
4430
28.7
80 27 485
.0572
2353
22.3
90 32 278
.0570
1361
17.9
100
38 -
160
.0569
789
14.4
110 . '
43
114
.0568
566
12.6
120 . - 49
77.5
.0566
388
10.8
130 ''54 v 58.0
.0565
293
9.7
140
43.5
.0564
221
8.7
150
33.8
.0563
173
7.88
160
71
26.6
4)562
137
7.15
170
77
22.0
4)560
115
6.68
ii
180 82 112 .0559 95
6.18
190
88 . . 15.2
.0558
80
5.78
14
200 93 12.6 .0557 67
5.38
210 99^ 10.6 .0555 57
5.05
220 104
9.45 .0554
51.1
4.83
230 110
8.10 .0553
44.1
4.55
240
116
.7.26:
.0552
39.8
4.36
250 121
6.48 .0550
35.9
4.18
260 127
5.76 4)549
32.1
4.00
270 132
5.03 .0548
28.2
3.81
280 138
4.75 4)547 26.8 3.73
290 143
4.40 .0546
25.1
3.63
300 149
4.07 .0544
23.4
3.53
310 154
3.83 .0543
22.2
3.45
320 160 330 166 340 171 350 177 360 182 370 188 380 193 390 199 400 204 410 210 420 216 430 221 440 227 450 232 460 238 470 243 480 249 490 254 500 260 510 266 520 271 530 277 540 282 550 288 560 293 570 299 580 304 590 310 600 316
3.53 .0542 3.34 .0541 3.14 .0540 2.95 .0539 2.78 .0537 2.66 .0536 2.54 .0535 2.42 .0534 2.32 .0532 2.20 .0531 2.10 .0530 2.03 .0529 1.93 .0527 1.83 .0526 1.76 .0525 1.71 .0524 1.64 .0523 1.57 .0521 1.51 .0520 1.45 .0519 1.38 .0518 1.33 .0516 1.28 .0515 1.22 .0514 1.18 .0513 1.13 .0512 1.09 .0510 1.04 .0509 1.01 .0508
20.6 19.6 18.5 17.5 16.7 16.1 15.4 14.8 14.3 13.7 13.1 12.7 12.3 11.7 11.3 11.0 10.7 10.3 10.0 9.67 9.26 9.00 8.72 8.36 8.14 7.85 7.63 7.33 7.16
*
3.35 3.29 3.22 3.15 3.08 3.04 2.99 2.94 2.90 2.85 2.80 2.76 2.73 2.68 2.64 2.61 2.58 2.54 2.51 - 2.46 2.43 2.40 2.37 2.34 2.31 2.28 2.25 2.22 2.20
Table 5
26 0221504
TOWOLDMONOQ26146
0 2 2 1 3 05
HEAT TRANSFER DATA for AROCLOR 1248 . (FILM COEFFICIENT)
b - psQ [t] " [t] v
Baud m flow tbrovfb 0J1' I. D. tvbo (1' 0. D. x 13 fa.) oxprasud la Bta./st ft. hr. F. FLOW ATE 6PM
*F.
1.0 2.0 3.0 4.0 5.0 6.0
7JO
8.0
9.0 10.0 1U) 12.0
ISO
83.2 86.2
93.8 103
114
123
130
200
44.9 614 78.7 94.0 109
124
138
151
164
179
191
250 33.5 58.5 80.9 m 122 141 159 177 195 212 229 245
300 40.5 70.1 97 122 146 169
191
212
233
254 274
294
350 45.3 79.0 109 137 164 190 215 239 262 286 309 331
400 49.0 85.5 118 149 178 206 232 259 284 309 334 358
450
53.3 '
93
128
162 193 224
253
282
309
336
363
388
500 56.3 98 136 171 204 236 267 297 327 356 383 411
550 60.5 105 145 183 219 253
286
319
350
381
411
441
00 64.2 112 155 195 233 269 305 339 373 405 437 469
TdUr
t
J \
Calculations lor other pipe tlxis can ho nade usini tho data feuad la Tabiis IV aad V. No lla CMflkkHti wiro calculated lor Qow ratos wbori tbo Royaolds auathor was lots thaa 2100.
67
TOWOLDMONOQ26147
mfriction losses
system fifing
AHOCLOH 1248, ABOVE SWF.
:|
HEAD LOSS, FT. PER 100 FT.
lI
i! ?1
*8
TOWOLDMONOQ26148
* TYPICAL HEATEBS USING AKOCLOB 1248
A 200,000 Btu. (right) and a 300,000 Btal. heater, both gas-tired, have been in use at Monsanto for over 14 years for organic chem icals reactions. The heaters have operated near 600F. with the same charge of Arodor 1248 for periods of 7 years.
29
TOWOLDMONOQ26149
J
f
i
( Aredor Hoitor: The heater consists of fire brick lined walls and bottom i inside a steel shell with steel baffles to force the hot combustion j gases for three passes over the Arodor coil. The top is a steel plate.
Ceeler: Two-stage shell and tube construction with the Arodor 1248 on the outside of the tubes. The two-stage cooler is piped so that one stage can be used on each Arodor heater or both stages can be used on either Arodor heater.
0221508
TOWOLDMONOQ26150
A 40,000 Btu. per hour electrically heated portable heat exchanger used to heat vessels of about 50 gallons workingcapac ity. This unit was built for a variety of small scale chemical reactions. It was initially designed to vaporize approxi mately 200 lbs./hr. of an organic com pound which has a heat of vaporization of 150 Btu. per pound; a 30% heat loss was allowed for. Experience with the heater indicates that a horizontal rather than the vertical mounting of the immer sion heater (at operator's left) would have been more satisfactory.
A 4,000,000 Btu./hr. forced drculatiOB International LaMont heater.
Control panel for a 3,000,000 Btu./hr. International LaMont heater that oper ates the 3,500 gallon, glass-lined kettle shown on the left This kettle is the largest of its kind in the United States.
Commercial heaters operating on Axactor are available tn any capacity 4*v'd
1*wt it a l.?QU0M) B>e ** mtta'Ut.gn.
)
i
TOWOLDMONOQ26151
0221^09
(Photo Coortrsy Udnm Inin Wiwln)
A pilot plant resin processing msd operated on imfirect beat transferred by Arodor 1248. Vessel and beater are mounted together in one unit
This 500.000 Btu./hr. forced circulation heater is electrically heated and designed for a liquid temperature of 500F. The construction is similar to a double pipe heat exchanger with the electric heating elements in the inner pipe; the Arodor 1248 circulates through the annular space between inner and outer pipe. The liquid Arodor 1248 is delivered from the heater at a temperature of SOO'T. and heats the contents of a jacketed kettle with a batch capacity of 1.000 gallons.
*
This design for a forced drculation heater was de veloped by Cleaver Brooks Company.
miat.miti: cited
1. Monsanto Chemical Co., St. Louis, Mo., Application
Data Bulletin 0-U5 (1954).
.
2. Sullivan, M. V., Wolfe, J. K., and Zisinan, W. A., "Indus. Eng. Chem." 39, 1607 (1947).
3. Granet, II, "Heat Transfer Performance Curves'*, Chemical Engineering, P. 187-190, March, 1955.
4. McAdams, W. H., "Heat-Transmission", McGraw-Hill Book Co., Inc., New York, (1942). ,
5. Kem, D. Q., "Process Heat Transfer", McGraw-Hill Book Co., Inc., New York, (1950).
0221510
TOWOLDMONOQ26152
<- <J \J..i J Jl
LIQUID HEAT TRANSFER FLUID
Temperatures up to 600F. Long-lasting, trouble-free Service Fire-resistant, non-corrosive Operates in un-pressured, minimum cost equipment Monsanto supplies Aroclor I24S, but not the heat exchangers. Monsanto will be happy to recommend sources of supply.
0221511
TOWOLDMONOQ26153
s V.
f l ;-
i j
1
Regional Offices: ATLANTA BOSTON
C4 o
CHICACO
iIVl__ i
CINCINNATI CLEVELAND
DETROIT
HOUSTON
LOS ANCKI.ES
MONSANTO CHEMICAL COMPANY
NEW YORK SAN FRANCISCO
ORGANIC DIVISION ST. LOUIS, MO.
SEATTLE ST. LOUIS MINNEAPOLIS-.ST. PAUL WILMINGTON
0*9*44 LITMO IN V I A
TOWOLDMONOQ26154