Document k6RVEGQGxVdxXG0ooZmN206GE
Air Conditioning, Automatic Heating Systems
Gar Wood Industries, Inc.
AIR CONDITIONING DIVISION
7924 Riopelle St., Detroit, Mich.
Licensed Distributors in All Principal Cities
TEMPERED-AIRE UNIT
The Tempered-Aire heating and air-conditioning equipment made in five (5) capacities, consists of filters, blower, burner, humidifier, and oil furnace engineered into one compact, coordinated system.
Clean, humidified, warmed air is delivered from the unit to the duct system and then uniformly distributed to all parts of the building.
Air is cleaned by dry cloth filters and circulated by a multiple-blade blower fan. The heating unit is a down-draft, warm-air furnace equip ped with an integral pressure atomizing type oil burner. The humidifier, located at the top of the unit, is designed integrally with the furnace.
Tempered-Aire Ratings and Dimensions No. 102
Air Temperature at Bonnet........................ Oil Kate. Gallons t hour............................ Heating Surface, Firebox, sq ft.................. Heating Surface, Economizer, sq ft........... Total Heating Surface, sq ft......................
Motor Horse Power--Burnftr..................... Motor Horse Power--Blower..................... Overall Length. Inches............................... Overall Width. Inches................................
120,000 100,000 1000-1575 175--135
1.20 30 60 90 24
1/6
1/5 96% 40'/,
No. 102A
120,000 100 000 1000^-1575 I75M350
1.20 30 60 90 34 1/6 1/5 92'/. 38'/,
No. 103
165.000. 135,000 1375-2150 175-135
1.65 33 99 132 43 1/6 1/3 117% 38
No. 104
225,000 185,000 1875-2950 175--135
2.25 44 132 176 60 1/6 1/2 140% 38
No. 105
300,000 245,000 2500-3925 175--135
3.00 55 165 220 77 1/6 3/4
156% 38
No. 105C
400,000
3000-4500 I85-145
4.00 55 165 220 77 1/4 1
156% 38
MODEL EW UNIT
A complete winter air conditioning unit for moderate cost homes. It comes in one (1) size, with pressure atomizing type oil burner, refrac tory combustion cham ber, star shaped transfer chamber, washable cloth filters, multivane blower and humidifier.
RATINGS AND DIMENSIONS MODEL EW
Btu 1 hour at Bonnet....................... 100,000 Btu 1 hour at Grilles.......... ................80,000 Air Delivery CFM........................... 800-1200 Air Temp, at Bonnet.....................175 - 135 Oil Rate Gal per hour..............................1.00 Heating Surface Firebox...............5.5 Sq Ft Heating Surface Trails. Chamber, 74.5 Sq Ft Heating Surface Total.... ................80 Sq Ft Filter Area......................................25.5 Sq Ft Min. Width Door to admit unit........29 in.
GAS FIRED TEMPERED-AIRE
Built in a single unit, it provides air filtering, blower cir culation,
humidifyi n g and heating. F urnace is made of heavy gauge cop per bearing steel. Thermostatically opera ted. Safety controls give full protection. Approved by Amer. Gas Assoc.
AGA Output, Btu per hour......... Grille Delivery Btu per hour.......
Blower Motor Current Consump.
No. 90
135,000 101,250 90,000 900-1425
34 1/5 bp 250 Watts 96%
40
No. 120
180,000 135.000 120.000 1200-1900
34 l/5hp 250 Watts 96& 40
900
Gar Wood Industries, Inc. Air Conditioning, Automatic Heating Systems
MODEL "R" BOILER-BURNER UNIT
A compact firetube steam or hot water heating boiler, with an integral oil burner.
Boiler built of heavy rust-resisting boiler plate, electrically. welded. The combustion chamber walls are carried clear to the crown sheet. The result is a considerably higher temperature of fire than is found in the conventional boiler, and better com bustion of No. 3 oil.
Since there are no water legs, the bulk of the heating surface is concentrated in the firetubes, or secondary heating surface, resulting in maximum extraction of heat from the hot gas which leaves the firebox and consequent low stack temperature, high efficiency and operating economy.
Burner Model
Firing Rate--Gal per Hour................................ Maximum Net Steam Load--Sq Ft...................... Maximum Net Hot Wgjter Load--Sq Ft.............. Maximum Gross Steam Load--Sq 11................... Maximum Gross Mot Water Load--Sq ht........... Heating Surface--Sqh t.................................. Overall width--Jacket........................................... Overall Length-Jacket.......................................
R500 H
1.65 500 800 750 1200 52 30% 53
R750 H
2.50 750 1200 1125 1800 68 30% 65
R1000 D
3.25 1000 1600 1500 2400 84 37% 59%
R1400 D
4.50 1400 2240 2100 3360 118 37% 66
RIS00 D
6.00 1800 2880 2700 4320 154 37% 80
VENTILATOR
A silent op erating venti lator--attic or commercial use. Ventilator consists of beltdriven propel ler type fan; electric motor with overload protection; metal hous ing; automatic shutter; insect screen; canvas connection and clamps; suspension springs. 8 Sizes: 20 in. to 60 in. CFM: 3500 to 30,000.
INDIRECT AIR CONDITIONING EQUIPMENT
Made in eight (8) sizes. Consists of a compact cabinet unit containing cloth air filter and vapor mist filter, blower, hu midifying chamber, and indirect, blast heater.
While designed par ticularly for use with Gar Wood Boiler-Burner Units (steam, vapor, or hot water), the air con ditioning unit may be used effectively with any adequate existing plant.
OIL-FIRED WATER HEATERS
Commercial Type--An attractive, quiet operating balanced unit, in 2 sizes. Bums No. 3 fueloil. Fully auto matic. Separate tank. Capacities: 200 and 300 gal per hour 100 F tem perature rise. Over allwidths: 28Min.; lengths:49in.-6l in.
Domestic Types--Model S50 --coil type heater for use with separate storage tank. Cap. 50
gal per hour 100 F temperature rise. Model S40 has storage tank integral. Cap. 40 gal per hour 100 F ternperature rise. Both Ifi'l J
types have vertical -I % rotary burner with J* j m
only one moving EgjjjssjS
part and for use with
No. 2 or lighter oil. Model S60 Model S40
Highly efficient for installation in existing heating plants. Pres sure atomizing type. Simple in design. Han dle No. 3 fuel oil. Sturdy, quite, easily accessible. Fit any shape of firebox.
CONVERSION OIL BURNERS
Model "W"
418-8600 sq ft net steam radiation.
Model'"K'-' 418-8600 sq ft net
steam radiation.
Model "/T* Up to 686 sq ft net
steam radiation.
901