AMERiCAN-fStandard i.lm. /j/W Hydronic Heating Equipment trade price book fl Hydronics . .. the science of heating and cooling with water. Boilers: PRODUCTS Gas--Packaged Units Boilers Only Electronic Control Systems Oil --Packaged Units Boiler--Burner Units Boilers Only Stoker Boilers Hand fired Boilers Radiation: Baseboard Panels --Radiantrim --Heatrim Convectors --Multifm --Arco --Cabinet Extras Radiators--Arco, Sunrad, Peerless Oil Burners and Controls Zone Valve Packages Repair Parts Discounts Terms General Information PAGE 3-6 7-14 15 16-18 19-27 20-27 31-33 34-36 38 39-40 42-44 41 45 37 28-30 30 2 46 2 r HH-4 JANUARY 1, 1964 notice: The Trade Prices shown herein do not include freight or cartage, installation or any local taxes. IAMERiCAN-<$tandard PLUMBING AND HEATING DIVISION AMERICAN RAOIATOR i STANDARD SANITARY CORPORATION 40 WEST 40TH STREET NEW YORK, N Y. TOOTS 01664 GENERAL INFORMATION American-Standard HYDRONIC HE ATIN Q BOILER RATINGS Botler ratings ("net I~B = R ratings of Mbh and sq ft of steam", "net fating sq it water" and `'installed radiation", connected to the boilers. Steam sq ft ratings are based on 240 Btu per sq ft and water sq ft ratings on 150 Btu (170* water) per sq ft. Allowances have been made in these ratings for normal piping (covered) and pick-up loads and for heat ing domestic hot water under the following conditions: It is not necessary to increase the boiler size for domestic hot water supply when not more than two bathrooms are to be served or if the use of domestic hot water does not exceed seventy-five gallons m twenty-four hours. Sufficient radiation must be installed for the requirements of the building. In order to select the proper size boiler calculate the heat loss of the building, then divide this figure by l.000 to get the lieac iusa CApitMeu ill muii. ocicuk a Steam vi wavci uoiiei which has a net Mbh rating equal to or greater than this fig ure using the appropriate steam or water column. See current literature for determining the size of radiators and convectors for hot water systems. For an installation where unusual conditions such as large pipe losses, intermittent heating, unbalanced systems, etc., are encountered, it is suggested to calculate the actual piping loss and estimate the pick-up factor to adjust the load and then select the boiler from the published gross output in Mbh (1,000 Btu per hour). GAS FIRED BOILERS The input and output ratings are approved by the American Gas Association. Ratings shown are for installations at sea level and at eleva tions up to 2.000 feet. For altitudes above 2.000 feet, ratings should be reduced at the rate of 4% for each 1,000 feet above sea level. OIL FIRED BOILERS The firing rates or I=B=R burner capacities--gallons per hour -are based on the use of oil having 140.000 Btu per gallon heat value, and with 10% CO2 in the flue gas. When more than two bathrooms are to be supplied with domestic hot water or when the demand for domestic hot water exceeds seventy-five gallons in twenty-four hours in crease the boiler size 120 Btu per hour for each gallon of stor age tank capacity. When Built-in Tankless Heater is used increase the boiler size 12 Mbh for each bathroom in excess of two. STOKER FIRED BOILERS The firing rates or I = B=R burner capacities-pounds per hour -are based on the use of coal having 13.000 Btu per pound heat value. When more than two bathrooms are to be supplied with domestic hot water or when the demand for domestic hot water exceeds seventy-five gallons in twenty-four hours in crease the boiler size 120 Btu per hour for each gallon of stor age tank capacity. HAND FIRED BOILERS The ratings (installed radiation sq ft) are based on the use of stove or nut size bituminous coal, anthracite coal or coke with 13.000 Btu per pound heat value. See table below for select ing proper size boiler when using coal with less than 13.000 Btu per pound. When more than two bathrooms are to be supplied with domestic hot water or when the demand for domestic hot water exceeds seventy-five gallons in twenty-four hours in crease the boiler size 120 Btu per hour for each gallon of stor age tank capacity. BUILT-IN WATER HEATERS for A-3, A-5. (A-7i Severn and Exbrook Boilers Ail tank type built-in water heaters are rated on the basis of raising the temperature of the domestic hot water 100F. in three hours with a minimum boiler water temperature of 180*F. on automatically fired boilers and 212#F. on hand fired boilers. All tankless type built-in water heaters are rated in gallons per minute on the basis of a minimum botler water tempera ture of 180*F. on oil fired boilers. The maintaining of 180*F. boiler water temperature with rated flow through a tank less type built-in water heater is dependent on the oil firing rate for the boiler. In those areas where excessive lime exists in the water, use of built-in tankless type water heater is not recommended except when provision is made for regularly cleaning the heater. Use of tank type heater is recommended in hard water areas. WHEN PIPING LOSS IS NEGLIGIBLE The load connected to automatically fired water boilers may be increased by 12% when the piping loss of the installation is negligible. The load connected to steam boilers (all fuels) and coal (hand fired) water boilers may be increased by the percentages shown below when the piping loss of the installa tion is negligible. load Installad radiation sq ft Staam (all fuals) Watar coal (hand fired) increase load by up to 250 251- 500 501-1000 1001-1500 1501-2000 2001-3000 3001-4000 over 4000 u p to 400 401- 800 801-1600 1601-2400 2401-3200 3201-4800 4801-6400 over 6400 30% 28% 24% 21% 18% 15% 13% 12% WHERE COAL HAS LESS THAN 13,000 BTU CONTENT When selecting hand fired boilers for burning coal of lower heating value than 13.000 Btu per pound the following correc tion factors should be used. Multiply the net load by the proper factor and select the boiler with the corresponding rating (installed radiation sq ft). heating value of coal correction factor 13.000 ............... 1.00 12.500 ..................1.04 12.000 .................... 1.08 11.500 .................... 1.13 11.000 .................. 1.18 heating value of coal correction factor 10.500 1.24 10.000 . .1.30 9,500................. 1.37 9,000.....................1.44 INSTRUCTIONS FOR ORDERING GAS BOILERS: Specify complete boiler number. Specify type of gas (if IP gas, whether butane or propane), Btu (heat value of gas}, specific gravity. Specify elevation at point of installation if in excess of 2,000 feet and indicate barometric pressure. Specify optional equipment in detail. REPAIR PARTS-TRADE PRICES Boilers (all fuels)........................................................................................................................................................ List Price, less 25% Gas Conversion Burners................................................................................ .............................................. List Price, less 25% For List Prices see ''American-Standard Radiatqr Heating Repair Parts Catalog" 1956 Edition. Oil Burners.................................................................................................. ............................................List Price, less 25% _For List Prices see "American-Standard Arcoflame Oil Burner Repair Parts Catalog" 1956 Edition. HH-4 Page 2 fir 7hi* Price List has been prepared for the convenience of American-Standard distributors and their trade cus tomers only The trade prices shown represent fixed markups over d.sinbutor pnees to reflect reasonable sel)- * and disinbuuon expense and do not purport to represent actual prices prevailing in any particular mar 01665 WATER piekigtd boiler number GPR-60 GPR-80 WATER GPR-60 GPR-80 AmeRICAN-$tandard HYDRONIC HEATING packaged boilers AS GPR PACKAGED AMERlCAN-,$tandard GAS BOILERS Desisted -r.d equipped w;ib ccr.trolo Tot luiceu cncuiauun. Factory assembled and crated. Built-m air-separator in top section. A G A. approved for combustible floor and closet installations Controls regularly furnished for 115 volt, 60 cycle current. Ratings shown are for installations at sea level and up to 2,000 feet. for Natural, Manufactured, Mixed, Gas controls arranged for noni00% shut-off A.G.A. input Mbh 75 100 A.G.Ae output Mbh II** net rating sq. ft. water Trade Price with standard equipment chimney size diameter inches height feet 60 45 300 $225.00 5 20 80 60 400 245.00 5 20 for Propane and Butane Gas controls arranged for 100% shutoff approx. shipping weight 205 235 70 56 42 280 $225.00 5 20 205 95 76 57 380 245.00 5 20 235 Standard equipment all boilers: V-600 combination diaphragm gas valve furnished for all gases V-600 fea tures built-in gas pressure regulator `except for LP gas) and thermocouple type safety pilot switch. Manual shut-off valve; pilot cock; pilot filter 'for manufactured gas and S.U.R.); drain valve; draft hood; insulated round jacket; transformer; ASME relief valve <30 lbs.); pressure and temperature gauge (30 IbsJ; wiring harness; 1" circulator; CB-58009 thermostat; AY-553 and AY-686 limit controls with HI-LO limit selector switch. Ordering Eumplet: 1. Packaged boiler with standard equipment: 1 GPR-60 boiler Nat. gas, 1000 Btu, .6 sg. 2. Packaged boiler with optional equipment: 1 GPR-80 boiler with pilot filter with self* energizing controls Mfd. gas, 550 Btu, .65 sg. Notes: For ordering instructions, see page 2. For complete information on boiler ratings, see pege 2. For discount on repairs, see page 2. Hole: Packaged boilers are shipped with jacket, all controls (except thermo stat), circulator, mam burners and manifold controls and piping factory in stalled and wired. CB-58009 thermostat, manual shut-off valve, relief valve and draft hood shipped inside boiler crate. Optional equipment: Pilot filter for natural or mixed gas furnished at no charge when specified on order to meet local utility codes. Self-energizing controls (consist of special gas valve, thermostat, pilot burner, limit control) for all gases listed above, available when specified on order at no additional charge. Note: In areas where manual opening feature is normally desired. GPR boil ers are furnished with self-energizing controls as shown above V-600 gas valves with manual opening for GPR not available. Zone valve packages are available for water boilers. For details and prices, see page 30 Page 3 This Price List has been prepared for the convenience of American-Standard distributors and their trade cus tomers only The trade prices shown represent fixed markups over distributor prices to reflect reasonable selling and distribution expense and do not purport to represent actual prices prevailing in any particular market HH * 01666 PACKAGED BOILERS GAS FIRED WATIK American -<S\ andard HYDRONIC HEATING GPH PACKAGED American Standard GAS BOILERS Designed and equipped with controls for forced circulation. Factory assembled and crated Square jacket. Built-in air-separator in top section. A G A approved for combustible floor and closet installations. Controls regularly furnished for 115 volt, 60 cycle current. Ratings shown are for installation at sea level and up to 2.000 feet. WATER for Natural, Manufactured, Mixed, Gas pckaid boilor numbtr A.GJL input Mbh AeGJL output Mbh not l=B=R ratine Mbh not ratine sq ft wator Trad# Prtco with standard oquipmont GPH-100 GPH-135 GPH-170 125 100 75 500 $280.00 169 135 101 673 340.00 213 170 128 853 400.00 chimnoy ixa diamotor Inchos hoietrt fact 6 20 7 20 7 20 for Propane and Butane Gas GPH-100 GPH-135 GPH-170 120 96 72 480 $280.00 6 20 160 128 96 640 340.00 7 20 200 160 120 800 400.00 7 20 approx. shippine woicht 315 360 400 315 360 400 Standard equipment all boilers: V-600 combination diaphragm gas valve, arranged for 100% shut-off, fur nished for natural, mixed and LP gases. V-600 features built-in gas pressure regulator (except for LP gas) and thermocouple type safety pilot. Manual shut-off valve; pilot cock; pilot filter (for manufactured gas and S.U.R.); drain valve; draft hood; insulated square jacket; transformer; ASME relief valve (30 lbs); pressure and temperature gauge (30 lbs); wiring harness; iy" circulator; CB-52502 thermostat; AY-553 and AY-686. limit controls with HI-LO limit selector switch. Non-100% shut-off with self-energizing controls furnished for manufactured gas. Self-energizing controls consist of special gas valve, thermostat, pilot burner and limit controls. Ordering Eumplei: 1. Packaged boiler Kith standard equipment: 1 GPH-135 boiler Mfd. gas, 550 Btu, .65 sg. 2. Packaged boiler with optional equipment: 1 GPH-100 boiler with self-energizing controls Propane Gas Notes: for ordering instructions, see page 2. For complete information on boiler ratings, see page 2. For discount on repairs, see page 2. Neta: Packaged boilers are shipped with jacket, all controb (except thermo stat), circulator, main burners and manifold controb and piping factory installed and wired. CB-52502 thermostat: manual shut-off valve and relief valve shipped inside boiler crate. Draft hood shipped separately. Optional equipment: Pilot Filter for natural or mixed gas furnished at no charge when specified on order to meet local utility codes. Self-energizing controls (consist of special gas valve, thermostat, pilot burner, limit control) for all gases listed above, available when specified on order at no additional charge. Note: In areas where manual opening feature is normally desired, GPH boil ers are furnished with self-energizing controb as shown above. V-600 gas valves with manual opening for GPH not available. Zone valve packages are available for water boilers. For detaib and prices, see page 30. HH-4 Page 4 This Price List has been prepared for the convenience of American-Standard distributors and their trade tomers only The trade prices shown represent fixed markups over distributor prices to reflect reasonable s* md d ixinbui ion expense and do not ourport to represent aciual prices prevailing in any particular mi 01667 American-^Standard HYDRONIC HEATING PACKAGED BOILERS GAS FIRED WATtt WATER G-2 PACKAGED American-Standard GAS BOILERS Designed and equipped with controls for forced circulation. Factory assembled and crated. Deluxe jacket. Sections tested for 30 Lbs. water working pressure. "Elirmnatre" (eastern air separator in left end section). Controls regularly furnished for 115 volt. 60 cycle current. Ratings shown are for installation at sea level and up to 2.000 feet. packaged boiler number a.qjl input Mbh A.G.A. output Mbh tankless heater number l=WsH rating Nat., Mfd.. Mixed and LP Gas: LP-AIr Gas 525-1400 Btu net l=B=R rating Mbh net rating sq ft water Trade Price with standard equipment chimney size diameter height inches feet approx. shipping weight Packaged boilers with factory installed tankless heater G-24-DPT G-25-DPT G-26-DPT G-27DPT 90 120 150 180 72 218 2 Vi 96 222 3 120 222 3 Vi 144 222 3 Vi 54 72 90 108 360 480 600 720 $375.00 421.00 464.00 500.00 5 20 390 6 20 470 6 20 550 6 20 642 Packaged boilers without tank less heater G-23-DP 60 48 G-24-DP 90 72 G-25-DP 120 96 G 26-DP 150 120 G-27-DP 180 144 36 240 54 360 72 480 90 600 108 720 $285.00 342.00 386.00 429.00 465.00 Gallons ot water per minute neated from 40F to 140F with 200F ootler water temperature. 4 20 315 5 20 375 6 20 455 6 20 540 6 20 630 Standard equipment all boilers: V-600 combination diaphragm gas valve furnished for Natural. Manufactured. Mixed. LP-Air. and LP gas boilers. V-600 features built-in gas pressure regulator iexcept for LPGas) and thermocouple type safety pilot switch Manual shut-ofT valve; Pilot cock. Pilot filter (for manufactured gas and S.U.R.); Drain valve; Draft hood; Insulated jacket; Transformer; ASME relief valve (30 lbs 1; Pressure and temperature gauge (30 lbs); Wiring Harness; 1V4" circulator with piping. Additional standard equipment for boilers with heater: Tankless heater as listed above. combination immersion control (high and low limits, circulator operation, transformer and built-in relay), CB-52502 thermostat. Additional standard equipment for boilers less heater: CB-52502 thermostat, combination immersion high limit and reverse acting control. Left hand end section without tankless heater opening. Note: Packaged boilers are shipped with jacket, all controls (except thermostat), cir culator and piping, mam burners and manifold controls and piping factory installed and wired. CB-52502 thermostat, manual shut-off valve and relief valve shipped fastened inside boiler crate. Draft hood shipped in separate carton for G-23-DP Ortirlng Eumplti: 1. Packaged boiler without tankless with stand ard equipment: 1 G-24-0P boiler Nat. gas, 1000 8tu, .6 sg. 2. Packaged boiler with factory installed heater with optional equipment: 1 G-26-DPT boiler with push button elec tric ignition Mfd. gas. 550 Btu, .65 sg. Notes: For ordering instructions, see oage 2 For optional equipment, see page 9. For complete information on boiler ratings, see page 2. For discount on repairs, see page 2. Page 5 This Price List has been prepared for the convenience of American-Standard distributors and their trade cus tomers only The trade prices shown represent fixed markups over distributor prices to r and distribution expense and do not purport to represent actual prices prevailing in 01668 HH-4 PACKAGED BOILERS GAS FIRED WATft Am ericaa1-Standard H YDRONIC HEATING WATER packaged boiler number G-23DPG G-24DPG G-25DPG G-26DPG G-27DPG G-2 PACKAGED ALL-PURPOSE A.MtRICA\'-<$iandaiil GAS BOILERS Designed for forced or gravity circulation. Factory assembled and crated Deluxe Jacket. Sections tested for 30 lbs. water working pressure. "Eliminaire" (cast-in air separator in left end section). Controls regularly furnished for 115 volt. 60 cycle current. Ratings shown are for installation at sea level and up to 2.000 feet. A.GA. input Mbh A.G.A. output Mbh Nat., Mfd.. Mixed and LP Gas; LP-Air Gas 525-1400 Btu net l=B=R rating Mbh 60 48 36 90 72 54 120 96 72 150 120 90 180 144 108 net rating sq ft water 240 360 480 600 720 Trade Price with standard equipment less thermostat chimney site diameter inches height feet $208.50 4 20 265.50 5 20 309.50 6 20 350.50 6 20 386.50 6 20 approx. shipping weight 317 377 457 542 632 HH4 Standard equipment: V-600 combination diaphragm gas valve furnished for all gases. V-600 fea tures built-in gas pressure regulator (except for LP Gas) and thermocouple type safety pilot switch. Manual shut-off valve; pilot cock; pilot filter (for manufactured gas and S.U.R.); dram valve; draft hood; insulated jacket; transformer. G-23-DPG furnished without heater opening tn left end section. ASME relief valve; pressure and temperature gauge; CB-65653 immersion limit control. Draft hood shipped in separate carton for G-23-DPG. Ordering Examples: 1. Packaged all-purpose boiler with standard equip ment. 1 G-25-OPG boiler Nat. gas. 1000 Btu, .6 sg. 2 Packaged all-purpose boiler with optional equip* ment; 1 G-26-DPG boiler with self-energizing controls 1 222 tankless heater * Mfd. gas, 550 Btu, .65 sg. Notes: For ordering instructions, see page 2. For optional equipment, see page 9. For complete information on boiler ratings, see page 2. For discount on repairs, see page 2. Page 6 This Price List has been prepared for the convenience of American-Standard distributors and their trade cus tomers only The trade prices shown represent fixed markups over distributor prices to reflect reart*'*hi* #Uine and distribution exornsc and do not purport to represent .iciual prices prevailing in any par' 01669 American-Standard HYDRONIC HEATING BOILERS--GAS FIRED STEAM and WATER G-2 NOi'J-vPACKAGED ALL-PURPOSE American-^Standard GAS BOILERS Designed lor water (forced or gravity) or steam. Flush or Deluxe jacket. Factory Assembled Sections. Sections tested for 30 lbs. water working pressure. "EUminaire" (cast-in air separator m left end section). Controls regularly furnished for 115 volt. 60 cycle current. Ratings shown are for installation at sea level and up to 2.000 feet. WATER (Available with factory installed Tankless heater, see options, page 9.) bofftr number A.G.A. input Mbh A.GJL. output Mbh Nat., Mfd.. Mixed and LP Gas; LP-Air Gas 52S-1400 Btu net tsBsR rating Mbh net rating q ft water Trade Price with standard equipment less thermostat flush jacket deluxe jacket chimney size diameter inches height feet approx. shipping weight G-23-*W G 24-*W(T) G 25-*W(T) G 26-*W(T) G-27-*W(T) G 28 *W(T) G 29 *W(T) G-210*W(T) G-211-*W(T) 60 90 120 150 180 210 240 270 300 48 72 96 120 144 168 192 216 240 36 54 72 90 108 126 144 162 180 240 360 480 600 720 840 960 1080 1200 $187.00 244.00 288.00 329.00 365.00 409.00 451.00 482.00 528.00 $201.00 258.00 302.00 343.00 379.00 423.00 465.00 496.00 542.00 4 5 6 6 6 7 7 7 7 20 277 20 353 20 428 20 490 20 553 20 629 20 697 20 761 20 841 Substitute letter 'T" for flush or "O" for deluxe jacket. Suffix 'T" denotes forced circulation boiler equipped with factory installed tankless heater (see page 9 for added charge). STEAM _______ boiler number A.G.A. input Mbh A.G.A. output Mbh Nat.. Mfd.. Mixed and LP Gas; LP-Air Gas S25-1400 Btu net l=6ssR rating Mbh sq ft Trade Price with standard equipment less thermostat flush jacket deluxe jacket chimney size diameter inches height feet approx. shipping weight G-23-S G-24--S G-25-*S 60 48 36 90 72 54 120 96 72 150 $224.00 $238.00 225 281.00 295.00 300 325.00 339.00 4 5 6 20 287 20 363 20 438 G-26-*S G-27--S G-28--S 150 120 90 180 144 108 210 168 126 G-29-*S 240 192 144 G210--S 270 216 162 G-211*S 300 240 180 375 450 525 600 675 750 366.00 402.00 446.00 488.00 519.00 563.00 380.00 416.00 460.00 502.00 533.00 579.00 6 6 7 7 7 7 20 500 20 563 20 639 20 707 20 771 20 851 Substitute letter "F" for flush or "D" for deluxe jacket. Standard equipment: V-600 combination diaphragm gas valve furnished with all sizes Natural. Mixed. LP-Air. LP gas boilers and G-23 through G-2? Manufactured gas boilers V-600 features built-in gas pressure regulator (except for LP Gas> and thermocouple type safety pilot switch. V-532 diaphragm gas valve furnished for all gases for sizes not listed above with separate gas pressure regulator lexcept LP) and Baso switch. Manual shut-off valve; pilot cock; pilot filter (for manufactured gas and S U R ); drain valve; draft hood: in sulated jacket; transformer.Draft hood shipped in separate carton for G-23-D. For water boilers only: ASME relief valve; pressure and temperature gauge; CB-65653 immersion limit control. For steam boilers only: Steam gauge; ASME safety valve; CB-450552 boiler pressure limit control; gauge glass with trimmings; external resetting low water cut-off; floor pan. Ordering Examples: 1. Non-packgged all-purpose water boiler standard equipment and Hush jacket: 1 G-27 FW boiler Nat. gas, 1000 Stu. .6 sg. with 2. Non-paekaged all-purpose steam boiler with op tional equipment and deluxe jacket: 1 G-210-DWT boiler with (1) No. 232 tankless heater installed Nat gas. 1000 Btu. .6 sg. Notes: For ordering instructions, see page 2. For optional equipment, see page 9. For complete information on boiler ratings, see page 2. For discount on repairs, see page 2. Page 7 This Price List has been prepared for the convenience of American-Standard distributors and their trade cus tomers only The trade prices shown represent fixed rr jrkups over distributor prices to reflect reasonable selling end distribution expense and do not purport lo represent actual prices prevailing in anv nart.e..i..------ --- HH 4 01670 aOIURS-GAS FIRED WATIB AMD STtAM American-^Standard HYORONIC HEATING G-2 NON-PACKAGED ALL-r'JRPOSE AMERlCAN\Standard GAS BOILERS HH-4 POP USE WITSI "BW" EQUIPMENT DIRECT TYPE -- Wofee fctoi/erx for hof wafer supply Flush or Deluxe jacket. Hydrostatically tested at 200 lbs. Working pressure 80 lbs. Not recommended for use in hard water areas. Controls regularly furnished for 115 volt. 60 cycle current. Eatings shown are for installation at sea level and up to 2.000 feet. boiler number G-23-W G-24--W G-25-*W G-26--W G-27-W G-28-*W G-29--W G-210--W G-211--W A.QJk. input Mbh A.G.A. rating-gallons water per hour output Mbh 60* rite SO* ri 100* rtaa Nat., Mfd., Mnad and IP Gas; IP-Air Gat 925-1400 Btu 60 90 120 150 180 210 240 270 300 48 72 96 120 144 168 192 216 240 96 144 192 240 288 336 384 432 480 72 108 144 180 216 252 288 324 360 58 86 115 144 173 201 230 260 288 Trade Price with "OW" equipment flush jacket $201.00 258.00 302.00 343.00 379.00 423.00 465.00 496.00 542.00 deluxe jacket $215.00 272.00 316.00 357.00 393.00 437.00 479.00 510.00 556 00 approx. shipping weight 277 353 428 490 553 629 697 761 841 Substitute letter "F" for flush or "0" for deluxe jacket. "DW" standard equipment: In addition to boiler for water with "standard equipment" page 7. "DW*' boilers are furnished with pressure gauge; 80 lb ASME relief valve instead of 30 lb valve; im mersion operating control for use m storage tank; tank thermometer; name and rating plate for 80 lbs. working pressure Ordering Examples: 1. Non-packaged all-purpose water boiler with standard equipment and flush jacket for hot water supply: 1 G-24-FW boiler with "DW" equipment Nat. gas. 1000 Btu, .6 sg. 2. Non-packaged all-purpose boiler with optional equipment and deluxe jacket for hot water supply. I G-25-DW boiler with 'DW'' equipment with manual opening feature on V-600 valve Nat. gas. 1000 Btu . 6 sg. FOR USE WITH "IS" EQUIPMENT INDIRECT TYPE -- Sfeom boilers for hot water supply Flush or Deluxe jacket. boiler number A.GJk. input Mbh A.G.A. rating--gallons water per hour output Mbh 60* rise 80* rise 100* rise Nat-. Mfd.. Mixed and LP Gas: LP-Air Gas 525-1400 Btu Trade Price with "IS" quiprnent flush jacket deluxe jacket approx. shipping weight G-23*S G-24--S G-25*S G-26-*S G-27--S G-28-S G-29-*S G-210--S G-211-*S 60 48 90 72 120 96 150 120 180 144 210 168 240 192 270 216 300 240 96 144 192 240 288 336 384 432 480 72 108 144 180 216 252 288 324 360 58 86 115 144 173 201 230 259 288 $234.00 291.00 335.00 376.00 412.00 456.00 498.00 529.00 575.00 $248.00 305.00 349.00 390.00 426.00 470.00 512.00 543.00 589.00 287 363 438 500 563 639 707 771 851 Substitute latter '*F`' for flush or "O'* for deluxe jacket. "IS" standard equipment: In addition to boiler for steam with "standard equipment" page 7. "IS" boilers are furnished with immersion operating control for use in storage tank. Ordering Examples: Non-packaged all-purpose steam boiler with l. Non-packaged all-purpose steam boiler with optional equipment with flush jacket for hot standard equipment with deluxe jacket for hot water supply: water supply: 1 G-24-FS boiler with "IS" equipment 1 G-26-0S boiler with "IS" equipment with runner type pilot ignition Nat. gas, i-l'D Btu, .6 sg. Nat. gas, 1000 Btu, .6 sg. Notes: For ordering instructions, see page 2. For optional equipment, see page 9. For Complete information on boiler ratings, see page 2. For discount on repairs, see page 2. Page 8 This Price List has been prepared for the convenience of American-Standard distributors and their trade cus tomers only The trade prices snown represent fixed markups over distributor prices to reflect reasonable selling and distribution expense and do not purport to represent actual prices prevailing in any particular market. 01671 American-^Standard HYDRONIC HEATING G-2 OPTIONAL EGwlPMENT BOILERS--GAS FIRED STEAM AND WATER ALL BOILERS Page* S thru 8: Runner type pilot ignition for use with listed gases furnished at no charge when specified on order to meet local utility codes Push button electric ignition for use with listed gases. Not available with sclf-cnergizing controls. Specify on order and add $11.85 to Trade Price of boiler. Floor shield for combustible flooring. Add suffix letter "C" to boiler number and add $3.00 to Trade Price of boiler. Pilot filter for natural or mixed gas furnished at no charge when specified on order to meet local utility codes. Manual opening feature on V-600 or V-532 gas valves fur nished at no additional charge when specified on order to meet local utility codes. Zone valve packages are available for water boilers. For de tails and prices, see page 30. PACKAGED GAS BOILERS Page 5 only: options listed above applicable only to these boilers. PACKAGED ALL-PURPOSE BOILERS Page 6: Tankless heaters: when boilers (4 thru 7 section) are to be used for forced circulation I = W = H tankless heaters can be installed m opening used for gravity tapping flange cover See table below for I=W = H ratings and applicable boiler size Tankless heaters can be ordered shipped separately at the "sold separate" Trade Prices shown below. Self-energizing controls (consist of gas valve, pilot burner, limit control' for mfd . natural and mixed gas. available when specified on order at no additional charge. Special thermostat required, for Trade Price, see page 30. Room thermostat prices shown on page 30. ALL-PURPOSE BOILERS Page 7: WATER BOILERS Factory installed tankless heaters: when boilers (4 thru 11 sec tion) are to be used for forced circulation I=W=H tankless heaters can be specified factory installed. See table below for I-W = H ratings and applicable boiler size. Specify heater, add suffix "T" to boiler number and "factory installed" Trade Price shown below. ALL-PURPOSE BOILERS Page 7: WATER BOILERS (continued) Tankless heaters: when boilers (4 thru 11 section) are to be used for forced circulation I=W^H tankless heaters can be installed in opening used for gravity tapping flange cover See table below for I = W = H ratings and applicable boiler size. Tankless heaters can be ordered shipped separately at the "sold separate" Trade Prices shown below STEAM BOILERS McOonnell-Miller No. 101-24V Electric Water Feeder can be added to the No. 67-G Low Water Cut-off furnished with G-2 All-Purpose Steam Boilers to provide Low Water Cut-off and Feeder Combination. If desired specify on order and add $37.07 to Trade Price of Steam Boiler. Side Outlet ASME Safety Valve may be substituted at no additional charge if specified on order to meet local code requirements. WATER OR STEAM BOILERS Self-energizing controls (consist of gas valve, pilot burner, limit control, low water cut-ofT for steam boilers) for manu factured. natural and mixed gas. available when specified on order at no additional charge. Special thermostat required, for Trade Price, see page 30 Room thermostat prices shown on page 30. Zone circulator control for water boiler with tankless heater and combination immersion control-relay: Use one CB-52502 thermostat and one relay for second and/or third zone. For Trade Prices, see page 30 Dual-gas boilers: available for both natural and propane gases. See below for added charges. Boiler prices on Page 7 boiler no. added charge boiler no. added charge G-23 G-24 G25 G-26 G-27 $50.00 52.00 54.00 56.00 58.00 G-28 G 29 G-210 G-211 $60.00 62.00 64.00 66.00 Equipment includes in addition to standard trim two V-532 gas valves, two manifolds with spuds factory assembled, outdoor changeover control. G-2 Tankless Heaters Ratings boiler number G-24 G-25 G-26 G-27 G-28 G-29 G-210 G-211 A.GJL input Btu/hr. heater 218 |=W=H Rating heater 222 heater 226 heater 232 90,000 120,000 150.000 180.000 210,000 240,000 270,000 300.000 2 Vi -- - - --3 ---- -- 3>/4 -- -- -- 3Vi 4 -- -- 3 Vi 4 Vi -- -- 3 Vi 4 Vi 4 Vi -- 3 Vi 4V4 4 Vi -- 3 Vi 4 Vi 5 Gallons water per minute heated from 40*F to 140*F with 200*F boiler water temperature. Trade Prices heater number factory installed sold seperate 218 $41.00 $19.00 222 43.00 21.00 226 51.00 29.00 232 55.00 33.00 Factory installed additional price includes comb.na tion immersion control-relay packed n trim box- This Price List has been prepared for the convenience of Amencan-Standard distributors and their trade cus tomers only The trade prices shown represent fixed markups over distributor prices to reflect reasonable selling and distribution expense and do not purport to repiesent actual prices prevaihnj ' ' --v.* 01672 BOILERS-GAS FIRED ST(AM ANO WATIft AMERiCAN-^Standard HYDRO M-{ <?s HCATINO G-40 AMERiCAN-<6tandard GAS BOILERS WATER boiler number G-403-W G-404W G-405W G-406-W G-407-W G-408-W G-409-W G-4010W STEAM boiler number G-403-S G-404S G-405-S G-406-S G-407S G-408S G-409S G-4010S WATER boiler number G-403-W G-404W G-405-W G-406-W G-407-W G-408-W G-409W G-4010-W STEAM boiler number G-403-S G-404-S G-405-S G-406-S G-407S G-408S G-409-S G-4010S A.G.A. Input Mbh 150 225 300 375 450 525 600 675 A.GJL input Mbh 150 225 300 375 450 525 600 675 A.GJL input Mbh 120 180 240 300 360 420 480 540 A.G.A. input Mbh 120 180 240 300 360 420 480 540 For Built-In Water Heater Arrangement, see page 11. Deluxe !acl:et Tested and equipped for 50 lbs. water working pressure. Eliminaire" (cast-in air separator in left end section). Controls regularly furnished for 115 volt. 60 cycle current. Ratings shown are for installation at sea level and up to 2,000 feet. for Natural, Manufactured, Mixed, Gas A.GJL output Mbh 120 180 240 300 360 420 480 540 net l=B=R rating Mbh 90.0 135.0 180.0 225.1 270.1 315.1 360.1 405.1 net rating iq ft water 600 900 1200 1500 1800 2100 2400 2700 Trade Price with standard equipment less thermostat $ 360.00 460.00 555.00 675.00 780.00 860.00 940.00 1045.00 chimney slxe dlam. In. ht ft 6 20 7 20 7 20 8 20 8 20 9 20 10 20 10 20 apprei. shipping wsight 827 998 1162 1349 1517 1686 1856 2026 A.GJL output Mbh 120 180 240 300 360 420 480 540 A.G.A. output Mbh 96 144 192 240 288 336 384 432 net l=B=: t rating Mbh SQ ft 90.0 135.0 180.0 225.1 270.1 315.1 360.1 405.1 375 563 750 938 1125 1313 1500 1688 Trade Price with standard equipment less thermostat % 397.00 497.00 592.00 712.00 818.00 897.00 977.00 1082.00 for IP and LP-Air Gas net isBsR rating Mbh 72.0 108.0 144.0 180.0 216.1 252.1 288.1 324.1 net reting sq ft water 480 720 960 1200 1440 1680 1920 2160 Trade Price with standard equipment less thermostat $ 360.00 460.00 555.00 675.00 780.00 860.00 940.00 1045.00 chimney site diam. In. ht ft 6 20 7 20 7 20 8 20 8 20 9 20 10 20 10 20 chimney size diam. in. ht ft 6 20 7 20 7 20 8 20 8 20 9 20 10 20 10 20 approx. shipping weight 858 1027 1195 1370 1544 1713 1880 2050 approx. shipping weight 827 998 1162 1349 1517 1686 1856 2026 A.G.A. output Mbh 96 144 192 240 288 336 384 432 net l=B=R rating Mbh sq ft 72.0 108.0 144.0 180.0 216.1 252.1 288.1 324.1 300 450 600 750 900 1050 1200 1350 Trade Price with standard equipment less thermostat $ 397.00 497.00 592.00 712.00 818.00 897.00 977.00 1082.00 chimney size diam. in. ht ft 6 20 7 20 7 20 8 20 8 20 9 20 10 20 10 20 approx. shipping weight 858 1027 1195 1370 1544 1713 1880 2050 Standard equipment includes: V-531 diaphragm gas valve with manual opening feature; Baso automatic pilot switch for non-100% shut-off (100% shut-off controls for LP-air and LP gases consists of Baso combination pilot switch and valve with auxiliary Baso pilot valves. Optional other gases at no additional charge); manual shut-off valve; pilot Alter (manufactured gas and SUR); gas pressure regulator (except for LP gas); drain valves; pilot cocks; insulated jacket; draft hood; water heater opening cover plates. For water boiler only: ASME relief valve for 50 lbs.; pressure and temperature gauge; CB-65653 immersion limit control. For steam boiler only: Steam gauge; ASME safety valve; CB-450552 boiler pressure limit control; gauge glass with trimmings; external resetting low water cut-off. Ordtriag Cianplu: Notes: 1. Water boiler with standard equipment: 1 &-406-W boiler Nat. gas, 1000 Btu, .6 sg. 2. Steam boiler with optional equipment: 1 G-409-ST 1 No. 226 tankless heater with controls Nat. gas, 1000 Btu, .6 sg. For ordering instructions, see page 2. For optional equipment see page 11. For electronic control panel systems, see page IS. For complete information on boiler ratings, see pege 2. For discount on repairs, see page 2. HH*4 Pag* 10 This Price List has been prepared for the convenience of American*Standard distributors end their trade cus tomers only. The trade prices shown represent fixed markups over distributor prices to reflect reasonable selling ind distribution exDense and do not purport to represent actual prices prevailing m any particular market 01673 AMERiCAN-fStandard HYDRONIC SWEATING BOILERS -- GAS FIRED STLAM AMO WATIR G-40 OPTIONAL EQUIPMENT BOILERS WITH TANKLESS HEATERS: water (for forced circulation! and steam borers can be furnished with tankless heaters. Heaters are limited to boiler sues as shown m ratings table below Specify heater and add suffix "T" to builer number. Tankless heaters with controls for water bolters: Combination immer sion control relay packed m trim box m place of CB-65653 Tankless heaters with controls for steam boilers: additional immersion operating control packed m trim box. If tankless heaters with controls are desired, specify on order with boiler and add to Trade Price of boiler with standard equipment the following charges. Tankless heaters less controls will be furnished when specified at the Trade Prices shown below for heaters only. HUTU NO. 218 222 226 232 44S HEATER WITH CONTROLS Witar $taai $41 00 43.00 51.00 55 00 72 00 $29.00 31.00 3900 43.00 60.00 NEATER ONLY wittr or Stoain $19.00 21.00 29.00 33.00 50.00 Water flow regulators sued for tankless heater involved will be fur nished with heater when specified on order to meat local Utility require ment at $2.00 Trade Price additional charge per heater. Factory assembled sections: G-403 through G-406 can be shipped with sections factory assembled when specified on order. If desired less tankless heater, add S15 00 to Trade Price of boiler. If desired with fac tory installed tankless heater, specify heater number, and add $15.00 plus pnet of heater to Trade Price of boiler. Oual Gas Equipment: available with steam or water boilers for use with Natural and Propane gases only. In addition to standard trim, dual gas equipment includes tube within a tube manifold, two V-532 gas valves, gas pressure regulator (natural gas only), two manual shut-off valves, ribbon burners, 100% shut-off (consists of Baso combination pilot valve and switch with auxiliary Baso pilot valves), pilot cock, outdoor changeover control. Boiler selection should be based on the A G.A. and l^-S --R ratings shown for LP gas. If desireo specify on order and add to Traae Price of boiler with standard trim the following charge. Boiltr Number G-403 G-404 G-40S G-406 Add to Bolter Trade Price $60.00 62.00 64.00 66.00 Belter Number G-407 G-408 G-409 G-4010 Add to Boiler Trade Price $68.00 70.00 72.00 74.00 Electronic Control Systems: available with steam or water boilers. If desired refer to page 15 for complete details end additional Trade Price charges. F.M. end F.I.A. equipment: requires EG-0 or EPG-0 electronic control system and special gas control equipment. Price on application. Try-cock taooincs and valves: if desired for team hosier* tn i<v-i code specify on order and add $4.00 to Trade Price of steam boiler Seff-energizing controls: ave-iabfi* for steam or water (gravity) less tankless heater for natural and mixed gases only. Equipment includes special gas valve, pilot burner i-m.t control, low water cut off for steam boilers. Furnished at no additional cnarge when specified on order Special room thermostat required, for Trade Price see page 30. McOonnell-Mlller No. 101*24 Volt Electric Water Feeder: can be added to No. 67-G low water cut-off furnished with G-40 Steam Boilers to provide low water cut-off and feeder combination. If desired specify on order and add $37.07 to Trade Price of steam boiler McDonnell-Miller Ne. 47*2 lew water cut-off and Nader combination may be specified m place of regularly furnished No 67 0 for steam boilers. If desired specify on order and add $33.00 to Trade Price oi steam boiler. McDonnell-Miller No. 247*2 low water cut-off and feeder combination for water boilers is available with G-40 Water Gas Boilers when specified on order. Add to the Trade Price of the water boiler with regular equipment the current Trade Price of this item shown m the current McOonnell-Miller Price Sheet. Runner type pilot ignition: all sues of G-40 are available with Runner type pilot ignition for natural, manufactured and mixed gas non-100% shut-off at no additional charge when specified on order to meet local Utility codes. Push button electric ignition: all sues of G-40 are available with push button electric ignition for use with natural, manufactured and mixed gas non-100% shut-off and will be furnished when specified on order at $11 85 added charge. Pilot filters for G-40 for natural and mixed gases available at no addi tional charge when specified on order to meet local utility codes. Thermostats available at Trade Prices shown on Page 30 Zone circulator control for water boiler with tankless heater and com bmation immersion control-relay. Use one CB 52502 thermostat and one relay for second and/or third zone For Trade Prices, see page 30 "IS" Equipment: G-40 Gas 8oiiers can be furnished for use with In direct Steam Hot Water Supply systems. CB-65653 immersion operating control for use in storage tank is required and will be furnished when specified on order at extra Trade Price as shown on Page 30. V*532 Diaphragm Gat Valva without manual opening may ba substi tuted for V-531 Gas Valve with manual opening at no additional charge. If desired, specify on order. Side Outlet ASME Steam Safety Valves may be substituted at no addi tional charge if specified on order to meet local code requirements. Jacket Extension: covers all controls on left end of boiler. If desired, specify on order and add $25 00 to Trade Price of Boiler. Approximate shipping weight 36 lbs. Q-40 Tankless Heater Ratings (Gallons per minute*) Boiler G-40) G-404 G-40S (401 G-407 6-401 6-401 G-4010 HEATER 211 Steam Water 34 3Vl 4 3V4 4 3V4 4 3V* 4 3V4 4 3to 4 3V* 4 HEATER 222 Steam Water _-- 4 4Vz 4 4L4 4 4Vt 4 4Vi 4 4V4 4 4V* 4 4* HEATER 22B Steam Water ---- ---- 5Mi 8 5Vi 6 6 6V4 6 6<* 6 6Vi 6 6Vi HEATER 232 Steam Water ---- ---- ---- ---- 7 7V4 7V4 8 7W 8 7V* 8 HUT ER 448 Steam Water ---- ---- ---- ---- ---- tv> 9 Bfe 9 8W 9 Go/loni of wafer per minvfe raxed from 40*F. to 140*F. Page 11 This Price List has been prepared for the convenience of American-Standard distributors and their trade cus tomers only. The trade prices shown represent Axed markups over distributor prices to reflect reasonable <#llma and distribution expense and do not purport to represent actual prices prevailing in any HH'4 01674 tOllERS-GAS FIRED IUAJM AMO WATIB AMERiCAN-cStandard HYDRONIC HEATING WATER Mlir number G-606-W G-607-W G-608-W G-609-W G-6010-W G-6011-W G-6013-W G-6Q15-W G-6017-W G-6019-W G-6021 W G-6022W G-6025-W G-6028-W G-6031-W G-6033-W G-6037-W G-6041-W STEAM boiler number G-606-S G-607-S G-608S G-609-S G-6010-S G-6011S G-6013-S G-6015-S G-6017-S G-6019-S G-6021 S G 6022-S G-6025-S G-6028S G-6031-S G-6033-S G-6037-S G-6041-S A.OA. Input Mbh 725 870 1015 1160 1305 1450 1740 2030 2320 2610 2900 3045 3480 3915 4350 4640 5220 5800 A.GJL input Mbh 725 870 1015 1160 1305 1450 1740 2030 2320 2610 2900 3045 3480 3915 4350 4640 5220 5800 G-60 AMERlCAN*<$tandard GAS BOILERS for Natural, Manufactured, Mixed Gas Jacketed. Tested and equipped for 50 lbs. water working pressure. Available (or 80 lbs. working pressure on special order. Controls regularly furnished for 115 volt, 60 cycle current. Ratings shown are for installation at sea level and up to 2,000 feet. A.&A. output Mbh 580 696 812 928 1044 1160 1392 1624 1856 2088 2320 2436 2784 3132 3480 3712 4176 4640 not IsBsR ratine Mbh 435.1 522.1 609.2 696.2 783.2 870.2 1054.5 1248.3 1438.8 1621.1 1801.2 1891.3 2161.5 2430.1 2701.9 2880.4 3245.3 3602.5 not rating q ft wator 2900 3480 4060 4640 5220 5800 7030 8320 9590 10805 12010 12610 14410 16200 18010 19205 21635 24015 Trade Price with standard oquipmont loss thermostat $ 961.00 1118.00 1283.00 1461.00 1638.00 1783.00 2092.00 2408.00 2711.00 3020.00 3329.00 3533.00 3967.00 4296.00 4895.00 5184.00 5803.00 6421.00 ehimney slxa diam. in. ht ft a 20 12 20 13 20 13 20 14 20 15 20 15 20 16 20 16 30 17 30 18 30 19 30 20 30 2212 30 30 24 30 26 30 26 30 approx. shipping weight 2741 3141 3527 3923 4335 4728 6049 6835 7620 8503 9292 10139 11334 12616 13809 15036 16690 18316 A.&A. output Mbh net IsB sR rating Mbh sq ft Trada Price with standard equipment less thermostat chimney slxa diam. In. ht ft approx. shipping weight 580 696 812 928 1044 1160 1392 1624 1856 2088 2320 2436 2784 3132 3480 3712 4176 4640 435.1 522.1 609.2 696.2 783.2 870.2 1054.5 1248.3 1438.8 1621.1 1801.2 1891.3 2161.5 2430.1 2701.9 2880.4 3245.3 3602.5 1813 S 998.00 ii 20 2176 1155.00 12 20 2538 1320.00 13 20 2901 3263 3626 1498.00 13 20 1675.00 14 20 1820.00 15 20 4394 5201 5995 2129.00 15 20 2445.00 16 20 2748.00 16 30 6755 7505 7880 3057.00 17 30 3366.00 18 30 3570.00 19 30 9006 10126 11258 4004.00 20 30 4333.00 21 30 4932.00 22 30 12002 13522 15010 5221.00 24 30 5840.00 26 30 6458.00 26 30 2751 3151 3537 3934 4346 4739 6069 6855 7640 8523 9312 10154 11361 12648 13841 15068 16720 18346 Standard equipment includes: V-531 diaphragm gas valve with manual opening feature; Baso automatic pilot switch for non-100% shut-off (100% shut-off controls consisting of Baso combination pilot switch and valve with auxiliary Baso pilot valves, optional at no additional charge) ; manual shut-off valve; pilot filter (manufactured gas and SUR); gas pressure regu lator; boiler drains and pilot cocks; insulated jacket; draft hood; transformer. For water boiler only; ASME relief valve for 50 lbs.; pressure and temperature gauge; CB-65653 immersion limit control. For steam boiler only; Steam gauge; ASME safety valve; CB-450552 boiler pressure limit control; gauge glass with trimmings; resetting low water cut-off. Ordiriag Exinplti: Notes: 1. Water boiler with standard equipment: 1 G-608-W boiler Nat. gas, 1000 Btu, .6 sg. 2. Steam boiler with optioqal equipment: 1 G-6011-S boiler with push button electric ignition Nat. gas, 1000 Btu. .6 sg. For ordering instructions, see page 2. For optional equipment, see page 14. For electronic control panel systems, see page 15. For complete information on boiler ratings, see page 2. For discount on repairs, see page 2. HH-4 Page 12 This Price List has been prepared for the convenience of American-Standard distributors and their trade cus tomers only. The trade prices shown represent fixed markups over distributor prices to reflect reasonable sellin' ri.or,hn,,on ,vnense and do not purport to represent actual prices prevailing In any particular marke 01675 AMERiCAN'<$tandard HYDRONIC HEATING BOILERS--GAS FIRED SriAM AMO WArtt G-60 American-Standard GAS BOILERS WATER bollar number G-606-W G607-W G608-W G-609-W G-6010-W G-6011-W G-6013-W G-6015W G-6017W G-6019-W G-6021W G-6022-W G-6025-W G-6028-W G-6031-W G 6033-W G6037-W G-6041-W STEAM botlar numbar G606S G-607-S G-608-S G-609-S G-6010-S G 6011-S G-6013-S G-6015-S G-6017S G-6019-S G-6021-S G-6022S G-6025S G-6028-S G 603I S G6033-S G-6037-S G6041-S A.Q.A. Input Mbh 650 780 910 1040 1170 1300 1560 1820 2080 2340 2600 2730 3120 3510 3900 4160 4680 5200 A.OA. Input Mbh 650 780 910 1040 1170 1300 1560 1820 2080 2340 2600 2730 3120 3510 3900 4160 4680 5200 for LP and LP-Air Gas J acketed. Tested and equipped for SO lbs. water working pressure. Available for 80 lbs. working pressure on special order. Controls regularly furnished for 115 volt. 60 cycle current. Ratings shown are for installation at sea level and up to 2.000 feet. A.GJL output Mbh 520 624 728 832 936 1040 1248 1456 1664 1872 2080 2184 2496 2808 3120 3328 3744 4160 not IsBsR rating Mbh 390.1 468.1 546.1 624.2 702.2 780.2 936.2 1108.1 1282.0 1452.3 1614.9 1695.7 1937.9 2180.1 2422.4 2585.4 2903.7 3229.8 not rating tq. ft wator 2600 3120 3640 4160 4680 5200 6240 7385 8545 9680 10765 11305 12920 14535 16150 17235 19360 21530 Trad# Prlca with standard aquipmant Iota thormostat $ 961.00 1118.00 1283.00 1461.00 1638.00 1783.00 2092.00 240800 2711.00 3020.00 3329.00 3533.00 3967.00 4296.00 4895.00 5184.00 5803.00 6421.00 chimnay slza diam. In. ht ft a 12 13 13 14 15 15 16 16 17 18 19 20 21 22 24 . 26 26 20 20 20 20 20 20 20 20 30 30 30 30 30 30 30 30 30 30 approx. shipping wight 2741 3141 3527 3923 4335 4728 6049 6835 7620 8503 9292 10139 11334 12616 13809 15036 16690 18316 A.GJL output Mbh 520 624 728 832 936 1040 1248 1456 1664 1872 2080 2184 2496 2808 3120 3328 3744 4160 nat l=B=:R rating Mbh 390.1 468.1 546.1 624.2 702.2 780.2 936.2 1108.1 1282.0 1452.3 1614.9 1695.7 1937.9 2180.1 2422.4 2585.4 2903.7 3229.8 sq. ft 1625 1950 2276 2601 2926 3251 3901 4617 5342 6051 6729 7065 8075 9084 10093 10773 12099 13458 Trada Prica with standard aquipmant lass thannostat $ 998.00 1155.00 1320.00 1498.00 1675.00 1820.00 2129.00 2445.00 2748.00 3057.00 3366.00 3570.00 4004.00 4333.00 4932.00 5221.00 5840.00 6458.00 chimnay siza diam. in. ht ft. ii 20 12 20 13 20 13 20 14 20 15 20 15 20 16 20 16 30 17 30 18 30 19 30 20 30 21 30 22 30 24 30 26 30 26 30 approx. shipping waight 2751 3151 3537 3934 4346 4739 6069 6855 7640 8523 9312 10154 11361 12648 13841 15068 16720 18346 Standard equipment includes: V-531 diaphragm gas valve with manual opening; 100% shut-off (100% shut-off controls for LP-air and LP gases consists of Baso combination pilot switch and valve with auxiliary Baso pilot valves); manual shut-off valve; gas pressure regulator (except for LP-gas); drain valves; pilot cocks; insulated jacket; draft hood; transformer. For water boiler only; ASME relief valve for 50 lbs.; pressure and temperature gauge; CB-65653 immersion limit control. For steam boiler only: Steam gauge; ASME safety valve; CB-450552 boiler pressure limit control, gauge glass with trimmings; resetting low water cut-off. Ordering [samples: Notes: 1. Water boiler with optional equipment For ordering instructions, see page 2. 1 G-6013-W boiler with dual gas equipment Propane gas. For optional equipment, see page 14. For electronic control panel systems, see page 15. 2. Steam boiler with standard equipment: 1 G-6015-S boiler Butane gas For complete information on boiler ratings, see page 2. For discount on repairs, see page 2. Pago 13 This Price List has been prepared for the convenience of American-Standard distributors and their trade cus tomers only. The trade prices shown represent fixed markups over distributor prices to reflect reasonable selling and distribution expense and do not purport to represent actual prices prev - ----- ir market. HH-4 01676 BOILERS--GAS FIRED STIAM ANO WATI* AMERicAN-cStandard HYDRONIC HEATING G-60 OPTIONAL EQUIPMENT Push button electric ignition: all sires of G-60 are available with push button eiectrtc ignition for use with natural, manu factured and mixed gas non-100''- shut-o(T. and will be fur nished when specified on order at the following added charges: bolter nze G-606 thru G 6011 edded charge $11.85 G-6013 thru G-6021 23.70 G-6022 thru G-6031 35.55 G-6033 thru G-6041 47.40 Pilot filters for G-60 for natural and mixed gases available at no additional charge when specified on order to meet local utility codes Room thermostats available atTrade Prices shown on page 30. McDonnell-Miller Low Water Cut-off No. 67 external type can be substituted for the regular No. 69 Low Water Cut-off on G-60 steam gas boilers at no additional charge. If desired, specify on order. "IS" Equipment: G-60 gas boilers can be furnished for use with Indirect Steam Hot Water Supply Systems. CB-65653 im mersion operating control for use in storage tank is required and will be furnished when specified on order at extra Trade Price as shown on page 30 This control operates gas valves on boiler electrically as required. Shipping weights of gas boilers for hot water supply are same as shown for regular gas boilers. Try-cock tappings and valve: if desired for steam boiler to meet local code specify on order and add $4 00 to Trade Price of steam boiler G-60 available tested for 80 lbs. water working pressure when specified on order. Add $3 00 per section to Trade Price of water boiler. McDonnell-Miller No. 47-2 and 51-2 Low Water Cut-off and Feeder combinations are available with G-60 steam gas boil ers in place of regularly furnished No. 69 low water cut-off. when specified on order, at the following added charges to Trade Price of steam boilers with regular equipment: bolter number G-606 thru G-6011 combination number 47-2 added chargee $38.00 G-6013 thru G-6041 51-2 54.00 McDonnell-Miller No. 247-2 and 51-2 low water Cut-off and Feeder combinations for water boilers are available with G-60 water gas boilers when specified on order. Add to the Trade Price of the water boiler with regular equipment the current Trade Price for these items shown in the current McDonnellMiller price sheet. F.M. and F.I.A. equipment: requires EG-0 or EPG-0 electronic control system and special gas control equipment. Price on application. V-532 Diaphragm gas valve without manual opening may be substituted for V-531 Gas valve with manual opening at no additional charge If desired specify on order. Side Outlet Steam ASME Safety Valves may be substituted at no additional charge if specified on order to meet local code requirements. G-60 external water heater tappings: maximum size all sec tions 1 Va". Add to Trade Price of boiler $2.00 per section tap ping and $2.00 per jacket punching. G-60 Right end steam trim tappings for pressure gauge and water column gauge glass furnished when specified on order at Trade Price additional charge of $10.00 per boiler. G-60 DUAL GAS BOILERS Natural and Propane Gases G-60 steam or water boilers are available with dual gas equipment using natural and propane gases. Specify on order and add the charge shown below to boiler with standard equipment. Selection of the boiler should be based on the A.G.A. and I=B=R ratings shown on page 12. boiler number G 606 G 607 G-608 G-609 G-6010 G-6011 G-6013 G-6015 G-6017 add to boiler Trade Price $ 95.00 100.00 105.00 110.00 115.00 120.00 145.00 165.00 185.00 boiler number G-6019 G-6021 G-6022 G-6025 G-6028 G-6031 G-6033 G-6037 G-6041 add to boiler Trade Price $205.00 225.00 240.00 270.00 300.00 350.00 375.00 445.00 480.00 Dual gas equipment: In addition to boiler with standard trim, dual gas boilers include: Two V-532 diaphragm gas valves; two manifolds; gas pres sure regulator (natural gas only); manual shut-off valves; ribbon burners; 100% safety shut-off (consists of Baso com bination pilot switch and valve with auxiliary Baso pilot valves); pilot cock; outdoor change-over control. This Price List has been prepared for the convenience of American-Standard distributors and their trade cus tomers only The trade prices shown represent fixed markups over distributor prices to reflect reasonable selling and distribution expense and do not purport to represent actual prices prevailing in a 01677 AMERicAN-<Standard HYDRONIC HEATING BOILERS-GAS FIRED STIAM ANO WATIR G-40 AND G-60 ELECTRONIC CONTROL PANEL SYSTEMS Panel System EPG-0: Provides electronic supervision of each primary pilot in each combustion chamber (1 to 4) and inter mittent C.CC.riC ir.lktcn v_vniylele duluuiatii uy- eration of boiler. 100% safety shut-off Equipment includes one main control panel with 1 to 3 auxiliary panels pre-wired jnd factory assembled. Q179A flame rod and electric ignition pilots, ignition transformer: V495B pilot solenoid valves. RA09OE electronic relay for each panel with 2-4 seconds re sponse timing and alarm contacts, minimum of 3 ft of flame rod wire and 3 ft of ignition cable per pilot, as required See additional charges below Panel System EPG-1: Provides manual ignition. non-lOO'c shut-off Available for Natural. Manufactured and Mixed Gas only Electronic supervision of a primary pilot and thermo couple supervision of all auxiliary pilots. Main burner gas supply only turned off on pilot failure. Continuous flame pilot operation Equipment includes- one mam control panel and for certain boiler sizes one auxiliary panel factory wired and assembled to main panel; Q179B flame rod primary pilot(s) ; Baso auxiliary pilot burners, Baso 850-1 switches with ther mocouples. RA890E electronic relay for each panel with 2-4 seconds response timing and alarm contacts; minimum of 3 ft of flame rod wire per pilot, as required See additional charges below. Panel System EPG-2: Provides manual ignition. 100% shut off Available for all gases Electronic supervision of a pri mary pilot and thermocouple supervision of all auxiliary pilots Mam burner and pilot burner gas supply turned off on includes one main control panel and for certain boiler sizes one auxiliary panel factory wired and assembled to mam panel. Q179B flame rod primary pilot(s> with special adapter for thermocouple. Baso auxiliary pilot burners. Baso 817-F-l 1 pilot valves with thermocouples. RA890E electronic relay for each panel with 2-4 seconds response timing and alarm con tacts: minimum of 3 ft of flame rod wire per pilot, as required See additional charges below Panel System EPG-3: Provides intermittent electric ignition on a primary pilot and continuous flame auxiliary pilots with 100shut-off Available for all gases Electronic supervision of a primary pilot and thermocouple supervision of auxiliary pilots Main burner and pilot burner gas supply shut-off on pilot failure Equipment includes: one mam control panel and for certain boiler sizes one auxiliary panel factory wired and assembled to main panel; Q179A flame rod and electric lenition primary pilotcsi; primary pilot solenoid valveis* V495B; Baso auxiliary pilot burner; Baso 817-F-ll pilot valves with thermocouples; 6000 volt secondary ignition trans formers). RA890E electronic relay for each panel with 2-4 seconds response timing and alarm contacts, minimum of 3 ft. of flame rod wire and 3 ft. of ignition cable per pilot, as re quired. See additional charges below. ADDITIONAL CHARGES--Trade Price Specify on order type of system desired as described above, and add charge listed for boiler size involved to Trade Price of G-40 or G-60 boiler with regular equipment. Ordering Example: 1 G-404-S boiler with EPG-0 Svstem nat. gas. 1000 Btu ,6sg. Panel System EPG-0 boiler number added charge Panel System EPG-1 boiler number added charge Panel System EPG-2 boiler number added charge G- 403 thru 407 G- 408 thru 4010 G- 606 thru 6011 G-6013 thru 6021 G-6022 thru 6031 G 6033 thru 6041 $166.00 182.00 182.00 369.00 553.00 738.00 G- 403 thru 4010 $151.00 G- 606 thru 6037 151.00 G-6041 282.00 Mfd. gas only: G-6028 thru 6037 $283.00 G- 403 thru 4010 $172 00 G- 606 thru 6037 172.00 G-6041 284.00 Mfd. gas only: G-6028 thru 6037 $285.00 Panel System EPG I available for Natu.n m wuiljctu-eo and Mned gases only Balance for all gases Panel System EPG-3 boiler number added charge G- 403 thru 4010 $188.00 G- 606 thru 6037 188.00 G-6041 337.00 Mfd. gas only: G-6028 thru 6037 $340.00 G-40 AND G-60 ELECTRONIC CONTROL SYSTEMS (less Panels) The following systems (EG-0. EG-!. EC-2 and EG-3) are also available. but do not include factory wired and assembled control panel. These systems provide the same function and are equipped with thesame basicparts (less panel) as described for EPG-0, EPG-1.EPG-2, andEPG-3. System EG-0: (Same function as EPG-0 less panel.) See additional charges below. System EG-1: (Same function as EPG-l less panel.) See additional charges below. System EG-2: (Same function as EPG-2 less panel.) See additional charges below. System EG-3: (Same function as EPG-3 less panel.) See additional charges below. ADDITIONAL CHARGES-Trode Price______________________ Specify on order type of system desued. as described above, and add charge listed for boiler size involved to Trade Price of G-40 or G-60 boiler with regular equipment. ___________________________________ Ordering Example: 1 G-6015-W boiler with EG-1 Svstem mfd. gas. 550 Btu .65sg. Control System EG-0 boiler number added charge a Control System EG-1 boiler number added charge a Control System EG-2 boiler number added charge G 403 thru 407 G- 408 thru 4010 G- 606 thru 6011 G 6013 thru 6021 G-6022 thru 6031 G-6033 thru 6041 $111.00 145.00 145.00 290.00 435.00 580.00 G- 403 thru 4010 $ 87.00 G- 606 thru 6037 87.00 G 6041 174.00 Mfd. gas on y: G-6028 thru 6037 $175.00 G- 403 thru 4010 $ 97.00 G- 606 thru 6037 97.00 G 6041 176.00 Mfd. gas on ly: G-6028 thru 6037 $177.00 a Control System EG-3 boiler number added charge G- 403 thru 4010 $116.00 G- 606 thru 6037 116 00 G-6041 230.00 Mfd. gas on ly: G 6028 thru 6037 $233.00 Control System EG-1 available for Natural. Manufactured and Mixed gases only Balance for all gases. ignition Cable: Trade Price per foot. . Flame rod wire: Trade Price per foot . ............................... $0.70 ................................................................... $0.30 Page 15 This Price List has been prepared for the convenience of American-Standard distributors and their trade cus tomers only The trade pi tees Miown represent fixed m irkups over distributor prices to reflect reasonable selling jnd distribution expense .md do not purport to represent actual prices prevailing in any particular market MH-4 01678 PACKAGED BOILER-BURNER UNITS WATH AMERiCAN-<$tandard HYDRONIC HEATING APR PACKAGED BOILER-BURNER UNITS Designed and equipped with controls for forced circulation. Factory assembled with jacket and crated. Built-in air-separator in top section. Motors and controls regularly furnished for 115 volt. 60 cycle current. WATER packaged unit number grots IbBsR output Mbit IsBbR burner capacity gph nat l = B=R rating Mbh net rating iq ft water Trade Price with itandard equipment APR-72 APR-90 72 0.70 54.0 360 90 0.90 67.5 450 $300.00 325.00 Nozzle sizes 60* solid, gph, furnished with APR packaged units: APR-72, 0.75: APR-90. 0.95. chimney site 8x8* 15 8 x 8 x 15 approi. shipping weight 306 344 Standard equipment all Units: Model DH-5 Arcoflame oil burner with sling mounting and factory installed light sensing flame detector. Constant ignition light sensing primary control. Unitized ceramic fiber refractory combustion chamber. Draft regulator. ASMS relief valve. 1" circulator. Wiring harness and junction box. Drain valve. Pressure and temperature gauge. CB-S8000 thermostat. AY-553 and AY-688 limit controls with Hi-Lo selector switch. Two-stage fuel unit available at $5.00 Trade Price extra. Note: APR units are shipped with jacket and electrical controls (except thermostat), com bustion chamber, circulator, factory assembled and wired. Arcoflame oil burner shipped separately. Draft regulator, relief valve and thermostat .are secured inside boiler box. Zone valve packages are available for APR units. For details and prices, see page 30. Ordering Eiampls: Packsged unit with standard equipment: 1 APR-90 Hotel: For complete information on boiler ratings, see page 2. For discount on repairs, see page 2. Page 16 This Price List has been prepared for the convenience of American-Standard distributors and their trade U?.n,'"' The trade prices shown represent fixed markups over distributor prices to reflect reasonable se hr. nnl n.i.nr.l Ir. r.nrM.nt art.nl nr.C-- nr-V-llmC in anv particular mi 01679 AMERiCAN-<Standard HYDRONIC HEATING PACKAGED BOILER-BURNER UNITS watu APH PACKAGED BOILER-BURNER UNITS Designed and equipped with controls for forced circulation. Factory assembled and crated. Square jacket. Built-in air-separator in top section. Motors and controls regularly furnished for 115 volt. 60 cycle current. WATER packaged unit number iron l=B=R output Mbh IsBsR burner cepecity *ph net t=B=R rating Mbh net reting ftp ft water Trade Price with standard equipment chimney ize APH-115 115 1.15 86 575 $350.00 APH-150 150 1.45 113 750 410.00 APH-185 185 1.80 139 925 470.00 8x8x 15 8x8x 15 8x8x 15 'Nozzle sizes, gph. 60* solid, furnished with APH packaged units: APH-115, 1.10; APH-150. 1.35; APH-185, 1.75 approx. shipping weight 330 375 420 Standard equipment all Units: Model DH-5 Arcoflame oil burner with sling mounting and factory installed light sensing flame detector. Constant ignition light sensing primary control. Unitized ceramic fiber refractory combustion chamber. Draft regulator. ASME relief valve. 1 Vi' circulator. Wiring harness and junction box. Pressure and temperature gauge. Drain valve. CB-52502 thermostat. AY-553 and AY-686 limit controls with HI-LO limit selector switch. Two-stage fuel unit is available at 55 00 Trade Price extra. Note: APH units are shipped with jacket and electrical controls (except thermostat), com bustion chamber, circulator, factory assembled and wired. Oil burner shipped separately. Draft regulator, relief valve and thermostat are secured inside boiler crate. Zone valve packages are available tor APH units. For details and prices, see page 30. Ordering Example: Packaged unit with standard equipment: 1APH-115 Notes: For complete information on boiler ratings, see page 2. For discount on repairs, see page 2. Page 17 This Price List has been prepared for the convenience ot American-Standard distributors and their trade cus tomers only. The trade prices shown represent fixed markups over distributor prices to reflect reasonable selling and distribution expense and do not purport to represent actual prices prevailing in any particular market. KH-* 01680 PACKAGED BOILER-BURNER UNITS Willi American-^Standard HYDRONIC HEATING A-3 PACKAGED BOILER-BURNER UNITS uesigneu ano equippea wun comrois lor torceu Factory assembled with flush jacket and crated. Wet base construction `Eliminaire" (cast-m air separator in front section). Motors and controls regularly furnished for 115 volt, 60 cycle current. WATER packaged unit number gross l=B=R output Mbh l=B=R burner capacity gph tankless heater number l=W=H rating net IsBsR rating Mbh net rating sq ft water Trad* Price with standard equipment chimney size approx. shipping weight Packaged units with factory installed tankless heater With R8182A Aquastat-relay combination, high limit. low limit and circulator control, light sensing constant ignition primary control. A-33PT A-34-PT A 35-PT 100 0.95 136 1.35 173 1.70 222 4 230 4 328 A3/. 75.0 1C2.0 129.8 500 680 865 $477.00 548.00 625.00 8x8x 15 8x8x15 8 x 8 x 15 735 818 956 Packaged units less heater: With R8182C Aquastat combination. limit and circulator control, light sensing constant ignition primary control. one heater opening cover plate. A-33P A-34-P A-35P 100 0.95 136 1.35 173 1.70 75.0 102.0 129.8 500 680 865 $449.00 518.00 590.00 8 x 8 x 15 8 x 8 x 15 8 x 8 x 15 720 801 944 'Nozzle sizes, gph, 60* furnished with A-3 packaged units: A-33-P. 0 90 --H: A-34-P. 1 25--H: A-35-P, 1.50--S. A Gallons of water per minute heated from 40F to 140F with 200F boiler water temperature. Standard equipment: Model DH-5 Arcoflame oil burner with sling mounting and factory installed cad cell, bracket and leads. CB-52502 thermo stat. Nozzle. Draft regulator. High temper ature steel combustion chamber. Pressure and temperature gauge. ASME relief valve. IV4" circulator with piping. Wiring harness. Dram valve. Notlf: For optional equipment, see page 21. For complete information on boiler ratings, see page 2. For discount on repairs, see page 2. Not*: Units are shipped with flush jacket and with all electrical controls (except thermo stat) . circulator and piping, factory installed and wired. Arcoflame oil burner shipped separately Draft regulator, relief valve and thermostat are secured inside boiler crate. Ordering Examples: 1. Packaged unit with heater with optional equip ment: l A-33-PT boiler-burner unit with jacket extension 2. Packaged unit less heater with standard equip ment. 1 A-34-P boiler-burner unit HH-4 Pag* 18 This Price List has been prepared for the convenience of American-Standard distributors and their trade cus tomers only. The trade prices shown represent fixed markups over distributor prices to reflect reasonable selling and distribution expense and do not purport to represent actual prices prevailing in any particular market. 01681 i^^nj AMERiCAN-<Standard HYDRONIC HEATING BOILER-BURNER UNITS STMM ANO WATK A-3 PACKAGED ALL-PURPOSE BOILER-BURNER UNITS Equipped with controls (or water (forced or gravity circulation) or steam. Factory assembled sections V-rct Flush jacket. Motors and controls regularly furnished for 115 volt. 60 cycle current. WATER boilerburner unit number gross l=BsR output Mbh !=B=R burner capacity gph tankless heater number A t=W=H rating net l=B=R rating Mbh net rating sq ft water Trade Price with standard equipment ch>imlzn.ey j `IhPip0p'?in1g' weight Forced circu ation units with factory inst ailed tankless heater With R8 182A Aquastat-relay combination, high limit, low lim t and circulator control, light sensing c onstant ignition cont rol. A-33WBT 100 0.95 222 4 A-34WBT 136 1.35 230 4 A-35WBT 173 1.70 328 4Ve A-36WBT 208 2.00 335 5`/z A-37WBT 244 2.30 335 5Ve 75.0 102.0 129.8 156.0 183.0 500 680 865 1040 1220 $378.50 448.50 530.50 600.50 676.50 8 x 8 x 15 8 x 8 x 15 8 x 8 x 15 8x8x 15 8 x 12 x 15 666 751 878 1016 1148 Forced circulation units less heater: With R8182C Aquastat combination, limit and circulator control, light sensing constant ignition primary control. A-33-W8 A-34-WB A-35-WB A-36-WB A-37-WB 100 0.95 136 1.35 173 1.70 208 2.00 244 2.30 75.0 102.0 129.8 156.0 183.0 500 680 865 1040 1220 $351.50 420.50 497.50 561.50 637.50 8x8x15 8 x 8 x 15 8x8x15 8 x 8 x 15 8 x 12 x15 655 737 872 1002 1135 Gravity units less heater With 14080 Aquastat limit control, and separate R8184A light sensing constant ignition primary control. A-33-WBG 100 0.95 A-34WBG 136 1.35 A-35WBG 173 1.70 A-36-WBG 208 2.00 A37WBG 244 2.30 75.0 102.0 129.8 156.0 183.0 500 680 865 1040 1220 $347.00 416.00 493.00 557.00 633.00 8 x 8 x 15 8 x 8 x 15 8 x 8 x 15 8 x 8 x 15 8 x 12 x 15 660 742 877 1006 1138 STEAM boiler* burner unit number grots l:BsR output Mbh l=8=R burner capacity gph tankless heater number l=W=H rating net l=B=R rating Mbh net t=B=R q ft steam Trade Pne# with standard equipment chimney sire approx. shipping weight Steam units with factory installed tankless heater: With PA404A Pressuretrol. L4006A Aquastat operating control, and separate R8184A light sensing constant ignition primary control. A-33SBT A 34-SBT A 35 SBT A-36-SBT A-37SBT 100 0.95 222 3Vz 136 1.35 230 3`/2 173 1.70 328 4 Vi 208 2.00 335 4 V. 244 2.30 335 5 Vi 75.0 102.0 129.8 156.0 183.0 313 $375.00 8 X 8x15 666 425 446.00 8 X 8x15 751 541 528.00 8 X 8 x 15 878 650 598.00 8 X 8 x 15 1016 763 674.00 8 X 12 x 15 1148 Steam units less heater With PA404A Pressuretrol, and separate R8184A light sensing constant ignition primary control. A-33-SB A-34-SB A35SB A-36-SB A-37-SB 100 0.95 136 1.35 173 1.70 208 2.00 244 2.30 75.0 102.0 129.8 156.0 183.0 313 $347.00 8x8x 15 661 425 416.00 8 x 8 x 15 743 541 493.00 8 x 8 x 15 878 650 557.00 8x8x 15 1007 763 633.00 8 x 12 x 15 1139 -Nozzle nut, gph, 60" furnished with A-3 bonerburner units: A-33-B, 0.90-H: A-34-B. 1.2S-H: A-35-B. 1.50-S: A-36-B. 1.75-S 2.25-S. ^Gallons of water par minute heated from 40F to 140F with 200F boiler water temperature. Standard equipment: Model DH-5 Arcoflame oil burner with sling mounting and factory installed cad cell, bracket and leads. CB-52502 thermo stat. Nozzle. Draft regulator. High tem perature steel combustion chamber. Drain valve. For units WITH water heater, 1 cover plate with control tapping. For units LESS water heater. 2 cover plates for heater openings. Water Pressure and temperature gauge. ASME relief valve. Steam: Steam gauge. ASME safety valve. Gauge glass and trimmings. Ordering Examples: 1 All-Purpose boiler-burner unit with standard eouio- ment: For forced circulation, with heater1 A-37-W8T boiler-burner unit For gravity circulation: 1 A-33-W0G boiler-burner unit 2 All-Purpose boiler-burner unit with optional equip ment: For forced circulation, less heater: 1 A-35-W8 boiler-burner unit with two-stage Notes: fuel unit. For optional equipment, see page 21. For complete information on boiler ratings, see page 2. For discount on repairs, see page 2. Pago 19 Thu Price List has been prepared for the convenience of American-Standard distributors and their trade cus tomers only. The trade prices shown represent fixed markups over distributor prices to reflect reasonable selling and distribution expense and do not purport to represent actual prices prevailing in any particular market. HH-4 01682 OIL FIRED BOILERS ST1AM AND WATIR American-tStandard HYDRONIC HEATING A-3 ALL-PURPOSE OIL FIRED BOILERS For water (forced or gravity circulation) or steam. Factory assembled sections. Wet base construction. Flush jacket. rV--.A WATER boiler number croes l=B=R outout Mbh l=B=R burner capadty gph tankless heater number A IsWsH rating net IsBsR rating Mbh Boiler with factory insta led tankles* heater--forced circulation net rating SR ft water Trade Price chimney til* approx. shipping weight A33-WT A-34-WT A-35-WT A-36-WT A-37-WT 100 0.95 222 4 136 1.35 230 4 173 1.70 328 4 Vs 208 2.00 335 5`/2 244 2.30 335 5 Vs Boiler less heater--gravity or forced circulation 75.0 102.0 129.8 156.0 183.0 500 680 865 1040 1220 $250.00 321.00 403.00 473.00 549.00 8a 8x 15 8x8x 15 8 x 8 x 15 8x8x 15 8 x 12 x15 613 698 825 962 1093 A-33-W A-34-W A-35-W A-36-W A-37W 100 0.95 136 1.35 173 1.70 208 2.00 244 2.30 75.0 102.0 129.8 156.0 183.0 500 680 865 1040 1220 $232.00 301.00 378.00 442.00 518.00 8x8x 15 8x8x 15 8 x 8 x 15 8x8x 15 8 x 12 x 15 605 687 822 951 1083 STEAM boiler number gross IsBsR output Mbh IsBsR burner capadty gph tankless heater number A l=W=H rating Boiler with factory installed tankless heater nat l=B=R rating Mbh net l=B=R SQ ft steam Trade Price chimney size A-33-ST A-34-ST A-35ST A-36-ST A-37-ST 100 0.95 222 3`/2 75.0 136 1.35 230 3 Vi 102.0 173 1.70 328 4 Vi 129.8 208 2.00 335 4 Vi 156.0 244 2.30 335 5Vi 183.0 313 $250.00 8 x 8 x 15 425 321.00 8x8x 15 541 403.00 8x8x 15 650 473.00 8x 8 x 15 763 549.00 8x 12 x 15 Boiler less heater A-33-S A-34-S A-35-S A-36-S A-37-S 100 0.95 136 1.35 173 1.70 208 2.00 244 2.30 75.0 102.0 129.8 156.0 183.0 313 425 541 650 763 $232.00 301.00 378.00 442.00 518.00 8x8x 15 8x8: 15 8x8x 15 8x8x 15 8x12x15 aGallona of water par minute heated from 40F to 140F with 2OOF boiler water temperature. approxshipping weight 614 699 826 963 1094 606 688 823 952 1084 HH-4 Standard equipment all boilers: High temperature steel combustion cham ber. Drain valve. Water: Pressure and temperature gauge, ASME relief valve. Steam: Steam gauge. ASME safety valve, gauge glass and trimmings. Note: Boilers with factory installed tankless heater are shipped with one water heater opening cover plate with \" control tap ping. Boilers less factory installed heater are shipped with an additional water heater opening cover plate (blank). Ordtring Exaaplss: 1. Water boiler less heater with standard equipment: 1 A-34-W boiler 2. Steam boiler with heater with standard equipment: 1 A-36-ST boiler 3. Water boiler with heater with optional equipment: 1 A-35-WT boiler with jacket extension Notes: For optional equipment, see page 21. For complete information on boiler ratings, see page 2. For discount on repairs, see page 2. Page 20 This Price List has been prepared for the convenience of American-Standard distributors and their trade cus tomers only. The trade prices shown represent fixed markups over distributor prices to reflect reasonable selling and distribution expense and do not purport to represent actual prices prevailing in any partlcul 01683 AMERiCAN-<Standard hydronic heating BOILER-BURNER UNITS OIL FIRED BOILERS STCAM AND WATtK A-3 OPTIONAL EQUIPMENT FOR PACKAGED AND ALL-PURPOSE BOILER-BURNER UNITS AND OIL FIRED BOILERS: Jacket extension: Specify on order and add $28 00 to Trade Price of boiler or unit Jacket extension provides 15^iT in front for concealment of oil burner and controls; approximate shipping weight 35 lbs. FOR PACKAGED AND ALL-PURPOSE BOILER-BURNER UNITS: Two-stage fuel unit will be furnished on order at $5 00 Trade Price extra. For substitution of No. 4 control set consisting of CB-52502 thermostat, L4062B Aquastat limit and circulator control, plus a No. R3184A light sensing constant ignition primary control, instead of R8182C combination control, add to price of nonpackaged A-3 boiler-burner units for forced circulation LESS heater $2.50 Trade Price extra. For substitution of No. 5 control set consisting of CB-52502 thermostat. L8024A Aquastat, limit, reverse and operating control, circulator relay, plus a No. R8184A light sensing constant ignition primary control, instead of R8182A com bination control, add to price of non-packaged A-3 boilerburner units for forced circulation WITH tankless heater $2.50 Trade Price extra. Order add-on No. 5-Z control set at $19 35 Trade Price extra for use with A-3 packaged or all-purpose non-packaged boiler-burner units with tankless heater. Order R8182A Aquastat-relay combination at $10.00 Trade Price extra instead of R8182C control to permit use of tankless heater with A-3 non-packaged boiler-burner units furnished less water heater Controls and Arcoflame control sets are shown on page 30. McDonnell-Miller No 67 low water cut-off with quick hook up fittings is available at current price for A-3 steam units and boilers. Zone valve packages are available for water units and boilers For details and prices, see page 30. BUILT-IN TANKLESS HEATERS: Built-in tankless heaters can be ordered for separate shipment with packaged and all-purpose boiler-burner units and oil fired boilers less factory installed heaters at the follow mg Trade Prices: Heater number 222 230 328 335 Trade Prica $21.00 23.00 28.00 34.00 NOTE: For l-W-H ratings and bol be used, see table below. or units with which heaters can l=W=H RATED TANKLESS WATER HEATERS FOR A-3; Heaters tested with boilers. Built-in tankless heaters for boiler-burner units and oil boilers can be ordered for separate shipment with units or boilers specified less tankless heaters at Trade Prices shown above. Select heater from table below. unit pr boiler size A-33 A-34 A-35 A-36 A-37 IsBsIt bumpr capacity fph 0.95 1.35 1.70 2.00 2.30 heater number 222 230 328 335 335 A !=W=sH rating water steam 4 3Vi 4 3Vz 4% 4 Vi 5>/2 4 Vi 5V 5 Vi A Gallons of water per minute heated from 40F to 140F with 200F boiler water temperature. Page 21 This Pnce List has been prepared for the convenience of American-Standard distributors and their trade cus tomers only. The trade prices shown represent fixed markups over distributor prices to reflect reasonable selling and distribution expense and do not purport to represent actual prices prevai,,-" " 01684 BOILER-BURNER' UNITS OIL FIRED BOILERS ITUM AMO WATIX 'American andard HYDROKIC ,H EATING SEVERN BOILLR-6URNER UNITS Flush jacket. Motors and controls regularly furnished for 115 volt. 60 cycle current. boiler-burner unit number STEAM WATER gTOBB output Mbh fifing rato ___ e*____ Installed radiation tq ft steem Mbh NOT TAPPED FOR BUILT-IN TANK TYPE WATER HEATER (see options) S-170B S-21-0B S-25-OB S-29-OB S-33-0B S-37-OB W-17-OB 146 1.5 456 109.5 W-21-OB 168 1.7 525 126.0 W-25-OB 188 1.9 588 141.0 W-29-0B 216 2.2 675 162.0 W-33-OB 247 2.5 772 185.3 W-37-OB 278 2.8 869 208.6 sq ft water 730 840 940 1080 1235 1390 Trado Piiea arfth standard equipment $489.00 531.00 572.00 615.00 680.00 738.00 approx. hipping weight 1283 1438 1550 1690 1795 1955 ARRANGED FOR BUT LESS BUILT-IN TANK OR TANKLESS TYPE WATER HEATER S-17-OB-T W-17-OB-T 146 1.5 456 109.5 730 $495.00 1292 S-21-OB-T W-21-OB-T 168 1.7 525 126.0 840 537.00 1447 S-25-OB-T W-25-OB-T 188 1.9 588 141.0 940 578.00 1559 S-29-OB-T W-29-OB-T 216 2.2 675 162.0 1080 621.00 1699 S-33-OB-T W-33-OB-T 247 2.5 772 185.3 1235 686.00 1804 S-37-OB-T W-37-OB-T 278 2.8 869 208.6 1390 744.00 1964 'Nozzle sizes, gph 60* Solid, furnished with Severn boiler-burner units: No. 17. i .35; No. 21. 1.50; No. 25. 1.75; No. 29. 2.00; No. 33. 2.25; No. 37. 2.S0. Standard equipment: Model DH-6 Arcoflame oil burner with factory installed light sensing flame detector with sling mounting. Constant ignition light sensing primary control. Draft regulator. Heat Lib-O-Rator refractory combustion chamber; model number and deduction for omis sion listed on page 23. For steam-No. 1 control set: CB-52502 thermostat. PA404A Pressuretrol, nozzle. Steam gauge. ASME safety valve. Gauge glass and trimmings. For water--No 3 control set: CB-52502 thermostat. L4080 Aquastat limit control, nozzle. Pressure and temperature gauge. ASME relief valve. SEVERN OIL FIRED BOILERS Flush jacket. boiler-number STEAM WATER groaa output Mbh firing rata gph Installed radiation sq ft Btaam Mbh NOT TAPPED FOR BUILT-IN TANK TYPE WATER HEATER (see options) q ft watar S-17-0 S-21-0 S-25-0 S-29-0 S-33-0 S-37-0 W-17-0 W-21-0 W-25-0 W-29-0 W-33-0 W-37-0 146 1.5 456 109.5 730 168 1.7 525 126.0 840 188 1.9 588 141.0 940 216 2.2 675 162.0 1080 247 2.5 772 185.3 1235 278 2.8 869 208.6 1390 ARRANGED FOR BUT LESS BUILT-IN TANK OR TANKLESS TYPE WATER HEATER S-17-0-T S-21-0-T S-25-0-T S-29-0-T S-33-0-T S-37-0-T W-17-0-T 146 1.5 456 109.5 730 W-21-O-T 168 1.7 525 126.0 840 W-25-O-T 188 1.9 588 141.0 940 W-29-O-T 216 2.2 675 162.0 1080 W-33-0-T 247 2.5 772 185.3 1235 W-37-0-T 278 2.8 869 208.6 1390 Trade Prict with standard quipmant $355.00 397.00 436.00 479.00 542.00 600.00 $361.00 403.00 442.00 485.00 548.00 606.00 approx. shipping weight 1075 1230 1325 1465 1560 1720 1084 1239 1334 1474 1569 1729 Standard equipment: For Steam only: Steam gauge. ASME safety valve. Gauge glass and trimmings. For Water only: Pressure and temperature gauge. ASME re lief valve. Notts: For optional equipment, see page 23. For complete information on boiler ratings, see page 2. For discount on repairs, see page 2. Ordering Euaplat: 1. Boiler-Burner Unit for steam not tapped for heater with standard equipment: 1 S-25-OB boiler-burner 2. Boiler-Burner Unit for water arranged for but less heater with optional equipment: 1 W-33-08-T boiler-burner with two-stage fuel unit. ,, 3. Boiler only for water arranged for but less heater with optional equip ment: 1 W-21-0-T boiler with heater opening cover plate HH-* Page 22 This Price List has been prepared for the convenience of Amen can-Standard distributor, and their trade cus tomers only. The trade price, shown represent fixed markups over distributor prices to reflect reasonable ae' and distribution expense and do not purport to represent actual prices prevailing in any particular mi, 01685 AMERiCAN-^Standard hydronic heating BOILER-BURNER UNITS OIL FIRED BOILERS lit** AND WATII SEVERN OPTIONAL EQUIPMENT BOILER-BURNER UNITS only: Arcoflame control sets other than those included in Trade Price ot boiler-bumer units will he furnished when specified on order at the following added charges: Control Set Added Charge Steam control set No. 2.............. ................. $10.00 Water control set No. 4.............. ................. 5.80 Water control set No. 6.............. ................. 24.30 Water control set No. 7.............. ................. 22.45 Controls and Arcoflame control sets are shown on page 30. Two-stage fuel unit is available for DH-6 oil burner at added Trade Price charge of............................................................... $5.00 BOILER-BURNER UNITS or OIL FIRED BOILERS: Zone valve packages are available for water boilers. For de tails and prices, see page 30. For low water cut-off for use with steam units, see page 30. Molded refractory combustion chambers for Severn boilers: Trade Prices are same as "Deduct for Omission" prices shown below. Cover plate for water heater opening will be furnished if specified on order for "T" type boiler at an added Trade Price charge of $3.70. BUILT-IN HEATERS: If 2V4' right or left side tapping in back section for built-in heater No. 703 is desired, specify on order and add $2.00 to Trade Price of unit or boiler. Below are the ratings and Trade Prices covering built-in tank or tankless heaters available for Severn units. For detailed information on ratings, see page 2. Heater No. 703 594 595 590 Heater Type HeaterRatings gals, capacity tank tank tank tankless 66 100 160 3 Vi per minute Trade Price $ 9.00 48.00 42.50 36.00 approi. shipping weight 7 54 51 60 HEAT LIB-O-RATOR MOLDED REFRACTORY COMBUSTION CHAMBERS unit number Heat Ub-O-Rator medal No. Included maximum firing rate gallons per hour deduct for omission approx. shipping weight 17. 21 25. 29 33. 37 No. 1 No. 2 No. 3 1.75 2.25 3.00 $18.85 20.85 22.85 153 170 180 For discount on repairs, see page 2. Peg* 23 This Price List has been prepared lor the convenience of American-Standard distributors and their trade cus tomers only. The trade prices shown represent fixed markups over distributor prices to reflect reasonable selling and distribution expense and do not purport to represent actual prices prevailing in >nv Dartlcular market. 01686 HH-4 BOILER-BURNER UNITS OIL FIRED BOILERS ITIAM AMO WATII AMERiCAK-cStandard HYDRONIC HEATING A-5 BOILER-BURNER UNITS Flush Jscket. Tested end equipped (or SO lbs. water working pressure. boiler-burner STEAM | WATER Motors and controls regularly furnished are for 115 volt. 60 cycle current. |TMI IsRsR output Mb* 4 IsBsft burner capacity 0* not l=B= R rating sqft toom Mbh not ratine Rft watar Trade Price wtth standard equipment chimney also For Built-In Water Heater Arrangement, see page 25. approx. shipping woieht A-504-SB(T) A-505-SBfT) A-506-SB(T) A-507-SBfD A-508-SB(T) A-509-SBC0 A-510-SB(T) A-511-SBCTj A-504-WB(T) A-509-WBfO A-506-WB(T) A 507-WB(T) A-508WB(T) A-509-WB(T) A-510-WB(T) A-511-W8CO 261 346 426 508 588 668 748 830 2.55 3.30 4.00 4.75 5.55 6.30 7.00 7.65 616 1082 1332 1588 1838 2088 2338 2594 195.8 259.6 319.6 381.1 441.1 501.1 561.1 622.7 1305 1731 2131 2541 2941 3341 3741 4151 $ 700.00 844.00 952.00 1068.00 1153.00 1248.00 1390.00 1528.00 8 x 12x15 8x12x20 12 x 12x20 12 x 12 x 20 12 x 16x25 12 x 16x25 12 x 16 x 25 16 x 16 x 30 'Nozzla tlzti, gph. furnished with A 5 units ars as follows: No. A-504, 1 2.SO 60'S: A-505, 2 1.65 70*S; A-506 2 2.00 70*S: A-507 1 2.25 A 1 2.50 M'H; A S08 2 2.75 SO'H; A-509. 1 3.00 A 1 1.25 M'H; A-510 2 3.50 80`S; A-511 1 3.50 A 1 4.00 SO'S. Suffix *T" denotes unit or botler with oponingt in center sections for tankless heaters. 1702 1971 2286 2565 2809 3109 3377 3684 Standard equipment; boiler model A-504 A-505, A-50B A-507. A-508, A-509 A-510 oil burner DH-5. sling mounted; 1-stage fuel unit. 45WU-3606 } S2A-7056-1 ) 96-7506-1 J flange mounted; 2-stage fuel unit. The above burners are furnished with factory installed light sensing flame detector, constant ignition light sensing primary controL 'A-511 96-7506 flange mounted; 2-stage fuel unit. The above burner is furnished with electronic flame safeguard control: RA890E Pro. tectorelay and Q270A base. C7013A photocell, delayed oil valve. Draft regulator. Drain valve. Heat Lib-O-Rator refractory combustion chamber; model number and deduction for omission listed on page 25. For Steam-No. 1 control set: CB-52502 thermostat, PA404A Pressuretrol, nozzle(s). Steam gauge. ASMS safety valve. Gauge glass and trimmings. For Water-No. 3 control set: CB-52502 thermostat, L4080 Aquastat limit control, noz zle (s). Pressure and temperature gauge. ASME relief valve. A-5 OIL FIRED BOILERS Flush Jacket. Tested and equipped for 50 lbs. water working pressure. boiler number STEAM WATER Croat l=B=R OjJtgUt l=B=R burner capacity 0b net l=BsR ratine aq ft steam Mbh net ratine ad ft water Trade Price chimney alia For Built-in Vlater Heater Arrangement, see page 25. A-504-SfT) A-505S(T) A-506-S(T) A-504-W(T) A-505-W(T) A-506WCO 261 2.55 816 195.8 1305 $ 560.00 346 3.30 1082 259.6 1731 660.00 426 4.00 1332 319.6 2131 760.00 8x 12 x 15 8 x 12 x 20 12 x 12 x 20 A-507-Sm A-508S(T) A-509-SOD A-507-W(T) A-508-W(T) A-509-W(T) 508 4.75 1588 381.1 2541 588 5.55 1838 441.1 2941 668 6.30 2088 501.1 3341 860.00 945.00 1030.00 12 x 12 x 20 12 x 16x25 12 x 16x25 A-510-Sm A-511-Sm A-510-W(T) A-51 lWCO 748 830 7.00 7.65 2338 2594 561.1 622.7 3741 4151 1115.00 1200.00 12 x 16 x 25 16 x 16 x 30 Suffix 'T" denotes unit or boiler with openings in center sections for tankless heaters. Standard equipment: For Steam only; Steam gauge, ASME safety valve, gauge glass and trimmings. Drain valve. For Water only: Pressure and temperature gauge. ASME relief valve for 50 lbs. Dram valve. Nstssi For optional equipment see page 25. For complete information on boiler ratings, see page 2. For discount on repairs, sea page 2. Ordering Examples: 1. Boiler-Sumer Unit for water with standard equipment: 1 A-S07-WB boiler-burner 2. Boiler-Burner Unit for steam with optional equipment 1 510-SBT boiler-burner with No. 2 control set 3 No. 530 Tankless Heaters 1 3-heater manifold assembly '] Boiler only for water with optional equipment l A-506-W boiler with jacket extension tfH-4 Pact 24 This Pnce List has been prepared tor the convenience of American-Standard distributors and their trade cus tomers only. The trade prices shown represent fixed markups over distributor prices to reflect reasonable selling and dlstnbuUon expense and do not purport to represent actual pncea prevailing In any particular ------ '* approx. ahipplne welcht 1489 1750 2050 2306 2550 2825 3075 3377 01687 American-Standard HYDRONIC HEATING A-S optional equipment BOILER-BURNER UNITS OIL TIRED BOILERS (TIAM AND WATII BOILER-BURNER UNITS ONLY: Arcoflame control sets other than those included in Trade Price of boiler-burner units will be furnished when specified on order at the following added charges: Control Sot added eharfo Steam control setNo. 2 $10.00 Water control setNo. 4............................ 5.80 Water control setNo. 5 14.55 Water control setNo. 5-Z . . . 19.35 (Add-on zone. Use only with No 5 control set.) Detailed description of control sets is shown on page 30 ELECTRONIC FLAME SAFEGUARD CONTROL EQUIPMENT: boiler-burner unit burner model added Trade Price charge A 507. A 508, A-509 62A-7056-1 F A-510 96-7506 $9000 53.00 With RA890E Protectorelay. Q270A base, C7013A photocell, delayed oil valve. For installations requiring Factory Mutual Approval and in states and municipalities with regulations more stringent than UL, oil burners are available with special electronic flame safeguard controls for A-5 boiler burner units as follows: boiler-bumer unit A-507, A-508. A-509 A-510 A-511 burner model 62A-7056-1-FFM 96-7507 96-7507 added Trade Price charge $120.00 87.00 34.00 Two-stage fuel unit is available for DH-S oil burner at added Trade Price charge of............................................................... $5.00 BOILER-BURNER UNITS or OIL FIRED BOILERS: Jacket extension; if desired specify on order and add $33.85 to Trade Price of boiler. Jacket extension provides 25" en closure m front for concealment of oil burner and controls. Approximate shipping weight 57 lbs. For low water cut-off for use with steam units, see page 30. Molded refractory combustion chambers for A-5 boilers: Trade Prices are same as "Deduct for Omission" Prices shown below. If desired, provision for tankless heaters is available at no additional charge. When suffix letter "T" is added on order to unit or boiler numbers, the following number of openings m center sections will be furnished. Unit No. Openings A 504-T 2 A-505 T thru A-508-T 3 A-509 T thru A-511-T 4 Note: Additional openings can be specified on order. Cover plate for water heater opening will be furnished if specified on order for "T" type boiler at added Trade Price of $3.35 each. NO. 530 TANKLESS HEATER: No. 530 tankless heater available in single or quantity lot price at $30.65 Trade Price each. The following table shows the recommended number of heat ers to be used with each boiler and the ratings attained if more than one heater is connected in parallel: boiler no. no. of heaters reting-gpm All Sizes All Sizes A-505--A-511 A-508--A-511 A-510--A-511 i 2 3 4 5 4 7 10 13 16 Note: Additions! heaters can be added if the heaters are serving differ ent systems and it is not likely that heaters will all be m use at the same time. 'Gallons of water per minute raised from 40 F to 140 F with 200 F boiler water temperature. Copper pipe manifolds factory assembled for multiple heater parallel hookup shipped in boxes of two manifold assemblies per box when specified with heaters are available at the fol lowing charges: Manifold assembly 2 heater 3 heater 4 heater Trade Price per Box $4.80 6.80 880 HEAT LIB-O-RATOR MOLDED REFRACTORY COMBUSTION CHAMBERS unit number A-504 A-505 A 506 A-507, A-508 A-509. A-510, A-511 Host UbO-ftator model No. Included 14-A 15-A 15-AA 16-A 17-A maximum firing rate gallons per hour 2.55 3.30 4.00 5.55 7.65 deduct for omission $24.85 25.00 33.00 33.00 38.00 approx. shipping weight 158 163 176 180 200 For discount on repairs, see page 2. This Price List has been prepared for the convenience of American-Standard distributors and their trade cus tomers only. The trade price* shown represent fixed markups over distributor prices to reflect reasonable selling and distribution expense and do not purport to represent actual prices prevailing in any particular market. 01688 BOILER-BURNER UNITS OIL FIRED BOILERS ITUM AND WAtlh American-^Standard HYDRO NIC HEATING A-7 BOILER-BURNER UNITS Jacketed and unjacketed. TcJ*Cm r.r.CQlaippCu aQT 55 iwS n'SeC* prpeenra Motor* and controls regularly furnished for 1 IS volt, 60 cycle current. boilar-humar unit numbr STEAM WATER (rots IsBaft output Mbit lc9R bumar cipaaty gph not 1=8 sR rating sq ft ttum Mbh nt rating M| ft watar chirrnay *lza unltcketed JackaUd Trad* Plica approx. Trada Prica approx. with itandarc hipping with standard hipping quipmant waight quipmant waight A-705-S0-B A-705-WO-B A-706-SO-B A-706-WO-B A-707SO-B A-707-WO-B A-708SO-B A-708-WO-B A-709SO-B A-709-WO-B A-710-SO-B A-710-WO-B A-711-SO-B A-711-W0-B A-712-SO-B A-712-WO-B A-713-SO-B A-713 WO-B A-714-SO-B A-714-WO-B 866 1012 1196 1376 1570 1760 1956 2148 2340 2532 8.15 9.55 11.25 12.90 14.65 16.30 18.00 19.65 21.45 23.20 2707 3163 3738 4340 5013 5672 6328 6949 7570 8191 649.7 759.2 897.2 1041.6 1203.1 1361.2 1518.6 1667.7 1816.8 1965.8 4331 5061 5981 6944 8020 9075 10125 11118 12112 13105 16 x 16 x 28 16 x 16 x 30 16 x 20 x 36 16 x 20 x 42 16 x 20 x 45 20 x 20 x 50 20 x 20 x 55 20 x 20 x 60 20 x 24 x 70 20 x 24 x 80 $1633.00 1753.00 1928.00 2277.00 2429.00 2607.00 2804.00 2974.00 3297.00 3469.00 4231 4883 5532 6283 6919 7603 8195 8871 9613 10341 $1714.00 1846.00 2033.00 2394.00 2558.00 2748.00 2957.00 3139.00 3474.00 3658.00 4403 5058 5715 6492 7134 7822 8456 9169 9883 10611 *Nozxla sizas, gph. S0*S. furnished with A-7 units ara at follows: A-70S, 2 4.00; A-706. 1 4.50, 1 5.00: A-707, 2 5.50; A-708 1 4.00, 2 4.SO; A-709. I 4.50. 2 S.00; A-710. 1 5.00. 2 S.50; A-7U. 3 6.00; A-712. 3 6.50; A-713. 2 5.00. 1 11.00; A-714. 2 5.50. 1 12.00. Standard equipment: boiler model oil burner A-705, A-706, A-707 A-708, A-709, A-710 A-711, A-712 A-713, A-714 96-7508 \ 97-7606 I pedestal mounted; 98-7706 f 2-sUge fuel unit 97A Hi-Lo 7668 J All the above burners include RA890E Protectorelay and Q270A base, C7013A photocell On 96-7508 burner, Q270A base is mounted on burner housing. On 97-7606, 98-7606, and 97A Hi-Lo 7668. W41SB1 panel is furnished with Q270A base and R488E load relay. Delayed oil valve with 96, 97 and 98 burners; 3 oil valves with model 97A Hi-Lo. Draft regulator. Drain valve. Steel pedestal base in addition to regular 12' base: 8' height for 5 through 7 section; 10~ height for 8 through 14 section. For Steam; PA404A Pressuretrol, nozzles. Steam gauge. ASME safety valve. Gauge glass and trimmings. For Water L4080 Aquastat limit control, nozzles. Pressure and temperature gauge. ASME relief valve for 50 lbs. Combustion chamber not furnished. See Installation-Operation and Maintenance Man ual for combustion chambers for A-7 boiler-burner units. A-7 OIL FIRED BOILERS Jacketed and unjacketed. Tested and equipped for SO lbs. water working pressure. boilar numbar STEAM WATER gross InB-R IsRsR bumor output capacity Mbh CPh nat 1=8 =R rating q ft staam Mbh nat rating sq ft wstar chimnay siza unjacfcatad lackatod approx. approx. Trada Prica shipping Trada Prica shipping waight waight A-705-SO A-706-SO A-707-S0 A-708-SO A-709-SO A-710-SO A-711-SO A-712-SO A-713-SO A-714-S0 A-705-WO A-706-WO A-707-WO A-708-WO A-709-WO A-710-WO A-711-W0 A-712-WO A-713-WO A-714-WO 866 1012 1196 1376 1570 1760 1956 2148 2340 2532 8.15 9.55 11.25 12.90 14.65 16.30 18.00 19.65 21.45 23.20 2707 3163 3738 4340 5013 5672 6328 6949 7570 8191 649.7 759.2 897.2 1041.6 1203.1 1361.2 1518.6 1667.7 1816.8 1965.8 4331 5061 5981 6944 8020 9075 10125 11118 12112 13105 16 x 16x28 16 x 16 x 30 16 x 20 x 36 16 x 20 x 42 16 x 20 x 45 20 x 20 x 50 20 x 20 x 55 20 x 20 x 60 20 x 24 x 70 20 x 24 x 80 $1260.00 1380.00 1555.00 1725.00 1877.00 2055.00 2227.00 2397.00 2567.00 2739.00 3882 4518 5149 5720 6330 6990 7556 8208 8912 9616 (1341.00 1473.00 1660.00 1842.00 2006.00 2196.00 2380.00 2562.00 2744.00 2928.00 4054 4693 5332 5929 6545 7209 7817 8506 9182 9886 Standard equipment: For Steam only: Steam gauge. ASME safety valve. Gauge glass and trimmings. For Water only: Pressure and temperature gauge. ASME relief valve for SO lbs. Krtss: For optional equipment, see page 27. For complete information on boiler ratings, see page 2. For discount on repairs, see page 2. Ordering Examples: 1. Boiler-Burner Unit with jacket lor steam with standard equipment: 1 A-707-SO-8 boiler-bumer lacketed 2. Boiler-Burner Unit less jacket for water with optional equipment: 1 A-710-W0-8 boiler-burner unjacketed with 97-7607 oil burner 3. Boiler only with jacket for steam with optional equipment 1 A-711-S0 boiler with steel pedestal base M*,-4 Page 26 This Price List has been prepared for the convenience of American-Standard distributors and their trade cus tomers only. The tride prices shown represent fixed markups over distributor prices to reflect reasons! and distribution expense end do not purport to represent actual prices prevailing in any partlcula 01689 AMERiCAN-^Standard HYDRONIC HEATING BOILER-BURNER UNITS OIL FIRED BOILERS STIAM ANO WATIK ANTIAEI A I WTMWMAk CbWAIiirmniUhrl<EMIT ELECTRONIC FLAME SAFEGUARD CONTROL EQUIPMENT: For installations requiring Factory Mutual Approval and in states and municipalities with regulations more stringent than UL, oil burners are available with special electronic dame safeguard controls for A-7 boiler-burner units as follows: boiler-burner unit A-705, A-706, A-707 A-708, A-709, A-710 A-711, A-712 A-713, A-714 burner model 96-7509 97-7607 98-7707 97A Hi-Lo 7669 edded Trade Price charge $34.00 15.00 15.00 15.00 Other temperature controls are shown on page 30. 80ILER-BURNER UNITS or OIL FIRED BOILERS: McDonnell-Miller No. 47*2 and No. 51*2 low water cut-off and feeder combinations: No. 47-2 used with A-705 through A-707 and No 51-2 used with balance of sizes. Special equalizer tap ping for bottom connection of No. 51-2 located 6 inches below water line on front section Specify No. 47-2 or No. 51-2 on order at current McDonnell-Miller prices. For No. 369 low water cut-off for use with steam units, see page 30. OIL FIRED BOILERS only: Steel pedestal bases for installation under the regularly furnished 12" base for greater base heights will be furnished when specified on order at the following added charges: section size 5 through 7 8 through 14 base height 8" 10" edded cherge $46.00 78.00 Page 27 This Price List has been prepared for the convenience of American-Standard distributor* and their trade cus tomers only. The trade prices shown represent fixed markups over distributor prices to reflect reasonable selling and distribution expense and do not purport to represent actual prices prevailing 01690 HH-4 OIL BURNERS American-^Standard HYDRONIC HEATING Model 96-7508 OIL BURNERS for A-3, A-5, A-7 and Severn boiler-burner units meters and controls regularly furnished are for 115 vo!t. 80 cycle current modal number I HaaaUM I ** | par hur Ip NiHa dlam. | langth 1 I Trtda mounting [ Price 1 WtTQV. | chipping j woigfct Including constant ignition light sensing primary control with No. 1 steam or No. 3 water control set DH-5 DH-6 45WU-3606 62A-7056-1 62A-7056-1 .55- 3.00 .55- 3.00 3.00- 4.00 4.00- 6.50 4.00- 6.50 4 4 4% 6% 6% k 10% Including electronic flame safeguard primary control with No. 1 steam or No. 3 water control set sling sling flange flange flange $115.15 115.15 159.00 175.00 180.00 55 55 58 79 84 96-7506 6.00-12.00 6% 10% Including electronic flame safeguard primary control with steam or water limit control flange 290.00 107 96-7508 97-7606 98-7706 97A Hi-Lo 7668 6.00-12.00 10.00-17.00 14.00-20.00 12.00-24.00 6 Vi 7 8 7 Vs 10% 10% 10% 10% pedestal pedestal pedestal pedestal 327.00 476.00 501.00 654.00 145 208 214 223 62A-7056-1 burner supplied with 9" draft regulator for A-507 and A-508, and with 12' draft regulator for A-S09 units. bollar-bumar unit oil bumar control* APR APH A-3 packaged DH-5 DH-5 DH-5 f Primary controL light sensing cell and < controls, except thermo stat, factory installed. 1 Draft regulator. A-3 boiler unit. DH-5 A-504 boiler unit DH-5 Severn unit DH-6 /Primary controL Controls. Light sensing < cell factory installed in burner. [Draft regulator. Note; For A-3 units pressure ring is packed with DH-5 burner. For A-504 unit pressure ring, mounting plate and hanger bracket are packed with DH-5 burner. For Severn unit pressure plate, mounting bracket and draft tube sleeve are packed with draft regulator. A-505, A-506, A-507, A-508, A-509 A-510 45WU-3606 62A-7056-1 96-7506-1 (Primary control. Con trol set Light sensing cell factory installed in burner. Note; Model 96-7506-1 furnished with delayed oil valve. Draft regulator. A-511 96-7506 RA890E Protectorelay packed with burner; Q270A base mounted on l burner; C7013A photo cell installed in air tube. Control set Draft regulator. A-705, A-706, A-707 96-7508 RA890E Protectorelay packed with burner; Q270A base mounted on i burner; C7013A photo cell installed in air tube. Limit controL Fire tile. Draft regulator. A-708, A-709, A-710 97-7606 A-711, A-712 A-713, A-714 98-7706 97A Hi-Lo 7668 Note: Delayed oil valve on 96, 97 and 98 burners. One delayed and two mag netic valves on 97A Hi-Lo burner. RA890E Protectorelay packed with burner; C7013A photocell installed in air tube; < W415B1 panel furnished with Q270A base and R488E load relay. Limit controL Fire tile. Draft regulator. DH-5 burners for APR and APH furnished with refractory turbulator and are not interchangeable with other DH-5 models. OPTIONAL ELECTRONIC FLAME SAFEGUARD EQUIPMENT bollar-bumar unit bumtr modal ddad Trada Prica charga A-507, A-508, A-509 62A-7056-1-F (instead of 62A-7056-1) $90.00 A-510 96-7506 (instead of 96-7506-1) 53.00 With RA890E Protectorelay, Q270A base, C7013A photocell, delayed oil valve. For installations requiring Factory Mutual Approval and in states and municipalities with regulations more stringent than UL. oil burners are available with special electronic controls at charges to be added to Trade Prices shown above for burn ers with standard equipment: boiler-bumer unit burner model A-507, A-508, A-509 A-510 A-511 A-705, A-706, A-707 A-708, A-709, A-710 A-711, A-712 A-713, A-714 62A-7056-1-FFM 96-7507 96-7507 96-7509 97-7607 98-7707 97A Hi-Lo 7669 added Trad* Price charge $120.00 87.00 34.00 34.00 15.00 15.00 15.00 Two-stage fuel unit is available for DH oil burners at added Trade Price charge of............................................................... $5.00 Two-stage fuel unit is standard equipment with 45WU, 62A. 96, 97, 97A Hi-Lo and 98 oil burners. V4001A delayed oil valve is available installed on 45WU and 62A burners at added Trade Price charge of..................... $13.00 Controls and control sets are shown on page 30. Ordinal EuapItS: 1. Oil Burner 1 DH-5 oil burner with No. 5 control set end 2.50 gph 60' S nozzle for A-504-WBT boiler-burner unit. 2. Oil Burner * 1 62A-7056-I oil burner with No. 1 control set, two 2.75 gph 80' H nozzles end 9" draft regulator for A-508-SB boiler-bumer unit HM-e Peg* 2B This Price List has been prepared for the convenience of American-Standard distributor* and their Wade cus tomers only. The trade price* shown represent fixed markups over distributor prices to reflect reasonable aaltlns and distribuUon expense and do not purport to represent actual prices prevailing in any parttcuia: 01691 American-^Standard HYDRONIC HEATING OIL BURNERS OIL BURNERS for conversion and replacement motors and controls regularly furnished are for 115 volt, 60 cycle current ---- model number capacity (>. per hour diem. elr tube length Including No 1 st earn or No 3 water control set and constan mounting with control* with primary burner with control and nezdola) nozzfa(s) only only ignition light sen ing primary control if spec ified app. ship, weignt with control sot DH 8 DH 15 DH-23 -52 A 62-1-7000 .65- 3.00 .65- 3.00 .65- 3.00 3.00- 4.00 4.00- 7.00 4 4 4 4 >/, 6`/e 8 15 23 7y, or loy. 16Va f SPECIFY: 1 1 pedestal l 1 0r f l flange J pedestal $115.15 117.15 118.15 155.00 170.00 $103.00 105.00 106.00 141.50 156.50 $ 77.50 79.50 80.50 116.00 131.00 60 64 68 66 73 Optional air lube lengths are available for 52A burner: add to Trade Price for 16^i" length, S3 50; for 22%" length. $5.50. Including No 1 steam or No 3 water control set if specified and electronic flame safeguard primary control 62 2-7002 | 5.00- 8.00 6% 1 16>/e pedestal 275.00 | 261.50 - 84 including steam or water limit control if specified and electronic flame safeguard primary control 96-7501 97-7601 98-7701 97A Hi-Lo 7655 6.00-12.00 10.00 17.00 14.00-20.00 12.00-24.00 6>/e 7 8 7`/a 16 Vi 16`4 16'/. 16% pedestal pedestal pedestal pedestal 290.00 476.00 501.00 654.00 278.50 464.50 489.50 642.50 _ 91 -- 168 -- 176 -- 180 When ordering oil burners be sure to specify nozzle sizes wanted One nozzle is furnished with DH. two nozzles with 52A. 62. and 96. and three nozzles with 97. 98 and 97A Hi-Lo oil burners Nozzles and strainers are as follows: For DH: Hollow cone. 60*. 0 65-1.25 gph Solid cone, 60, 1 35-3.00 gph For 52A, 62, 96, 97, 98, and 97A Hi-Lo: Solid cone. 70. 1.50-2.00 gph. Solid cone. 80, 2.25-6.50 gph. Disc-turbulator combinations furnished with model DH oil burners are as follows: disc-turbulator identification no. capacity range gph nozzle spray angle and typo Hshoilow S=sofid R1 .55-1.10 R2 1.00-1.85 1 .65-1.10 2 .90-1.75 3 1.80-2.30 4 2.35-3.00 60- H 60* H 60" H 60- H (0.90-1.25 gph) 60'S (1.35-1.75 gph) 60- S 60* S The correct disc-turbulator combination is furnished installed in the DH burner for nozzle size specified on order. Two-stage fuel unit is available for DH oil burners at added Trade Price charge of ......................... $5.00 Two-stage fuel unit is standard equipment with 52A. 62, and 90 senes oil burners Electric Clock Thermostat: Substitute T852A for CB-52502 thermostat, specify on oraer control set with suffix "B". and add to Trade Price ....................... $29 40 Controls ana control sets ere shotrn on page 30 Deduct from shipping weight of burner with control set: less control set 3 lbs less control set and primary control 9 lbs. Burners with electronic controls include: oil burner controls 62-2-7002 96-7501 [control set or limit control if specified. JRA890E Protectorelay packed with |burner; Q270A base mounted on burner; iC7013A photocell installed in air tube, 97-7601 98-7701 97A Hi-Lo 7655 [limit control if specified. jRA890E Protectorelay packed with bum per; C7013A photocell installed in air tube; }W415B1 panel furnished with Q270A base land R488E load relay. OPTIONAL ELECTRONIC FUME SAFEGUARD CONTROL EQUIPMENT oil burner controls added Trade Price charge *52A-4322F control set if specified . j RA890E Protectorelay packed jwith burner; Q270A base i mounted on burner; C7013A I photocell installed in air tube : ' add to price of 52A burner $104.00 For installations requiring Factory Mutual Approval and in states and municipalities with regulations more stringent than UL. oil burners are available with special electronic flame safeguard controls as follows: added Trade oil burner Price charge 62-2-7003 96-7502 97-7602 98-7702 97A Hi-Lo 7656 add to price of 62-2-7002 add to price of 96-7501 add to price of 97-7601 add to price of 98-7701 add to price of 97A Hi-Lo 7655 $34.00 34.00 15 00 15 00 15.00 Delayed oil valves are standard on all the above burners with electronic controls One delayed and two magnetic valves on 97A Hi-Lo burners V4001A delayed oil valve is available installed on 52A and 62-1-7000 burners at added Trade Price charge of . S13 00 Ordering Examples: 1. Oil Burner 1 Oh 23 oil Durner w,th No 3 control set, 1 50 gen 60 h nozzle pedestal 2 Oil Burner 1 96-7502 Oil burner with steam lima control, noznes for 11 gph firing rate 01692 Oil burners listed in this Price Book are approved by the Na tional Beard of Fire Underwriters comply with Commercial Standard CS-75 and are for use with No 1 or No 2 fueloil Capacities of oil burners using No 1 or No 2 fueloil are for installations at sea level and at elevations up to 1,000 feet Reduce by 4V for each additional 1.000 feet above sea level For discount on repairs, see page 2. Page .?s This Pr-ce Lis', has been prepared for the convenience of American-Standard distributors and then trade customers oni> The trade prices shown represent fixed r-.v k... rt over distributor prices to reflect reasonable selling anc ais'.nojlion evpenve and do not purport to rep-ese-;t ac'ua! prices prevailing in any namrular market. HH-4 CONTROL SETS, CONTROLS LOW-WATER CUT-OFF ZONE VALVE PACKAGES AMERiCAN-cStandard HYDRONICHEAT INQ CONTROL SETS FOR BOILER-BURNER UNITS 1 Control set no. 1 staam no. 2 staam for boiler without domestic hot water boiler with year-round domestic hot water, tankless heater no. 3 gravity water no. 4 forced water boiler without domestic hot water, immersion control boiler without domestic hot water no. 5 A-3 and A-5 units only with year-round domes forced weter tic hot water no. 5-Z forced water no. 6 forced water A-3 and A-5 units only. (1 no. 5-Z set is re quired for each zone in addition to the first zone which is controlled by the no. 5 control aet.) boiler with year-round domestic hot water, storage tank heater no. 7 boiler with year-round domestic hot water, forced water tankless heater control number contents of control sot description CB-52502 PA404A CB-52502 PA404A L4006A CB-52502 L4080 CB-52502 L4062B CB-52502 L8024A CB-52502 R845A Thermostat Pressuretrol Thermoatat Pressuretrol Aquastat operating control Thermostat Aquastat limit control Thermostat Aquastat limit and circulator control Thermoatat Aquastat limit, reverse and operating control, circulator relay Thermostat Relay CB-52502 L4006A L4080 R845A CB-52502 L6006A 14080 RA89A Thermostat Aquastat operating control Aquastat limit control Relay Thermostat Aquastat operating and circulator control Aquastat limit control Relay add to Trad* Price ef dj basic control eet $10.00 $ 5.80 $14.55 $19.35 $24.30 $22.45 number description CONTROLS Trade Price number description Trade Price CB-52502 CB-65653 CB-65655 CB-65690 CB-85111 CB-26203 AY-553 AY-686 AY-552 AY-687 TS88A /T832A T852A L4006A AMERICAN-STANDARD Horizontal thermostat, low voltage, adjustable heater, 0.3 to 1.0 amp 3. i3 Limit or operating control Reverse acting control Limit or operating control (millivolt) Circulator-limit control Relay High range limit control Low range limit control High range limit control (millivolt) Low range limit control (millivolt) HONEYWELL Thermostat (millivolt) Thermostat, low voltage, manual turndown Thermostat, electric clock Aquastat operating control $ 5.10 8.44 8.44 8.44 14.36 12.60 3.00 3.00 3.00 3.00 L4080 L4062B , L6006A R8182A R8182C L8024A . fftx ' L8024G 4.73 21.96 34.91 10.13 PA404A RA89A 3"R845A R8184A 120272 Aquastat limit control Aquastat limit and circulator control Aquastat operating and circulator control Aquastat-relay combination, high limit, low limit and circulator control, light sensing constant ignition primary control Aquastat combination, limit and circulator control, light sensing constant ignition primary control Aquastat limit, reverse and 1. operating control, circulator relay Aquastat limit control, switching relay and transformer Pressuretrol Relay, SPST Relay. DPST Light sensing constant ignition primary control Cadmium cell only $ 8.44 14.29 11.18 45.75 37.76 23.18 25.43 11.51 11.55 14.51 24.94 1.88 No. 369 McDonnell L Miller low water cut-off for automatically fired steam A-5, A-7. Severn and Exbrook boilers and/or boiler-burner units.................................. Trade Price each $16.75 HYORONIC ZONE VALVE MANIFOLD PACKAGES Assembled zone valve manifold packages utilize the thermostat furnished with American-Standard gas and oil packaged units. When the listed packages are to be used with other forced hot water installations, an additional 2-wire thermo stat is needed to control the first zone, No. 2-Z package for 2 zones 1 CB-52502 thermostat 2 ZV 20000 s/t" 24 volt zone valves assembled to manifold 1 40 VA transformer Trade Price......... $51.00 No. 3-Z package for 3 zones 2 CB-52502 thermostats 3 ZV-20000 3/," 24 volt zone valves assembled to manifold 1 40 VA transformer Trade Price....................... $76.00 ZV-20000 24 volt zone valve.................................... *....................................... Trade Price each $18.00 note.- RA89A relay for intermittent circulator operation with zone valves-see Trade Price above. HN-4 P*g* 30 Thu Price List hu been prepared for the convenience of Amencan-Sundard distributor* and their tr-a- tomer* only. The trade prices shown represent fixed markups over distributor prices to reflect reasons! and distribution expense and do not purport to represent actual prices prevailing in any particula 01693 AMERiCAN-<$tandard HYDRONIC HEATING STOKER FIRED BOILERS HUM ANO WATtt SEVERN STOKER FIRED BOILERS Flush jacket. ----------------------------------------------------- 1-------------- -- i - boiler number gross output STEAM WATER Wbh firing rate pounds per hour net Installed rating so ft stssm Mbh sq ft water Not adapted for Built-in Water Heater (see options below) Tradt Price appv*. shipping weight SC-17 (T) SC-21 (T) SC-25 (T) WC-17 (T) WC-21 (T) WC-25 (T) 146 16 168 18 188 21 SC-29 (T) S' ~3 (T) 1 J7 (T) WC-29 CO WC-33 (T) WC-37 (T) 216 24 247 27 278 31 Suffix *T" denotes boiler arranged for but less built-in heater. 456 525 588 675 772 869 109.5 126.0 141.0 162.0 185.3 208.6 730 840 940 1080 1235 1390 5355.00 397.00 436.00 479.00 542.00 600.00 1053 1220 1301 1457 1534 1687 Standard equipment: For Steam: Steam gauge. ASME safety valve, gauge glass and trimmings. For Water: Pressure and temperature gauge, ASME relief valve. Optional equipment: Boilers arranged for but less Built-in heaters: If desired, for use with heaters No. 590. 594 and 595, add suffix letter "T" to boiler number and add $6.00 to Trade Price of boiler with standard equipment. If 2Vt" right or left side tapping in back section for Built-in heater No. 703 is desired, specify on order and add $2.00 to Trade Price of boiler. For low water cut-off for use with steam Severn boilers, see page 30. Cover plate for water heater opening will be furnished if specified on order for "T" type boiler at an added Trade Price charge of $3.70. Below are the ratings and Trade Prices for Built-in heaters available for Severn stoker boilers. For detailed information on ratings, see page 2. Hsstsr No. 703 594 595 590 Hester Typo tank tank tank tankless HestsrMtings gals, flbpacity 66 100 160 31/2 per minute Tradt Prieo $ 9.00 48.00 42.50 36.00 approx. shipping wslght 7 54 51 60 Ordering Eumples: 1. Boiler for water with standard equipment: 1 WC-25 boiler 2. Boiler for steam and arranged tor but less built-in heater: 1 SC-33-T boiler HPtPS: For complete information on boiler ratings, see page 2. For discount on repairs, see page 2. 01694 Page 31 This Price List has been prepared for the convenience of American-Standard distributors and their trade cus tomers only The trade prices shown represent fixed markups over distributor prices to reflect reasonable selling and distribution expense and do not purport to represent actual prices prevailing In any particular market. HH-4 STOKER FIRED BOILERS ITtAM AMO WATVR American-Standard HYDRONIC HEATING EXBROOK STOKER FIRED BOILERS Flush Jacket. boiler number STEAM WATER greet output Mbh IstsR burner cepedty 1 be/hr net l=B =R reting *q teem Mbh Not adapted for Built-in Water Heater (see options below) net rating iq ft water Trade Price approx. size hipping weight SC-207(T) SC-208(T) SC-209(T) WC-207(T) WC-208(T) WC-209(T) 276 30 863 207.1 1380 $607.00 8x12x25 2150 335 37 1047 251.3 1675 684.00 8x12x25 2313 396 43 1238 297.1 1980 761.00 12x12x30 2628 SC-2010CT) SC-2011 CD SC-2012CO SC-2013(T) WC-2010(T) WC-2011(T) WC-2012CO WC-2013(T) 452 50 508 56 564 62 620 68 1413 1588 1763 1938 339.1 381.1 423.1 465.1 2261 2541 2821 3101 838.00 916.00 994.00 1071.00 12x12x30 12x12x35 12x16x40 12x16x40 Suffix 'T" denotes boiler arranged for but less built-in heater. Standard equipment: For Steam: Steam gauge. ASME safety valve, gauge glass and trimmings. For Water Pressure and temperature gauge. ASME relief valve. 2821 3134 3309 3641 Optional equipment: Boilers arranged for but less Built-in heater: If desired add suffix letter "T" to boiler and add $6.00 to Trade Price of boiler with standard equipment. Built-in water heaters are available for use with Exbrook "T" type boilers only. Cover plate for water heater opening will be furnished if specified on order for "T" type boiler at added Trade Price of $4.25. For low water cut-off for Exbrook steam boilers, see page 30. Below are the ratings and Trade Prices for Built-in heaters available for Exbrook "T" type Stoker boilers. Heater No. 591 592 Heater Type tank tank Heater Ratings gala, capacity 120 200 Trade Price $32.50 46.50 approx. shipping weight 35 53 HH-4 Ordering Examples: 1 Boiler for steam with standard equipment 1 SC-209 boiler 2. Boiler for water and arranged for built-in heater: 1 WC-2011-T boiler 1 Heater opening cover plate Notes: For complete information on boiler ratings, see page 2. For discount on repairs, see Cage 2 Page 32 This Price Lost Kas been prepared for the convenience of American-Standard distributors and their trade cus tomers only. The trade pnees shown represent fixed markups over oistnouior prices to reflect reasonable se and distribution expense and do nol purport to represent actual prices prevailing in any particular ma 01695 boiler number STEAM WATER 3-SC-8 3 SC-9 3-WC-8 3WC-9 American-Standard HYDRONIC HEATING STOKER FIRED BOILERS STIAM AND WATIK output Mbh 706 798 NO. 3 REDFLASH STOKER FIRED BOILERS Jacketed and unjacketed. firing rote pound* per hour 78 88 net Inetellod rating aq ft eteem Mbh q ft water 2207 2494 529.6 598.6 3531 3991 unjacketed Trade Price approx. shipping weight $1135.00 1260.00 3652 4041 jacketed Trade Price approx. shipping weight $1227.00 1356.00 3827 4224 Standard equipment: For Steam: Steam gauge, ASME safety valve, gauge glass and trimmings. For Water: Pressure and temperature gauge, ASME relief valve. Optional equipment: External water heater tappings available at following added charges: ping and $2.00 per jacket punching. Ordering Eiamples: Soiler for steam noth jacket with standard equipment: 1 3-SC-9 jacketed boiler $2.00 per section tap A-7 STOKER FIRED BOILERS Jacketed and unjacketed. Tested and equipped for 50 lbs. water working pressure. boiler number STEAM WATER gross IsBsR output Mbh l=B = R burner capacity Ibs/hr net l=B =R rating sq ft eteem Mbh net rating sq ft water A 705-SC A-706-SC A-707-SC A-705-WC A-706-WC A-707-WC A-708SC A-709SC A-710-SC A-708-WC A-709-WC A-710-WC A-711-SC A-711WC A-712-SC A-712-WC A 713 SC A-713WC A-714SC A-7I4-WC 866 1012 1196 1376 1570 1760 1956 2148 2340 2532 95 111 131 151 172 194 215 236 257 278 2707 3163 3738 4340 5013 5672 6328 6949 7570 8191 649.7 759.2 897.2 1041.6 1203.1 1361.2 1518.6 1667.7 1816.8 1965.8 4331 5061 5981 6944 8020 9075 10125 11118 12112 13105 chimney size unjacketed Trade Price approx. shipping weight jack* ted Trade Price approx. shipping weight 16 * 16 x 28 16 x 16 x 30 16 x 20 x 36 16 x 20 x 42 16 x 20 x 45 20 x 20 x 50 20 x 20 x 55 20 x 20 x 60 20 x 24 x 70 20 x 24 x 80 $1260.00 1380.00 1555.00 1725.00 1877.00 2055.00 2227.00 2397.00 2567.00 2739.00 3882 4518 5149 $1341.00 1473.00 1660.00 5720 6330 6990 1842.00 2006.00 2196.00 7556 2380.00 8208 2562.00 8912 9616 2744.00 2928.00 4054 4693 5332 5929 6545 7209 7817 8506 9182 9886 Standard equipment: For Steam: Steam gauge, ASME safety valve, gauge glass and trimmings. For Water: Pressure and temperature gauge. ASME relief valve for 50 lbs. Optional equipment: Steel pedestal bases for installation under the regularly fur nished 12" base for greater base heights, will be furnished when specified on order at the following added charges: section size 5 thru 7 8 thru 14 bass heights 8" 10" trade pnee 546.00 76.00 For low water cut-off for A-7 steam boilers, see page 30. Ordering Examples: Boiler for water with jacket w.tft opuona1 .eouiomenl 1 A-708-WC jacketed boiier 1 8" steel pedestal base Notes: For complete information or. boiler ratings, see page 2. For discount on repays see page 2. 01696 Page 33 This Price List has been prepared for the convenience of American-Standard distributors and their trade cus tomers only The trade prices shown represent fixed markups over distributor prices to reflect reasonable selling and distribution expense and do not purport to represent actual prices prevailing in any particular market. HH-4 HAND FIRED BOILERS STLAM AND WATIt AMERicAN-^tandard HYDRONIC HE ATI NO STEAM boilor number WATER S-17 S-21 S-25 S-29 S-33 S-37 W-17 W-21 W-25 W-29 W-33 W-37 SEVERN HAND FIRED BOILERS F*!ush jsckst. frost output Mbh aqft ataam not Installed rating Mbh watar 194 244 296 328 364 396 353 84.7 453 108.7 553 132.7 565 725 885 630 151.3 1009 710 170.5 1137 783 187.9 1253 $393.00 456.00 522.00 574.00 632.00 681.00 approx. shipping wsight 1243 1413 1521 1686 1783 1956 Standard Equipment: For Steam: Steam gauge, ASME safety valve, gauge glass and trimmings, automatic damper regulator and firing tools. For Water Pressure and temperature gauge. ASME relief valve, automatic damper regulator and firing tools. Built-in Heaters: If 2t4" right or left side tapping in back section for Built-in screw-in heaters No. 701, 702 or 703 is desired specify on order and add $2.00 per tapping to Trade Price of boiler. Below are the ratings and Trade Prices of Built-in heaters available for Severn hand fired steam boilers. Hsator No. Hsator Typo Hoator ratings gals, capacity Trado Pries approx. shipping weight 701 702 703 tank tank tank 60 40 100 $8.50 8.00 9.00 5 4 7 Note: Built-in water heaters are not recommended for hand fired water boilers. Otderiag Example: Boiler for steam with built-in heater: 1 S-25 boiler with 2V4" tapping on right hand side of back section 1 702 heater Notts: For complete information on boiler ratings. see page 2. ; :' For discount on repairs, see ptge 'L Pete 34 This Price List has been prepared for the convenience of American-Standard distributors and their trade cus tomers only. The trade prices shown represent fixed markups over distributor prices to reflect reasonable ' and distrlbuuon expense end do not purport to represent actual prices prevailing in any particular 01697 STEAM boiler number WATER 2S-7 2-S-8 2-S-9 2-S-10 2-S-l 1 2S-12 2-W-7 2-W-8 2W-9 2-W-10 2-W-ll 2-W-12 Ame mcAN-<Standard HYDRO NIC HEATING HAND FIRED BOILERS STtAM AND WATH NO. 2 REDFLASH HAND FIRED BOILERS Jacketed and unjacketed. (rote output Mbh net Installed ratine *q ft teem Mbh eqft water unjeclrated Trade Price approx. hipping weight Jacketed Trade Price approx. thlpplng weight 464 S36 606 676 744 812 940 1111 1281 1453 1623 1794 225.7 266.7 307.5 348.8 389.5 430.5 1505 1778 2050 2325 2597 2870 $ 707.00 785.00 863.00 942.00 1021.00 1099.00 2293 2466 2782 2999 3313 3503 $ 775.00 857.00 939.00 1022.00 1105.00 1187.00 2390 2572 2897 3122 3446 3644 Standard Equipment: For Steam: Steam gauge. ASMS safety valve, gauge glass and trimmings, automatic damper regulator and firing tools. For Water Pressure and temperature gauge, ASME relief valve, automatic damper regulator and firing tools. Ordering Example: Boiler for steam less jacket with standard equipment: 1 2-S-9 boiler unjacketed boiler number STEAM WATER 3-S-6 3 S-7 3 S-8 3-S-9 3-W-6 3-W-7 3-W-8 3-W-9 NO. 3 REDFLASH HAND FIRED BOILERS Jacketed and unjacketed. grots output Mbh net installed rating tq ft steam Mbh eq ft water unjacketed Trade Price approx. shipping weight Jacketed Trade Price approx. shipping weight 696 814 932 1046 1503 1799 2100 2400 360.6 431.8 504.1 576.0 2404 2879 3360 3840 $ 963.00 1107.00 1251.00 1395.00 3243 3698 4110 4549 $1047.00 1195.00 1343.00 1491.00 3397 3870 4285 4732 Standard Equipment: For Steam: Steam gauge, ASME safety valve, gauge glass and trimmings, automatic damper regulator and firing tools. For Water: Pressure and temperature gauge, ASME relief valve, automatic damper regulator and firing tools. Note: Buckwheat coal grate bars will be furnished at no additional charge when specified on order. Ordering Example: Boiler for water with jacket with standard equip, ment. ... ..^ i 1 3-HSJ So:ler jacketed .fzf' complete information on boiler ratings, see page 2. For discount on repairs, see page 2. 01698 Page 35 This Price List has been prepared for the convenience of American-Standard distributors and their trade cus tomers only The trade prices shown represent fixed markups over distributor prices to and distribution expense and do not purport to represent actual prices prevailing ir HH-4 HAND FIRiD BOILERS IT1AM AM# WATU AMERicAN^landard HYDRONIC HEATING '..i* . .c ' * 7 HAND FIRED BOILERS Jacketed and unjacketed. Tcried and equipped for SO Iba. water working preaaure. boiler mimbor STEAM WATER .35. SMSDBf?l * not Is:SssR qft steam Ubh not rating *9 ft water chbnnoy six* unjodtoted Trod# Prico approx. as? II Jacfcatad approx. A-705-S A-705-W 1122 2606 625.4 4169 16x16x40 $1393.00 4294 $1474.00 4466 A-706-S A-706-W 1298 3101 744.3 4962 16 x 20 x 45 1519.00 5006 1612.00 5181 A-707S A-707-W 1510 3725 894.0 5960 20 x 20 x 50 1696.00 5738 1801.00 5921 A-708-S A-708-W A-709-S A-709-W 1708 1910 4342 5008 1042.1 1202.0 6947 20 x 20 x 55 8013 20 x 20 x 60 1877.00 6392 1994.00 6601 2006.00 7199 2135.00 7334 A-710-S A-710-W 2108 5681 1363.5 9090 20 x 24 x 65 2164.00 7858 2305.00 8077 A-711-S A-711W 2288 6326 1518.2 10122 20 x 24 x 70 2336.00 8506 2489.00 8767 A-712-S A-712-W 2456 6947 1667.3 11115 24 x 24 x 75 2496.00 9231 2661.00 9529 Standard equipment: For Steam: Steam gauge, ASMS safety valve. Gauge glass and trimmings, automatic damper regulator and firing tools. For Water. ASMS relief valve for 50 lbs. Automatic damper regulator and firing tools. Pressure and temperature gauge. Ordariag Esaaplc: Boiler for water with jacket with standard equipment: 1 A-706-W boiler jacketed Notes: For complete information on boiler ratings, see page 2. For discount on repairs, see page 2. HH-4 Pag* 36 This Price List has been prepared for the convenience of American-Standard distributor* and their tr: tomers only. The trade price* shown represent fixed markups over distributor price* to reflect reasonabli - - ------ -- ' W. f iws st V TiSfUri AMERiCAN-cStandard HYDRONIC HEATINQ RADIATORS RADIATOR ACCESSORIES width height* inches aq ft par section Trade Price per sq ft 6 tube 32 3.7 $1.25 3 tube 25 1.6 1.25 4, 5. 6 tube 25 2.0, 2.4. 3.0 1.18 4. 5 tube 22 1.8. 2.1 1.23 4, 6 tube 19 1.6, 2.3 1.25 Arco Radiaton are regularly furnished with two and one-half Inch <2V4") legs but can be supplied on Special Order with four and one-half inch (4V4") legs, or without legs, at no extra charge. Area Radiators sold only In even number of sections up to a maximum of 56 sections. For purpose of estimatinp shippinp toeights, use 4H pounds per sq. ft. Ordering trample: 1-12 Section 25* Arco 4 Tube Legless Vi * V4 SUNRAD RADIATORS type sq ft per section Trade Price per eq ft M 5 x 20 M 7`/2 x 23 2.25 3.40 $1.49 1.56 Sunrad Radiators are regularly furnished with two and threequarter inch (2 V) legs but can be supplied on special order without legs, at no extra charge. Sunrad Radiators sold in even number of sections from 4 to 30 sections, and in odd number of sections with center leg from 31 to a maximum of 45 sections. Important: Increase size 5% for recessed installation-- Vi" air space top and sides. l/j" at back. Increase size 15% for tightly recessed in stallation--no clearance top or sides. xhm air space at back. Sunrad Grilles Inlet--Stamped Lattice Type.......................... per section $0.19 Special No. 16 Gauge with Locking Device................. Price on application Tor purposes of estimating shipping weights, use 6 pounds per sq ft for MS x 20. Ordering Eumple: use pounds per sq ft for M7% x 23. 1-10 Section M5 x 20 Sunrad T-4 x Vz 1-Type M Sunrad Grille for above. 01700 RADIATOR ACCESSORIES Arco Brackets: For 3, 4. 5, 6 tube, with Wall Plate............................... Trade Price *ch $0.83 Nipples, Plugs, Bushings, etc.: 3/,'\ 1". 1'/,", 1 >/2" Plugs. Bushings Trade Price *>ch SO.23 Arco Radiator Pedestals: l/2" and 1 ' ................................................................. 1V2" .................................................... 0-32 0.41 V,". 1". I1/," Slip Nipples. .............. l/a" Air Vent Plugs .................................................. Radiator Rod Nuts......................................................... 0.23 0 01 0.01 Sunrad B.ackets: Per Mb ; 20 and M7>/2 x 23 ... 0 65 Radiator Rods................................................per section 0.01 Above items available for use only with our Radiator products Page 37 This Price List has been prepared for the convenience of American-Standard distributors and their trade cus tomers onl> The trade prices shown represent fixed -*arkups over distributor prices to reflect reasonable selling and distribution expense and do not purport to represent actual prices prevail-- -- ------ -- HH-4 BASEBOARD PANELS American-Standard HYDRONIC HEATING RADIANTRIM BASEBOARD PANELS VK'R/ New Model 8 Steam Rating per lineal foot 2.75 $q ft SEE CURRENT LITERATURE FOR APPROVED l=B=R STEAM AND HOT WATER RATINGS par linaal foot Trada Prtca-- $3.08 par tquara foot $1.12 New Model 8 Radiantrun Panel lengths (2% ft to 30 ft) are made up from the following sections: Hi ft Left hand end section 1 ft Right hand end section 2 ft Left hand end section 2 ft Right hand end section 2 ft Center section Assembly length with legs and tappings at each end: 2 ft Double end section New Model 8 Accessories Vnc. Extension Panel and Brackets (Two 6 ft lengths per box) .................................. $8.40 Extension Panel Retaining Bracket........................... 0.22 Extension Panel Cover Strip ...................................... 0.53 Assembly Clamp ........................................................... 7.70 Short-- Compression Corner Connection ............. 2.00 Long -- Compression Corner Connection................. 2.25 Retaining Block ................. 0.15 Adjustable Leg ............................................................... 0.20 Theta itemt are regularly furnished at required with New Model 8 Radiantrim Panels and Accessories. Prices are shown for repair or replacement purposes. Packed in quantity of 10 per box (Available only in this minimum quantity) par box of 10 Inverted Corner Cover . ... ........................................ $10.50 Extended Inverted Corner Cc ver.................................. 17.50 Projecting Corner Cover .. ........................................ 14.20 Valve-Enclosure (all R.H. or L.H.) .............................. 12.35 End Box (all R.H. or LH.) 7 00 Tor purpose of estimating shippmj weights, use *V pounds per sq ft . 12 16 pounds per lineal foot Ordering Example: 1-7 ft New Model 8 Radiantrim l anel I-Box of New Model 8 Inverted C Drner Covers. par linaal foot Trada Prica-- $341 per square foot $1.12 Model 10 Radiantrim Panel lengths (2H ft to 30 ft) are made up from the following sections: 1 Vi ft Left hand end section 2 ft Left hand end section 1 ft Right hand end section 2 ft Right hand end section 2 ft Center section Assembly length with legs and tappings at each end: 1 Vi ft Double end section 2 ft Double end section Model 10 Accessories V*ce Extension Panel and Brackets (Two 6 ft lengths per box) ...................................... $13 io Extension Panel Retaining Bracket........................... 0 22 Extension Panel Cover Strip...................................... 0.53 Assembly Clamp............................................................. 7.70 Short -- Compression Corner Connection........... 2 00 Long -- Compression Corner Connection ... 2.25 Retaining Block ............................................................. 0.15 Adjustable Leg ............................................................... 0.20 These items are regularly furmshad as required with Model 10 Reqiantrim Panels and Accessories. Prices are shown for repair or re placement purposes. Packed in quantity of 10 per box Vnce (Available only in this minimum quantity) perboxoflO Inverted Corner Cover .................................................... $13.10 Extended Inverted Corner Cover................................ 23.60 Projecting Corner Cover................................................ 16.60 Valve Enclosure (all R.H. or L.H.) .............................. 18.35 End Box (all R.H or L.H.) ............................................ 9 80 For purpose of estimating shipping weights, use 4 J4 pounds per sq ft . 16.15 pounds per lineal foot. Ordering Example: 1-7 ft Model 10 Radiantrim Panel 1 --Bor of Model 10 Right Hand Valve Enclosures BvtNr 1 2 | i 1 EXTRA RADIANTRIM ACCESSORY BAGS For Trade Price Bag No. For Double Leg Section 2Mr'-6' Panel Length 6 Vi -12' Panel Length $ .65 .80 ______1._80________ 3 12Vi'-18' Panel Length 4 18*'-24' Panel Length 5 24 % '-30- Panel Length Sufficient quantities ol these bags are regularly furnished with Radiantrim Panels Prices shown are for extra bags as may be required. Trade Price $2.65 3.50 4.50 HH -4 Page 38 This Price List has been prepared for the convenience of American-Standard distributors and their trade cus tomers only The trade prices shown represent fixed markups over distributor prices to reflect reasonable sellli ar.d distribution expense and do not purport to represent actual prices prevailing in any particular mark! 01701 AMERiCAN-<Standard hydronic heating HEATRIM PANELS HEATRIM BASEBOARD PANELS MEMICK Model N50-L (Vi' tube) Model N50-HH (Vi* I I \ Model N85L (*/' tube) Model N85-HH (%' tube) Model N110-L (1' tube) Model N110-HH (l'tube) SEE CURRENT LITERATURE FOR APPROVED l=B=R HOT WATER RATINGS COMPLETE UNITS: approx. hipping waight Trad* Plica Model N85-L-Packaged in 3', 4', 5', 6', 7' and 8' lengths-com- per 3 ft. length pletely assembled (package contains element, one-piece back per 4 ft. length and top section, front panel damper, snap-in support brack- per 5 ft. length ets. element slide cradles and 1 set damper joining pieces). per 6 ft. length Finished with white prime coat of paint. per 7 ft. length I Ordering Example: 1-N85-L, 3 ft. length, Heatrim unit. per 8 ft. length *per lineal foot Model N85HH-Packaged in 3', 4', 5', 6'. T and 8' lengths-completely assembled (package contains element, one-piece back and top section, front panel, damper, snap-in support brackets. element slide cradles and 1 set joining pieces). Finished with white prime coat of paint. Ordering Example: 1--N85-HH, 7 ft. length, Heatnm unit. per 3 ft. length per 4 ft. length per 5 ft. length per 6 ft. length per 7 ft. length per 8 ft. length *per lineal foot 9 11 14 18 20 22 2 Vi 10 13 16 20 23 26 3 Vi $ 5.85 7.80 9.75 11.70 13.65 15.60 1.95 7.35 9.80 12.25 14.70 17.15 19.60 2.45 HEATING ELEMENTS ONLY: Model NSO <%" tube)-Individually boxed.packaged six equal lengths per bundle. Ordering Example: 1--Bundle NSO. 3 ft. lengths, Heatrim elements. per bundle of six 3' lengths per bundle of six 4' lengths per bundle of six 5' lengths per bundle of six 6' lengths per bundle of six 7' lengths per bundle of six 8' lengths *per lineal foot 10 13 17 22 25 28 Vi 16.20 21.60 27.00 32.40 37.80 43.20 .90 Model N85 (" tube) - Individually boxed, packaged six equal lengths per bundle. Ordering Example: l-8unaie of N85. 5 ft lengths, Heatrim elements. per bundle of six 3' lengths per bundle of six 4' lengths per bundle of six 5' lengths per bundle of six 6' lengths per bundle of six T lengths per bundle of six 8' lengths *per lineal foot 12 16 19 24 27 30 Vi 18.00 24.00 30.00 36.00 42.00 48.00 1.00 Model N110 d" tube) - Individually boxed, packaged six equal lengths per bundle. Ordering Example: 1-Bundle of N110. 6 ft. lengths. Heatrim elements. per bundle of six 3' lengths per bundle of six 4' lengths per bundle of six 5' lengths per bundle of six 6' lengths per bundle of six 7' lengths per bundle of six 8' lengths *per lineal foot 13 Vi 18 22Vi 27 31 Vi 36 % Foe comDr*tiv and animating purpota* only. Page 39 ThU Price List hjj been prepared for the convenience of American-Standard distributors and their trade cus tomers only The trade prices shown represent fixed markups over distributor prices to refle<" r*AR*hi aUins and distribution expense and do not purport to represent actual prices prevailing m an 21.60 28.80 36.00 43.20 50.40 57.60 1.20 HH-4 01702 HEATRIM PANELS AND ACCESSORIES American-^Standard HYDRONIC HEATING HEATRIM BASEBOARD PANELS ill -!r ENCLOSURES ONLY: Model 1-MuHiple packaged in 3', 4'. 5', 6', T, 6', 10' and 12' icfigito utisitiiiuieu-kIiKC cCjmju lehglha pc* wOX < paCkdgtr contains 3 one-piecc back and top sections. 3 front panels. 3 dampers, loose snap-in support brackets, element slide cradles and 2 sets joining pieces' Finished with white prime coat of paint Ordering tnmplt: 1-Boi 5 ft lengths Model L Enclosure only per box of three 3' lengths per oox of three 4' iengtns per box of three 5' lengths per box of three 6' lengths per box of three 7' lengths per box of three 8' lengths per box of three 10' lengths per box of three 12' lengths per lineal foot Model L-lndividually packaged in 3'. 4'. 5'. 6`. 7' and 8' lengths unassembled (Package contains one-piece back and top sec tion. front panel damper, loose snap-in support brackets, ele ment slide cradles and 1 set joining pieces). Finished with white prime coat of paint. Ordering Example: 1-7 ft. length Model l Enclosure only. per 3 ft. length per 4 ft. length per 5 ft. length per 6 ft. length per 7 ft. length per 8 ft. length per lineal foot Model HH-Multiple packaged in 3'. 4'. 5'. 6'. 7' and 8' lengths unassembled-three equal lengths per box (package contains 3 one-piece back and top sections. 3 front panels. 3 dampers, loose snap-in support brackets, element slide cradles and 2 sets joining pieces) Finished with white prime coat of paint Ordering Example.- 1-Box 4 ft lengths Model HH Enclosure only. per box of three 3' lengths per box of three 4' lengths per box of three 5' lengths per box of three 6' lengths per box of three 7' lengths per box of three 8' lengths per lineal foot Model HH-Individually packaged in 3`. 4\ 5'. 6'. 7' and 8' lengths unassembled (Package contains one-piece back and top section, front panel, damper, snap-in support brackets, element slide cradles and 1 set joining pieces' Finished with white prime coat of paint Ordering Example: 1-3 ft. length Model HH Enclosure only. per 3 ft. length per 4 ft. length per 5 ft. length per 6 ft. length per 7 ft. length per 8 ft. length per lineal foot HEATRIM BASEBOARD PANEL ACCESSORIES 21 27 34 41 48 54 68 82 2 8 10 12 14 17 19 2 24 30 38 46 52 V2 59 2>/2 8 11 14 16 17 V2 21 2V? MOOEL L ENCLOSURE ACCESSORIES: Inverted Corner Cover-one-piece front and top section. Inverted Corner Cover-hmged front and top section. Inverted Corner Cover-back section only ....................... Projecting Corner Cover ....................................................... Valve Enclosure-6" wide................. packed all right ha1 End Cover-4" wide..................... .. packed all right ha End Cap-1 4" wide. . . ..............packed all right ha Wall End Piece-3J/4" wide Filler Pieces-7" wide Filler Pieces-14" wide ............................................................. Joining Pieees-2" wide .... Return Tubing Wire Hangers-for 4" and 34" tubing only Connecting Tubing Wire Hangers-for V and 3/<" tubing o Extra Snap-in support bracket with slide cradle. Not#: Finished with white prime coat of paint ............. packed per box of 10 packed per box of 10 packed per box of 10 . packed per box of 10 or all left hand per box of 10 or all left hand per box of 10 or all left hand per box of 10 ......... packed per box of 10 ........... packed per box of 10 . . . packed per box of 5 packed per box of 20 sets packed per bag of 50 v packed per bag of 50 packed per box of 20 sets MODEL HH ENCLOSURE ACCESSORIES: Inverted Corner Cover-one-piece front and top section Inverted Corner Cover-hinged front and top section .. Inverted Corner Cover-back section only Projecting Corner Cover packed per box of 10 packed per box of 10 packed per Pox of 10 packed per box of 10 Valve Enclosure-6" wide End Cover-4" wide . End Cap-1 *4" wide . Wall End Piece-34" wide . packed all right hand or ail left hand per box of 10 packed all right hand or all left hand per box of 10 packed all right hand or all left hand per box of 10 packed per box of 10 Filler Pieces--14" wide ......................... Joining Pieces-2" wide Retuir. Tubing Wire Hangers-for 4". 4" and 1" tubing Connecting Tuning Wire Hangers-for 4". 3" and 1" tubing Extra Snap-in support bracket with slide cradle packed per box of 5 packed per box of 20 sets packed per bag of 50 packed per bag of 50 packed per box of 20 sets Noia: Finished with white prime coat of paint 'For uor.iparative and estimating purposes only. hotl Aad 2!7c to accessory unit price v.hen ordered in less than quantities indicated above. 3 3 4 6 12 10 5 4 10 9 5 4 4 6 7 16 12 6 6 12 6 hh-4 Page 40 Thi< Price List has been prepared for the convenience of American-Standard distributors and their trade cu;lomers on!> Tre 'raae prices sr.own represent fixed markups over d striDuior prices to reflect reason* bit Jnd d'Si'iCution expense and do not purport to represent jf.. .. prices Prevailing in any particular Trad* Pric* $ 7.20 9.60 12.00 14.40 16.80 19.20 24.00 28.80 .60 2.70 3.60 4.50 5.40 6.30 7.20 .90 12.06 16.08 20.10 24.12 28.14 32.16 1.34 4.35 5.80 7.25 8.70 10.15 11.60 1.45 $ 8.00 10.50 4.50 10.00 17.50 12.50 5.00 3.00 6.50 6.00 5.00 2.00 2.00 7.00 8.00 10.50 4.50 11.50 18 00 12.50 8 00 4.00 7.75 7.00 2 00 2 00 7.00 01703 American-^Standard hydronic heating convectors ARCO CONVECTORS SPECIAL SERVICE LINE when sold in combination with standard cabinets COMBINATION PRICE: The actual output in square teet of catalog rating-Steam (2159F) obtained with the cabinet heights furnished deter mines the price of convectors and cabinets sold in combination The total price of each order equals the amount of catalog square feet ordered multiplied by the price per square foot, plus the unit extra charge multipled by the total number of units ordered. SEE CURRENT LITERATURE FOR STEAM AND HOT WATER RATINGS cabinet type desenption Trad* Price %Pqfrt unit extra charge F FG w FS FSG S FR FRG FRGB Floor Type-free standing . .. Floor Type-free standinginlet grille ......................... Wall Hung-flat top ............. Free Standing-sloping top ... Free Standing-sloping topinlet grille............................ Wall Hung-sloping top Fully recessed-^/' beveled edges Fully recessed-^," beveled edges-inlet grille Fully recessed-^,/' beveled edges-inlet grille with bottom overlap 51.35 1.39 1.35 1.42 1.45 1.35 1.34 1.38 1.38 $17.10 17.10 17.10 17.95 17.95 17.10 18.15 18.15 21.30 cabinet type description Trade Price par sq ft unit extra charge PR Partially recessed-lV'. l'V', 2V4", 3". 5". 7" flanged edges $1.34 $19.75 PRG Partially recessed-^". llV\ 2^. 3". 5". 7" flanged edgesinlet grille 1.38 19.75 PRGB Partially recessed--V. IV', 2V4. 3". 5". 7" flanged edgesinlet gnlle-with bottom overlap PFG Plaster Front-fulJv recessed -- outlet and 3 side inlet grille. plaster offset PFGB Plaster Front-fullv recessed-- outlet and 4 side inlet grille. 3/4" plaster offset 1.38 1.48 1.48 22.90 23 30 25 30 Note: Where more than 20rr of the convectors on a given order are m the No 4 depth, add $08 per sq. ft <EDR> to the Trade Price of the No. 4 depth unit only Standard Cabinets are furnished in: Prime painted sheet steel-reinforced. No 18 gauge front and No 20 gauge back, ends and top, rounded corners, streamline front discharge grille, and open bottom inlet arch, in heights, lengths and depths to accommodate convectors listed m cur rent literature For illustrations of cabinets, see page 42 For cabinet extras, see page 45 Ordering Example: 1 --F-458-20 Arco Convector Unit X-4 x i-'a For estimating shipping weights of Arco Convector Units use 1 \*i pounds per square foot for cabinet portion 3^ pounds per square foot for element portion ARCO CONVECTOR -- steam or water ELEMENTS ONLY (when sold less cabinets) convector length inches No. 4 33/.-' depth unit no. approx. shipping weight Trade Price No. 6 5%" depth unit no. approx. shipping weight Trade Price No. 8 7% - depth unit no. approx. shipping weight Trade Price No. 10 9`/2 " depth unit no. approx. shipping weight Trade Price 18 418 39 $12.41 618 57 $18.28 818 71 $23.02 1018 84 23 423 50 16.02 623 73 23.57 823 92 29 79 1023 110 28 428 61 19 62 628 90 28.90 828 113 36 57 1028 136 33 433 72 23 25 633 106 34.30 833 134 43.33 1033 162 38 438 83 26 86 638 123 39 62 838 155 49 99 1038 188 43 443 94 30.36 643 139 44.92 843 176 56.75 1043 213 48 448 105 33 95 648 146 50.22 848 197 63 53 1048 238 53 453 107 37.57 653 172 55.51 853 218 70 30 1053 264 58 4 58 128 41 19 658 189 60 82 858 239 77 07 1058 289 63 463 139 44 79 663 206 66 22 863 260 83.82 1063 314 CKflering fiampie 1 - - . c --:c C<2s: i/on Element only-No Cacmel X-4 1 : * 1: Arc.' C^r.\ L-cto; s .n lengths and depths indicated above are Standardized Sizes when sold with or without cabinets For s.zis r..-'. l.stcd abo\e-price on application $27 76 35 88 44 11 52.23 60 47 68 60 76 83 85 06 93 20 1C1 30 Page 41 7 Pncc L-si has boon prepared for the convenience of Ameucan-Standard distributors .ind ti.eir trade cu<- ' .in.* 7'ie trade prices shov*r. represent fixed m.i'Kups over distributor prices 10 refW .i c c s- evpcnbC .ire cc nui pjiport to rcp'cser.t d<.u.d. prues pre^Jiiint m an 01704 fAMERidAN-<Standard CONVECTORS .H.YDRONJC HEATING fi88fl^9sv^\ MULTIFIN CONVECTORS __jjt.._sg-.. B-l-g. The actual output In square feet of catalog rating--Steam <215*F.) obtained with the cabinet height! furnished determines the price of convectors and cabinets sold in combination. The total price of each order equals the amount of catalog square feet ordered multiplied by the price per square foot, plus the unit extra charge multiplied by the total number of units ordered. SEE CURRENT LITERATURE FOR STEAM AND HOT WATER RATINGS cabinet type description Trad* Pries sr unit litre oft chores Stock Model ____________________________________________________________ __________ K | Floor Type-free standing........................................................... | $0.40* | $11.10 Typo `Note: Price shown for estimating purposes only. For expanded prices, see page 44. For cabinet ______ extras, tee page 45. _______________ Special Service F Floor Type-free standing........................................................... $ .45 $13.00 FG Floor Type-free standing-inlet grille.................................... .48 13.00 W Wall Hung--flat top....................................................................... .44 13.00 FS Free Standing-sloping top......................................................... .43 FSG Free Standing-sloping top-inlet grille.................................. .46 S Wall Hung-sloping top............................................................... .40 13.75 13.75 13.00 TypoFS FR FRG FRGB Fully recessed-^," beveled edges............................................ Fully recessed-yu" beveled edges-inlet grille..................... Fully recessed-^," beveled edges-inlet grille with bottom overlap ......................................................................... .47 .50 .50 13.75 13.75 16.75 PR PRG PRGB Partially recessed-Vi". IVi", 2V4", 3", 5", 7" flanged edges Partially recessed--IVi", 2Vz, 3", 5", 7" flanged edges -inlet grille................................................................................ Partially recessed-H", 1%", 3", 5", 7" flanged edges --inlet grille--with bottom overlap........................................ .51 .54 .54 16.00 16.00 20.00 Typo W PFG PFGB Plaster Front-fully recessed--outlet and 3 side inlet grille. 44" plaster offset....................................................................... Plaster Front-fully recessed--outlet and 4 side inlet grille, 44" plaster offset....................................................................... .50 .50 14.50 16.50 Noto: Where more than 20% of the special service convectors on a given order are in the No. 4 depth, add $.08 per sq ft 'EDR) to the Trade Price of the No. 4 depth units only. Typo FR Typo Fit Noto: For cabinet extras, see page 45. For estimating purposes only, the following approximate shipping weights per sq ft may be used for Multifin convectors: Multifin stock model - 1.13 pounds. Also see page 44. Multifin cabinets (less element) - 1% pounds. Multifin cabinets (with element): Types F, FR. PR -Impounds. Types FS, W -1V4 pounds. Type S -Impounds. Ordirlnf Lunplst: Stock Model Multifin with an optional feature1 K-840-24 Multifin with Metal Trim Strips. Special Service Multifin with an optional feature: 1 PR-640-32-2V4 Flange. Multifin with Knob Damper. HH-* p,,. 42 This Price List ties been prepend for the convenience of Amencen-Stenderd distributors end their tree tomers only The trade prices shown represent fixed markups over distributor prices to reflect reaeonsb! snd distribution expense snd do not purport to npreoent actual prices prevalUng In any particular 01705 AMBRiCAN-<Standard hydronic heating MULTIFIN CONVECTORS- continued BATHROOM MULTIFIN CONVECTORS unit no. Type -rr {top outlet) sq. It output Typo "F" (front outlot) tq. ft. output Trade Prleo 416-13 420-13 424-13 5.3 4.6 $14.80 6.9 6.0 15.60 8.5 7.4 16.40 416-15 420-15 424-15 6.3 8.2 10.1 5.4 7.1 8.8 15.20 16.20 17.20 Note: Heights indicated are nominal. Actual height is 5" less. Knob damper available on 15' high front outlet grille ("BF") units only. For damper price see cabinet extras, page 45. OrderiRg Example: 0M16-15 Multifin Convector with Knob Damper. convectors convector length inch** 20 24 28 32 36 40 44 48 56 64 Elements only (when sold less cabinets) -- steam or wafer No. 4 depth No. 6 depth No. 8 depth No. 10 depth approx. unit shipping no. weight Trade Price unit no. approx. shipping weight Trad* Price unit no. approx. shipping weight Trade Price approx. unit shipping no. weight Trade Price 420 8 $ 8.60 620 13 $10.60 424 10 9.30 624 16 11.60 428 432 436 12 14 16 10.00 10.80 11.80 628 632 636 19 22 25 12.75 13.60 14.75 832 27 836 31 $17.00 18.40 1036 41 $22.75 440 444 448 456 464 18 20 22 26 30 12.60 13.55 14.25 15.85 17.60 640 644 648 656 664 28 31 34 40 46 15.85 17.00 18.20 20.20 22.60 840 848 856 864 35 43 51 59 19.85 1040 46 22.65 25.30 28.10 1048 1056 1064 56 66 76 24.50 27.85 31.05 34.80 Note: Elements only are furnished less floor supports. Multifin elements for special one-pipe steam header application--not available. Ordering Example: 1--420 Multifin Element only-no cabinet. Ratings: Ratings of Multifin Convectors have been determined in accordance with the method of testing and rating outlined in Commercial Standard Code CS140-47 and amendments and said ratings have been approved by the Convector Rating Committee. Standard Cabinets: Standard cabinets are furnished in prime painted sheet steel-reinforced. No. 18 gauge front and No 20 gauge back, ends and top. rounded comers, streamline front discharge grille, and open bottom inlet arch, in heights, lengths and depths to accommodate convectors as currentiy catalogued. 01706 Paga 43 Thta Price List haa been prepared for the convenience of. American-Standard distributor* and their trade cus tomer* only. The trade price* ahown represent fixed markups over distributor price* to reflect reasonable telling and distribution expense and do not purport to represent actual price* prevailing in tr CONVECTORS : AMEWCAN-iStandard HYDRONICHEATINQ 'MULTIFIN CONVECTORS TYPE K - STOCK MODEL - FREE STANDING Expanded prices For use on two-pipe steam and hot water systems only. Umi UV* totfaa No. 4 depth (4%* cabinet) wit n * Trad* --ip* vtifto Mm 20* cabinet height No. 6 depth (6*4* cabinet) No. 8 depth (8*4 ' cabinet) No. 10 depth (10*4* cabinet) wH n * Trad* m. VtfMt vviffct hie* wH m VtfMt Trad* Me* Nit M. m* ram Rfra*. ***** milfht Trad* Mtt 20 420-20 24 424-20 28 32 38 40 44 48 56 84 10.6 13.0 16 $15.34 620-20 14.9 21 $17.06 20 16.30 624-20 18 4 24 18.46 628-20 22.0 632-20 25.5 636-20 29.0 640-20 32.5 27 29 33 34 19.90 21.30 832-20 31.7 33 $23.78 -- 22.70 836-20 36.0 37 25.50 1036-20 45.5 42 $2930 24.10 840-20 40.4 39 27.26 1040-20 51.2 46 31.58 644-20 36.1 37 25.54 640-20 39.6 656-20 46.7 664-20 53.8 40 45 52 26.94 29.78 32.62 848-20 856-20 864-20 49.2 58.0 66.9 46 51 59 30.78 1040-20 34.30 1056-20 37.86 1064-20 623 73.4 84.5 52 58 64 36.02 4046 44.90 24* cabinet height 20 420-24 24 424-24 28 428-24 32 36 40 44 48 56 64 12.1 14.9 17.8 20 22 25 15.94 17.06 18.22 620-24 17.2 624-24 21.2 628-24 25.4 632-24 29.5 636-24 33.5 640-24 37.6 644-24 41.7 648-24 45.7 656-24 53-9 664-24 62.2 23 26 30 33 35 38 42 44 50 57 17.98 19.58 21.26 22.90 24.50 26.14 27.78 2938 32.66 35.98 832-24 836-24 840-24 848-24 856-24 864-24 35.6 40.5 45.5 55.4 653 753 38 40 44 50 55 63 2534 27.30 1036-24 2930 1040-24 49.0 55.2 45 52 33.26 37.18 41.22 1048-24 1056-24 1064-24 67.1 79.0 91.0 62 64 71 30.70 33.18 37.94 42.70 47.50 32* cabinet height 20 620-32 18.7 29 18.58 24 624-32 23.1 32 20.34 28 628-32 27.7 36 22.18 32 632-32 832-32 40.9 45 27.46 36 636-32 36.5 43 25.70 836-32 46.5 48 29.70 1036-32 53.1 54 33.10 40 640-32 41.0 48 27.50 840-32 52.2 56 31.98 1040-32 59.5 59 35.86 44 644-32 454 56 29.26 .... 48 648-32 49-6 5B 31.02 8*8-32 63.6 65 36.54 1048-32 72.3 69 41.22 56 656-32 58.7 67 34.58 856-32 74.9 73 41 06 1056-32 85.1 76 46.58 64 664-32 67.8 71 38.22 864-32 86.5 76 45.70 1064-32 97.9 84 51.98 Plugs and bushings are not regularly furnished with Multifin Convectors, but are available for separate sale at prices shown on page 37. .Note: For stock model cabinet extras, see page 45. Ordering Eiampli: l-K-636-32 Multifin. ft ft*4 Page *4 This Price list has been prepared for the convenience of Amencan-Standsrd distributors and their r tomer* only The trade prices shown represent fixed markups over distributor prices to reflect reasonat and distribution expense and do not purport to represent actual prices prevailing In any partlcuia. Ame rican'Standard HYDRONIC HE AT I NO CONVECTORS CABINET EXTRAS FOR MULTIFIN AND ARCO CONVECTORS CABINET EXTRAS-STOCK MODEL MULTIFIN ONIY Trade Price X. Knob operated damper............................................................................................ each $4.00 2. Metal trim (tripe 20" to 38' long................................................... ................................................each 40' to 64' long.............................................. '.................................................... each 3.05 3.55 3. Snap-on inlet grille..................................................................................................... each 2.80 *4. Air chamber with extended tube, manual vent..................................................each 3.50 5. Air chamber with Dole No. 20JRauto-vent.... ................................................ each Note: Itemi Also available (or special service multiAn. 3.50 SPECIAL SERVICE CABINET EXTRAS-MULTIFIN AND ARCO CONVECTORS Trade Price Trade Price 1. Knob Operated Dampers: (Standard Knob Type) For all types except Type "S"......................... each $4.00 For Type "S" only.............................................. each 4.20 Institutional damper (with Allen head (crew flush with cabinet) For all types except Type "S"......................... each 4.20 For Type "S" only.............................................. each 4.50 2. Access Doors (in standard locations 1, 2, 3, 4, 7 or 8 as shown in current literature) Hinged type with slotted head cam operator .............................................................. each Hinged type with Allen head cam operator ..............................................................each 4.00 4.80 Nett: Access doors in other than standard location price on application 3. Special tront fasteners (other than slotted head screws) Phillips or Allen head screws............per cabinet Cam locks for"F"and "FG" (Multifin and Arco) Cam locks for "S" and "W" (Multifin only) per cabinet Cam locks for "FR." "FRG," "FRGB" and "PR," "PRG," "PRGB"....................... per cabinet .35 7.20 9.60 4. Heavier gauge cabinets-Trade Price per sq. ft. of cabinet output: Front Only No. 18 gauge.......... ........ $ No. 16 gauge.......... .................04 No. 14 gauge.......... .................09 Unora Only $0.04 .06 .10 5. Insulation: (Furnished on outside of cabinet liner) Back, Ends Back Only and Top V4" Fibreglas. per cabinet $5.80 V4" Celotex.. per cabinet 5.80 $7.20 7.20 6. Special stiffening angles: Angle spotwelded inside cabinet front per stiffener 1.00 7. Metal trim strips: For recessing Types "F" and "FG" Multifin Convectors only Catalogued heights and lengths up to 36'. .each $3.05 Catalogued heights and lengths 40' to 64'. .each 3.55 Note: Any special height or length___ price on application 8. Sound deadening material (approximately Vi" thick) Inside front panel only.......................per cabinet Inside complete cabinet..................... per cabinet 5.80 7.20 9. Sealing strip tor standard length "FR," "FRG" and "FRGB" cabinets only (Vi" x 44" Polyeure- thane) ....................................................... per cabinet .10 Snap-on inlet grille............................................each For Types "F," "FS." "FR" and "PR" Multifin Convectors only. 2.00 2.80 11. End Pockets (provides additional length for valve housing-specify right or left hand) 4" end pocket with No. 18 gauge vertical baffle per end pocket 2.90 6" end pocket with No. 18 gauge vertical baffle per end pocket 3.60 8" end pocket with No. 18 gauge vertical baffle per end pocket 3.60 End Pockets over 8", use 8" end pocket price, plus 3.60 per inch or fraction thereof. .12 Multifin front panels only: 35% of complete convector unit price (based on No. 6 depth) 13. Arco front panels only: 20% of complete convector unit price (based on No. 6 depth) 14. Multifin Cabinet only: (no element) 70% of complete convector unit price 15. Arco Cabinet only: (no element) 50% of complete convector unit price 16. Knockouts: Are optional-Fumished only on request-Price on ap plication. MINIMUM CABINET HEIGHTS WITH DAMPERS Type cabinet F. FG W FS, FSG S FR FRG. FRGB PR PRG, PRGB BF Multifin 20" For all depths 20" For all depths 20" For all depths 20" For all depths 20" For all depths 20" For all depths 15" For depth Arco Cast Iron _ 24 "For all depths 01708 24" For all depths 24" For all depths 24" Fork4, #6, #8 depths-32" For J* 10 depth 20" For all depths 20" For all depths Not Available Cabinet heights shown for types W, S and BF are nominal heights, actual heights are 5" less. Cabinet heights for Arco Cast Iron convectors applicable. ;c X-4 (underneath) connections only. Page 45 Thle Price List has been prepared for the convenience of American-Standard distributors and their trade cus tomers only. The trade prices shown represent fixed markups over distributor prices to reflect reasonable eib,,e and distribution expense and do not purport to represent actual prices prevailing m a HH-4 TERMS American-Standard HYDRONIC HEATINQ TRADE PRICE BOOK IUustrations and descriptions of Plate Numbers listed in this price book will be found in the current AmericanStandard Hydronic Products Catalof ana literature. Items illustrated in product literature and not included in inis price book are discontinued. The illustrations In this price book although actual representations of certain product in the line, do not necessarily show sizes and details of all products in the line. This book contains suggested Trade Prices for certain Hydronic Heating products sold by American Radiator ti Standard Sanitary Corporation ("American-Standard") through its Plumbing and Heating Division. (AmericanStandard acting through that Division is hereinafter referred to as the "Seller"). The Seller assumes no obligation to sell to anyone at any price any of the items listed herein. This Price List has been prepared for the convenience of American-Standard distributors and their trade customers only. The trade prices shown represent fixed markups over distributor prices to reflect reasonable selling and distribu tion expense and do not purport to represent actual prices prevailing in any particular market AH prices herein set forth supersede all prior price lists and are subject to change without notice. The Seller may also, from time to time, discontinue without notice the sale of any of the products listed herein. r ^ INVOICE MINIMUM A'T*' fir An order for items included in this price book for which invoice prices aggregate less than $3.00 net will be billed at $3.00. TERMS AND CONDITIONS APPLYING TO ALL SALES OF GOODS BY AMERICAN-STANDARD THROUGH ITS PLUMBING AND HEATING DIVISION TO ITS DISTRIBUTORS All sales of goods by American-Standard through its Plumbing and Heating Division are made subject to terms and conditions printed below, in its bulletins and on its acknowledgment of order, invoice and quotation forms. These terms and conditions are as follows: PRICE Goods sold by the Seller will be billed to the Buyer according to the pnees end terms contained In its current bulletins and price booKs. In the case of orders for coods for which no pnee is currently in effect, the price will be determined by the Seller and set forth In the invoice issued after shipment of the goods. Taxes. Any tax or other Government charge now or hereafter levied upon the production, sale, use or shipment of goods ordered or sold, will be charged to and paid for by the Buyer. DELIVERY Traupertatiea Risks. Delivery to the Initial carrier shall constitute delivery to the Buyer. The Seller's responsibility ceases upon delivery in good order to such carrier, and all goods are shipped at the Buyer s risk. The Buyer is urged to examine all deliveries carefully before signing transportation receipts. If goods are visibly damaged, the Buyer should Insist that written confirmation of the damage be noted on the freight bUl or dray ticket by the agent ot the earner. If damage is discovered after unpacking, the carrier should be notified at once, so that inspection can be made and the claimed damage substantiated by the carrier. laterfcreare with Deliver*. The Seller has no obligation to deliver goods against any order until It has accepted the order by issuance of its acknowl edgment of order. Ln any event, the Seller will not be Uable for any delay or failure in the delivery or shipment of goods against an accepted order or for any damages suffered by reason thereof, when such delay or failure is. directly or indirectly, due to accident (in manufacture or otherwise i. Are. flood, not. war. emoargo. labor stoppages. Lnadequste transportation facilities, shortage of material or supplies, delay or default on the part of its vendors, regulation by Government authority, or any like or dissimilar cause or causes beyond its control. WARRANTY Except where a different expren written warranty has been Issued with retpeci to paxucular products, no warranty, express or implied, is extended by the Seller to any person or persons other than its distributors and other direct Buyers The Seller warrants only, and only to direct Buyers, that it will furnish by freight a replacement for, or at Its option repair, any product of it* manufacture or part or portion thereof, proved to Its satisfaction to be defective in material or workmanship under normal use and service within one year after installation. The Seller will not be responsible for sny damages whatsoever, or for labor expense, in connec tion with such replscement or repair. This warranty is in lieu of all other warranties, express or implied and of all other obligations or liabilities on the part of the Seller The Seller neither assumes nor authorises any other person to assume for it any othei liabilities in connection with the sale of its products except in the case cl express warranties which may be issued by it in writing from ume to time with respect to particular products Goods of other manufacturers sold by the Seller are not warranted except by express warranties which may be issued In wnting from Ume to time, with respect to particular products or parucuiar tales, but the Seller will endeavor to secure for Its direct Buyers the benefits of warranUes extended by the manufacturers of such goods sold but not man ufactured by the Seller. CONTRACT WITH RUYIR Acceptance af Orders. Orders will be accepted only by the Seller's usual acknowledgment of order containing terms and conditions applicable thereto. No terms and conditions appearing in a Buyer s order that are at variance with the Seller s terms and conditions shall be binding upon the Seller unless specifically agreed to by it in writing Unless the Seller spe cifically so agrees in writing In acknowledging any order, any terms and conditions appearing in a Buyer s order contrary to those stated herein nd in such acknowledgment of order are to be deemed waived by the Buyer. Receipt by the Buyer of the acknowledgment of order without prompt objection to the terms and conditions therein end herein set forth, consututes acceptance by the Buyer of such terms and conditions. Caaecllstioa of Orders. After the Seller's acknowledgment of order has been issued, an order may be modified or cancelled only upon written agreement by the Seller Orders for goods other than those of standard manufacture will not be cancelled after a commitment has been made or producuon scheduled. Credit for Returned Goods. Merchandise may not be returned for credit unleu the Seller has agreed to accept it. Where returns are accepted, a deduction of 10% will be made for rehandling All transportation costs for returned goods must be paid by the Buyer. In sny event, only salable merchandise ot standard manufacture may be returned for credit. Credit Approve!. Buyers' orders are accepted subject to credit investiga tion and approval, and delivery may be withheld or shipment stopped in transit on accepted orders without any liability on the Seller s part. if. in its opinion, the Buyer's ability to pay for the merchandise on these terms and conditions is in doubt. SHORTAGES OR VARIANCES No claims for variances from or shortages in orders will be consideied unleu presented within BO days after receipt of goods PRODUCT AND PACKAGING CHANGES Factors beyond the control of the Seller and the need for continuing improvement of product require the making of changes from time to time in products and their packaging The right is reserved to make reasonable changes of any kind without notice and to deliver revised designs or models of goods against any order, unleu on the face of the acknowledgment of order this right is specifically waived rne Seller shall have no responsibility whatever with respect to changes made by the manufacturer m products (or their packaging! sold but not rr.anuisctured by the Seller SHIPPING WEIOMTS The shipping weights given herein are approximate, for Buyers' con venience only, and are not guaranteed. HH-4 AMERICAN RADIATOR & STANDARD SANITARY CORPORATION PLUMBING AND HEATING DIVISION Page 46 AMERiCAN-<tanclard HYDRONIC PRODUCTS MEMORANDUM Pag* 47 HH-4 01710 HH4 ^American-Standard PLUMBING AND HEATING DIVISION AMERICAN RADIATOR & STANDARD SANITARY CORPORATION 40 WEST 40?n CmISET NEW YORK, N.Y. 10018 Litho in U.S.A. 01711