Document k4a046OxQG38Lk9yEN3L0gqD

ABD00088991 Names Me Allister Next test dues TSI MODEL 8015 PORTACOUNT FIT-TESTING SOFTWARE Version 2.01 S/N 927 VISTA POLYMERS FIT TEST REPORT Test dates Test time: Test subject last name: Test subject first names ID numbers Operator names Next fit test due: Test agent: Test device: 08-03-1994 7:17:32 am Me Allister Billy 427722276 H Pruitt Ambient particles TSI MODEL 8010 PORTACOUNT RESPIRATOR ID Size: Model: Manufacturer: Approval number: Smal 1 U1travue Facepiece MSA TC-19C-113 Additional notes: Additional notes: TEST DATA Ex. Ambient (Part/cc) Pass/Fail level: 100 Test cycles....: 1 Mask Fit Factor (Part/cc) Pass/Fail NB 22000 DB 24650 SS 25600 UD 25450 R 26400 NB 25950 0.310 1.230 0.290 0.540 1.750 0.360 71100 20000 88400 47200 15100 72100 PASS PASS PASS PASS PASS PASS OVERALL FIT FACTOR = 33964 (Calculated per ANSI Z88.2-1980) PASS Operator_-----__________________________________________ Date____ 9^ Test Subject 'fr/VnlLL