Document k1rm93Z7LrRpD39eOm553njJ
In-line Measurement of Electrical Properties ftp Hoeing Dielectrics
TOWOLDMONOQ30391
Introduction
Increasing quality demands on liquid dielectrics have necessitated improved re finement techniques and better methods of electrical property measurement. Recently, three-terminal electrical measurements with improved measuring sensitivity have been developed for laboratory measurements. However, factory needs went even further.
Here, the desire was to have a quick, repro ducible and reasonably accurate method of quality measurement. The equipment was to be rugged, mount directly on the pro
cess stream or be able to take off a small side stream, thereby eliminating the intri cate sampling and sample handling methods normally employed for laboratory analysis.
Another feature desired was a direct read out which would be simple for the operating personnel and lend itself easily to recording.
0 3 VJ L ^
TOWOLDMONOQ30392
Comparison Between the In-Line and Conventional Laboratory Measurements
The old two-terminal type measurement, a widely used laboratory standard in the past, has been recognized as inadequate to monitor the present high quality dielectrics. Improved 60Hz power factors produced have been beyond the measurement capability of this equipment. A more accurate three-ter minal (guarded) laboratory system has been proposed which will overcome some of the inadequacies of the old method. Even with the improved technique, the results are de
pendent upon the sampling conditions, the container and the actual test conditions. Any laboratory sample is usually not too repre
sentative of the entire lot. Since the in-line analyzer processes a flowing side stream, the
sampling difficulties are eliminated. Cell cleaning, a very important part of the
laboratory measurement, has not been dem onstrated necessary on the in-line system, provided some discretion is exercised in the selection of the material passed through the analyzer system. This makes screening of material faster and easier. The in-line analy zer is not a substitute for the laboratory guarded measurement. It is, however, much faster and generally more suitable (for pro cess monitoring) with reasonable accuracy. Compared to the two-electrode system, the in-line analyzer offers advantages by the elimination of lead cable effect and stray capacitance that give erroneous readings.
0353^20
TOWOLDMONOQ30393
Recommended Use of In-Line System Equipment
CELL| Basically, we use a three-electrode cell
which provides a guarded electrode and per
t mits highly accurate measurements because of the well defined area of the active elec trode. More important still, lead effects are
eliminated. The cell is highly polished 316
stainless steel using low conducting plastic
insulators to separate the electrodes. The
RECOMMENDED USE OF IN-LINE SYSTEM EQUIPMENT
electrodes serve structural as well as elec trical purposes.
The cell is designed to handle the dielectric
under dynamic conditions with the outer
electrode serving as part of the fluid housing.
The guarded center electrode is designed to
t promote stability and uniformity in the fluid flow as it approaches the measuring zone. The end plate, designed to provide a seal for
the cell, serves both as a connection to the
system piping and as a guard electrode. A
thermocouple is installed through the guard
The in-line analyzer system is recom mended for usage in monitoring the elec trical quality of askarels in process. Al though resistance (DC) measurements can be made with the proper equipment, the pre ferred measurement is 100Hz power factor. This can be easily equated with measure
flange to measure the temperature of the fluid as it enters the measuring zone.
The cell is a Monsanto design (MONS)*
specially built by Balsbaugh Laboratories in South Hingham, Massachusetts. The cell is designed for a total air capacitance of 75 picofarads.
ments at other frequencies by the simple relationship shown in the calculations. The
MONSANTO IN-LINE CELL
unit is designed to take the dielectric at
60C, heat it to a measurement temperature
of 100C and make the measurement under
flowing conditions. All this equipment is
housed in one compact unit.
EQUIPMENT} The in-line analyzer consists of three basic components (1) the cell, which is the heart of the entire operation, (2) a General Radio 1605AH Impedance Compar ator which is the detector and (3) a General Radio Type 1422CB Precision Capacitor used as the standard for comparison.
NOMENCLATURE
10. Outside electrode (low) 11. Inner electrode (high)
12. Teflon insulator 13. Lower guard and bottom 14. Teflon insulator 15. Upper guard and top 16. Electrode screw and center
contact
17. Teflon spacer 18. Viton (or Silicone) 0 Ring
seal 19. Viton (or Silicone) 0 ring
seal 21. Support bolts and guard
connection
22. Lower lock nut 23. Upper lock nut 24. Fluid inlet 25. Fluid outlet 26. Tluid outlet 27. Insert hole for
thermocouple 28. Inner electrode terminal
on GR 874 plug 29. Kel F insulator washer 30. Guard connector to GR 874
plug 31. Teflon insulator for Va"
tube X \'t" NPT pipe 32. Outside electrode terminal
03534,^1
TOWOLDMONOQ30394
Measuring Equipment
Test equipment used with the specially designed cell is a General Radio 1610 AH Impedance Comparator with a General Radio Type 1422CB Precision Capacitor for the dissipation factor measurements. (Note: Hue to the small error the dissipation factor is read directly as Power Factor. See rela tionship shown in the calculations.)
Measurements are made at 100Hz and 100 C. Since the GR1605AH is a comparator, a small correction for the power factor on the GR1422CB Precision Capacitor is nec essary for maximum precision, but in most cases it can be ignored. Also, being a com parator, higher power factors can be meas ured by simply adding resistance on the known side. Because the 1605AH is a trans former ratio arm bridge, and guarded (3 ter minal) measurements are made, the cable effect is eliminated. Therefore, knowing the air capacitance of the empty cell, it is pos sible to monitor the dielectric constant as well as the power factor. (See calculations)
Auxiliary Equipment
The GR1605AH Impedance Comparator is direct reading for power factor and capaci tance balance. However, a jack is provided at the rear of the instrument for recording. A 5 MV signal is supplied for driving the recorder. Most recorders are connected only to the power factor indicator for quality monitoring. One such recorder used on this system has been a Leeds and Northrup Model 15.
Another electrical quality measurement is the specific resistance or resistivity. By the use of a General Radio 1644A Megohm bridge, periodic resistance measurements can be made. These measurements do not lend themselves well for continuous quality sur veillance. However, since resistivity is re garded by many people as a measure of qual ity, it is desirable to be able to make such measurements for comparison.
For the 50Hz application, modifications must be made to the bridge components to eliminate harmonic problems causing beeps in the test results.
The component parts are mounted in an enclosed case which is nitrogen purged. The case contains a sample heater with sufficient control equipment to bring the material to the measurement temperature. Included is a temperature and flow indicator for adequate control. Process connections are provided at
the rear of the instrument along with the nitrogen purge connection. All power for the instrument is provided by the 110-120 VAC plug. The instrument is thoroughly grounded to the ground lead of the plug. Therefore, any auxiliary connection must be well
grounded. The instrument is connected to a bypass
side stream for process monitoring. The flow is set at 5 gph and the system is allowed to reach the operating temperature of 100'C as shown on the indicator. Once the system reaches temperature equilibrium and the liquid flushes the cell, the sensitivity of the instrument is adjusted until a reading can be made with the maximum sensitivity. The capacitance balance is made by adjusting the precision capacitor until a null is ob tained on the "Impedance Difference" meter.
Once the instrument reaches steady state operation, the power factor is indicated on the "Phase Angle Difference" meter and re corded if an auxiliary recorder is attached. As the power factor improves and the read ing lowers, the sensitivity should be in creased for maximum accuracy.
The instrument can be started or stopped by merely closing off the flow. There are automatic cut-offs in the bridge to prevent damaging the instruments on overrides. The temperature control has a built-in system to prevent thermal degradation of the di electric, so when the flow undergoes major upsets, steady state temperature control will not be regained immediately. Flow rates ex ceeding the meter range may result in er roneous readings.
DISCUSSION OF MEASUREMENT
As previously discussed, the in-line meas urements are guarded. To maintain the guard and keep the flow-through characteristics, teflon connectors are used on the inlet and outlet of the cell. The fluid is heated slightly above 100C by an electrical heat exchanger, which controls the watt density heating the
TOWOLDMONOQ30395
sample. The fluid temperature is measured directly before it enters between the measur ing electrodes.
The system is also designed for streamline flow between the electrodes. All eddies or pockets are eliminated in order to obtain a steady reading. Once the electrical measure-
ment is made, the sample is returned to the process. All handling of the fluid is in a
closed system to eliminate contamination. With the other precautions built into the in-line system, an accurate reproducible elec trical quality measurement can be made.
Calibration of the In-Line System Against Present Standard
To arrive at a smooth transition between the present standard (regardless of elec trode configuration or test equipment), the presently used standard must be calibrated against the in-line readings. One such com parison between the conventional two-elec trode system and the in-line anlyzer is shown in the graph (based on resistivity).
IN-LINE POWER FACTOR vs CONVENTIONAL RESISTIVITY.
IN-LINE 100Hz PF
----------------- xlO'1 ohm CM CONVENTIONAL RESISTIVITY using concentric cylinder cell
0353423
TOWOLDMONOQ30396
Theoretical Relationship In Electrical Measurements
Relationship Between Power Factor (PF) and Dissipation Factor (D)
J'F =
Since D is amall, PF = D
Determination of Resistivity (P)
Rv == volume resistance, in ohms, measured on GR 1644 Megohm bridge
A _ Ca I'
``ace relationship between capacitance C and surfacegap of cell A_
t
A _ 75 x 10''! farads
(Rased on actual measurement of Ca for each cell)
t 8.85 x fO'1' (coulomb)11/Newton M"
-~ = 8.45 M or 845 cm
Theoretical Relationship for Power Factor (PF) and Resistivity (P)
PF -------,,
Rr Cp
Ri* = Rv = volume resistance
where Rv = P/A/,
Ci* -- parallel capacitance w = (sinusoidal wave shape assumed)
= 2irf
where / = cycles per second
PF = U R* Cs Rs = series resistance C8 = series capacitance
Relationship Between Capacitance (C) and Surface-gap of Cell (A)
.. k.. ' t Ca = air ca]iacilnncc
m
Ko -- permilivity of free space or vacuum 8.854 x 10'11! coulombs2/ (Newton) (M)J
A = average area between the electrodes
t = space between the electrodes
Determination of Dielectric Constant (K)
C, = capacitance of sample Ca = capacitance of air
Frequency Correction for PF
PF,=
PF,,,
PF,,, -- measured power factor fm = measuring frequency f, = desired frequency for measurement
Comparison Between Physical Measurements and Calculation from the Electrical Measurements
Physical Measurement ^ = B35 cm
Calculation See Determination of Resistivity A _ Ca T " "Eo'"
= 8.45 M or 845 cm
0 35 3S S
TOWOLDMONOQ30397
The information contained in this bulletin is, to our best knowledge, true and accurate, but all recommendations or suggestions are made without guarantee, since the conditions of use are beyond our control. The Monsanto Company disclaims any liability incurred in connection with the use of these data or suggestions. Furthermore nothing con tained herein shall be construed as a recommendation to use any prod uct in conflict with existing patents covering any material or its use.
Monsanto
Monsanto Company / Functional Fluids / 800 North Lindbergh Blvd. / St. Louis, Missouri 63166
1068 ICI-LRA LITHOII'
03534^5
TOWOLDMONOQ30398