REV. mi S4T Pag* 4 MEASUREMENT AND CONTROL OF ASIESTOS DUST EXPOSURE AHHl 1973 * Wt Paga Rav May 1974 114 7.3 Procedure 7J. 1 Flow through die pump should be calibrated, with the filler in Hoe for each puaip. ' 7JJ dip filter holder to lapel or shirt pocket as dose as possible to the person's nose and mouth. Filer should he borisontal or slightly down, never facing up. This is sometimes referred to as personnel sampling and is preferred. 7J.3 At times it may be advantageous to collect samples from a fixed location representative of a more general work area. This is sometimes referred to as environmental sampling. In such cases, the filter should be located as dose as possible to the person's breathing zone at the job or in the area being monitored. The type of sampling should be chosen to determine most accu rately the employees' exposure. 7.3.4 kamova lop saction of lha filter to expose the hid filter face. 7.3.5 Turn on pump and set at approximately two (2) liters per minute rate (1 -- 2.5 1pm range). Esti mate sampling time (X) in minutes as follows (15 minute minimum): pump rate (1pm) x expected fiber count Assume a fiber count of 2 per cubic centimeter for first test if no better information is available. (This equation optimizes ease and accuracy of the fiber count) Record actual pump rate periodically. When finished sampling, turn off pump and record elapsed sampling time. Typical sampling record forms, EN--2731 (see Figure 3) are available from Stationery Stores, Engineering Depart ment Wilmington, Delaware. 7.3.6 Replace filter top after sample is collected and seal with tape prior to shipment Stoppers furnished with filter units must be replaced before sealing. 7.4 Analysis. Completed samples (exposed filters) are placed in a mailing tube, sealed, and sent to a qualified laboratory with two copies of the sampling record. 7.4.1 It is recommended that an unexposed filter be included with each batch of samples for reference. 7.4.2 All determinations shall be made by the mem brane filter method at 400--450X(magnification) (4mm objective) with phase contrast illumination. 7.4.3 Qualified Laboratories G. W. Hiddemen E. I. du Pont de Nemours & Co Marshall Laboratory 3500 Grays Ferry Avenue Philadelphia, PA 19146 PLAINTIFF'S EXHIBIT DUP-1604 Morton Corn, Ph D Attention: Felix Stein Graduate School of Public Health University of Pittsburgh Pittsburgh, PA 15213 W. A. Burgess 38 Fox Hill Street Westwood, MA 02090 5 7.5 Rocord Keeping. Records of personnel and environ mental monitoring shall be maintained for three (3) years and made available upon the request of authorized representatives of OSHA and NIOSH (National Institute of Occupational Safety and Health). 7.6 Caution Signs and Labels 7.6.1 Caution signs conforming to Figure 1 shall be posted at all approaches to areas where asbestos concentrations may be above permissible exposure limits. They shall be placed at a sufficient distance to permit an employee to read the signs and take necessary precautions before entering the area. 7.6.2 Caution labels conforming to Figure 2 shall be used to identify containers of raw materials, scrap, waste, other products containing asbestos, and asbestos contaminated clothing. Portions printed in rod moot OSHA requirements. Section 1910.93a. DU 062120 DUP 1153893