Document jyz1qwXjBGN5gD4m7nJBBVQQk

472________ CHAPTER 25 1946 Guide Table 3.. Correction Factors for Direct Cast-Iron Radiators and Convectors8 &TEAM Pssaa. Heating Medium Factors fob Direct Cart-Iron Radiators Factors fob Convectors Approx. . Temp F Gage Aba. Steam Room Temperature F Inlet Am Temperature F Vacuum Lb per OB Id. Hg. Sqln. Water 80 75 70 65 60 55 50 80 75 70 65 60' 55 50 22.4 ' 3.7 20-3 4.7 17.7 6.0 14.6 7.5 10.9 9.3 6J 11.5 LbperSqlo. 1 15.6 6 21 15 30 27 42 - 52 .67 150 2_58 236 117 2.00 1.86 1.73 1.62 3.14 2JJ3 2.57 2.35 115 1.98 1,84 160 2.17 2.00 1.86 1.73 1.62 1.52 1.44 2.57 235 2.15 1.98 1.84 1.71 L59 170 1.86 1.73 1.62 1.52 1.44 IJ5 1.28 2.15 L98 1.84 L71 1.59 1.49 1.40 180 L62 1.52 1.44 1.35 1.28 1.21 1.15 1.84 1.71 1.59 1.49 1.40 1.32 1.24 190 1.44 U5 1.28 1.21 1.15 1.10 1.05 1.59 1.49 1.40 U2 1.24 1.17 1.11 200 1.28 1.21 1.15 1.10 1.05 1.00 0.96 1.40 U2 1.24 1.17 1.11 1.05 1.00 215 1.10 1.05 1.00 0.96 0.92 0.88 0.85 1.17 1.11 1.05 1.00 0.95. 0.91 0.87 230 0.96 0.92 0.88 0.85 0.81 0.78 0.76 1.00 0.95 0.91 0.87 0.83 0.79 0.76 250 0.81 0.78 0.76 0.73 0.70 0.68 0.66 0.83 0.79 0.76 0.73 0.70 0.68 0.65 270 0.70 0.68 0.66 0.64 0.62 0.60 0.58 0.70 0.68 0.65 0.63 0.60 0.58 0.56 300 0.58 (IST 0.55 0.53 0.52 0.51 0.49 0.56 0.54- 0.53 0.51 0.49 0.48 0.47 "To determine the size of a radiator or a convector for a given space, divide the heat loss in Btu per hour by 240 and multiply the result by the proper factor from the above table. To determine the heating capacity of a radiator or a convector under conditions other than the basic ones with the heating medium at a temperature of 215 F, and the room temperature at 70 F In the case of a radiator, and the inlet air temperature at 65 F in the case of a convector, divide.the heating capacities at the basic conditions by the proper factor from the above table. rating-test conditions' to output under other operating conditions. Such . factors are.given in Table 3. When it is desired to change the output under any test conditions to the corresponding output under standard Code test conditions, the reciprocal form of correction factor may be derived.- The equations for steam units are: For radiators: /215 - '70V Ca V t, - <r / For convectors: /215 - 65\l-5 (1) \ -}i ) (2) The output under standard conditions will be: H, = C, Ht where . C, = correction factor. f, = steam temperature during test, Fahrenheit degrees. Ir = room temperature during test, Fahrenheit degrees. <i = inlet air temperature during test, Fahrenheit degrees. H$ = heat emission rating under standard conditions, Btu per hour: Ht = heat output under test conditions, Btu per hour. (3) The relation between the size of the radiator or convector and the size of the test room will affect the results obtained in a capacity-rating test.4 The height and location of the radiator and the insulation of the test room are other important factors that are not specifically regulated by the Code. For a radiator, the finish coat of paint affects the heat output. Oil paints of any color will give about the same results as unpainted black or rusty surfaces, but an aluminum or a bronze paint will reduce the heat emitted by radiation. The net effect may be a reduction of 10 per cent or more in the total heat output of the radiator M,T. : Radiator enclosures and convector casings affect the heat distribution within, the.room.as well.as the total amount of heat supplied by the steam or hot water8. ' Radiators and Convectors 473 Heating Effect For several years the term heating effect has been used to designate the relation between the useful output of a radiator, in the comfort zone of a room, and the total input as measured by steam condensation or water temperatures *10. The application of such a heating effect factor is a recog nition that some radiators and convectors use. less steam than others forproducing equal comfort heating results in the room. No standard method for evaluating the heating effect of radiators and convectors and correlating it with comfort has yet been accepted. One method, with test data11 on radiators and convectors, and making use of the eupatheoscope for evaluating the environment produced, has been suggested by the University of Illinois. The principle underlying the eupatheoscope involves the measurement of the heat loss from a sizable. 1111111 ii 111 muCold room temp in dee F 11 | 1 J..IU. I' ,, /,!, i, r -i .Jill 5.60 b convector No. 1 5.84 lb convector No. 22 6.12 lb convector No. 6 6.32 ib 5-tube radiator Temperature in deg F Position No. 3 Position No. 1 30" level Eouiv Gift 30* level Equiv Oitt 67.7 662 *1.5 67.4 65.9 *1.5 68.2 643 3.9 680 66.6 1.4 68.0 65.1 2.9 67.9 67.9 0.0 682 66.4 *18 56 HEIGHT ABOVE FLOOR IN FEET Fig. 2. Temperature Gradients and Equivalent Temperatures for Radiator and Convectors with Common 30 in. Level Temperature body by radiation and convection, when the surface is maintained at some constant temperature. Through the use of this instrument and its calibration curve, non-uniform environments may be referred to uniform environments in which the air and all surrounding surfaces are at the same temperature. The temperatures of the uniform environments are referred to as equivalent temperatures. The Kata thermometer1J, the thermo-integrator 13,11, and the globe15 thermometer are other instruments which have been used to measure the influence of air temperature, air movement and radiation in an environment. Data given in Fig. 2 show that while the air temperature at the 30-in. level is the same for the three convectors and the one large-tube cast-iron. radiator, in position No. 3 in the test room, the equivalent temperature is 1.5 F lower than the air temperature in the case of the three convectors, and . the same as the air temperature in the case of the radiator. The difference between the minimum and the maximum amount of heat