Document jyq7xvKd0EGLMNyaNJpbQJ16Q
ABD00313347
ABERDEEN CHEMICAL PLANT INDUSTRIAL HYGIENE MONTHLY REPORT
Month: September Date of Report: 10/25/84
Routine Chemical Dosimetry
All Sample Results: Chemical
<_______ PEL
No. %
^_______ PEL Overexposures No. %
VCM Lead Total Particulates
86 95.6 8 . 80 5 100
4 2 0
4.4 20
0
Overexposures
Job Class
Exposure
Source
Lead Operator
2.2**ppm, VCM
Employee overexposed while working in the vicinity of a VCM filter pak filter change in the new unit.
General Mechanic
1.5**ppm, VCM
Employee overexposed while changing 743 reactor chem wash sprayhead.
rard Operator
1.3*ppra, VCM
Employee overexposed while hooking/unhooking VCM railcars at the VCM tank farm.
.Yard Operator
1.3*ppra, VCM
Employee overexposed while hooking/unhooking VCM railcars at the VCM tank farm.
Color Weigh Compounder
68.8* mic^ogram Lead/m
Employee overexposed while doing his routine job of color weigh-up. No specific cause for the overexposure has been identified. The two lead materials handled were Epistatic 112 and Cyastab 988.
Line I Compounder
139.1* mi^rogram Lead/m
Employee overexposed while charging Epistatic 112 into blends of 34431 Natural on Line I.
* Respiratory protection was worn. ** Respiratory protection was not worn.