Document jypVmJqj0OXXGbdzQ2wbGvZG2
Monsanto
FROM (NAME ft LOCATION)
DATE
:
SUBJECT
:
REFERENCE
TO
A. L. Rasmussen - WGK September 15* 1971 Foaming of Waste Aroclor Incinerator.
W. C. Engman
CC: A. E. Leisy E. E. Stewart R. M. MeCutchan D. K. Lynch
Yesterday* I had planned to run some defoamer experiments using our waste aroclor. However* I could not get the original waste to foam.
Two trials were made:
#1 - Some 200 ml of waste from 117 storage was heated in an open beaker without agitation. The temperature was raised from 30C to 140 C over a 1 hour period.
Some minor bubbling and vapor escape was observed. There was no hint of foaming. The sample originally contained 0.14$ water; after heating the water content was reduced to 0.021$.
#2 - To some 200 ml of the 117 waste* 1 ml of water was added to bring the percentage to 0.6$. Free water was observed. The sample was heated fcpen beaker - no agitation) from 26 C to 135 C over a 30 minute period. Some vapor escape was noted* but no foaming. At this point* the hot solution was stirred; some minor "coffee" type foam resulted.
I am now requesting PR&D to pursue this effort further to
determine the magnitude of the problem and the effect of
defoamers.
-
A. L. Rasmussen Mfg. Rep. ap
oSVN 295415
STLCOPCB4065518