Document jyn6rvJ36bXxbKOpXqpX9zLr2

DATE: SUBJECT: FROM: THRU: TO: UNITED STATES ENVIRONMENTAL PROTECTION AGENCY REGIONS 77 WEST JACKSON BOULEVARD CHICAGO, ILLINOIS 60604 OCT 2- 5 2018 CLEAN AIR ACT INSPECTION REPORT Zenith Energy Terminals, Cleveland, Ohio Luke Hullinger, Environmental Engineer AECAB (MI/WI) Sarah Marshall, Section Chief AECAB (Ml/WI) File BASIC INFORMATION Facility Name: Zenith Energy Terminals Facility Location: 250 Mahoning Ave, Cleveland, Ohio Date of Inspection: 8/29/2018 EPA Inspector(s): I. Luke Hullinger, Environmental Engineer 2. Kenneth Ruffatto, Environmental Engineer Other Attendees 1. Torn Gaal, Tem1inal Manager, Zenith Energy Terminals Contact Email Address: tom.gaal@zenithterminals.com Purpose of Inspection: Tanks inspection Facility Type: Bulk Storage Terminal Regulations Central to Inspection: 40 C.F.R. Part 60 Subpart Kb and 40 C.F.R. Part 63 Subpart BBBBBB Arrival Time: 9:00 AM Dep~rture Time: 10:45 Al\-1 Inspection Type: 12:1 Unannounced Inspection D Announced Inspection OPENING CONFERENCE 12:1 Credentials Presented 12:1 CBI warning to facility provided The following information was obtained verbally from Tom Gaal unless otherwise noted. Process Description: Zenith Energy is a storage terminal in Cleveland, Ohio. Zenith Energy stores petroleum products that are loaded and unloaded by truck and barge. All the bulk storage tanks have capacities over l 0,000 bbls, and either have fixed moves or internal floating roofs. Petroleum products stored at the facility include ultra-low sulfur diesel, glycerin, methanol, bio feed stock, and transmix. Staff Interview: Some of the tanks including the methanol tank at the facility are leased to another company. TOUR INFORMATION EPA toured the facility: Yes Photos and/or Videos: were taken during the inspection. FLIR camera videos - Appendix A Rim vents on bulk storage tanks were found leaking. A conservation vent was also found leaking on the methanol tank. RECORDS REVIEW l. Facility map - copy received 2. Zenith Energy Cleveland Tank Database - copy received CLOSING CONFERENCE Concerns: EPA noted the numerous leaking rim vents at the facility. SIGNATURES /)) (' Report A u t h o r ~ : ~ Date: Section Chief:= - = - ~ ~ ~ - - - - - - - - - - Date: Page 2 of3 Facility Name: Zenith Energy Terminals Facility Location: 250 Mahoning Ave, Cleveland, Ohio Date of Inspection: 8/29/2018 APPENDICES AND ATTACHMENTS I. Appendix A - Video log Page 3 of3 Facility Name: Zenith Energy Terminals Facility Location: 250 Mahoning Ave, Cleveland, Ohio Date of Inspection: 8/29/2018 APPENDIX A: DIGITAL IMAGE LOG 1. Inspector Name: Luke Hullinger 3. Company/Facility Name: Zenith Energy Terminals 5. Number of Images: 13 2. Date(s) of Inspection: 8/29/2018 4. Street Address, City, State: 250 Mahoning Ave, Cleveland, Ohio 6. Archival Record Location: C:\Users\Lhulling\OneDrive - Environmental Protection Agency _(EPA)\Zenith Energy Terminals Image Number 1 2 3 4 5 6 7 8 9 10 11 12 13 File Name MOV 2010.mp4 MOV 2042.mp4 MOV 2011.mp4 MOV 2012.mp4 MOV 2013.mp4 MOV 2014.mp4 MOV 2015.mp4 MOV 2016.mp4 MOV 2017.mp4 MOV 2019.mp4 MOV 2043.mp4 MOV 2020.mp4 MOV 2021.mp4 Description of Image Leaking rim vent on Tank 7 Leaking rim vent on Tank 7 Leaking rim vent on Tank 3 Leaking rim vent on Tank 122 Leaking rim vent on Tank 122 Leaking rim vent on Tank 122 Leaking rim vent on Tank 121 Leaking rim vent on Tank 120 Leaking rim vent on Tank 120 Leaking rim vent on Tank 125 Leaking rim vent on Tank 125 Leaking rim vent on Tank 124 Leaking conservation vent 190 Appendices Page 1 of 1