HCN COMPLEX INTERNAL PROCEDURE TOR CONTROL OF BYPASSING AND TESTING PROTECTIVE DEVICES POLICY No protective devices will be Intentionally bypassed or made Inoperative with out: 1. Providing adequate alternate protection to the system that the device protects. 2. Continuing communications that the devise is bypassed. 3. The approval of the appropriate level of authority. PROCEDURE In the event that a protective device mist be taken oat of service, it will be the responsibility of the chief operator to: 1. Give or acquire the appropriate approval to remove the protective device from service. 2. Define and Implement alternate means of protection normally provided by the device before the device is removed from service. 3. See that the alternate means of protection Is maintained until the device bypassed is returned to service. A. Place a control tag on the bypass device status board in the control room with all the information regarding the device bypassed filled in. COMMUNICATION The chief operator will check the bypass device status board at the beginning of each shift. Those devices requiring maintenance will be expedited. -1- SC 004020 LAM005229 Protective Device Level of Approval Required to Bypass Device Requirements for Bypassing & ______ Testing Frequency Safety Shower Alarms Chief Operator Foreman Specialist Gen. Superintendent Control tag required Alternate adequate protection must be provided (Test Frequency - 1/day) HCN Detector Chief Operator Foreman ..Specialist Control tag required Operator stationed at HCN storage tanks monitoring operations . (Test Frequency - 1/week) HCN Alarms Chief Operator Foreman Specialist Superintendent Control tag required Alternate adequate protection required .. (Test Frequency - 1/week) Backflow Preventers Chief Operator Foreman Specialist Control tag required Operator monitoring pressures with capability of closing valve if required (Test Frequency - 1/quarter) Closing Block Valves Under Relief Valves Chief Operator Foreman Specialist Control tag required Alternate adequate protection must be provided (Test Frequency - car seal check list reviewed 1/week) CT-2 Turbine Electronic Overspeed Trips .Chief Operator Foreman Control tag required Turbine speed set with manual tachometer--mechanical overspeed trip as backup (Test Frequency - 2/year) CT-2 Fan Vibration Trips Chief Operator Foreman > Control tag required Alternate adequate protection must be provided (Test Frequency - 2/year) 004021 -2- LAM005230 Protective Device Level of Approval Required to Bypass Device Requirements for Bypassing & Testing Frequency 27R1 Low Temp. S/D. Chief Operator .Foreman Specialist 27R1 Low HCN Flow Low AcH Flow HCN/AcH Ratio Deviation 27TAH 508 for 27T1 Chief Operator . (for startup) Chief Operator Foreman Specialist (For testing or bypassing) Chief Operator Foreman .Specialist High HCN Level in 25N2's Shuts off HCN Feed Chief Operator Foreman Specialist High Level in 25N2's Shuts off IBY Flow Chief Operator Foreman . Specialist Low Level In Premia Tanks (25N2's) Closes Reactor Feed Valves Chief Operator Foreman Specialist Low Reactor Temp. Closes TBA Reactor Feed Valve Chief Operator Foreman Specialist Control tag required Alternate adequate protection must be provided (Test Frequency - 1/quarter) Nothing for startup Control tag required for testing along with operator . monitoring (Testing Frequency -- 1/quarter) Control tag required for test ing along with operator monitoring . (Testing Frequency - 1/quarter) Control tag required Adequate alternate protection provided (Test Frequency -- 1/quarter) Control tag required Adequate alternate protection provided (Test Frequency - 1/quarter) Control tag required Adequate alternate protection provided (Test Frequency - 1/quarter) Control tag required Adequate alternative protection provided (Test Frequency - 1/quarter) -3- sc 004022 lAM005231 Protective Device Level of Approval Required to Bypass Device Requirements for Bypassing & ______ Testing Frequency High Reactor Temp. Closes TBA Reactor Feed Valve TBA Reactor and Hydrolyzer Tenor Step Advance TBA Premix Tank out of Tolerance Override (clear) ACT Generator Shutdown Interlocks . Low IRIK Flow Low HCN Flow Low DMK/HCN Ratio High Temp. . .Low Caustic Flow . Low Circulation Low Agitator Amps Dilute Filter Inter locks for High D/P (3) High D/P on 29D201 High D/P on 29D202 Chief Operator 25 lbs) Chief Operator (>25 lbs) Chief Operator Foreman For Startup Chief Operator Any period longer than startup Chief Operator Foreman Specialist Bypassing this Interlock is not permitted (Test Frequency - 1/quarter) Reactor or hydrolyzer con ditions verified in the field Chief notes problem in dally log Premix tank level verified .. Plan made lor high HCN in hydrolyzer bottoms Problem noted in daily log Nothing for startup Control tag required . .Adequate alternate protection provided (Test Frequency - 1/month) 1 shift Chief Operator >1 shift Chief Operator Foreman Chief Operator Foreman Specialist Chief Operator Foreman Specialist Control tag required Alternate adequate protection provided (Test Frequency - 1/quarter) Control tag required Adequate alternate protection provided (Test Frequency - 1/quarter) Control tag required Adequate alternate protection provided (Test Frequency -- 1/quarter) 004023 L/\M005232 Protective Device High Level Alarms in ACY and DMK Storage Tanks High Pressure 29D203 Low Temp. 29D203 Low Pressure PS247 Low Pressure PS229 Instrument Alarm Cards that are not Critical and have Downstream Alarms HCN Tanks High Level Alarms HCN Tank High Temp. Alarms Chlorine Tank Relief Valve Alarms Breathing Air Low Pressure Alarm SC 004024 Level of Approval Required to Bypass Device Requirements for Bypassing & ______ Testing Frequency Chief Operator Foreman Specialist Chief Operator Foreman Chief Operator .Foreman Chief Operator -for. Purging Any bther Foreman Specialist Chief Operator Chief Operator Foreman Specialist Chief Operator Foreman Chief Operator Foreman Specialist Chief Operator Foreman Specialist -5- Control tag required Adequate alternate protection provided ( Test Frequency - 1/year) Control tag required Adequate alternate protection provided (Test Frequency - 1/quarter) Control tag required Adequate alternate protection provided (Test Frequency - 1/quarter) Control tag required -Adequate alternate protection provided (Test Frequency - 1/quarter) Control tag required Alternate problem identification system noted on tag Annunciator labeled "Pulled" Control tag required Adequate alternate protection provided (Test Frequency 1/month) Control tag required _ Adequate alternative protection provided (Test Frequency - 1/quarter) Should not be bypassed Work to completion if mal functioning Control tag required (Test Frequency - 1/week) Control tag required Adequate alternate protection provided (Test Free. r.cv ^ 1/quarter) LAM005233