Document jyLMpxdXNyJXmDmowqbR8wVq9

SC-ELEC-02410 INDEX BY ROCKBESTOS TABLE LETTER 300 VOLT Ali-Asbestos RANGE and APPLIANCE LEAD WIRES MOISTEMP 125C (257CF) Motstvr*, Hot jnd Flam* Resitting Compound COPPER MONEL NICKEL A AM AN R RM RN Stove Wire (Solid)--Underwriters' Approved Stove Wire (Stranded)--Underwriters' Approved WBC WBCF WBCS WBM WBN WBMF WBNF WBMS WBNS 30 Mil Appliance Wire (Solid) 30 Mil Appliance Wire (Flexible Stranded) 30 Mil Appliance Wire (Coarse Stranded) WCC WCCF wees WCM WCN WCMF WCNF WCMS WCNS 40 Mil Appliance Wire (Solid) 40 Mil Appliance Wire (Flexible Stranded) 40 Mil Appliance Wire (Coarse Stranded) WDC WDCF WDCS WDM WDN Vt'DMF WDNF WDMS WDNS 30 Mil Appliance Wire (Tripled - Solid) 30 Mil Appliance Wire (Tripled - Flex. Str.) 30 Mil Appliance Wire (Tripled - Coarse Str.) WEC WECF WECS WEM WEN WEMF WENF WEMS WENS 40 Mil Appliance Wire (Tripled Solid) 40 Mil Appliance Wire (Tripled - Flex. Str.) 40 Mil Appliance Wire (Tripled - Coarse Str.) WSC WSCF -- -- -- -- Asbestos Insulated Wire (Solid) Asbestos Insulated Wire (Flex. Str.) WFC WFCF WFCS WFM wfmf WFMS WFN WFNF WFNS 33 Mil Hi-Dielectric Range Wire (Solid) 33 Mil Hi-Dielectric Range Wire (Flex. Str.) 33 Mil Hi-Dielectric Range Wire (Coarse Str.) WGC WGM WGN WGCF WGMF WGNF WGCS WGMS WGNS 43 Mil Hi-Dielectric Range Wire (Solid) 43 Mil Hi-Dielectric Range Wire (Flex. Str.) 43 Mil Hi-Dielectric Range Wire (Coarse Str.) Grounding Wire HI-TEMP 200C (392F) Heo and Flam* Resisting Compound COPPER MONEL N1CKEI A-300 AM-300 AN-300 R-300 RM-300 RN-300 XBC XBCF XBCS XBM XBMF XBMS XBN XBNF XBNS XCC XCCF XCCS XCM XCMF XCMS XCN XCNF XCNS XDC XDCF XDCS XDM XDMF XDMS XDN XDNF XDNS XEC XECF XECS XEM XEMF XEMS XEN XENF XENS XSC XSCF -- -- -- -- XFC XFCF XFCS XFM XFMF XFMS XFN XFNF XFNS XGC XGCF XGCS XGM XGMF XGMS XGN XGNF XGNS XI Pag* 14 14 8 8 8 9 9 9 10 10 10 10 10 10 11 11 12 12 M 12 13 1 13 7 300 VOLT Asbestos and Glass APPLIANCE LEAD WIRE Table AG Appliance Lead Wire (Glass Braided) 1000 VOLT APPLIANCE LEAD WIRE (Underwriters' Approved) Table FE Table FG Appliance and Range Wire (No Braid) Appliance and Range Wire (Glass Braid) GENERAL INFORMATION Standard Specifications for Rockbestos Range and Appliance Lead Wires Current-Carrying Capacities and Correction Factors District Sales Offices All Data Subject to change without notice. 15 16 2-6 7 Back Cover Catalog No. AW-35 (Rev. 58) Copyright 1935--5M Rockbestos Products Corporation ROCKBESTOS PRODUCTS CORPORATION Main Office and Works Nicoll and Canner Streets New Haven 4, Conn. printed in u. s. a. RBB 0053b THE QUESTION OF UNDERWRITERS' APPROVED APPLIANCE AND LEAD WIRES Underwriters' Laboratories are primarily concerned with the fire and accident features of equipment, materials, devices and appliances. Their approvals and listings are given after exhaustive tests have been run by them on completed appliances or assemblies, judged solely on their safe performance as a unit. Underwriters' have not at the present time established standards for asbestos insulated wires to be used as internal wiring of appliances and devices. While they have made provisions to accept and test for approval some special insulated electrical conductors for specific appliance applica tions (for example the wires listed on pages 14, 15, and 16 in this Catalog) their approval of asbestos insulated lead wire is based on its applica tion to a completed appliance or assembly which they will approve as a unit. Rockbestos has for more than thirty-five years manufactured asbestos insulated lead and appliance wires for all types of electrical appliances and devices. Underwriters' Laboratories through the years have approved many manufacturers' electrical appliances wired with the Rockbestos stand ard constructions listed in this catalog. Since the Underwriters' Laboratories Approval of an appliance is granted on the complete appliance and not on the component parts indi vidually, it must be clearly understood that because there are no Under writers' Standards for these types of wires, they cannot be Underwriters' Labeled. The recommendations for appliance wires that we make in this catalog are based on our tong time experience that these constructions properly applied will successfully meet the requirements of the Under writers' Laboratories. These wires may also be used to conform to the standards for wiring required by the A.G.A. for gas range electrical cir cuits. Our Research and Design Engineers keep constantly abreast with special product applications as well as the many new unusually high temp erature insulation materials which can be of help to you. We offer you our research facilities for the development of special wires designed to meet any unusual requirements you may have. 1 SPECIAL INFORMATION ON RANGE AND APPLIANCE LEAD WIRES ROCKBE5TOS RANGE AND APPLIANCE LEAD WIRES Important Information -- Read Before Specifying Before reviewing the Standard Specifications for Rockbestos Electric or Gas Range and Ap pliance Lead Wires a working knowledge of the types of impregnation used in the felted asbes tos and/or braid is essential. There are two basic types -- "Hi-Temp" which is heat and flame resisting, and "Moistemp" which is heat, flame, and moisture resisting. You should also knowsomething of the type of application in w'hich they should be used. "Hi-Temp" Impregnation -- Scope and Limits "Hi-Temp" impregnation is designed for applications in which the temperature is usual ly high and there is little or no moisture. A waffle iron suggests itself as a typical example as temperatures in them frequently range around 600F. Under such heat, and also because of high wattage and close confinement, moisture accumulated during the "off" period is dissipated before a leakage path or a short can develop. This condition is duplicated in many electrical products, but care must be exercised in determining whether the temperature rise is sufficiently rapid to dry out the insulation, as a slowly rising temperature will permit leakage to build up to a point where a short may occur. "Moistemp" Impregnation -- Scope and Limits "Moistemp" impregnation is designed for applications in which the temperature is high but not extreme, and where humidity and moisture may cause current leakage. This is par ticularly true of some appliances and devices in which the insulation on the ends of the wires attached to heating units is exposed to high temperatures, while the insulation on the wires between the terminals may be in a moist, low temperature area. In such applications "Mois temp" impregnation should be specified as it is not only heat and flame resistant but moisture resisting as well. High-Dielectric and Asbestos Insulation This type of insulation, employed in the .033" and .045" Hi-Dielectric Range and Ap pliance Lead wires shown on pages 12 and 13, is designed to meet conditions similar to those detailed in the paragraph above but more exaggerated, as in heavy duty appliances such as electric ranges, gas ranges and water heaters. The combination of tape and felted asbestos provides high resistance to both heat and moisture, and the asbestos may be impregnated with either "Hi-Temp" or "Moistemp" compound as required. ROCKBESTOS PRODUCTS CORPORATION 2 RBB 00538 ROCKBESTOS STANDARD SPECIFICATIONS GENERAL -- CONDUCTORS STANDARD SPECIFICATION FOR ROCKBESTOS RANGE AND APPLIANCE LEAD WIRES Many companies in adopting Rockbestos Range and Appliance Lead Wires have requested suggestions for a standard specification. For this purpose we present the following outline which embraces all types of wire shown in this catalog. I General (a) Purpose: The purpose of this specification is to insure the furnishing of wire of rhe proper quality, manufactured in accordance with accepted practice. (b) Scope: This specification covers the construction and test requirements for range and appliance lead wires. (c) Materials and Workmanship: All materials and workmanship employed in manu facturing wires to this specification shall be of high quality so as to provide a finished product best suited for the purpose intended. (d) Applications All-Asbestos Insulations. These wires are suitable for operation at a maximum of 300 volts as open wiring in high temperature applications where little or no moisture is encountered. Asbestos High-Dielectric Insulations. These wires are suitable for operation at a maximum of 300 volts in electric ranges, gas ranges, hot water heaters or other appliances where they must oper ate under both heat and casual moisture conditions. The high dielectric tape in sert provides ample protection against casual moisture encountered within the appliance. II Conductors (a) Solid: Solid conductors shall be plain or coated copper in accordance with current ASA or ASTM specification. Other metals such as monel, nickel or copper clad soft steel per current NEMA Standard. (b) Stranded: Stranded conductors shall be bunched or concentric as required. The make-up of stranded conductors shall conform to current ASTM specifications. The individual strands shall be as specified for solid conductors in II (a). NEW HAVEN, CONNECTICUT 3 RBB 00539 STANDARD SPECIFICATIONS INSULATION -- SEPARATORS AND BRAIDS ROCKBESTqs Standard Specification -- Continued III Insulation (a) Asbestos 1. Materia!\ The asbestos insulation shall consist of selected quality, long fibre, chrvsotile asbestos commercially free from foreign particles of dirt, cotton seed and metallic oxides. It shall be well carded to prevent lumps and irregularities in the finished wire. The asbestos insulation shall be applied to form a smooth felted wall of uniform thickness as specified in the tables. The asbestos insulation after extraction of the impregnating compound shall contain not less than 80% by weight of asbestos. The total iron content shall not exceed 4% by weight of the asbestos. 2. Impregnation: The asbestos insulation shall be dried and saturated with a flame and heat resisting compound or a flame, heat and moisture resisting compound as specified. The compound shall consist of suitable high grade ingredients and shall retain its initial qualities during the normal life of the wire. The compound shall not develop any injurious chemical action within itself or with any component parts of the wire. (b) High Dielectric Tape: The tape, when used, shall consist of a high grade material substantially free from blisters or other imperfections and shall be applied to form a smooth wall of uniform thickness. IV Separators Unless otherwise specified, suitable separators may be used. V Braids . (a) Asbestos 1. Material: The asbestos yarn shall be of selected quality, long-fibre, chrysotile asbestos containing not less than 80% by weight of asbestos. The total iron content shall not exceed 6% by weight of the asbestos. 2. Application: Asbestos braids shall be applied to conform to current NEMA standards 3. Finish: Asbestos braid shall be finished with a suitable flame and heat resisting compound or saturated and finished with a flame, heat and moisture resisting compound as specified. ROCKBESTOS PRODUCTS CORPORATION 4 RBB 00540 ROCKBESTOS STANDARD SPECIFICATIONS TESTS--PHYSICAL -- ELECTRICAL Standard Specification -- Continued VI Tests A. Phy steal L. Dimensions: Inspection for dimensional requirements shill consist of tour deter minations. two to be made near each end of the sample of which the average shall comply with the requirements given in the tables. The measurements shall be made with a ratchet micrometer having 1 -t inch diameter faces. Each determination shall be the average of two measurements made at right angles to each other. 2. Resistance to Fl.wte: All wire made to this specification shall have fire resisting properties so that the rest specimens will meet ail of the requirements of the Underwriters' Laboratories standard vertical fiame test. B. Electrical l. Initial Dielectric StrenOgth: Initial dielectric strength tests shall be made on 5-foot lengths of finished wire with the center 3-foot section wrapped in metal foil. Voltages as indicated below' shall be applied for 1 minute. (1) All-Asbestos, flame and heat resistant, plain or braided -- 1000 volts, (2) All-Asbestos, aname, hl eat andj moi-sture res-istant (3) Asbestos-High Dielectric -- 2500 volts. f) p. lain --1000 volts. braided 1500 volts. 2. Dielectric Strength after Flame: A sample of ware having been previously subjected to the dame test shall be pre pared with the charred area of sizes Mo. 6 and Larger wrapped in metal foil, and sizes smaller than No. 6 buried in iron tilings or tine shot. The sample shall then withstand the application of 1000 volts for 1 minute when applied between con ductor and ground. 5. Bend-Dielectric Strength: A sample of wire shall be wound 5 turns around a mandrel having a diameter 5 times that of the sample. The ends of the spiral shall be held tightly by a mechan ical anchorage. Metal foil shall be tightly wrapped over the entire length of the spiral. The sample shall then withstand 1500 volts for 1 minute when applied be tween conductor and metal rod and foil. 4. Dielectric Strength While Immersed {Flame, heat and moisture resistant type only): A 2-foot sample of finished wire shall have the center 1-foot section immersed for 1 hour in tap water at room temperature. While still immersed the sample shall withstand 1000 volts for 1 minute when applied between conductor and water. NEW HAVEN, CONNECTICUT 5 RBB 00541 STANDARD SPECIFICATIONS TESTS--ELECTRICAL AND SAMPLING ROCKBESTOS Standard Specification -- Continued V Dielectric After Heating in Oven: A sample of wire shall be wound 5 turns around a mandrel having a diameter 5 times that of the sample. The ends of the spiral shall be held tightly by a mechan ical anchorage. The sample thus wound shall be placed in an oven at a temperature of -liO^F. ( = 20CF.) until the wire ceases to smoke but for not less than l hour. The sample shall be removed from the oven and metal foil shall be tightly wrapped over the entire length of the spiral. The sample shall then withstand 1000 volts for l minute when applied between conductor and metal rod and foil. 6. Heat and Water Test (Asbestos-High Dielectric type only): A 6-foot sample of wire shall be given a dielectric test by winding the center 5 feet on a brass mandrel having a diameter five times the diameter of the insu lated wire or l/> inch, whichever is greater. Place the sample on the mandrel into an oven heated at t'^C. = 2'C. (3504F. = -tF.) for a continuous period of 3 hours. After the duration of the heating period, remove the sample and allow it to return to room temperature. With the exception of the 6" section at each end. soak the sample, for a period of 5 hours, in a brine solution consisting of 0.1 grams of sodium chloride per liter of tap water. Immediately after removal from the brine solution, the sample shall rvithsrand 1200 volts, 60 cycles, applied for 1 minute between the conductor and the mandrel. Dielectric Strength (Grounding Wire Only) A 6-foot sample of wire shall be given a dielectric rest by winding the center live feet on a brass mandrel having a diameter live times the diameter of the insu lated wire. Place the sample on the mandrel into an oven heated at 177CC. = 2CC. (3503F. = 4F.) for a continuous period of 5 hours. After the duration of the heating period, the sample shall be removed and shall be subjected immediate ly to and shall withstand 600 volts, 60 cycles for 1 minute between the conductor and the mandrel. VII Sampling (a) Each of the required tests shall be made on one sample of each size and type of wire from each lot of 10,000 feet or fraction thereof. (b) If a sample fails to meet a prescribed test requirement, two additional samples shall be taken from the same length. If the two additional samples meet the test requirement then the lot shall be accepted. If either of these samples fail the length may be rejected. (c) If any length is rejected for failure to meet a requirement, then a sample shall be taken from each length of the balance of the lot and subjected to the particular test requirement to determine acceptance or rejection of that length. ROCKBESTOS PRODUCTS CORPORATION 6 RBB 00542 pockbestos CURRENT CARRYING CAPACITIES CORRECTION FACTORS GROUNDING WIRE CURRENT-CARRYING CAPACITIES FOR ASBESTOS INSULATED COPPER NICKEL AND MONEL CONDUCTORS USED FOR LEADS TO APPLIANCES AND OTHER EQUIPMENT (BASED ON INSTALLA TION EQUIVALENT TO THREE 1-CONDUCTOR WIRES IN CONDUIT). Size, i AAV.G. Current-Carrying Capacities, Amperes * -- per NEMA Standard ROCKBESTOS "MOISTEMP" INSULATION bleat and Moisture Max. Conductor Temp. 125C ROCKBESTOS "HI-TEMP" INSULATION Heat -- No .Moisture Max. Conductor Temp. Copper Nickel Monel 200 `C Copper 500; C. Nickel >oo C Monel IS 16 14 12 10 8 6 4 3 T 1. 17 > 29 38 49 63 35 114 131 U7 172 7.1 9.2 12.L 16.0 20.6 26.4 36.0 48.0 55.0 62.0 72.0 4.1 5.4 7.1 9.3 12.0 15.-1 20.7 27.9 32.0 36.0 42.0 : IS 23 32 -42 54 71 95 122 1-45 163 188 8.5 10.9 IT.2 20.0 25.6 53." 45.0 >7.9 68.8 77.4 SS.2 *5 * 6.6 0. 1 I2.1) L 5.5 20.3 3 NO -U.T 46.6 '5.7 -Vie $0 per Cent of these current ratings when 4 to 6 conductors ace laid dose together, md "0 per c;nt :or - to ) lonductor*. CURRENT CORRECTION FACTORS FOR VARIOUS AMBIENT TEMPERATURES Ambient Temp. C. 30 40 50 60 "0 80 90 100 120 no Correction Factors : Rockbestos "H i-Temp" Rockbestos "Moistemp*' 1.00 . 0.95 : ; 0.S9 : 0.83 : 0.76 0.69 j 0.61 i 0.51 : j *** : j *** ; Copper * ** +** 1.00 0.97 0.93 0,39 0.S6 0.32 0.72 0.63 Nickel and Monel *** *** 1 1.00 0.98 0.96 0.94 0.92 0.90 1 0.85 1 0.30 ALL-ASBESTOS APPLIANCE GROUNDING WIRE (NEMA Standard--1954) Construction'; Stranded copper conductor, felter asbestos insulation, green tinish, no braid. The insulation is impregnated -vith "Hi-Temp" heat and flame resisting compound. TABLE XI i Size j A.W.G. | 14 ! Stranding | 7/.0242 j Bare Diameter Inches .073 Nominal Thickness Felted Wall Mils 15 Nominal Finished Diameter Inches .103 Approx. , Net Weight ; In Lbs. ; 1000 Feet I 16 , Standard Package (Feet) j Non-Returnable i Large Metal Coils j Spools Wooden Reels 1000 ! 3000 5000 "Finished diameter given above i* average* A tolerance of plus or minus 5Cc is necessary due to variations in process of manufactures NEW HAVEN, CONNECTICUT 7 RBB 00543 .030' APPLIANCE LEAD WIRES COPPER, NICKEL OR MONEL SOLID OR STRANDED CONDUCTORS 300 VOLT ALL-ASBESTOS .030" APPLIANCE LEAD WIRES FOR WAFFLE [RON'S. HOTPLATES. FLAT [RONS. ROASTERS. GRilLS. TOASTERS COFFEE BREWERS. FOOD WARMERS, FRIERS. CONTROL PANELS. SWITCH BOARDS. WRAPPING SEALERS. COIL. MOTOR AND APPARATUS LEADS MAXIMUM OPERATING TEMPERATURES: HI-TEMP--200CC. (392=F.) MOISTEMP--125;C. (25~-F.) -".I. - ........... ... SOLID 1 -> ---------------- 1 STRANDED 3 "HI-TEMP" Insulation--Heat and Flame resisting--For use in High Temperatures, iittie or no moisture. "MOISTEMP" Insulation--Heat. Flame and Moisture resisting--Use for Heat and Moisture conditions. Conductors--Solid or Stranded Copper, Nickel or Monel--Insulated with .030" of felted asbestos. Specified stanJ.ifd conductors are insulated with an .050" will or relceJ asbestos impregnated with either "Hi-Temp'' heat and dame resisting compound oc 'Moistemp'' heat, dame and moisture resisting compound. Standard colors: black, white and red. Gray, green, blue, orange, brown and yellow available on special order. Special conductors such as tinned copper, copperweld. and alloys other than nickel or monel can be supplied on special order. When ordering oe sure to specify color and give table letters indicating type of conductor warned and preference for cither 'Hi-Temp or "Moistemp" impregnation. Solid Moistemp: Solid Hi-Temp: Table WBC -- Copper Table XBC --Copper Table WBM -- Monel Table XBM -- Monel Table WBN -- Nickel Table XBNT -- Nickel Size A.W.G. 8' 10 ; 12 U 16 IS 20 Bare Diameter Inches .128 .102 .081 .064 .031 .040 .032 Nominal j ^Nominal Thickness ' Finished : Felted Wall j Diameter : Inches Inches .030 i .188 : .030 ; .162 ! .030 ! 14L .030 030 .030 ; j 1 .124 lit .100 .030 092 , Approx. j Nec Weight ! In Lbs. ! Per 1000 Feet ! 60 j 39 I 27 18 13 ; 10 :7 Staa< lard Package (Feet) Non-Returnable Coils 500 1000 1000 1000 1000 1000 1000 Large Metal Spools -- 1000 1500 2 500 3500 5000 5000 Wooden Reels 5000 6500 8500 10000 10000 10000 10000 Coarse Stranded Moistemp: Coarse Stranded Hi-Temp: Table WBCS-- Copper Table XBCS --Copper Table WBMS --- Monel Table XBMS -- Monel Table WBNS -- Nickel Table XBN'S -- Nickel Sice A.W.G. S 10 12 14 . 16 IS 20 1 Stranding ~ .0383 .0303 ~ .0242 ~ .0192 ~ .0152 ' .0121 ; j 1 Bare Diameter Inches ,U6 .116 .092 .073 .058 .046 .056 Nominal Thickness Felted Will Inches .030 .030 .030 .030 .030.030 .030 Nominal Finished Diameter Inches .206 .176 .152 .153 .118 .106 .096 Approx. Net Weight In Lbs. Per 1000 Feet 62 42 28 19 14 9 8 Standard Package (Feet) Coils 300 1000 1000 1000 1000 1000 1000 Large Metal Spools ____ 1000 1500 2500 3500 4500 5000 Wooden Reels 4000 6000 7500 10000 10000 10000 10000 Flexible Stranded Moistemp: Table WBCF-- Copper Table WBMF -- Monel Table WBNF -- Nickel Flexible Stranded Hi-Temp: TableXBCF -- Copper Table XBMF -- Monel Table XBNF -- Nickel S 165 30 ; .131 .030 .211 64 500 -- 4000 10 : 104 30 .120 .030 ISO -f3 1000 1000 6000 12 j 63/30 i .095 .030 .155 29 1000 1500 7500 14 i 41. 30 .075 .030 .135 19 1000 2500 10000 16 i IS 20 j 26/30 16/30 10/30 1 .059 .045 .038 .030 .030 .030 .119 .105 .09S 14 L000 4000 10000 10 1000 4500 10000 7 1000 5000 10000 "'Finished diameter given above is average. A tolerance of plus or minus 5% is necessary due to variations in process of manufacture. ROCKBESTOS PRODUCTS CORPORATION RBB 00544 300 VOLT ALL-ASBESTOS .040'' APPLIANCE LEAD WIRES for ranges, water heaters, portable rheostats, blueprint machines. LABORATORY OVEN5. DRYERS, STERILIZERS, COMMERCIAL COFFEE BREWERS. BROILERS. TOASTERS AND GRILLS, CAR AND SPACE HEATERS, IRONERS. ETC. MAXIMUM OPERATING TEMPERATURES: HI-TEMP--200C. (392F,3 MOISTEMP--125C. (257CF.) .040' appliance lead wiirfi- COPPER, NICKEL OR MONEL SOLID OR STRANDED CONDUCTORS SOLID STRANDED * "HI-TEMP" Insulation--Heat and Flame resisting--For use in High Temperatures, little or no moisture, "MOISTEMP" Insulation--Heat, Flame and Moisture resisting--L'se for Heat and Moisture conditions. Conductors--Solid or Stranded Copper* Nickel or Monel--Insulated with ,040" of felted asbestos. Specified stjndjrd conductors are insulated with j#t .040" wall of felted asbestos impregnated with either "Hi-Temp" heic and flame resisting compound or '`Moistemp" heat, flame and moisture resisting compound. Standard colors: black, white and red. Gray, green, blue, orange, brown and yellow- on special order. Special conductors such as Tinned copper, copperweld, and alloys other than nickel or monel can be supplied on special order. When ordering be sure give table letters indicating type of conductor wanted, also specify color and preference for either "Hi-Temp" or "Moistemp'' impregnation. Solid Moistemp: Solid Ht*Temp: Table WCC -- Copper Table XCC --Copper Table WCM -- Monel Table XCM -- Monel Table WCN -- Nickel Table XCN -- Nickel Sire ? A.W'.G. j 81 10 1 12 \ 14 1 16 | 18 20 1 Bare Diameter Inches .128 .102 .081 .064 .051 .040 .032 Nominal Thickness Felted Wall Inches .040 .040 .040 .040 .040 .040 .040 j Nominal Finished Diameter Inches .208 .182 .161 .144 .151 .120 .112 || Appro*. | Net Weight j In Lbs. 1 Per 1000 Feet 1 64 i -13 i 30 ! 21 16 ! 192 Standard Package (Feet) Non- Retutnable Coils 500 1000 1000 1000 1000 1000 1000 Large Metal \ Spools : _; 1000 1500 2500 2500 4000 4000 i ! i Wooden Reels 4000 5000 6500 8500 10000 10000 10000 Coarse Srranded Moistemp: Table WCCS -- Copper Table WCMS -- Monel Table WCNS -- Nickel Coarse Stranded Hi-Temp; Table XCCS -- Copper Table XCMS -- Monel Table XCNS -- Nickel Size A.W.G. 3 10 12 14 16 IS 20 Stranding T .0486 .0385 ' .0305 7 .0242 7 .0192 7 .0152 7-'.0121 Bare Diameter Inches .146 .116 .092 .073 .058 .046 .036 Nominal Thickness Felted Wall Inches .040 .040 .040 .040 .040 .040 .040 Nominal Finished Diameter Inches .226 .196 .172 .153 .138 .126 .116 Approx, Net Weight In Lbs, Pet 1000 Feet 67 46 32 23 16 12 10 Static lard Package (Feet) Non-Returnable Coils Spools Large Metal Wooden Reels 500 1000 1000 1000 1000 1000 1000 ___ 1000 1500 2000 2500 3000 4000 3500 4500 6000 7500 10000 10000 10000 Flexible Stranded Moistemp: Table WCCF -- Copper Table WCMF -- Monel Table WCNF --Nickel Flexible Stranded Hi-Temp: Table XCCF -- Copper Table XCMF -- Monel Table XCNF -- Nickel S 165/30 .151 10 104/30 .120 12 65/30 .095 14 41/30 .075 16 26/30 .059 18 16/30 .045 20 10/30 .038 .040 .040 .040 .040 .040 .040 .040 .231 .200 .175 .155 .139 .125 .118 68 500 --, 3000 46 1000 1000 4500 32 1000 . 1500 6000 22 1000 2000 7500 16 1000 2500 10000 12 1000 3000 10000 10 1000 4000 10000 'finished diaxnerer given above is avenge. A tolerance of plus or minus 5% is necessary due to variations in process of manufacture. NEW HAVEN, CONNECTICUT 9 RBB 00545 .030 OR .040 TRIPLED APPLIANCE LEAD WIRES COPPER, NICKEL OR MONEL SOLID OR STRANDED CONDUCTORS 300 VOLT ALL-ASBESTOS TRIPLED APPLIANCE LEAD WIRES f FOR ELECTRIC RANGES AND OTHER HEAT GENERATING EQUIPMENT IN WHICH A TRIPLED LEAD WIRE CONSTRUCTION IS PREFERRED TO >I\GLE CONDUCTORS. MAXIMUM OPERATING TEMPERATURES: HI-TEMP--200-C. (392:F.) MOISTEMP--125=^, (25'-'F.) SOLID STRANDED "HI-TEMP" Insulation--Heat and Flame resisting--For use in High Temperatures, little or no moisture. "MOISTEMP" Insulation--Heat, Flame and Moisture resisting--Use for Heat and Moisture conditions. Conductors--Solid or Stranded Copper, Nickel or Monel--Insulated with .030" or ,040" of felted asbestos. Specifies sund,ird_ conductors are insulated with an .050" or .iHO" wall of felted asbestos impregnated with eithet Hi-Temp" heat and llame resisting compound or "Motstemp" heat, flame and moisture resisting compound, polartred with black, white and red finishes, and tripled, special conductors such as tinned copper, copperweid and alloys orher than nickel or monel can be supplied on special order. When ordering be sure to give table letters indicating type of conductor and insulation thickness wanted ana -pecify preference for either "Hi-Temp" ot "Moistemp ' im pregnation or other colors. The Hi-Dielectric Range and Lead Wires on the following pages ate also tripled it Jesired. .030" Solid Moistemp: .030" Solid Hi-Temp: .040" Solid Moistemp t .040" Solid Hi-Temp: Sire A.W.G. t: u 16 18 Bare Diameter Inches .081 ,06a .051 ,0-i0 i j j | ; Table WDC--Copper Table XDC--Copper Table WEC--Copper Table XEC--Copper Nominal Finished Diameter5 (Inches) .030" .303 .167 .239 .215 .040" .346 .310 .282 .258 Table WDM--Monel Table XDM--Monel Table WEM--Monel Table XEM--Monel Approx. Net Weight Per M Ft, (Pounds) .030" S3 57 40 30 .040" 92 65 47 35 Table WDN--Nickel Table XDN--Nickel Table WEN--Nickel Table XEN--Nickel Standard Package (Feet) Coils 250 250 400 500 Wooden Reels I 400 2000 2000 2400 .030" Coarse Stranded Moistemp: .030" Coarse Stranded Hi-Temp: .040" Coarse Stranded Moistemp: .040" Coarse Stranded Hi-Temp: Size A.W.G. L2 14 16 VS Stranding 7 .0305 " .0242 " .0192 ~ '.OL52 Bare Diameter Inches .092 .073 .058 .046 Table WDCS--Copper Table XDCS--Copper Table WECS--Copper Table XECS--Copper Nominal Finished Diameter* (Inches) .030" .327 .286 .254 .228 ) ; : i .040" .370 .329 .297 .271 Table WDMS--Monel Table WDNS--Nickel Table XDMS--Monel Table XDNS--Nickel Table WEMS--Monel Table WENS--Nickel Table XEMS--Monel Table XENS--Nickel Approx. Net Weight Per M Ft. (Pounds) . Standard Package (Feet) .030" .040" Coils : Wooden Reels 89 98 i 250 . 1000 61 71 ' 250 1500 43 52 ; 5oo 1 3000 54 40 i 500 2400 .030" Flexible Stranded Moistemp: TableWDCF--Copper Table WDMF--Monel TableWDNF--Nickel .030" Flexible Stranded Hi-Temp: Table XDCF--Copper Table XDMF--Monel Table XDNF--Nickel ,040" Flexible Stranded Motstemp: Table WECF--Copper Table WEMF--Monel Table WENF--Nickel .040" Flexible Stranded Hi-Temp: Table XECF--Copper Table XEMF--Monel Table XENF--Nickel 12 65,50 14 41 30 16 26/30 18 16/50 .095 .075 .059 .045 -334 .290 .256 .226 | ) j ! .377 .334 .299 .269 * Finished diameter given above is avenge. A tolerance of plus or minus i 89 98 250 1000 i 60 68 250 1500 i 43 50 500 2000 l 31 37 500 2500 is necessary due to variations in ptoteM of manufacture. ROCKBESTOS PRODUCTS CORPORATION 10 RBB 00546 300 VOLT ASBESTOS INSULATED WIRES N'EMAf TYPES A and AI "MOISTEMP" INSULATION--FOR RANGES. WATER HEATERS. APPLIANCES AND APPARATUS REQUIRING WIRE HIGH IN DIELECTRIC STRENGTH AND RESIST ANCE TO HEAT, HUMIDITY AND MOISTURE. "HI-TEMP" INSULATION--FOR APPLIANCES REQUIRING ONLY A HEAT AND FLAME RESISTANT INSULATION. NEMA TYPES A and AI ASBESTOS INSULATED WIRES SOLID OR STRANDED CONDUCTORS MAXIMUM OPERATING TEMPERATURES: MOISTEMP--125 SC. (257F.)--NEMA TYPE AI HI-TEMP--200eC, (392F.)--NEMA TYPE A UVEMA Standard WC-l. 1955 lists Types A and AI m >0 and a0 mils of asbestos insulation, plus a separator it used. The "Moistemp" constructions shown with and t5 mils or insulation have a j mil dielectric tape insert plus the 50 and a0 mil NEMA Standard insulation. ` STRANDED OR SOLID "MOISTEMP" Insulation~-Hear, Flame and mois ture resisting--Use for Heac and moisture condi tions. TABLF WSC--Solid Copper Conductor. TABLE WSCF--Stranded Copper Conductor, "HI-TEMP" Insulation--Heat and Flame resisting --Use for High Temperatures, little or no moisture. TABLE XSC--Solid Copper Conductor. TABLF XSCF--Stranded Copper Conductor. HOW and WHERE TO SPECIFY EITHER "MOISTEMP" or "HI-TEMP" INSULATIONS These NEMA Type Appliance wires are furnished in two basic types ot impregnations: _ "MOISTEMP1' impregnation in the felted wall is designed for applications where the temperature is high but nut extreme, and where humidify and moisture may cause current leakage. For example, tn some appliances and devices the insulation, at the ends of the wires attached to heating units is exposed to high temperatures while the rest of the were run may be m a moist, lower temperature area. For those applications specify 'Moistemp" impregnation as it is not only heat and dame resistant but moisture resisting as well. "HI-TEMP" Impregnation in the felted wall is neat and Hame resisting and designed for applications where the tem perature is usually high with little or no moisture Under heat, and because of high wattage and dose confinement, moisture accumulated during the 'off* period is dissipated before a leakage path or short can develop. This condition exists in many products, but care must be exercised in determining whether the temperature rise is sufficiently rapid to dry out the insulation, as a slowly rising temperature will permit leakage to build up to a point where a short may uccur. Moistemp; Solid Table WSC -- Copper High dielectric tape and felted asbestos insulation totaling 43 mils on Sizes 8-10-12; 33 mils on Size 14, Size A.W.G. Stranding Bare Diameter inches Nominal Finished Diameter Inches Approx. Standard Package (Feet) Net Weight Non-Returnable In Lbs. ^ Large Metal Wooden Per 1000 Feet Coils Spools Reels 14 Solid .064 12 Solid .081 10 Solid .101 8 Solid .128 .130 .167 .188 .214 24 1000 2500 10000 38 1000 1500 6500 54 i 1000 1000 5000 79 i 500 -- 4000 Moistemp: Stranded 14 41 50 12 65 30 10 105 30 3 165 30 Table WSCF -- Copper .075 .095 .120 .176 .141 .181 .206 237 Same insulation note as above. 25 1000 2000 40 : iooo 1500 57 i 1000 iooo 85 ; 500 -- 8500 5000 4000 3000 Hi-Temp: Solid Table XSC -- Copper 40 mils of felted asbestos on Sizes 3-10-12; 30 mils of felted asbestos on Size 14. 14 Solid 12 . Solid 10 Solid S Solid .064 .081 .101 .128 : i ; | .124 .161 .182 .208 21 . 1000 2500 36 1000 1500 51 1 1000 1000 76 i 500 -- 10000 6500 5000 4000 Hi-Temp: Stranded Table XSCF -- Copper Same insulation note as above. 14 4t 30 .075 12 65/30 .095 10 105/30 .120 8 165/30 .176 -135 .175 .200 .231 22 | 1000 i 2500 38 1 1000 1500 55 ! iooo 1000 81 i 500 -- finished diameter given above it average. A tolerance of plus or minus 5% is necessary due to variations in process of manufacture. 10000 6000 4500 3000 NEW HAVEN, CONNECTICUT 11 RBB 00547 - i fn HI-DIELECTRIC .033' RANGE AND APPLIANCE LEAD WIRES COPPER, NICKEL OR MONEL SOLID OR STRANDED CONDUCTORS 300 VOLT HI-DIELECTRIC .033 (NEMA STANDARD) RANGE AND APPLIANCE LEAD WIRES FOR ELECTRIC RANGES. WATER HEATERS. APPLIANCES AND QL'IRIN'G A WIRE WHICH IS HIGH IN DIELECTRIC STRENGTH ANCE TO HEAT. HUMIDITY AND MOISTURE. ' '' ; scV; ` MAXIMUM OPERATING TEMPERATL'RES: HI-TEMP--200=C. (392-F.) MOISTEMP--USto. (25T-F.) SOLID OR STRANDED "HI-TEMP" Insulation--Heat and Flame resisting--For use in High Temperatures, little or no moisture. "MOISTEMP" Insulation--Heat. Flame and Moisture resisting--Use for Heat and Moisture conditions. Conductors--Solid or Stranded Copper, Nickel or Monel--Insulated with high dielectric cape and felted asbestos to a combined thickness of .033". 3pcrCincJ sundjrJ conductors are insulated with mgbidielec* tnc and felted asbestos to a combined thickness of .033" to provide high resistance to both heat and moisture. The .libescos insulation is impregnated with either "Hi-Temp" heat and dame resisting compound or "Moistemp" heat, dame mj moisture resisting compound as specified. Standard colors: buck, white and ted. Gcav. green, blue, orange, begwn aad \dlvsw on special order. When ordering be sure to specify color and give table letters indicating type of conductor wanted and preference for either "Hi-Temp" or '`Moistemp" .moruc nation. ' The Range and Appliance lead wires listed on rhr- pace meet all requirements of rhe latest NEMA STANDARDS FOR ASBESTOS INSULATED RANGE WTRE. Special conductors such as tinned copper, coppvrwcld .r.d aUov* other than nicks- c monel can be supplied on >rec:a: order. Also made up m tripled construction like toe uiro illustrated on page 10. Solid Moistemp: Solid Hi-Temp: Table WFC -- Copper Table XFC--Copper Table WFM -- Monel Table XFM --Monel Table WFN -- Nickel Table XFN --Nickel Size ; A.W.G. : : no =:! 7 U 16 18 Bare Diameter Inches .102 .081 .064 .Oil .040 Nominal i Thickness j Tape and ] ; Felted Wall | ! Inches . .033 .033 .033 .033 .033 . | [ ,. ^Nominal Finished Diameter Fnches . 168 .U7 .130 .117 .106 Approx. Nee Weight In Lbs. Per 1000 Feet 43 29 20 14 n Statidard Package (Feet) j Nod*fteturnable Coils ! Large Metal r Spools Wooden Reels 1000 1000 1000 1000 tooo j ! 1 I 1000 1300 2300 3500 4S00 6^00 8*00 1001)0 L000Q 10000 Coarse Stranded Moistemp: Table WFCS -- Copper Coarse Stranded Hi-Temp: Table XFCS --Copper Table WFMS -- Monel Table XFMS --Monel Table VCFNS -- Nickel Table XFNS --Nickel Size A.W.G. "<12 14 16 18 . Stranding : 1 ' 1 ' ".0385 7 .0305 7 .0242 7 ".0192 7 ".0152 Bare Diameter Inches .U6 .092 .073 .058 ,046 Nominal Thickness Tape and Felted Wall Inches .033 .033 .033 033 .033 Nominal Finished Diameter Inches .182 .158 .139 .124 .112 Approx. Net Weight In Lbs, Per 1000 Feet 44 31 21 15 12 Standard Package (Feet) | Non-Returnable Coils 1000 1000 1000 1000 tooo Large Metal 1 Spools | 1000 j 1500 | 2000 3000 4000 ; i j Wooden Reels 5000 7500 10000 10000 10000 Flexible Stranded Moistemp: Table WFCF -- Copper Table WFMF -- Monel Table WFNF -- Nickel Flexible Stranded Hi-Temp: Table XFCF -- Copper Table XFMF --- Monel Table XFNF -- Nickel 131310 i 104'30 .120 .033 .186 46 1000 1000 I 5000 312 i 14 16 i 18 i 65 50 41 30 26/30 16-20 .095 .075 .059 .045 033 033 .033 .033 .161 .141 .125 .lit 31 1000 1500 6500 21 1000 2000 8500 15 tooo 5000 10000 H 1000 4000 I 10000 Finished dizmetet given *bove is ivtn**- A toletsnce of plus ot minus 5<7b is necessary due to variations in process of manufacture. These sizes nor NEMA Standard--NEMA requires 40 mils insulation for these sizes. See page. 11. ROCKBESTOS PRODUCTS CORPORATION 12 RBB 00548 300 VOLT HI-DIELECTRIC .043" RANGE AND APPLIANCE LEAD WIRES FOR ELECTRIC RANGES. WATER HEATERS, APPLIANCES AND APPARATUS REQUIRING A WIRE WHICH IS HIGH IN DIELECTRIC STRENGTH AND RE SISTANCE TO HEAT. HUMIDITY AND ' [OISTURE. MAXIMUM OPERATING TEMPERATURES: HI-TEMP--200C. (3S>2CF.) MOISTEMP--I253C. (257CF.) HI-DIELECTRIC .043' RANGE AND APPLIANCE LEAD WIRES COPPER. NICKEL OR MONEL SOLID OR STRANDED CONDUCTORS *-------------- --------------- SOLID OR STRANDED i g " '. "1 * 11 1 1 "HI-TEMP" Insulacior--Heat and Flame resisting--For use in High Temperatures, little or no moisture. "MOISTEMP" Insulation--Heat, Flame and Moisture resisting--Use for Heat and Moisture conditions. Conductors--Solid or Stranded Copper, Nickel or Monel--Insulated with high dielectric tape and felted asbestos to a combined thickness of .043". Specified! standard conductors are insulated with high*diele<N trie tape and felted asbestos to a combined thickness of .043" to provide high resistance to both heat and moisture. The a>bestos insulation is impregnated with either "Hi-Temp" heat and dame resisting compound or "Moistemp" heat, flame and moisture resisting compound as specified. Standard cofocs: black, white and red. Gray, green, blue, orange, bcown and yeliow on special order. When ordering be sure to specify color and give cable letters indicating type of con Solid Moistemp: Solid Hi-Temp: Table WGC -- Copper Table XGC -- Copper ductor wanted and preference for either "Hi-Temp" or "Moistemp" impregnation. The Range and Appliance Lead wires listed on this page meet the test requirements for the latest NEMA STAND* ARDS FOR ASBESTOS INSULATED RANGE WIRE. Special conductors such as tinned copper, copperweld and alloys other than nickel or monel can be supplied on special order. Also made up in tripled construction like the wires illus trated on page 10- Table WGM -- Monel Table XGM -- Monel Table WGN -- Nickel Table XGN -- Nickel 1 Size A.W.G. | Bate Diameter Inches Nominal Thickness Tape and Felted Wall Inches Nominal Finished Diameter Inches s; .128 .043 .214 10 .102 .043 ASS 12 ! .081 .043 .167 U: .064 .043 .150 16 j .051 .043 .137 IS ; .040 .043 .126 Coarse Stranded Moistemp: Table WGCS -- Copper Coarse Stranded Hi-Temp: Table XGCS --Copper Approx. Net Weight In Lbs. Per 1000 Feet Standard Package (Feet) Non-Returnable Coils Large Metal Spools Wooden Reels 66 500 4000 45 tooo 1000 5000 32 tooo 1500 6500 22 1000 2000 8500 16 1000 2500 10000 13 1000 3000 toooo Table WGMS--Monel Table WGNS-- Nickel Table XGMS --Monel Table XGNS --Nickel Size A.W.G. Stranding Bare Diameter laches Nominal Thickness Tape and Felted Wall Inches ^Nominal Finished Diameter Inches Approx. Net Weight In Lbs. Per 1000 Feet Stan Jard Package (Feet) Non-Returnable Coils Large Metal Spools Wooden Reels 8 7 .0486 .146 .043 .232 10 7 .0385 .116 .043 .202 12 7-.0305 .092 .043 .178 14 7..0242 .073 .043 .159 16 7 '.0192 .058 .043 .144 18 7 '.0152 .046 .043 .132 69 500 ____ 3000 48 1000 1000 4000 34 1000 1500 6000 24 tooo 2000 7500 17 1000 2500 8500 13 1000 2500 10000 Flexible Stranded Moistemp: Table WGCF -- Copper Table WGMF -- Monel Table WGNF -- Nickel Flexible Stranded Hi-Temp: Table XGCF -- Copper Table XGMF -- Monel Table XGNF -- Nickel 8 165/30 .151 .043 .237 10 104/30 .120 .043 .206 12 65,-30 .095 .043 .181 14 41-30 .075 .043 .161 16 26/30 .059 .043 .145 18 16/30 .045 .043 .131 71 500 -- 3000 48 1000 1000 4000 34 1000 1500 5000 23 1000 2000 6500 17 1000 2500 8500 13 1000 2500 10000 "Finished diameter given above i* average. A tolerance of plus or minus 5% t* necessary due to variations in process of manufacture. NEW HAVEN, CONNECTICUT 13 RBB 00549 U. L. APPROVED STOVE WIRES COPPER, NICKEL OR MONEL SOLID OR STRANDED CONDUCTORS ' "MOI5TEMP"--"HI-TEMP" 300 VOLT ALL-ASBESTOS Underwriters' Approved ' STOVE WIRES FOR RANGES. HOT PLATES. OVENS, FOOD WARMERS, GRILLS, DRVER5. sp\CE HEATERS. LEADS FOR HEAT GENERATING APPARATUS, ETC. MAXIMUM OPERATING TEMPERATURES: HI-TEMP--200;C. (392=F ) MOISTEMP--125;C. (25':F 3 21 I. SOLID OR STRANDED COPPER. NICKEL OR MONEL CONDUCTOR J, FELTED ASBESTOS IMPREONATEO WITH EITHER "HI-TEMP" OR "MOISTEMP" COMPOUNDS 1. ASBESTOS MAID, "HI-TEMP" OR "MOISTEMP" IMPREGNATED 3 21 "HI-TEMP" Insulation--Heat and Flame resisting--Use for High Temperatures, little or no moisture. "MOISTEMP" Insulation--Heat, Flame and Moisture resisting--Use for Heat and Moisture conditions. HOW and WHERE TO SPECIFY EITHER These Underwriters' approved Stove wires are furnished in two baste types of impregnations: 'HI-TEMP" Impregnation in both the felted wall and braid is heat and fiame resisting and designed for applications where the temperature is usually high with little or no moisture. Under heat* and because of high wattage and dose confinement, moisture accumulated during the "off" period is dissipated before a leakage path or short can develop. This condition exists in many products* but cafe must be exercised in determining whether the temperature rise is sutficiently rapid to dry out the insulation, as a slowly rising tempera' `HI-TEMP'' or "MOISTEMP" INSULATIONS tuce will permit leakage to build up to a point where, a short may occur. "MOISTEMP'1 impregnation in both the felted wall and braid is designed for applications where the temperature is high but not extreme, and where humidity and moisture may cause current leakage. For example, in some appliances and devices the insulation at the ends of the wires attached ro heating units is exposed to high temperatures while the rest of the wire tun may be in a moist, lower temperature area. For these applications specify ``Moistemp" impregna tion as it is not only heat and fiame resistant but moisture resisting as well. CURRENT-CARRYING CAPACITIES ire listed on page 7 for these wires along with Current Correction Factors for various ambient temperatures. SPECIAL CONDUCTORS such as Copperwerd or alloys other than nickel or monel or extra flexible conductors can be supplied on special order. NOTE: Tables A and R are rated 300 volts in this catalog since stove wire is limited to a 300*volt rating, however these tables are shown in our 10*G catalog with a 600*volt fating for industrial usage. Solid Moistemp; Solid Hi-Temp: Table A -- Copper Table A-300 -- Copper Table AM -- Monel Table AM-300 -- Monel Table AN -- Nickel Table AN-300 -- Nickel ; Nominal Thickness -- Mils imioal { Approx. ' ^Standard Approx, Bare ished 1 Net Wgt. Shipping Shipping Diam. . Felted Asbestos i Dia merer ! in Lbs. - Length Weight Size | Inches Wall I. Braid 1 In ches | per 1000' Feer ' per tOOO' **18 AWG **l 6 14 12 10 8 , ' ' .040 .051 .064 .081 .102 .128 : . ; ; : 30 40 30 i 40 30 ; 40 30 j 40 30 I 40 50 ! 40 .180 i , .195 : .205 i ! '225 .245 t ! "27 18 500'C 22 1 500'C 28 500'C 38 ; 500'C 32 \ 500'C i 69 j 500'C 1 22 28 33 43 57 79 Coarse Stranded Moistemp: Coarse Stranded Hi-Temp: Table R -- Copper Table R-300 -- Copper Table RM -- Monel Table RM-300 -- Monel Table RN -- Nickel Table RN-300 -- Nickel Nominal Thickness -- Mils Bare Diam. Felted Asbestos Size Stranding: Inches Wall Braid Nominal j Approx. Finished Net Wgt. Diameter 1 in Lbs. Inches i per 1000' Standard Shipping Length Feet Approx. Shipping Weight per 1000' 1 Moistemp Hi-Temp Moistemp Hi-Temp IMoistempS Hi-Temp Moistemp] Hi-Temp ** 18 AWG 7/.0152 j .046 30 30 40 .190 .190 21 : 18 500'C 27 24 **16 7/.0192 j .058 30 30 40 .200 .200 27 | 23 500'C 32 ! 28 14 7/0.242 .073 30 30 40 .215 .215 33 29 500'C 38 j 35 12 7/.0305 .092 40 30 40 .255 -235 47 j 44 500'C 52 45 10 7/.0385 .116 40 30 40 ,280 .260 63 ! 54 500'C 69 i 60 8 7/.0486} .146 40 30 40 .310 .290 89 1 72 500'C 94 l 83 Finished diameter given above is average. A tolerance of plus or minus W jj necessary due to vamtionj in process of manufacture. **Noc luted by Underwriters' Laboratories +C--Coils. ROCKBESTOS PRODUCTS CORPORATION 14 RBB 00550 1000 VOLT {Underwriters' Approved) APPLIANCE LEAD WIRE FOR THE INTERNAL WIRING OF APPLIANCES SUCH AS FLUORESCENT FIX TURES. MAXIMUM OPERATING TEMPERATURE 90=C. (194F.) If. L APPROVED TOOO VOLT APPLIANCE LEAD WIRE I. SOLID 09 ST4AN0ED PLAIN COPPEft CONDUCTORS 3 2. synthetic tape 21 3. impregnated felted asbestos This Underwriters' Approved 1000 volt Appliance lead wire is available with either solid or stranded plain copper con* ductors insulated with high dielectric tape and impregnated felted asbestos. These wires were designed for the internal wiring of light ing appliances and fixtures which called for a 1000 volt wire to operate dependably in high temperatures. This wire is especially recommended for use in connection with cold cathode lighting fixtures where starting voltages exceed 300 volts. These wires are furnished in black, white, and red as stand ard colors. TABLE FE 1000 VOLTS ILL. APPROVED Size A.W.G. 18 16 14 , Stranding . Solid Solid Solid : , Bare DiamInches .040 .051 .064 j Nominal Thickness--Inches j Nominal | Approx. I Standard i Approx. Finished . Net Wgt. Shipping , Shipping : Synthetic j : Felted . Diam. ' In Lbs. Length i Weight ! Tape | 1 Asbestos . Inches* : Per 1000' Feet | Per 1000' ! .0065 : .0115 .0115 .031 .026 .026 : .115 ; .130 ' | .140 ' u 14 20 1000 C iooo c 1000 C 13 17 24 Stranded 18 16/30 : .045 i .0065 ! .031 \ .120 ; 11 : iooo c i 16 26/30 j .059 : .0115 i .026 ; .135 i 15 ; iooo c : 14 41/30 i .075 : .on5 ; .026 i .150 \ 21 j ; iooo c | Above is* Finished diameter given average. A tolerance of plus or minus *>% is necessary due ro variations in process of manufacture. 13 18 25 NEW HAVEN, CONNECTICUT 15 RBB 00551 U. L. APPROVED 1000 VOLT APPLIANCE LEAD WIRE w 1000 VOLT ASBESTOS and GLASS (Underwriters' Approved) APPLIANCE LEAD WIRE C FOR USE IN RADIO EQUIPMENT. AMPLIFIERS AND THE INTERNAL WIRING OF ELECTRONIC EQUIPMENT. MAXIMUM OPERATING TEMPERATURE 90cC. (194CF.) 1. SOLID 0* STRANDED TINNED COPPER CONDUCTOR 2. SYNTHETIC TAPE 3. IMPREGNATED FELTED ASBESTOS a. LACQUERED GLASS SRAiO This Underwriters' Approved 1000 volt Appliance wire is available with either solid or stranded tinned copper con ductors. It is insulated with helically applied synthetic tapes and impregnated felted asbestos and covered overall with a glass braid lacquered to a hard smooth finish. Here is an easy stripping, high dielectric wire resistant to dame, hear and moisture, grease and oil. With its 1000 volt rating it is recommended for use in Radio Equipment, Amplifiers and for the internal wiring of Electronic Equipment. Standard finish tor this wire is white lacquered glass braid. This wire can be color coded by the use of colored tracers m the glass braid. TABLE FG 1000 VOLTS Size A.W.G. l Stranding j Bare DUm. Inches ; Nominal Thickness---Inches ! Svnthetic Felted ! Braid ! Tape Asbestos : Thickness 22 Solid : .025 i .010 .0085 1 .005 20 Solid .032 ; .010 .0085 j .005 IS Solid ,040 j .010 .0085 ; .005 16 Soiid .051 ; .010 .0085 ' .0075 U Solid , .064 | .010 .0085 i .0075 12 Solid .081 1 .010 .0085 j .0075 ^Nominal Finished Diam. Inches .080 .085 .095 .110 .120 .145 U L. APPROVED Appro*. Standard Net Wgt. Shipping In Lbs. | Length Per 1000' i Feet ; Appro*. Shipping Weight Per 1000' 5 1000 c 6 1000 c 9 1000 c 12 1000 c IS iooo c 28 1000 c 6 7 10 14 21 34 Stranded 22 ' 7/30 ! O rfN O .010 20 10/30 j ,038 .010 18 16/30 ; .045 j .010 16 | 2b 30 .059 .010 14 I 41.30 .075 .010 12 : 65 3 .095 .010 .0085 1 .0085 | .0085 1 .0085 .0085 .0085 | ! i .005 .005 .005 .0075 .0075 .0075 o o .085 | 5 : iooo c ; 6 I iooo c .loo ! 9 ! 1000 C ! 1 iooo c 1 .120 S 12 .130 | 13 ! iooo c | .155 j 29 i 1000 C i `Finished diameter given above is average. A tolerance of plus or minus <<*3> is necessary due to variations in process of manufacture. 6 7 11 15 22 36 ROCKBESTOS PRODUCTS CORPORATION 16 RBB 00552 DISTRICT SALES OFFICES MAIN OFFICE and FACTORY Nicoll and Conner Sts. NEW HAVEN 4, CONN. NEW YORK 17. N. Y. Room 4516. Chrysler 31 dg. 405 Lexington Ave. CLEVELAND 21, OHIO 2000 Warrensville Center Rood DETROIT 21. MICH. 3330 West MoNiohoU Road ST. LOUIS 21, MO. .ambers--St. Louis Municipal Airport SEATTLE 3. WASHINGTON 40 1 5 Aurora Ave. ATLANTA S, GA. 3127 Maple Drive Room 20J CHICAGO 24. ILL. 4534 West Madison St, DALLAS 5. TEXAS 4655 N. Central Expressway PITTSBURGH 19, PA. 2520 Kopoers 3ldg. BURLINGAME, CALIF. 6 Gulttatd Road LOS ANGELES 5, CAL. 4020 w. Third St. Warehouses: Chicago, III. -- Syrtirtgame, California Mgnut actuttd iji Canada by Phillips Electrical Co. il^53) ltd., 26 Hallingtr Rood. To/onto 13. On tori o, Canodo. Manufactured in Australia by Cabl*s MgJttr* Australia Ply. ltd., livtipool, N.S.W.. Australia. ROCKBESTOS PRODUCTS CORPORATION NEW HAVEN 4, CONNECTICUT s J 00554 300 VOLT ASBESTOS and GLASS APPLIANCE LEAD WIRE FOR RANGES, ROASTERS, WATER ind SPACE HEATERS. INFRA-RED OVENS, LEADS FOR HEAT GENERATING APPARATUS. ETC. . MAXIMUM OPERATING TEMPERATURE 20OC. (392F.) ASBESTOS and GLASS COVEREI LEAD WIRE * * ' * NICKEL CONDUCTORS--SQUD OR STRATI 1. NlCKEl COMDllCro* fSOLJO OS STRANOED) 3 2. SYNTHETIC TAfg t 4 3. FElTEfi ASBESTOS t. GLASS MAlO, S'UCONt COATED This ideal high temperature insulation of high dielectric tapes combined with felted asbestos impregnated with "HiTemp," heat and flame resistant compound and covered overall with a silicone coated glass yarn braid. Standard conductors tor these Asbestos and Glass insulated appliance lead wires are solid and stranded nickel for a mjximum operating temperature of 200aC. These appliance lead wires are used tor high temperature applications where the temperature at terminal connections is too high to allow the use of copper conductors. They were originally designed as leads in electric range deep well cooker units where high temperatures in conhned areas along with the Hexing action of raising and lowering the unit called for a wire to withstand the heat and remain permanently flexible. Standard color: Natural (Tan) only. TABLE AG 300 VOLT (Asbestos-Glass Covered) Bare Size Diacnetee A.W.G. Stranding : Inches Nominal Thickness-Mils Dielectric \ Feked Braid Insert ! Wall Thickness Nominal Dtam, Inches Approx. Net Wgt. In Lbs. Per 1000' 1 2 Solid ' .031 14 Solid j .064 16 Solid ; .051 2.5 1 30.5 2.5 : 30.5 2.5 ; 30.5 7.5 7.5 7.5 .165 .150 .135 33.9 24.8 18.4 Standard Package-FtNon-Returnable Lg. Metal ! Wooden Coils Spools Reels 1000 ! 1000 ; 1000 : i500 2500 3500 ; 8500 : 10,000 j 10,000 Approx. Shipping Weight Per 1000' 40 29 22 12 65/.010 i .095 14 1 4i '.oio : .075 16 : 26 -'.010 ; .059 2.5 I 30.5 2.5 i 30.5 2.5 | 30.5 Stranded 7.5 .180 7.5 .160 7.5 .145 36.1 26.0 19.4 1000 | 1 1000 j j 1000 1 1500 2500 4000 { j 7500 2500 4000 43 31 23 RBB 00553