Document jy2b9zr9d2B2o21vVzjoB0VbR
FILE NAME DuPont DUP
DATE 1969 Nov 1
DOC DUP202
DOCUMENT DESCRIPTION Report - Old Hickory Textile Fibers - Asbestos
Dust Control
ASBESTOS DUST CONTROL CONTROL CONTROL
DUP 1012406 DU 053453
ASBESTOS DUST CONTROL
e
a 1
Old Hickory Textile Fibers Old Hickory Tennessee November , 1969
DUP 1012407 DU 053454
ASBESTOS DUST CONTROL
This summary report is a compilation of work done by
Analytical Research Laboratory Chemical Control Laboratory and Works Engineering Section Old Hickory Textile Fibers Old Hickory Tennessee
By
R. E. Tyree Area Engineer Maintenance Engineering
DUP 1012408 DU 053455
TABLE OF CONTENTS
INTRODUCTION . .
e . e e e e
DEVELOPMENT OF OLD HICKORY'S ASBESTOS DUST EXPOSURE LIMITS THRESHOLD LIMIT VALUES
SAMPLING PROCEDURE
SAMPLE DATA
..,
RECOMMENDATIONS
SUMMARY
....
ACKNOWLEDGMENTS
APPENDIXES
Page
No.
DUP 1012409
DU 053456
I. Introduction
A. Objectives
Reference
Letter J. H. Sigman Cox to R. J. Blair 8/8/68 Letter R. J. Blair to O. W. Hess 8/16/68 See Appendix A
1 Study jobs where asbestos dust is
present take dust
samples for analysis and determine when
protection is required
respiratory
2 Provide information to the Textile Fibers
that could be used
Department
as a guide for a uniform safely
standard
3 Recommend minimum equipment requirements for
dust control
adequate
Premise
1. Asbestos dust control is the
prevention of high concen-
trations of asbestos dust entering the lung of asbestos
workers insulators and any other person
handling or working with asbestos
exposed to
2- Asbestosis is a fibrogenic scar producing pneumo-
coniosis dust disease of the lung due to inhalation
of asbestos fiber dust
In its
it
more advanced stages
can impair respiratory fufunnction ction with production of
emphysema Total disability and
Especially in smokers there is a marked increase in
incidence of several varieties of cancer
There is no known cure for asbestosis therefore every
reasonable effort be made from a
to
humane standpoint
control the dust and prevent it from
lung
entering the
DUP 1012410 DU 053457
II
Development of Old Hickory's Threshold Limit Values
Asbestos
Dust
Exposure
Limits
In April 1968 the Engineering Department's Construction Division established procedures for monitoring air using personnel air sampling instruments see Appendix B Samples were then sent to the University of Pittsburgh for microscopy analysis by qualified experts
The Construction Division's established Threshold Limit Value
TLV for total dust count at this time was set
particles per cubic foot of air for industry
This was 1/10
at 500,000
the TLV set
Old Hickory's Asbestos Committee
of asbestos dust and control and studies
has has
researched the concluded from
subject
their
Asbestos dust consisted of grains and fibers 1
The fibers are the major recognized health hazard
Large dust grains
studies show that
do enter the lung
cannot enter the lungs but medical
long fibers as long as 200 microns
and cause asbestosis
2
@ Prior to 1960 exposure measurements were based on
particle counting methods which were not efficient
for TLV
fiber count had been set
Therefore by necessity the asbestos for dust concentrations which were
measured primarily by grain count
@e In the late 1950's new sample and count techniques were developed which provided much improvement in the accuracy and efficiency of counting asbestos dust grains and fibers This method was particularly effective in the fiber sizes of most concern i.e.
5 microns and greater
length 1
Fiber is defined as any particle having a
size ratio of 3 to 1 or greater
to diameter
2 1 micron = approximately .00004 inches
DUP 1012411 DU 053458
f
e Studies since that time led the American Conference of
Governmental Industrial Hygienists in 1968 to adopt as
an
intent
to
change
1 " ,
a TLV of
12
fibers greater
than 5 microns in length per milliliter of air 12
fibers
5 ...or 2 million particles per cubic foot
of air 2 MPPCF instead of the present TLV of 5 MPPCF
see Appendix C The 12 fibers > 5 TLV is based
on the new membrane filter sample method whereas the
2 MPPCF TLV is based on the older less effective
impinger sample method
@ Both the ACGIH and the Division of Occupational Health Department of Health Education and Welfare agree the fiber count method will in all probability replace particulate measurement for exposure to
asbestos dust and will be in the TLV Recommended
category in 1970
e The Construction Division's TLV and the Departmental goal of 500,000 PPCF actually applies to overall dustiness as measured by the impinger method and is not meaningful when the sample is taken by the membrane
filter method The membrane filter remains the best
method of measurement to date and justities its
continued use
findings sampling was being
findings
the
fact that membrane filter
used
used
used
at
Old
Hickory
Hickory
the committee
agreed to change from the Departmental TLV goal of 500,000
PPCF to 12 fibers > 5 ~ in length for instantaneous or
short term exposure one hour or less A
length >5 in
This is 1/2
the
was established for ACGIH proposed TLV
eight
We
TLV of 6 fibers
hour exposure
feel that TLV
goals of 12 and 6 offer as much or more protection than the
original TLV expressed in particles Additionally we are
aligning ourselves in the direction which the asbestos
industry and those in the field of study are taking We shall continue to take additional dust samples and follow
the industry studies
1
The ACGIH leaves their recommendation in a Notice of Intended
Change category for two years If in two years questioning the values
in the Recommended list
no evidence comes to light TLV's they are then placed
2 The ACGIH TLV of 12 fibers based on an hour day
> 5 is a time weighted average
DUP 1012412
DU 053459
III
In the following sample data Old Hickory used for long and short term exposure defined above
ing when respiratory protection is required
the for
TLV's
specify-
Sampling Procedure
IV
Sampling at Old No. 92814 with Aerosol Adaptor
Hickory was done with an MSA portable pump Millipore Filter Assembly No. MAWG037AO and No. XX6200004 All samples were sent to
Dr. Morton Corn
Attention Felix Stein Department of Occupational Health
University of Pittsburgh Pittsburgh Pennsylvania 15213
Dr. Corn is a qualified analysis See Appendix
expert in the field for microscopy
D for actual procedures
Sample Data
In a period May through August 43 samples were taken and
analyzed See Appendix E Of the 43 36 were jobs 7 were sampled at vents Fifteen of the 36 were out of limits
Four or the 15 out
sawing Unibestos one long term
of limits were taken whiie machine
There were three short term samples
and
Of the 11 remaining
5 were greater than
samples 6 samples samples
6
six hours
were
less
than
one hour
and
Following are data of the 15 samples that exceeded TLV's
DUP 1012413 DU 053460
(
)
DUST SAMPLING EXCEEDING TLV's
-
278
weet gates
.
Instantaneous or short term hour > 5 length Long term eight hour > 5 length
or less average
Duration Fiber
Sample
No.
Location and Activity
of
Sample
ML > 5 wit
- 12 fibers - fibers
Remarks
Group 1
25
Central Shops -
20 min
Sawing Unibestos
28
Central Shops -
5 min
Sawing Unibestos
477
_
99
Sawing of Unibestos All samples produced fiber counts greatly exceeding TLV's
30
Central Shops -
10 min
Sawing Unibestos
759
32
Reemay Shop -
1 hr
Sawing Unibestos 4 min
and Kaylo
249
Central Shops
-
Sawing
Dacron Shops -
Sample B - Sawing
Ruberoid
10 min
15 min
Dacron Shops Sawing & Pouring
Ground Asbestos
13 min
42
Dacron Shops -
Sawing Kaylo
7 hr 30 min
19
DMT Shop -
Sawing
15 min
25
DMT Shop - Sawing
10 min
Asbestos Without
Bag Over Exhaust
15
PRL Shop - Sawing 16 min
With Vacuum on Saw
38
27
: .
38
Sawing of Insulation Specific brands of insulation not known All short term fiber counts exceed TLV by
considerable amount
The long term sample 42 only slightly
exceeds TLV
8
925
773
106
DUP 1012414 DU 053461
DUST SAMPLING EXCEEDING TLV's Cont'd
Sample
No.
Location and Activity
Duration of
Sample
Fiber
ML > 5
Remarks
Group 3
39
Central Shops -
7 hr
Routine Work
40
Dacron Shops -
6 hr
Routine Work
;
4 min
7
Routine Long Term
Work includes all types
of jobs from sawing to
13
cleaning Some read-
ings are slightly
. .
41
Dacron Shop
6 hr
greater than two times -
8
the TLV but do not
Routine Work
10 min
approach the levels of
42
Power Maintenance 6 hr
the short term jobs
13
Routine Work
50 min
V. Recommendations
Based on Old Hickory's study of the asbestos dust problem and analysis of the sample data the following recommenda-
tions are made
1. rs The Engineering Standards should specify the exclusion
of insulation materials containing Crocidolite type CK
Use of Unibestos be discontinued and removed from the Ck
Engineering Department Standards
Samples should be taken using membrane filters instead
OK
of impinger type samplers at several plant locations ~
Torit Dust Collector Series 19 or equal should be
NO
specified for use on all power saws used for asbestos
Consider including in Engineering Standards
All existing vacuum systems used for asbestos dust removal should be upgraded to highest effectiveness attainable against air leakage Special attention should be given to bandsaws Consider including in Engineering Standards
"
fl
fl
1 Analyze data to establish relationship to the TLV
This may
indicate relaxing or tightening of requirements Routine
sampling should be done so that dust level control can be
maintained
DUP 1012415
~
DU 053462
6. Torit Down Draft Benches or equal should be specified for use in production type insulation shops where severe
dusting occurs from shaping
asbestos
OME 1.5M-
cutting or handsawing Consider including in
Engineering Standards
7 Approved vacuum cleaners shall be used for floors equip-
ment etc. whenever practical
Investigation is continu-
ing to find vacuum cleaners that will entrap particle
sizes 5 microns and greater efficiently Goal is to
reduce fiber content of the exhaust air
8. Minimum Safety Rules
a Mineral dust respirators approved under U. S. Bureau of Mines Schedule 21B life Appendix F shall be worn
for the following jobs life
1 All sawing of Unibestos until this product is discontinued
2 Pouring of ground asbestos in all cases Examples filling storage bins dumping into mix pails etc.
3 Tearing off asbestos insulation from pipelines
equipment vessels etc.
4
Any operation involving cleaning or removing of asbestos dust or residue in which an approved
vacuum cleaner is not used
(5 ) )
Cleaning
vacuum
systems
and
vacuum
cleaners
handling
asbestos dust
b
An approved vacuum cleaner shall be used to remove
asbestos dust when cleaning floors equipment and parts wherever practical Where impractical an approved
dust mask shall be worn
c On power equipment provided with dust removal systems turn systems on before working on asbestos materials
Turn systems off only after completing work
old Hickory has chosen
96042 filter approved
the MSA Dustfoe
under 21B as a
77 with catalog number plant standard The
Insulation Industry Hygiene Research Program and Manville
Research and Engineering Center are developing and testing disposable masks with the cooperation of members of the Inter-
national Workers
Association Heat and Frost Insulators and Asbestos
Old Hickory will keep Textile Fibers informed on
this development
DUP 1012416
DU 053463
Procedures
All insulation shops must be properly ventilated and
saws equipped with high efficiency cyclone type or fabric filter type dust collectors In order to assure expedient and efficient dust removal the following shall be in
effect
a Specific Safety Rules shall apply
b Equipment and shops shall be inspected once per month to assure systems are being maintained and are operating properly This inspection shall be on the IBM monthly reminder Specific items to be checked
are
1 Dust collector fans operating
2
Seals around ducts are tight to assure adequate velocity and volume of air
3 All duct joints are tight
4
Dust collection containers shall have plastic bags inserted to eliminate need for shoveling sweeping dumping etc. Bags should not be allowed to fill more than 1/2 to 2/3 full to allow for tying the tops of bags upon removal to prevent dusting condition
5
Under normal use of saws average one hour sawing per day the cloth exhaust filter bags should be agitated shaken and beaten each week and
cleaned each six months
6
To clean exhaust filter bags a large plastic should be placed over the filter bag and tied the top Then with the fan off agitate the
bag
at
filter
bag vigorously by beating and shaking to loosen the dust particles from inside and outside the
filter bag Plastic bag must then be removed tied and disposed of Dust inside the filter bag will settle to the bottom These bags can be
used indefinitely by properly cleaning but it is
recommended they be replaced after three years
normal use
DUP 1012417
DU 053464
7
Ducts shall be checked by use of flashlight or other means to assure they are not plugged
8
Room exhausts and wall fans shall be
proper rotation of fan and
grids are not blocked with
to assure trash
checked for
guards or
9
Exhausts and vents
to assure they are
areas
shall be checked periodically exhausting into unoccupied
c Approved dust masks shall be used as specified in Safety Rules and inspected monthly monthly
2- Personnel should be thoroughly trained in how to properly fit the masks or respirators to the face
as per the manufacturer's recommendations
Responsibility
It is the responsibility of the area supervisor in whose area dust collection systems are located to see that they are inspected and recorded on IBM cards according to this procedure
SUMMARY
-
Old Hickory has attempted to pool present knowledge of the asbestos dust problem with the information obtained from plant
sampling to do the following 1 clarify the differences between
level identification - MPPCF and fibers 2 determine realistic TLV 3 identify jobs and materials exceeding TLV 4 reduce exposure by specifying equipment modifications or additions changes in job procedures and use of suitable respirators where levels cannot be lowered sufficiently
The recommendations contained in this report are based on analysis of the problems imposed on the only groups of people on the Old Hickory plant site routinely exposed to asbestos dust the pipe insulators Other job classes and other plant sites may have particular problems which go beyond old Hickory's considerations
DUP 1012418
DU 053465
10
Asbestos dust hazards can obviously be greatly minimized by controlling exposure concentrations to safe levels Old Hickory's selection of a safe level is equivalent to 20 of the present recognized industry standard Further it is believed that the
best way to obtain this level is to control it at the source
thereby reducing the instances where respirators are needed
DUP 1012419 DU 053466
11
\
ACKNOWLEDGMENTS
The assistance of the following individuals is gratefully
acknowledged
-
Oa
C. D. Crook
Analytical
Analytical
Research
2 Peer 7593 7593
Laboratory 8-144-7679 8-144-7679
Old Hickory
Bureau of Mines U.S. Department of Interior Pittsburgh Pennsylvania
Lynch
Bureau of Occupational Safety & Health U.S. Department of H.E.W. Cincinnati Ohio
Murray M.D.
Medical Supervisor old Hickory
Rose
J. R. Smith Felix Stein
Secretary of American Conference of Governmental Industrial Hygienisis Cincinnati Ohio
Chemical Control Laboratory
Old Hickory
Department of Occupational University of Pittsburgh
Pittsburgh Pennsylvania
Health
Tracey
Du Pont de Nemours
Werk Uentrop Hamm West Germany
Deutschland
GMBH
DUP 1012420 DU 053467
APPENDIXES
DUP 1012421 DU 053468
COPY
CC
R. B. Hayden D. D. Drummond
TO
R. J. BLAIR
FROM
J. A. SIGMAN - LYMAN COX
Wilmington Delaware
August 8 1968
CONTROL OF ASBESTOS DUST
The recommended rules and procedures contained in letters
Cockrill me to be
to Drummond dated 3/29/68 generally satisfactory but
and
are
Rhodes to Kennedy seem to not complete in certain
respects The additions that I think should be considered are
outlined below
1. A goal level should be stated The Threshold Limit Value
recommended by the American Conference of Governmental
Industrial Hygienists is 5 million particles per cu ft of
air cles
Construction has set a goal of 5 hundred thousand parti-
per cu ft of air
Both values are average concentrations
for an hour working day
I think we should use the same
goal as Construction
2 A procedure for monitoring the level of exposure should be
established
insulators
insulators
insulators
insulators
wear wear
sample is collected
Construction does this by having one of their
dust sampler for an hour day
One such
once
once
a
month
a month
at at
at
cach
construction
construction
construction
construction
construction
construction
site site site site
site
The
filter
through
which
the
air
sample has been
drawn
drawn
is is
sent to Dr. Morton Corn at the University of Pittsburgh for
microscopic to Queener
examination
See
dated 5/29/68 We
attached
could do
copy of letter Keuper the same thing
However I suggest that we learn how to do the microscopic
work ourselves This is something the Old Hickory laboratory is trying to do A method for collecting and examining asbestos
dust samples was published in the Journal of Occupational
Medicine dated January 1968 by Lynch and Ayer The title of
their paper is Measurement of Asbestos Exposure If this
article doesn't provide enough information it might be
advisable to to visit Dr.
arrange for someone from the Old Hickory Corn for instructions His address is
Laboratory
Graduate
School of Public Health Department of Occupational Health
University of Pittsburgh Pittsburgh Pennsylvania 15213
DUP 1012422 DU 053469
COPY _
3 The procedure discussed above in item 2 should be used to
determine whether or not our control methods as outlined in
Rhodes letter of May 22 are good enough to hold dust levels
at values such that the hour value is not likely to be
exceeded This at The values
is something else that old Hickory is working
obtained in this way will show whether there
are specific operations or activities that cause enough dust to require additional control or the use of protective equipment air masks or respirators I would think we would devise
control measures in preference to specifying protective equip-
ment
If we find that we can't do this we will have established
a basis for supervisory judgment for saying what dust condi-
tions are sufficiently severe or irritating to require
protective equipment In my opinion if we find that we want
to adopt a safety rule respirators it should
requiring the wearing of dust masks or apply to any dust that is severe or
irritating not just insulation
dust soda ash activated carbon are handled on the plant
dust This might be coal or other dusty materials that
4 The procedure should outlaw materials containing crocidolite type asbestos In this connection the Purchasing Department .says we haven't been buying any products containing crocidolite
5.
The
The
procedure
procedure
should
should
should
contain asbestos
outlaw
outlaw
pressure
pressure
sprayi spran yingg spraying of spraying of
materialsmaterialms aterials that that
materials materials
that
6 A record should be compiled to show dates on which improved control measures were instituted e.g. when specific saws
were equipped with exhaust systems when protective equipment was provided when specific instructions on mixing asbestos cement were established etc.
7 Medical records that Dr. Murray has compiled on personnel who
work as insulators should be continued
The interest commendable
which When
Old Hickory is showing in they gain skill in taking
the subject is dust samples and
measuring concentrations accumulate meaningful data on the amount
of dust produced by identifiable devise improved control methods
operations or activities and they should be assigned the
responsibility for taking the lead in applying findings to other
Textile Fibers plants and if it seems appropriate suggesting additions to the present Engineering Standard S2T which is on
Threshold Limit Values of Air Contaminants
LC'rbl
Att
10-17-69
a
DUP 1012423
oo
.
DU053470
COPY
CC Lyman Cox
Wilmington Delaware August 16 1968
O. W. HESSfiMANAGER
OLD HICKORY PLANT
ASBESTOS EXPOSURE HAZARDS
Ref Letter B. F. Kennedy to R. J. Blair of 5/27/68
The reference letter pointed out Old Hickory's concern on the adequacy of present safety standards for employees exposed to insulation dust Old Hickory suggested that a departmental standard be set up requiring respiratory protection for employees working
with insulation
I have reviewed this proposal with the Division Engineer's
Office who in turn have ment Haskell Laboratory
counseled and other
with the Engineering Depart-
locations We conclude the
following
1 Basically there is little technical knowledge today on level of exposure that is tolerable Accordingly
there is considerable debate on what standards should
apply to dust exposure
2 There have been many recent changes in the direction
of minimizing personnel exposure For example pre-
formed insulation outlawing of crocidolite insulation dust exhaust systems etc. The effect of these improvements are not quantitatively known
Accordingly before adopting a standard requiring respiratory protection across the board a significant administrative problem we should obtain some quantitative facts of where we stand today I would like for old Hickory to take the lead in making this analysis and in turn give guidance to the department
DUP 1012424 DU 053471
2 '
-
-
Specifically Old Hickory should first assure itself that
it is in conformity with all the latest operating and procedural
standards and then under these conditions measure dust concentra-
tion at the various identifiable operations including not only
insulation dust but coal carbon and other dust sources This
will require developing techniques for sampling and measuring dust
concentration Some thoughts along this line are contained in the
attached letter from Lyman Cox Then let's judge our actual
position
standard standard
of dust concentration in various operations against a of 500,000 particles per cubic foot of air This is the recently adopted by Construction and is tenth of the
official Governmental standards From these data identify the
problem areas of dust concentration exceeding the standard These findings should be made known to the department and used as criteria for adopting respiratory protection at Old Hickory and other plant
,
locations
with
Also your medical section should continue its insulators so that a continuing medical history
for correlation with procedural equipment changes
follow
is available
Old Hickory's concern in this area is justifiable and I believe with the above approach we can more realistically establish protective equipment standards Please advise if you have any questions
DACRONfiMANUFACTURING DIVISION
bhs
Attach
10-17-69
s J. BLAIR
PRODUCTION MANAGER
DUP 1012425 DU 053472
ee EB |
ee:
ees
eee
COPY
CC
J. S. G. J. E. C. F. H. B. B. H. D. C. R. K. W. C. G. L. R. J.
Queener Employee Rel Nemours
Stopps M.D. Employee Rel Haskell
Jones Purchasing Louviers
Mackie
Lewis
Boyce
Lang
Mason
Engg
It tt "
Constr
14
IT
11
0
Louviers
15 1 11
Weaver " # 1
Dorsch 11
t
1
Ham "
"
00
C. J. Lawrence Jr. Engg Constr Louviers
W. H. Zane Engg Design Louviers
J. R. Allen Engg ESD Site Safety Supervisor
Louviers Constr
Wilmington Delaware April 5 1968
FIELD PROJECT MANAGERS
F. C. BAYLIS ASHTABULA W. S. BRIGGS BEAUMONT J. J. BELL BREVARD A. D. DAY CAPE FEAR C. S. ANDERSON CHAMBERS WORKS W. S. FREE CHATTANOOGA H. S. STANTON JR CIRCLEVILLE W. G. HARRIS COLUMBUS SHOPS
M. W. HARTNETT JR EAST CHICAGO W. C. MANNFAR FLORENCE
K. G. CAUGHMAN JR HOUSTON
~
R. H. DAVIS KINSTON R. G. STERNBERGER LOUISVILLE J. K. ADDISON MARTINSVILLE W. A. SAMANS MAY
SAFETY - DUST CONTROL
A. S. TRUMPORE MEMPHIS
W. BLAKE MOBERLY
H. F. REDMILE OLD HICKORY
W. S. LEWIN PARLIN
F. H. FOWLER AFPM PONTCHARTRAIN
E. M. VASS SABINE RIVER
H. J. FEINEN SAVANNAH RIVER
Te _
E. K. DRAWDY SEAFORD
R. A. MINIARD SPRUANCE
S. V. HINSON VICTORIA
R. L. SPITZ WASHINGTON WORKS
S. KREWATCH WAYNESBORO
G. E. BARLOW JR WILM AREA
J. R. BALDER MGR WILM SHOPS
7
Industrial work producing airborne dust particle contamination is recognized as a primary contributor to employee health problems The ability of the medical profession in identifying the personal respiratory disease of asbestosis and the establishing of the
cause to be due to extended exposure to asbestos dust have created
a serious industrial concern Federal and State legislation is being enacted to place the burden of proof on the employer for continuous conformance with Governmental Industrial Hygienists established Threshold Limit Values for specific materials The employer's problem becomes acute when employment medical examinations are not required for the employees
DUP 1012426 DU 053473
COPY
With the mentioned responsibility in mind and to assure atmospheric conditions which will not contribute to the employees health problems when working with asbestos fiber containing materials the Construction Division is initiating the following permanent air quality control program to be effective June 1968
Air Monitoring
Environmental air monitoring shall be conducted to provide quantitative data for site evaluation of dust control efficiency and document air quality analysis needed to demonstrate conformance with established Threshold Limit Values TLV
1. The Threshold Limit Value for total dust count shall be 500,000
particles per cubic foot of air
2 Personnel monitoring will be conducted in the insulation shops on site locations One employee will be requested to wear the air sampler one eight day each month
3 Trained site safety personnel shall be responsible for the
control operation and adjustment of the air sampling instru-
ment recording required technical data associated with the
-
air sample mailing of air sample to laboratory for analysis
and compiling records of analysis reports
.
when soliciting participation in the air monitoring program
craft supervision and Safety Engineer should anticipate who
will be involved in work which will produce the greatest dust
exposure for what day of that month
5 The personnel air sampling instrument used shall be a Universal Industrial Equipment Company Millipore filter Model 440B qualified for explosion hazard areas air sampler The filter used shall be a .8 micron pore size Millipore Cat No. MAWG 037 AO Type AA in plastic holder This equipment will be assigned to the sites where air monitoring is required by the Division Safety Office
DUP 1012427 DU 053474
COPY
3
f
\
6 The filter in plastic holder upon completion of air sampling
shall be mailed by the site Safety Engineer to Morton Corn
Ph.D. Graduate School of Public Health University of
Pittsburgh Pittsburgh Pennsylvania 15213 attention Felix
Stein A phase microscopy analysis of submitted sample will
be made and a
Safety Office
report submitted to the site and the
indicating a fibers below 5 micron
Division
length
b fibers above 5 micron length and c total number of
particles Reports indicating total particle count to be
approaching or above the TLV will require determining cause of condition and taking corrective action to reduce particle count After improvement been applied a second eight sample shall be conducted analyzed and documented
Atmospheric Dust Control
The application of the following
conformance with the established dust emission control
recommendations should demonstrate
dust TLV and provide effective
1. Materials containing Crocidolite asbestos fiber shall not be
purchased or accepted for use Materials containing Chrysotile
-
and Amosite asbestos fibers are acceptable for use
2. pressure spray application of materials with any per cent
of asbestos fiber content shall be eliminated
3 All power tool and equipment operations shall be isolated from
other shop facilities and fabricating operations
4 All power shop equipment shall when operated have installed
exhaust ventilation of sufficient capacity to remove dust particles at point of origin Exhausted dust particles shall
be collected by an effective collector system which will not allow vent of dust particles to the atmosphere
5 Present controlled shop cleanliness programs shall be expanded A vacuum cleaner should be used in lieu of broom sweeping to remove dust particles from shop equipment work tables ledges floors etc.
6 A controlled materials handling program should be adopted to eliminate the emission of dust for example when opening and removing materials from shipping cartons or in the handling and mixing of asbestos cements
DUP 1012428 DU 053475
COPY
Respiratory Protection
Severe or isolated conditions may require that respiratory protective devices be used Consideration should be made for adequate protection of people in adjacent areas to the work location producing this condition A supplied air respirator or a filter respirator manufactured by Mine Safety Appliance Co. Pittsburgh Pennsylvania Model Dustfoe 77 with filter number BM 21 97
should be used
Your usual cooperation is anticipated in administering these dust
controls
CONSTRUCTION DIVISION
s E.
DIVISION
KEUPER SAFETY
SUPERINTENDENT
KEK 10-17-69
DUP 1012429 DU 053476