Document jy0q4akjaxoxqbY8k8aDJgm0Z
111: K
J:V:_UUMU
INTERNAL CC;nE5?ONCeNCc
FILE COPY
A.L'D .~LASTICS
P 3CCXX 5361. SOUTH CHARLESTON. WEST V.'RG.'NIA 2.5303
Mr. W. T. Shelton 704 Shop
Mr. G. F. Hurley Mr. G. C. Merz Mr. M. E. Perry Mr. H. L. Robinson
February 13, 1979
: - Technical Center IH/EP
Covering Reactors with Asbestos Paper
AO
'X' I1'
PROJECT
Survey for asbestos exposure of insulator covering
two small reactor lids with 32-pound asbestos
paper. Covering manufactured by Johns-Manville.
DATE OF SURVEY February 7, 1979
DISCUSSION
It is common practice to cover small reactor lids
with asbestos paper to protect operators from
burns. The reactor lids are stainless steel and contain heating
elements and are operated at elevated temperatures. When cooling
the reactors the lids are removed. As a result of frequent handling
the asbestos covering is abraded and must be replaced periodically.
Mr. J. R. Monin was monitored for asbestos exposure during the covering of two of these reactor lids.
The exposure was well below the TWA of 2 fibers/cc and a ceiling value of 10 fibers/cc.
RESULTS Location 770 Shop
Personnel J.R. Monin
Sampling Time-Min.
20/2 LPM
Exposure Fibers/cc > 5 pm
0.24
RECOMMENDATIONS Painting the reactor lids with VIMASCO after covering with asbestos paper reduces the rate of
abrading and the distribution of asbestos fibers into the workplace.
UCC 024288
Mr. W. T. Shelton
2
2/13/79
REFERENCES
Volume 38C-29X4-Rla Asbestos Dust Determination by Membrane Filter Technique Using Phase Contrast Microscopy.
REPORT PREPARED BY
G. W. Bott Technical Center Industrial Hygiene Group
APPROVED BY GWB/sc
UCC 024289