Document jwn9wZ64G2EwBzkB46X1gdmZ
TO
I
IVI IP I ft
26 Ui January, 1970
AU0C1.iI)if - v.wiiiO^irNYAti c\iAv\::.vnN. STATUiSf iiviroTFi1 or nni;nvR'.\~Hri'T)irs - *
23 January, IV/O JIAV/Jii
it.A. jlAMTH, lUuibon D.S. .Il'iJON, Prusrels
UTCll.Mit), Sl-f I.ouj s
J .V. f 1 JarreIt, London
)1,N. PchLsiroeui,
V] s
J,C, barrels, London
K.V* IVoekoy, )>ru.;soiN
IV.I). Topagcorgo, St.. Louis
7O
7
1. n:
l^rlhcr work has coni'jriiiod Hint, in the presence of binhenyJ, gome of tin I'.C.H. isomers arc degraded biologically by hi plumy l~nduptcd micro-organisms. In particular, 2-V-di cblorobj phenyl appears to bo readily degraded. With /.rodor 12'i2, peak 1, which probably corresponds to 2,>j '-dichlorobiphonyl, virtually disappears in o low days under similar conditions, mid peak A, which probably corresponds to o mixture of tri- mid totra- chi ori somers shows significant' degradation, but does not disappear completely. Attempts to degrade 2-A'-dichloroljphonyl, using synthoti c sowngt instead of biphenyl have not so far been successful.
2. N<] wport Plant.
Analysis of effluent samples from the Newport plant have shown llml P.C.JVb (measured an Aroclor 32A2) were present at levels up to about 300 parts per billion (10^). Investigation also revealed that P.C.H,'s were promgi t in surfneo drainage which by-passed the main effluent system. Steps have been token to re-route some surface drains so that Aroclorcontaiiinnted drainings are intercepted by the interceptor pit. Some modifications are in hand to improve the effectiveness of the interceptor pit and tic Analytical Department at Newport is being equipped to measure Aroclor in the effluent so. that effective control of the situation can be ewtnbl inhed. It hufi been tentatively agreed that a maximum level of 10 parts* per billion (mensvred as Aroclor 1242) will be the plunt effluent goal. Samples will be token and analysed on a daily basis.
Analyses of water in the vicinity of the solid waste disposal site near Pontyjridd did not reveal significant quantities of P.C.Il. Newport Analytical will cheek on this site from time to time, but present indications arc tlpit this is not a significant source of pollution.
llud samples from the Severn Estuary, analysed at itunbon, showed levels of P.Q.D.'s (l2V2) comparable with those found in earlier measurements at St. Louis, vi/. 1-2 p.p.m. These levels will he chocked by Newport Analytical at monthly intervals.
MON3 04S231
Tho level of P.C.H.'s at t)ie top of the interceptor pit lm been
determined at weekly intervals. This appeared to fluctuate up to about
13 p.p#M. Newport Analytical will continue to sample and analyse at weekly
intervals to establish a basis for regular cleaning and disposal of Aroclor
waste from the interceptor pit,
*
Technical Visits and Discussions.
A mooting 1ms now been arranged with representatives of the Ministry of Agriculture!, Fisheries and Food (Fisheries Laboratory) for January 27th to discuss tlnj implications of finding P.C.B.'s in wild-life, particularly marine.
Infornntion from the Salmon and Freshwater Fisheries Laboratory of the same Ministry itdicutcs that Aroclor 1262 is not toxic to Harlequin fish (itnspora hetcrotuorpl a) up to & concentration of 100 p.p.m.
Tests Join Ituinbow Trout (Snltno guirdnerii) with Aroclor 1262 showed no mortalities nfter five weeks, but after six days the fish had accumulated the Aroclor up|to u concentration 100 times that of the aquariu. Figures for the concentration of Aroclor in the water were not given, but were presumably effectively that of saturated solution, viz. 30-100 p.p.b.
4, Liaison with Payer, Prodclcc and Onffnro.
Meetings with Layer and Prodclcc have resulted in a greater awareness of tho problem by their managements. They seem willing to co-operate to establish a common basis for dealing with the pollution problem, A meeting of till European producers is being arranged for February 9/10 in Frankfurt, at which Monsunto will make a presentation summarising tho technical knowledge available and discuss the need for education and positive action in dealing with customers.
5. HiCjlL Disposal at Customer Plants.
Analyses of samplea from effluent at the N.C.U. emulsion plant nt llorchnm lVd liovo sliown quite high levels of Aroclor 1242. The mud in the stream taking surface water druiiage contains 130 p.p.m.
This jrnblcm will be discussed with N.C.U. on 26th February,
B.I.C.C, have informed us that they wish to instruct their customers on hmv to dispose of Aroclor-imprognated capacitors. We have boon shown a draft of their proposal fer comment.
HONS 0<a232