Document jokyvV8BOJ64NzLOaD86xmbp
8 tr
October 16, 1974
Legal Sacttoo Industrial Commission of Ohio Ohio Departments Building Columbus, Ohio 43215
Attention: John R. Allen Room 419 B
Re: 0.0. 162314 John Koch Is
Centleaen:
On September 10, 1974, a visit vas made to the plant of Foseco, Inc., Cleveland, Ohio to check conditions under which the claimant had worked.
The company nanufactures hot tops and heating systems for steel Ingot solds, and aetallurglcal chemicals for natal neltlng and foundry In dustries.
According to company records, the claimant's experience Is as follows;
5-8-72 - 8-1-73 8-1-73 - 9-19-73 9-19-73
Machine operator. Including pulping machines Salvage operator Permanent layoff
Pulping is done In rows of vertical cylindrical blenders. Dry material is charged Into the blenders, mixed with water, and later cast Into products such as hot tops. The component* Include asbestos, fiberglass, silica, clay, rock wool, sod phenolic resin. Some machines have hoods with local exhaust to serve as dust collectors, but not all do. Operators are required to wear dust masks approved by the Bureau of Mines for as bestos and mineral dusts. The type used was Xo. 8710, supplied by the 3M Co.
Maasuressanta tere made In the bresthl-g zona of operators. Data are summarized in Table 1. from an air sample teken with e midget liquid implager, the dust count wes 2.3 million particles per cubic foot. A sample of settled dust wes taken for X-ray diffraction analysis of free silica content by Kettering Laboratory at the University of Cincinnati. The result vas 451 free silica in the fora of alpha qumrtr. From this, the Threshold Lialt Value (TLV) for lmplnger measurement, computed froa the fonmiln TLV * 300/ (1 S10R + 10) appef. Is 5-5 appuf. While below th* TLV, the 2.3 appef dust count wes higher tb'-n desirable for the high -
illce content.
2877
I ______ U <----- m -- > --
-I-
*Measurements were asde with 37 an. Type iX eeeferane filters sad * personal iuplU| pup won by tbo operator. These won taken open face, without cycloat, thus sampling tho total dust to tho sir. Por this nothod, cho TLT for stiles dust, coaputsd fro* cho foraula TLV-30/(X SlOj + 3) ag/M3 la 0.63 aillijrsoa per cubit ostor (ag/M3). Tho saw typo of fllcsr Is uaod for asking couscs of ssbostos fibers with s phase cooeraet Micro scope. The TLV for asbestos Is 3 fibers longer than 3 Micron*, per cubic ceotlaatar of air (3 f> Su'ce).
The fine filter, which bad saaplad aa air voluaa of 73 liter*, had tr>o heavy a dust accumulation for count of fibers, by weight aaasurnanoe, the coMcaatratlOM of total dust, including both respirable and non-resplr> able particle slsca was 42 ag/M3, which is far above the TLV of 0.63 Mg'.'t3.
from the second filter, the saaple sice of which was 13 liters, analysts for fiber count was aede by Kettering Laboratory at the University of Cincinnati. The result was 58 f > 5u/cc, which la Mich greater chan the 3 f > 3u/cc TLV. The concentration of total dust oa this filter was 6f ag/U3
It should be noted that the fiber eount Includes not solely asbeatoa, but all types In Che saapla. The slurry Material Included fiberglass and rock wool, which would both be classified as amorphous silica, the TLV being 20 appef. By ratio, this would be equivalent to 7 ag.'MS. Hooever, it vis evident, froa the relative quantities used, that asbestos was a slgnlflcent portion.
Threshold Limit Values are not intended for use, or for Modification for use, aa proof or disproof of an existing dlsesse or phyelcsl condition.
Symptoms of silicosis and asbestoalt do not usually appear until after a ouaber of years exposure, although there are difference* in Individual susceptibility. If, In aplte of the high duet and fiber concentrations, the required filter aeska were used properly. It Is not likely chat excessive exposure would occur. Whether the claimant has symptoms related to such exposure would be a medical quest loo.
Very truly yours,
ttHssch
Lobert V. Burst*, P.t. Industrial Bygleoe Engineer
2878
Heaauremenca a t Foaeco, I n c . , C le v e la n d , Ohio September 10, 1974
DCPJUrrutMT Of eNVIAOMMOITM. MCM.TM unuuno kAOAATO*V BID (T7-OT00
Re: Material:
Submi tted:
Required:
O.D. 162314, John J. Kochis
Two (2) filter papers containing particulate matter removed from the atmosphere at Foseco, Inc., Cleve land, Ohio.
9-25-74 by Mr. R.W. Hursh, Industrial Hygiene Engineer, Industrial Commission of Ohio, Division of Safety & Hygiene, P.0. Box 1745, Columbus, Ohio 43216
Count of fibers greater than 5 microns/cc of air
Analysis Number
74A-4182
74A-4183
Sample Number
*3
14
Results
Volume of Air Cubic Centimeter
76,200
12,700
Pibers ' *
58
This sample was too heavy with particulate to make a fiber count.
2880
David W. Ye ageif, SaLhior Research Associate of Environmental Health
Reported: 10-1-74
6
University of Cincinnati Medical C
3223 Eden A Cincinnati, Ohio
WMrrutMT of DWWOIMMTM. MM.TM
KcmiitMo uOMATOv
am R4jo#
Re: O.D.
162314, John J. Kochis
Material:
One (1) settled dust sample collected 9-10-74 at Poseco, Inc., Cleveland, Onio
Submitted:
9-25-74 by Mr. R.W. Hursh, Industrial Hygiene Engir
The Industrial Commission of Ohio, Division of Safe & Hygiene, P.0. Box 1745, Columbus, Ohio 43216
Required:
Dete aination of per cent free crystalline silica in tute particles less than 5 microns
Analysis Number
74A-4184
Results
Per Cent Pres Crystalline Silica in the Particles
___________ Less Than 5 Microns in Diameter
q Quartz
Cristobalite
Tridymite
45
absent
absent*
\
David W. Yeager, ^fenifor Research Associate of Environmental Health
Reported: 10-1-74
STATE OF OHIO
THE INDUSTRIAL COMMISSION OF OHIO
DIVISION OF SAFETY AND HYGIENE aaas wear Firm avcnuc f.o. mox n* cocumsus. OHiomHi aaais
4*43M
taoQYMjl *mmastics
MUCVkUaOcfmTtIMf.inNCM.
JOHN C SOW
JOHN X QIUJQAN OflWMf
September 19, 1974
iMy M KfF OiMwtrnam. sa*wvawcnca wnxuM c. wuffmv
` - : Ciairiwumm
teetering Laboratory University of Cincinnati 3223 Eden Avenue Cincinnati, Ohio 45219
Gentlemen:
Enclosed are two aaaplea taken on Milllpore Type AA, 37 ami., membrane filters at a pulping operation of Foseco Inc., Cleveland, Sept. 10, 1974, data on which are:
Sample Ho. Sampling Time. Min. Rate, i/m Air Volume. Liters
9/10/74 #3
30
2.54
76.2
9/10/74 #4
5
2.54
'
12.7
Counts of asbestos fibers are needed. The 5-minut sample was taken In ease dust accumulation on the 30-minut fileer may have been too heavy to permit detection of fibers. Return of the unused portions of the filters would be helpful.
Also enclosed Is a settled dust sample for analysis by X*ray diffraction of free silica in the portion smaller than 5 microns.
The above tests should be billed to the Bureau of Workmen's Compensation. The claim number is 0.0. 162314, John J. Koch la.
A second settled dust sample for similar free silica analysis of the por tion smeller than 5 microns was taken at the Arcalr cutting operation of Crucible Steel Casting Co., Cleveland. This should be billed to Workmen's Compensation, the claim number being 0.0. 162264, Johnny L. Eberhardt.
A third settled dust sample for free silica analysis was taken at a sand blast operation at Club Products Dlv., Standex Inti., Cleveland. This should also be billed to Workmen's Compensation. The claim number is 0.D;.161590, Timothy Canczar.
Forms for the billing are enclosed.
Left hear ft
Tours very truly,
TZ-rfoisC Off ^ Robert W. Hurah. "* ' Industry
2882