Document jmyNeRbMLM7dqVekywxgY5bG9

AKZ2G - BIODEGRADATION (BOD/COD) TEST SUBSTANCE Identity: A mixture containing perfluorooctanesulfonate, which may also be referred to as PFOS, FC-95, or as a component of FC -201. (1Octanesulfonic acid, perfluoroalkyl sulfonate salts (5) + (5140P)) (CAS # 2795-39-3) Rem arks: The 3M production lot number was not noted. The test sample is FC-201. Its purity was not sufficiently characterized, though current information indicates it is a mixture of 6% PFOS, 36% diethylene glycol butyl ether, 36.44% water, 12% Sultone foamer, 9% sodium octyl sulfate, 0.5% sodium lauryl sulfate, and 0.06% benzotriazole. The following summary applies to a mixture with incompletely characterized concentrations o f impurities. Data may not accurately reflect die biodegradability o f die fluorochemical component in the test sample.. METHOD:_____________________________ ___________________________ Method: Not noted. Type: Aerobic GLP: No Year completed: 1975 Contact time: 20 days Inoculum: Source not given. RESULTS ________ ___ Chemical Oxygen Demand (COD): 1,040,000 mg/L Biochemical Oxygen Demand (BOD): 5-Day: 10-Day: 15-Day: 20-Day: 188.000 mg/L 637,500 mg/L 615.000 mg/L 660.000 mg/L C O N C L U S IO N S No conclusions given. Subm itter: 3M Company, Environmental Laboratory, P.O. Box 33331, St. Paul, Minnesota, 55133 000163 DATA QUALITY Reliability: Klimisch ranking 4. Only a summary of results was available. Study lacks description and records of the method followed. The inoculum is not properly characterized. There is no characterization of the test substance purity, and the study lacks analytical confirmation of the amount of fluorochemical proportion in the solution. R E F E R E N C E S ________________________________________________ The studies were conducted the 3M Company, Environmental Laboratory, St. Paul, MN, Lab Request number 2563,1975. OTHER________________ ______________ . ~ ___________________ Last changed: 6/26/00 000164 Ref: ENVIR. ASSESS. INQ. PRODUCT: PRODUCT ECOLOGICAL ASSESSMENT REQUEST FOR LABORATORY WORK DIVISION LAB REQUEST NO. REQUESTER - Name: V iiX t Request Date: Project No.: Code N o .:_ Sample Date: __________ Phone No. P t f 3 /' l l / ~Z __________________ Prob. No. g r p ______________ ___________ Date Needed: t /3Q Description:_______________________________________________________ Purpose of Tests:___________________________________________________ LAp U H A IU nY Date Received Sample: Analyst: Date Completed:. / / * Z / ? Y ~ Hours Spent:___ Y 7~S~ Bn p-2 ^ 1 Please Call Requester If Delays Are Encounte id. PHYSICAL & CHEMICAL PROPERTIES Heatof Combustion Cal/G (BTU/Lb.) Density Ash Other / 'f c iL o r " -- -- P C Z 3 PC E_r Pc WATER POLLUTION pH COD bod5 BOD, Ultimate TOC GC Oxygen Uptake Dehydrogenase Activity (TTC) Other -- ' i.o 4 o p o o '/2 . b o o <065 0 ; O T 6t< / ; O O 70 0 o 7* 9 io o o - /< s /^ o >< -- 2C&.O t-- * 2*7'.O1 ___. ZTd.t BIOASSAY Specify Organism and Method: ^ ( irw c LEACHATE FROM LEACHING TEST pH COD bod5 BOD, Ultimate TOC GC Bioassay Other OTHER Bioaccumulation \ Persistence Degradation Products Recyclability Burnability Weathering r 00 16 ^