Document jmoqoz77kvoMBRdRX8E4kpvYk
HEATING VENTILATING AIR CONDITIONING GUIDE 1942
Table 3. Drying Time and Conditions for Representative Materials3--Con.
Material
Temperature Deg F.
Per Cent Relative Humiditt
Dtma Time
Terra Cotta (air drying in conditioned room)........ Tobacco leaves............ ....................................................
250-300 150-200 85-130. 180-200
110 110-140 120-130
120-130
120-130
Vitreous Enamel sheets before firing................... ..
Wallboard fiber insulating, roller type drier. .........
Walnuts.............................. ----------- --------------------- --------------------- i Wheat, corn, oats, rice, barley---- --------------------------
Wool
U....................................................................
170 300 300-385 300-385 100 , 180 200 105
35 25-35 35-40
35-40
35-40
12-96 Hrs .12 Hrs 12 Hrs
5-7 Hrs
Overnight . 6-8 Hrs -f 2 Hrs acclima tion
16-18 Hrs + 4
Hrs acclima tion 20-24 Hrs + 4 Hrs acclima tion
15-20 Min 2)4-3 Hrs
24-48 Hrs 24 Hrs
20 Min
See references at end of chapter.
the common constituents of fuel are shown in Table 4. The heating values of oils are shown in Fig. 7. The sensible heat in Btu contained in the products of combustion of an average fuel oil and various gases is given in Fig. 8. The problem of securing complete combustion in a heater is important, in order to secure efficiency and the absence of soot formation, but unlike the ordinary power or heating boiler-,-excess air need not be maintained at a minimum in most cases. Excess air is generally admitted either in the heater or before the products go into the drier.
DESIGN
In all drying problems, data regarding temperatures, time, and hu midity must be obtained by experiment or previous experience. Experi ments are best performed at the temperatures, humidities, and velocities to be actually used in the full sized drier, and with full size samples.
The following nomenclature and explanation of terms will be used in the discussion of drying calculations:
H -- humidity of air, pounds of water vapor per pound of dry air. G = pounds of dry air supplied to the drier per unit of time. 5 = pounds of stock dried per unit of time in a continuous drier. 5' = pounds of stock charged per batch to a discontinuous drier.
0 = time. Q - tAtal heat supplied to the drier.
CHAPTER 41. DRYING SYSTEMS
t = air temperature.
I1 = stock temperature.
I" = average stock temperature over short time interval, in a batch drier.
Iw = wet-bulb temperature.
s' = specific heat of the stock.
B = total radiation and conduction losses per unit time,
to = pounds of water per pound of dry stock,
r = heat of evaporation of water.
s = humid heat of air, 1 F.
heat necessary to raise 1 lb of dry air + H lb of steam
Subscript (1) designates conditions at the point where the material in question (air or stock) enters and (2) where it leaves the drier.
Air driers may be divided into two classes, those in which all moisture evaporated from the stock leaves the drier as vapor in the effluent air, and those in which part or all of the moisture is condensed from the air in the drying equipment itself. In any continuously operating drier of the first
type the relation between moisture content of the stock and. quantity of air required for the drying operation is given by the equation:
G (Hi -- Hi) = 5(to, -- w,)
(2)
Table 4. Gas Combustion Constants3
Heat.op es Combustion
Lbs per Lb or Combustible
JiGas
ii
per Lb
per Lb
Required for Combustion
Flue Products
OH
Gross Net
Oi
A'. Air COi
tfi
Carbon
c 12.000
14.140 14,140 2.667 8.873 11.540 3.667
8.S73
Hydrogen
B, 2.015 187.723 61.100 51,643 7.939 26.414 34.353
8.939 26.414
Oxygen
Ot 32.000 11.819
Nitrogen
N, 28.016 13.443
Carbon Monoxide CO 28.000 131506 4,369 4,369 0.571
1.900 2.471 1.571 ....____ 1.900
Carbon Dioxide
COt 44.000 8.548
Methane
CHi 16.031 23.565 23.912 21.533 3.992 13.282 17.274 2.745 2.248 13.282
Ethane
C,Ht 30.046 12.455 22.215 20.312 3.728 12.404 16.132 2.929 1.799 12.404
Propane
C,B, 44.062 8.365 21.564 19,834 3.631 12.081 15.712 2.996 T.635 12.081
Sulphur Dioxide
SOt 64.060 .5.770
Water Vapor HiO 18.015 21.017
Air 28.900 13.063
All gas volumes corrected to 60 F and 30 in. mercury barometric pressure dry.
753