Document jmn0wB7ZM4q7dO1z09pbDMrx5

PLAINTIFF'S EXHIBIT DOW-1296 THE DOW CHEMICAL COMPANY MIDLAND DIVISION July 28, 1969 o9~ -*J. H. Scovic cc: R. G. Carlson D. D. Deline A. C. Wilcox INSULATION MATERIALS The Productivity Committee has reviewed your letter of July 24 with the attachments that outlined some of the economic considerations comparing Aircell asbestos Insulation with Fiberglas. It is clear that we have not only a significant safety advantage with Fiberglas but an economic advantage as well. We strongly support your pursuing the necessary communication program within the Mainten ance organization that you suggest and taking positive action steps to discontinue the use, wherever possible, of asbestos Insulation. W. H. Fletcher rur uiev Productivity Connittee dmf ST0000302 MIDLAND July 24, 1989 THE DOW CHEMICAL COMPANY ST0000303 J. M. Scovic Manager of Services 47 Building INSULATION HAZARDS AND MATERIAL REVIEW (ECONOMIC PHASE) The prime objective in developing our program on insulation hazards and materials has been to correct a potential safety hazard we may have.- Attached you will find an economic analysis. This analysis is in much greater depth than we intend to prese- t in our communications program as part of the formal agenda. This economic information has been gathered mainly for background information and will be used to answer economic questions which I am sure will arise. I might at this point say a few words about the attached exhibits. Exhibit I is a letter written by Roy Anderson which is intended to be mailed out to the production representatives after they have attended our communications meeting. The objective of this letter is to reinforce our opinions on the merits of the various insulation materials. Exhibit II is a simplified, straightforward, hypothetical cost comparison. # Exhibit ID is the backup data used to develop the figures in Exhibit II. We have a factor in the economics of comparing insulating materials which we have previously not examined closely which is the thermal conductivity coefficient. The k factor for Aircell is .61 while the k factor for Fiberglas is .29. Over the years Aircell insulation has been grossly misapplied. The top temperature limit for Aircell is 200F. In order to have a working system we have found that additional steps have been taken to make up for this thermal conductivity coefficient deficiency. One that is commonly used is the wrapping of the pipe and tracer with aluminum foil prior to installing the Aircell. A second method which is commonly used is a: ilying Thermon heat transfer cement on the tracer to more evenly distribut; .he heat. By using the proper insulation such as Fiberglas, the need for jse extra steps could be eliminated. The cost of these extra steps ce: .nly must be taken into consideration when comparing Fiberglas and Airct . I insulation. 1 J. M. Scovic - 3- July 24, 1969 Please feel free to contact me on any further questions you may have. T. J. Madden Maintenance Manager Agricultural Chemicals Production Organic Chemicals Production 222 Building Phone 6-2225 TJM:rb Enc. 0 ST0000305 C INSULATION ECONOMIC ANALYSIS AIRCELL VS. FIBERGLAS . EXHIBIT I EXHIBIT 11 EXHIBIT HI EXHIBIT TV EXHIBIT V Roy Anderson's letter to Plant Supervision on insulation alternates and applications Summary of comparative Insulation costs on a hypothetical job , Detailed labor and material cost comparisons Aircell insulation usage and material costs of A ireell vs. Fiberglas Theoretical heat loss comparison between Aircell and Fiberglas insulation ST0000306 MIDLAND July 24, 1969 EXHIBIT 1 Page 1 of 2 THE DOW CHEMICAL COMPANY s T0000307 INSULATING MATERIALS AND ALTERNATES We are principally concerned in this discussion with materials which may be substituted for some of our existing asbestos-containing in sulation and how this will affect us economically. The use of Aircell pipe insulation should be eliminated from the plant. It should never be used in any application over 200F. and then for personnel protection only. It has a K factor of . 61 as compared to . 29 for Fiberglas. Fiberglas is about 25% more expensive to purchase; however, if aluminum foil is used with Aircell, as is the case many times, it is questionable whether one is more expensive than the other. (See table of estimated costs attached.) Temperature wise, Fiberglas is recommended up to 400F. It is available either plain or with a number of factory applied jackets, some of which are self-sealing. Ordinarily, we would cover the plain Fiberglas insulation with the same JM paper that is now used over Aircell.* It is necessary to wire the paper onto Fiberglas inasmuch as staples will not hold. This procedure makes the process slightly more time consuming than with staples. A completely dry piping system can be made up by using wedges of Fiberglas blanket for ells and fittings and covering these with preformed fittings of PVC. A waterproof tape can be used to seal the joints. In the temperature range of 400 to 1200F., calcium-silicate is still , the standard insulating material. As a substitute, we are presently making a survey of Careytemp 1500. This is an expanded silicon (perlite) material with a temperature range up to 1500F. It does not absorb water and has a very low chloride content. At the present time it con tains about 6% asbestos; however, in the near future it may be available in an asbestos-free form. The K factor is almost identical to calciumsilicate. Another alternate material for temperatures up to 800F. is cellular glass. This material is more expensive than calcium-silicate and should be used only where its special properties merit the extra cost. It is more dense than calcium-silicate and non-absorbent. This property makes it especially valuable where there is danger of autoignition. It is ideal for dual temperature vessels or pipelines. The material is easily worn away by abrasion and for this reason tank heads should be adequately protected. Glass cloth imbedded in epoxy resin is excellent for this purpose. EXHIBIT 1 Page 2 of 2 -2 * The material is available in preformed sections for both pipes and tanks. The K factor is very similar to calcium-silicate. The Dow Chemical Company has only recently entered this field with a material called Ceramic Foam. '' i t If you have any questions or want further information on insulation, please feel free to contact me. Roy Anderson Maintenance Engineer ACP & OCP Maintenance 222 Building Phone 6-4456 rb ST0000308 f *!>>> *c(1*r o*t oin trn H V l EXHIBIT II HYPO THETICAL COVERING JOB ST0000309 sQ r' INSULATING A 2" PIPE SYSTEM PER FOOT EXHIBIT HI >' ? AIRCELL ` (Aircell $ .29j>er ft* Material: _ (J.M. Paper, ' .<30 per ft. * * ' t. , $ .59 per ft. Labor: * (A ireell '$ 1.50 per ft. (J:M. Paper ' .12 per ft. - r $ 1.62 per ft. # Aircell total cost: - $ 2.21 per ft. ST00003I 0 AIR CELL WITH ALUMINUM FOIL Material: (Aircell $ '(J. M. Paper (Aluminum foil $ . 29 per ft. .`30 per ft. . 09 per ft. . 68 per ft. Labor: (Aire ell $ 1. 50 per ft. (J. M. paper . 12 per ft. (Aluminum foil . 03 per ft. . 9 1.65 per ft. Aircell with aluminum foil total cost: $ 2. 33 per ft. AIRCELL WITH THERMON Material: (Aircell (J.M. Paper (Thermon Labor: (Aircell (J. M. Paper (Thermon Aircell with thermon total cost: $ .. 29 per ft. . 30 per ft. . 40 per ft. $ . 99 per ft. $ 1. 50 per ft. . 12 per ft. . 26 per ft. 6 1. 88 per ft. $ 2. 87 per ft. Material: (Fiberglas (J. M. Paper Labor: (Fiberglas (J. M. Paper* Fiberglas total cost: $ . 43 per ft. . 30 per ft. $ . 73 per ft. % 1. 50 per ft. . 30 per ft. $ 1. 80 per ft. $ 2. 53 per ft. *J. M. Paper wired on Fiberglas vs. stapled on Aircell EXHIBIT IV COMPARATIVE INSULATION MATERIAL COSTS Size (inches) 1/2 3/4 1 1-1/4 1-1/2 2 2-1/2 3 3-1/2 4 5 6 8 4-1/2 12 7 1967 Usage of Aircell (feet) 400 1500 4000 6000 9000 11000 20000 6000 3500 3000 2500 7000 4000 3000 1500 1969 Prices (per. ft.) Aircell Fibergla $ .18 .29 .19 .31 .22 .34 .24 .26 .40 .29 .43 .32 .46 .36 .50 .40 .55 .48 .65 .56 - .64 - .88 1.46 .52 .69 1.48 - 1.18 82, 400' of Aircell used is 1967 . ST00003I I TJM 7-24-69