Document jma36dK2VmvQDYNowpwEj129
Heaters, Unit
Established 1894
John J. Nesbitt, Inc..
Manufacturers of
The Universal Heating and Ventilating Unit
Executive Offices and Factory State Road and Rhawn Street, Holmesburg Junction, Philadelphia, Pa.
Branch Office, 405 Lexington Avenue, New York City
Sales and-Service Through Offices of the American Blower Co. In all principal Cities of United States and Canada
Products
Manufacturers of the " UNIVERSAL" combined Heating and Ventilating Unit (Portable'Unit Ventilators), also "UNI
VERSAL" air filters.
"UNIVERSAL" Unit System of
Heating and Ventilating A mechanical system of ventilation for supplying fresh warm air directly from out of doors for use wherever good- ventilation is required and par ticularly suitable for school house ventilation.
"UNIVERSAL" Combined Heating
and Ventilating Unit
The Unit is built in sizes ranging from 500 to 4000
c.f.tn.
^^
Capacity CJ.OL. 400- 750 900-1500 2000 -
Height Inches
Length Inches
27 43 43
Depth Inches
14 14 18
All sizes can be arranged for floor or ceiling mounting.
Radiator
Standard " UNIVERSAL " Units are supplied with a radiator winch consists of horizontal seamless copper tubes, the ends of which are connected to a cast iron header by means of ground joints. Over these tubes are hydraulically pressed thin copper plates or fins properly spaced. Hydraulic pressure insures abso lute heat transfer from tube to fin, making the whole a highly efficient unit. This type is particularly sturdy and rigid and will give permanent service. Tested at 100 lb. pressure.
"UNIVERSAL" Air Filters
The use of air filters is .especially recommended for buildings located in congested .manufacturing dis tricts, or where the air is heavily laden with dust or soot. ``UNIVERSAL,'airfiltersare the adhesivejmpingement type, designed to fit in thefresh airintake of the "UNIVERSAL'' Unit. In this location the . velocity of air over the entire surface of the filter is uniform with the result that an equal amount of work is imposed throughout its entire area. Com bined with this ideal location is a set arrangement, which provides ease and simplicity of removal and replacement, when cleaning is necessary.
Fans "UNIVERSAL" Fans are of the multi-blade low speed double inlet type, designed to operate at 800 r.p.m., plus or minus 5 per cent. The fans are rigidly constructed of aluminum with special care
given to balance. Fans are mounted on double extended ends of the motor shaft.
Motor
The`motor of the "UNI VERSAL" Unit is supplied for quiet operation on any character of current. The use of a motor generator set is no longer necessary4 with this system, but will be furnished upon request.
Volume Control
. When a fine adjustment is desired for obtaining either a larger or smaller volume of air than a given set of fans discharge from a given line voltage, air volume regulators will be furnished. Air volume regulators con sist of .curved plates, which may be readily adjusted to further open or close the fan discharge opening. The re duction of the air delivery results in a corresponding reduction of current con
sumed.
Vertical section, end removed, UNIVERSAL UNIT. Series No. J4-S64&- Fresh air intake through wall box and grille near bottom of Unit. This Unit eon be recessedto depth of 4 in. as shown, recess must be 60 in:long by $6 in. high, or can be recessed 8 in. in .45 in. long recess S6 in. high. Standard practice places the Unit flush with the inside wall.
498
Three-Point
Lead Mounting
The motorand fanassembly of the "UNIVERSAL" Unit is mounted in the cabinet on threesteelbail points. These points rest on lead liners, supported by angles from the side of the casing. This three-point lead mounting has made possible the use of alternating current motors with a permanent and rigid supporting device.
Catalogue and Engi
neers' Data Book
A copy of our "Catalogue and Engineers' Data Book" containing complete engi neering data, specifications, etc., on "UNIVERSAL" Unit Ventilation' System, will be furnished upon re quest to our executive office.
I#'-- ',M \ --
^
. .
\
\
Heaters, Unit
Pecco Incorporated
Main Office and Factory
2957 North Market Street
St. Louis, Missouri, U. S. A. ,
UNIT
HEATERS
Davenport, Iowa . Columbus. Ohio
District Sales Offices
Cincinnati, Ohio Baltimore, Md.
New York, N. Y. Boston, Mass.
Pecco Steam Units
Pecco Unit Heaters are built in two types, Steam
Coil and Direct Fired.
The advantage of these units as illustrated, is in the
fact that they are designed to operate in accordance
with natural laws.
The cooler air is drawn off the floor and the warm air
discharged out in a horizontal direction above the
working zone. In this way a constant circulation is
maintained in the working zone which produces more
uniform temperatures and keeps the heat down where
. it is wanted. This circulation prevents excessive loss of
heat to the upper levels.*
~
,. Pecco Heaters are built to the highest kind of
standards. The steam coils are guaranteed for any
steam pressure up to 125 lb. and the fan units are of the
very best design, carefully balanced and operating on
ball bearings. .Capacities range from 130,000 B.t.u.
to 1,700,000 B.t.u. when recirculating air at 60 deg.
Chicago, III. Pittsburgh, Pa.
Direct Fired Type
Direct Fired Type
The Pecco Direct Fired Heater, which burns either . coal, coke, gas, wood or .oil, is built on the same principle as the Steam Unit and is just as effective in maintaining proper temperatures near the floor over large areas.
We also manufacture .a light weight copper tube fin type heater for smaller buildings or special conditions.
We maintain an organization of experienced heating engineers who are ready to serve you in working out your heating problems. Ask for catalogs or for the assistance of our engineers.
499