Document jmX3eqoRK8edxmYmwN25Q7BYQ

544' CHAPTER 25 1949 Guide T Heat Loss from Direct Radiation, by J. R. Allen(A.S.H.V.E. Transactions, Vol. 26,. 1920, p. 11). * Heat Output of Concealed Radiators, by E.' A. Allcut (University of Toronto, School of Engineering, ResearchBulletin No. 140, 1933). ' The Heating Effect of Radiators, by Charles Brabble (A.S.H.V.E. Transac tions, Vol. 33, 1927, p. 33). i University of Illinois, Engineering Experiment Station Bulletins Nos. 192 and 223, and Investigation of Heating .Rooms with Direct . Steam Radiators Equipped with Enclosures and Shields, by A. C. Willard, A. P. Kratz, M. K. Fahnestock and S. Konzo (A.S.H.V.E. Transactions, Vol. 35,1929, p. 77). 11 A.S.fl:V.E. Research Report No. 962--The Application of the Eupatheoscope for Measuring the Performance of Direct Radiatois and Convectors in Terms of Equivalent Temperature, by A. C. Willard, A. P. Kratz and M. K. Fahnestock (A.S.H.V.E. Transactions, Vol. 39,1933, p. 303). u The Kata Thermometer--Its Value and Defects, by W. J. McConnell and C. P Yagloglou; (Reprint No. 953 from U. S. Public Health Service Report, pp. 2293-2337. September 5, 1924). 11 The Thermo-Integrator--A New Instrument for the Observation of Thermal Interchanges, by C.-E. A. Winslow and Leonard Greenburg (A.S.H.V.E. Transac tions, Vol. 41,1935, p. 149). . 14 The Calibration of the Thermo-Integrator, by C.-E. A. Winslow, A. P. Gagge, Leonard Greenburg, I. M. Moriyama and E. J. Rodee. (The American Journal of Hygiene, Vol. 22; No. 1, July, 1935, pp. 137-156.) 14 The Globe Thermometer in Studies of Heating and Ventilation, by T. Bedford and C. G. Warner. ' (The Journal of Hygiene, Vol. 34, No. 4.) 14 A.S.H.V.E. Research Report No. 1067--The Cooling and Heating Rates of a Room with Different.Types of Steam Radiators and Convectors, by A. P. Kratz, M K. Fahnestock and E. L. Broderick (A.S.H.V.E. Transactions, Vol. 43,1937, p. 389)' ,`J University of Illinois, Engineering Experiment Station Bulletin No. 230, p. 20. Reheating by Means of Refrigerant Compressor Discharge Gas, by S. F. Nicoll (A.S.H.V.E. Transactions, Vol. 47,1941, p. 239). CHAPTER 26 UNIT HEATERS, UNIT VENTILATORS, UNIT HUMIDIFIERS Definitions; Unit Heaters: Classification, Application, Outlet Velocities, Ratings for Various Types, Temperature, Automatic. Control, Location, Piping Connections; Boiler Capacity for Steam Unit Heaters; Unit Ventilators: Ratings, Applications, Location, Exhaust Vents; Window Ventilators; Unit Humidifiers DESCRIPTIONS of heating, cooling, ventilating, humidifying, and dehumidifying systems are given in other chapters. This chapter deals with unit heaters, unit ventilators, and unit humidifiers. Cooling units, unit air'conditioners, and attic fans are described in Chapter 36. Definitions The generally accepted meaning of the word unit in the terms unit heat ers unit ventilators, and unit humidifiers is that of a factory made, encased assembly of the functional elements indicated by its name. Such units can be shipped complete or in sections so that the only field work necessary is the assembling of the sections, providing proper supports and coimecting the unit to sources of heat (or fuel), power and water supply, and, if neces sary, to vent pipes for combustion gases. The term unit heater denotes an assembly of elements the principal func tion of which is heating. The essential elements of a unit heater are a fan and motor, a heater; a housing, and outlet vanes or diffusers. The term unit ventilator denotes an assembly the principal function of which is to ventilate. It may serve to circulate air within the space, or to introduce air from without the space, or may accomplish both purposes. The essential elements of a unit ventilator are a fan and motor, a heater, a set of dampers, a housing and outlet vanes or diffusers. The term unit humidifier denotes an assembly of elements the principal function of which is to humidify. The essential element of a unit humid ifier is an atomizer or evaporator. To this may be added a fan, a heater, outlet vanes or diffusers, and a housing to enclose the various parts: UNIT HEATERS Classification The various types of linit heaters which are at present available can usually be classified according to one of the three following methods: 1. By type of heater. Under this classification there are three types of heating elements to be considered: (a) the steam, or hot water type, (b) ihe electric type, and (c) the direct fired type which may be gas, oil, or coal fired. 2. By type of fan. Under this classification there are two types of-fans to be considered :(a) the propeller type1 which may be equipped with a hori zontal or vertical shaft, and (b) the centrifugal type which may be designed for horizontal or vertical blow. . 3. By arrangement of elements. Under this classification there are two types of heaters to be considered: (a) the drawfhrough type, in which the 645