Document jmQnGe35jGewQ0do46M795Yjy
TO:
Pat Jernigan
*0: RF
Interoffice
Communication
FROM: DATE:
SUBJ:
T. G. Grumbles March 28, 1989
TOXICITY TESTING RECOMMENDATION FOR V-2100
VISTA
The VTAC has reviewed the toxicity testing needs for V-2100 to be produced at Baltimore. Based on our review, described below, it is recommended the following testing be done:
Primary Dermal Irritation Primary Eye Irritation
The testing should be done as soon as "commercial grade" product is available. Based on conversations with the plant, I believe the April test run product will be appropriate.
The constituents of V-2100 are known to show low irritation potential and exhibit low oral and dermal toxicity. However, the data we have for both is from testing in 1975. To assure us that the blended material will exhibit similar toxic properties and verify the quality of the 1975 data we are recommending at least dermal and eye irritation testing be done.
Please let me know if you approve the above or have questions regarding the recommendation.
T. G. Grumbles
dlj
cc:
0. C. Kerfoot, A. M. Nielsen-Ponca City P. Warner, R. Henneman-Baltimore
W. L. McClain
vvv 00000697*