Document jmO8VLJ5BGg89Q46ZZyXxMDM9
736
CHAPTER 53
1960 Guide
Equation 2 is applicable when the Reynolds number Cor liquid drops is less than 10. Drop diameters are almost al ways less than 500 microns, and are usually in the range of 20 to 150 microns.
The rate of evaporation of drops may be expressed in terms of heat transfer or mass transfer. In terms of heat transfer, the evaporation rate is given by the equation:
dw d$
2rk/Dp H
(t.
-
t.)
(3)
where
-- TM evaporation rate, pounds per hour.
tary dryers, vacuum rotary and vacuum tray dryers, and in fra-red dryers.
A principal difference between indirect drying and direct
drying is that, with the former, the material is usually at a
higher temperature than the surrounding air, so that heat is
actually transferred to the air instead of from the air.
The Failing-Rate Period. In the discussion of the periods of
drying, it was shown that the (hying process is discontinuous,
consisting of a period of a constant rate of evaporation and a
period in which the rate continuously decreases. (See Fig.
2.) This latter period is usually designated as the falling-rate
period. It begins when the constant-rate period ends at the
critical moisture content. If the critical moisture content is
less than the required final moisture content, the constant-
rate period will constitute the whole of the drying process.
On the other hand, if the initial moisture content is ><* than
the critical moisture content, as in the case of some slow-
drying materials, such as soap and wood, then no constant
rate will appear, and the whole of the drying process will be
in the falling-rate period. This period, in the most general
case, can be divided into two zones which may be termed
(1) the zone of unsaturated surface drying, and (2) the zone where internal liquid flow controls.
The zone of unsaturated surface drying follows immediately after the critical point and results from a progressively de
creasing wetted surface. With the surface no longer completely
wetted, dry portions of the solid protrude into the air filmJ so that the rate of evaporation per unit of total surface is
reduced. The effective wetted surface in this zone is frequently a linear function of the water content, so that the curve repre
senting rateof drying vs. water content of the solid is straight
in this region, as shown by line AD in Fig. 2. The
of drying is essentially the same as during the constant-rate period.
The zone where internal liquid flow is in control is usually
the second zone of the falling-rate period. In this phase the
rate of internal liquid movement by one or more of the con
trolling mechanisms considered previously, such as diffusion, capillarity, etc., will determine the drying rate.
When diffusion does control in the falling-rate period, it
obeys the same fundamental laws of diffusion as those ap
plying to the diffusion of heat. Thus for the
where the
surface is dry or at the equilibrium moisture content, and the
solid has a uniform initial moisture distribution, the following
rate equation holds for relatively large values of tim $t and
when (w -- ,)/( -- to.) < 0.6
Drying at Air Temperatures above the Boiling Point of the Liquid. When the temperature of the drying air is maintained above the boiling point of the liquid being evaporated, or whensuperheated vapors are used for drying, the usual equations for mass transfer, expressing rate of evaporation as a function of the vapor-pressure difference, lose significance, since large errors are introduced in the expression for vapor-pressure driving force due to its apparently small value. Such cases can be treated conveniently oq a basis of beat transfer, since a temperature difference must always exist in order that drying may proceed.
Constant-Rate Period When Heat Transfer Depends on Conduction and Radiation. In indirect drying, where heat transfer and drying do not depend on the flow of heated gases,
the drying rate depends either on heat conduction through retaining walls to wet material in contact with such surfaces, or on radiation, or both. This applies to drum dryers, agitated pan dryers, indirect continuous sheet dryers, steam tube ro-
where
dto
; (w - fc) dB
(4)
w *= moisture content on dry basis, at any timw 0, pounds of water per pound.
u, moisture content at equilibrium with external condi tions, pounds of water per pound of dry material.
" moisture content at start of diffusional period, pounds of water per pound dry material.
d = tile liquid diffusivity, square feet per hour. L ~ one-half material thickness, feet.
Equation 4 is restricted to a slab-shaped solid, the length of which is large compared with the thickness.
For some materials tire drying time in the falling-rate period varies directly with the thickness. When this occurs the falling
Industrial Drying Systems
737
Table 2 .... Approximate Classification of Materials Most Likely to Obey Equations 4 and 5
Materials Obeying Equation 4
1. Single-phase solid systems such as soap, gelatin, glue. 2. Wood and similar solids below the fiber saturation point. 3. Last stages of drying starches, textiles, paper, clay, hydro
philic solids, and other materials when bound water is being removed.
Matarkdt Obeying Equation S
1. Coarse granular solids, such as sand, paint pigments, min erals, etc.
2. Materials in which moisture flow occurs at concentrations above the equilibrium moisture content at atmospheric saturation, or above the fiber saturation point-
rate can be expressed with fair accuracy by the following equation:
(dw/dO)e (tc -- to.)
(tOe -- tfc)
(5)
{du/dB), =* the constant drying rate, pounds per (hour) (pound dry material).
( 7")> * falling rate, pounds of water per (hour) (pound V*& ft of dry material).
to " the critical moisture content, pounds per pound dry material.
(*).The appropriate expression for
obtained from Table
1, may then be substituted in Equation 5. Table 2 gives an approximate classification of materials that
are most likely to obey Equations 4 and 5.
Equilibrium Moisture Content
In the drying of solids it is important to distinguish between hygroscopic and non-hygroscopic materials. A hygroscopic material is one which retains a definite percentage of moisture
Fig. 4'.... Typical Equilibrium Moisture Content Curves1
under definite conditions of air humidity. This bound moisture is in a state of equilibrium with the water vapor in the sur rounding air. A decrease in the water vapor content will decrease the amount of equilibrium bound water. Water so retained by a solid in equilibrium with the humidity of the surrounding air, is designated as the equilibrium moisture content. Such moisture may be held as adsorbed surface films or condensed in fine capillary structures at reduced vapor
pressure. The equilibrium moisture content varies with the tempera
ture and humidity of the surrounding air. Consequently, any correlation of equilibrium moisture content should take these two factors into account. However, at low temperatures, e.g., 60 to 120 F, a plot of equilibrium moisture content vs. percent relative humidity, expressed as 100'(p/p.), is essen tially independent of temperature. Such a plot usually re sults in a curve of double curvature with a point of inflection (see fig. 4).
APPLICATION OF HYGROMETRY TO DRYING
In analyzing any particular drying problem it is sometimes,, advisable to consider the thermodynamic changes involving the drying medium, since in most cases the drying medium is . an air-water-vapor mixture. The thermodynamic process can -> be traced on a psychrometric chart.
The psychrometric chart, Fig. 5, suggested by Grosvenor/is suitable for most drying calculations. The adiabatic cooling lines on the chart indicate the paths along which the changes in the thermodynamic properties of the air occur in an adia batic dryer.
The theoretical ability of air to pick up moisture corre sponds to the difference"between the final saturation content at the wet-bulb temperature (approximately the adiabatic cooling temperature or thermodynamic wet-bulb temperature) and the initial moisture content at the supply air dew point.. The imfiwnim possible pickup is never achieved in practical dryers because on the basis of good design, this would be undesirable. Experience has shown that there is an optimum pickup which is a function of the independent drying variables and is lews than the maTimtim theoretical value as obtained
from the psychrometric chart. It should be noted that in practice the process will not
necessarily follow exactly the adiabatic cooling line since there may be a transfer of heat to the tray or conveyor itself.
Use of the psychrometric chart for analysing drying prob
lems is illustrated by Example l.
Example 1: Assume a dryer having a capacity of 100 lb of
gelatin per hour at 11.1 percent bone-dry basis. The initial mois
ture content is 228 percent bone-dry basis and the final mois
ture content is to be 32 percent bone-dry basis. The rate of pro
duction of bone-dry gelatin is 90.5 lb per hr. Supply air is
available at 120 F dry-bulb, 85 F wet-bulb{-with make-up
air at SO F dry-bulb and" 65 F wet-bulb. Air is exhausted
from the dryer at 100 F dry-bulb and 84.5 F wet-bulb.
y
Find (1) the required amount of make-up and exhaust air, and (2) the percentage of recirculated air.
Solution: Refer to psychrometric chart. Fig. 5, and obtain
the humidity ratio of the make-up air and of the exhaust air. In order to maintain a steady-state condition in the dryer the water which is evaporated from the material must be carried
away by the exhaust air. Therefore, the difference between'the . humidity ratio of the exhaust air and that of the make-up air
(known as pickup) is equal to the water evaporated from the
material divided by the pounds per hour of dry air in the ex
haust.
Step 1: The moisture in exhaust air at 100F dry-bulb and84.5 F web-bulb is found to be 0.022 lb per pound of dry air.
The moisture in make-up air at 80 F dry-bulb and 65 F wet-