Document jmO86LkyLjx5w2MNgy27dNZkk

Monsanto r MIC/TP&E/WGK Plant Process Research (CO./DIV./DEPT./LOCATION I Progress (TYPE OF REPORT) REPORT CMW/3 O co zoM 3 hl-Jl H CMO Q u Erf w ui PB pMm Q ,pJH iH0o)o CoOPM >O COM . CMO SB O . oZ co S REPORT NO.: JOB/PROJECT NO.: DATE: 1 45000 760,42 1615103 February 27, 1976 TITLE: Monoisopropylbiphenyl Distillation Studies AUTHORS: S. H. Vogel D. K. Lynch ABSTRACT: This report describes a study on "Continuous Flash Distillation" of crude Monoisopropyl- biphenyl (MIPB). MIPB is a component in MCS*-1238, a potential replacement for Aroclor. ccoc O .. X 1U 5 f! <P i \ >r> \ O z o z i-- CM UJ CC >Qoo. R-1068(A) Not Restricted (Qualified persons may obtain from Central Reports). DSW 261114 COMPANY CONFIDENTIAL This document is the property of Monsanto Company and the recipient is responsible for its safekeeping and disposition. It contains CONFIDENTIAL INFORMATION which must not be reproduced, revealed to unauthorized persons or sent outside the Company, without proper authorization. STLCOPCB4061918 DISTRIBUTION COPY NUMBER 1-3 Technical Reports Library 4 Circulate to MICC Director of Technology, R&D Managers, and return to Central Reports - R2C 5-6 TSD Library WGK 7 Plant Process Research File WGK 8 S. M. Balaban W2A 9 K. E. Boucher WGK 10 D. R. Cova T3C 11 W. C. Engman WGK 12 M. E. Gibbs W1A 13 W. C. Hammann B3SA 14 H. J. Horner WGK 15 G. L. Johnson WGK 16 R. A. Pohl B2SB 17 J. F. Quinn T3B 18 S. H. Vogel WGK 19 D. Wood B2SC 20-24 D. Danna EISA 25 D. K. Lynch WGK ABSTRACT ONLY \ COMPANY CONFIDENTIAL When no longer needed, or upon request, return this report to Central Reports Library - R2C oS\N 26^15 STLCOPCB4061919 TABLE OF CONTENTS INTRODUCTION SUMMARY DETAILS I. EXPERIMENTAL EQUIPMENT II. GLC METHOD OF ANALYSES III. DISCUSSION A. SYSTEM START-UP AND OPERATION B. : FOAMING/BUMPING C. BOILING POINT VS THROUGH-PUT D. PRODUCT COLOR & ACCEPTABILITY INMCS-1238 E. FEED & DISTILLATE MOISTURE CONTENT F. CORROSION TO STEEL G. RESIDUE & SYSTEM YIELD H. GLC ANALYSES, PRODUCT, FEED, &RESIDUE APPENDICES FIGURE NO. 1 DIAGRAM OF DISTILLATION APPARATUS TABLE NO. 1 DATA SUMMARY & COMMENTS SHEET TABLE No. 2 DATA - DISTILLATE' COLOR VS DISTILLATION CONDITIONS TABLE No. 3 GC ANALYSES OF FEED, PRODUCT, & RESIDUE FIGURE NO. 2 CHROMATOGRAM OF CRUDE MIPB FEED FIGURE NO. 3 CHROMATOGRAM OF DISTILLATE NO. 2 FIGURE NO. 4 CHROMATOGRAM OF DISTILLATE NO. 21 FIGURE NO. 5 CHROMATOGRAM OF RESIDUE - END OF RUN Page No. 1 1 2 2 2 2 2 3 3 3 4 4 5 5 DSW 261116 STLCOPCB4061920 Progress Report No. 1 MIPB Distillation Studies Job No. 1615103 1. INTRODUCTION The use of polychlorinated biphenyls (PCB) for capacitor dielectric fluids may eventually be discontinued due to environmental considerations. MIC R&D is currently developing substitute, non-PCB, fluids for capacitor use. A blend of tolyl xylyl sulfone (TXS) and monoisopropylbiphenyl (MIPB) is one fluid being considered. MIPB however, must be refined prior to blending as prescribed in PED document P-1797, "Blending, Refining, & Drying of MCS 1238 - A Dielectric Fluid". Work described in this report concerns MIPB refining by continuous flash distillation. The study was carried out during Jan./Feb., 1976 by the WGK Plant Process Research group. The work was done primarily to determine boiling point rise versus through-put. This information was needed to determine if similar type refining might be possible in current WGK Aroclor equipment using 200 lbs. steam as heat source. . SUMMARY ' Continuous flash distillation of crude monoisopropylbiphenyl (MIPB-2) obtained from Dixie Chemical Co. was carried out in a laboratory apparatus. The unit was operated at 25 mm Hg pressure. High boiler residue was allowed to concentrate in the pot during the distillation while maintaining a fixed pot volume. Pot temperature rose from 183C to 225C after about 250 through-puts. This trans lates to <0 .5% residue or a yield loss of less than 0.5 lbs./lOO lbs. crude feed. Some foaming was observed, particularly when feeding subsurface. Good agitation is essential, or foaming and bumping are intolerable. Distillate color darkened gradually with through-puts as well as with increased rates, indicating some en trainment. A demister in the vapor duct significantly improved distillate color. Corrosion to a steel coupon in the pot was nil (39 hrs.). There was no evidence of insolubles (inorganic salts) buildup in the pot residue or distillate lines. Product distillate was blended with TXS by R&D at G. 0. Acceptable quality MCS1238 resulted. Pot residue was a dark brown liquid, reasonably mobile at room temperature. The residue has been sent to R&D for further evaluation. Use of current Dept. 248 equipment for similar refining, but with 200 lbs. steam heat, does not appear feasible. Heat from 200 lb. steam would not be adequate to achieve the temperatures required. DSW 26II17 STLCOPCB4061921 Progress Report No. 1 MIPB Distillation Studies Job No. 1615103 2. DETAILS I. EXPERIMENTAL EQUIPMENT A schematic of the apparatus used in the distillation studies is shown on Figure No. 1. Material was fed via a microbellows pump which was actuated "ON/OFF" by the photocell level controller. The photocell was triggered ON/OFF by a float on the surface of the liquid in the level controller tube. A spring loaded relief valve, set to open at pressures above 17 lbs. was placed in the feed line between the pump and the distillation system. This prevented material from being drawn into the system unless the feed pump was operating. Except for the final part of the run, the pot level was maintained at 125 ml by height adjustment of the level controller. There was no measur able pressure difference between the pot and condenser exit. II. GLC METHOD OF ANALYSES Hewlett Packard Model 5712A Gas Chromatograph equipped with TC detector and appropriate Integrator was used for semi-quantitative analyses of feed,'dis tillate and residue samples. Conditions were as follows: Column 6' x 1/8" s.s. - 10% W 98 on Chrom W, 80/100 mesh Detector 350C. Injection 280C. Oven 140C isothermal 4 min, 8C/min --^ 320C and hold 16 min. yiCarrier Helium - 30 ml/min. 1.0 Injection of "as is" sample. Attenuation 8 XI Bridge Current 110 ma Quantitation is by normalization of total area of all eluting components. No compensation is made for possible non-eluting compounds or variation in response for the individual components. III. DISCUSSION A. SYSTEM START-UP AND OPERATION In start-up, the system (Figure No. 1) was first evacuated to 25 mm Hg pressure. The feed pump was started and 125 ml pumped into the distillation pot. Heating was then started. When distillate began to come over, automatic feeding was started. Pot and distillate lines were insulated with three layers of insulation. Pot heat was supplied by resistance wire and regulated by powerstat variable transformer. Temperatures in the pot (vapor & liquid) and distillate vapors (head) were monitored by thermocouple and plotted vs time by multipoint recorder. DSW 261118 STLCOPCB4061922 Progress Report No. 1 MTPB Distillation Studies Job No. 1615103 3. III. DISUCSSION (Cont'd.) The system was operated at various feed/distillate rates. Operating characteristics and distillate quality were observed at the different rates. Tempered water was used on the condenser in order to get only partial condensation of water vapor from the distillate, and thus a lower moisture content in the product. Condensate collected in the cold traps was not quantitated due to an upset which caused product to be drawn into the traps (receiver over flowed and backed into traps). Data and comments from the run are found on TABLE No. 1. B. FOAMING/BUMPING . The pot was fed subsurface for the first 3-4 through-puts. Much foaming occurred. This condition was probably due to degassing of.the feed as well as flashing of low boilers such as moisture. A degassing surge vessel might eliminate this problem. With surface feeding, foam ing was negligible. Good agitation is essential, or bumping is intolerable. This is true regardless of surface or subsurface feeding. Although surface feeding was used for most of the run, boiling was ob served over the entire surface area of the pot liquid. This indicates the feed material for the most part went into the pot liquid before boiling (e.g. pseudo-subsurface feeding). C. BOILING POINT VS THROUGH-PUT The initial boiling point of the pot material was 183C. (25 mm Hg). The boiling point increase with through-put rose quite rapidly early in the run. Boiling point increase from 195C. and up was quite slow (see TABLE 1 data). The distillate head temperature remained about 183C., throughout the entire run regardless of through-put or rate. Early temperature readings of about 165C. are throught to be in error due to inadequate insulation on the distillate lines. D. PRODUCT COLOR Three factors had a significant influence on distillate color. They were entrainment, vapor disengagement rate, and through-put (see TABLE 2). Product color slowly increased from 8 to 30 apha during.the first 52 throueh-puts, while running at a constant disengagement rate of about 0.7 grams/min/in^. Pot liquid also gradually darkened during this period, suggesting the product color darkening was probablv DS\N 26m9 STLCOPCB4061923 Progress Report No. 1 MIPB Distillation Studies Job No. 1615103 4. III. DISCUSSION (Cont'd.) to pot liquid entrainment. When the disengagement rate was reduced to about 0.2 grams/min/ln^, at about 55 through-puts, product color improved to 8 apha. There was probably less entrainment at the lower disengagement rate. A "Goodloe" Type A Column, 25 mm diameter and 3 inches high, was in stalled in place of the "Ace" adapter distilling trap. Product color improved from 30 to 5 apha with the change. Disengagement rate was then increased to about 1.1 gram/min/in^ . Product color darkened to 20 apha indicating continued entrainment, but not nearly as severe as when running with the Ace distilling trap. Product color did not ap pear to change with increasing through-put (due to pot volumn reduc tion) after installing the Goodloe column (compare samples 18 and 21, TABLE No. 2). The Goodloe column is packed with stainless steel gauze. Distillate sample No. 15 was evaluated for acceptability in MCS-1238 by Functional Products R&D at G.O. The material was satisfactory-in all respects. E. FEED & DISTILLATE MOISTURE CONTENT Moisture content of feed and distillate material were determined by Karl Fisher method using methanol as solvent. Feed Distillate Sample No. 3 <2.5 ppm Distillate Sample No. 17 16 ppm Distillate sample No. 3 may be erroneously low due to air leaks into the distillation system. The specification of <30 ppm is easily achieved. F. CORROSION TO STEEL The steel corrosion coupon positioned in the pot during the distilla tion showed essentially no corrosion for the duration of the run. (39 hours exposure at temperatures above 195C.). There was no dif ference in corrosion to the coupon between vapor and liquid contact. Any effects the steel coupon may have had on product quality or residue characteristics are not known because no portion of the run was made without the coupon present. No gross effects were apparent however, since product quality-was acceptable. .. DSW 261120 STLCOPCB4061924 Progress Report No. 1 MIPB Distillation Studies Job No. 1615103 5. III. DISCUSSION (Cont'd.) G. RESIDUE AND SYSTEM YIELD Residue collected, after boil down and operation at 225C. pot temp erature, was 33.0 grams. GC indicates the material to be 45-75% high boilers. The residue was dark brown in color and was still semimobile at room temperature. There was no evidence of any insoluble type substance, such as inorganic salts in the residue or distillate lines. Total through-put in the system was 8355. grams. At most, the high boiler content in the feed was therefore: 0.75 x 33.0 x 100 = 0.30% 8355.0 Yield loss as residue was: 33.0 x 100 8355.0 0.39% ' This represents a system yield loss of C0.5 lbs./lOO lbs. crude feed. The residue has been given to Functional Products R&D for further evaluation. H. GLC ANALYSES OF FEED. PRODUCT. & RESIDUE TABLE No. 3 summarizes GC analyses of Feed, Product, and Residue. There was no appreciable change in distillate composition throughout the entire run. High boiler content gradually increased in the pot material (residue) during the run. Some of the crude MIPB remaining in the residue at end of run may be recoverable by further boil down. Chromatograms of crude MIPB, distillate, and residue samples are appendixed (Figures 2 thru 5). XHYlJL S. H. Vogel emc DSW 261121 STLCOPCB4061925