Document jmO1KGwdNmKDKvyRgoaDmw81Z

Air Conditioning . Surface Combustion Corporation Janitrol Executive Offices: 2375. Dorr St., Toledo 1, Ohio Winter and Summer-Air Conditioners, Gravity Furnaces, Conversion Burners, Floor Furnaces, Domestic Hot Water and Steam Boilers. Gas or Oil Fired. Complete specifications and performance data are available upon request from the Engineers Service Bureau of Surface Combustion Corporation. WINTER AIR CONDITIONERS. ; .Available in a complete range of sizes which may be used successfully with either radiant or convection systems. These condi tioners are suitable for use with small diameter duct systems and for perimeter heating. Construction features include choice of Dura-tube (for greater protection against rust and corrosion) or standard steel heat exchangers,-patented design ribbon burn ers, large capacity blowers and filters. A.G.A. approved for sea level and at high altitude operation; also approved for close clearance alcove and closet installations (subject to local building codes). For all gases including L-P. Model FEC-45 Conditioners (Dura-tube heat exchangers): t>e*-*rrmanre Model No. FEC60-45 FEC75-45 FEC90-45 FEC105-45 Ratings--JUtu per hr. A.G.A. Input AG.A. Output At Bonnet &U.000 75,000 90,000 105,000 48,000 60,000 72,000 84,000 CFM Del. for F Temp. Rise 80 100* 525 418 655 525 790 630 920 733 Motor HP 11560-1 No. 2 >6 2 w2 H2 Filters Site 16 X 20 X 2 16 X 20 X 2 20 X 20 X 2 20 X 20 X 2 FEC120-45 FECI50-45 FRCIMU* ITodd No. FEC60-45 FEC75-45 FEC90-45 FEC105-45 120,000 150,000 isn non 96.000 120,000 144.000 1050 1310 1575 841 1053 1260 Dimensions--inches Cabinet J3 Width aQ Height Q Warm Air Outlet 18W 26 60M 18*4 26 60*4 22*4 26 60*4 25 26 60*4 8 X 15*4 8 X 15*4 8 X 19M 8 X 22H M 2 25 X 20 X 2 M 4 16 X 20 X 2 14 4 20 X 20 X 2 Return Air Inlet 9*4 X 16*4 944 X 16*4 944 X 20W 944 X 22*4 Approx. Ship. Wt., Lbs. 312 325 356 380 FEC12IM5 FEC150-45 FEC180-45 28 26 66M 34*4 26 60*4 42*4 26 60*4 8 X 25*4 8 X 31*4 8 X 39*4 944 X 25*4 944 X 32*4 944 X 40*4 407 481 572 Model FES-45 Conditioners: The model FES-45 conditioners (with steel heat exchangers) are available in 7 sizes which are similar in dimensions and performance to the 7 sizes of the Model FEC-45 conditioners described above. Large Capacity Model FES Conditioners (steel heat exchangers): For use in more spacious homes, in public buildings and in commercial installations, the model FES-45 conditioner ^is available in the capacities described below. Performance Model No. FES210-45 FES240-45 FES300-45 FES360-45 Ratings--1 Mu per br. A.GA,. Input A.GA.. Output at Bonnet 210,000 240,000 300,000 360.000 168,000 192,000 240,000 288,000 CFM Del. for F Temp. Rise 80 1840 2100 2620 3150 100" 1466 1682 2106 2520 Dimensions--inches Motors 230-60-1 No. H.P. 2 *4 2 *4 2 *4 2H No. 2 2 4 4 Model No. FES210-45 FES240-45 FES300-45 FES360-45 Width 5044 5644 68*4 84*4 Cabinet Depth 26 26 26 26 Height 60*4 60*4 60*4 60*4 Warm Air Outlet 8 X 48 8 X 64 8 X 68*4 8 X 82*4 Return Air Inlet 944 X 48*4 944 X 54*4 944 X 66*4 944 X 82*4 1206 Filters Site 20 X 25 X | 20 X 25 X 1 16 X 25 X | 20 X 25 X !_ Approx. Ship Wt, Lbs. 750 950 U30___ _ Air Conditioning Antomatic'Equipment Gas FiredjtJnits Surface Combustion Corporation Janitrol Executive Offices: 2375 Dorr St., Toledo 1, Ohio Unit Heaters, Heavy Duty Blower Type Heaters, Floor Type Unit Heaters, Duct Furnaces, Large Capacity Conversion Burners, Kathabar Humidity Control Systems for Comfort and Processing. Gas Fired: Complete specifications and performance data are available upon request from the Engineers Service Bureau of Surface Combustion Corporation. UNIT HEATER. . '.Janitrol suspended type unit heaters are self-contained heat ing plants circulating large volumes of Ptmeneional Dmi heated air. The unit is suspended over head and utilizes a propeller type fan to direct warm air to the space where heat is most useful. The patented ribbon burners occupy a fixed position beneath the steel heat ex changer tubes which helps insure maxi mum equipment life, evenly distributed temperatures, and high operating effi ciency. This unique combination makes extra head room available underneath the unit because of its compact design. These unit heaters are specially con structed to provide quick, easy access to new internal parts should servicing be re quired. Available for all gases including L-P. For high al titude operation consult a Janitrol representative, or write to home office (address above). Performance Model No Ub&50~94 UBS85-94 UBS85-94 . UBSI00-94 UBS125-94 UBS165-94 UBS175-94 UBS200-94 UBS225-94 Ratings--pBtu per br. A.G.A. . AG.A. Input 1 Output* 50.000 65.000 85.000 40.000 52.000 68.000 100,000 125.000 165.000 80,000 100,000 132,000 175.000 200.000 225,000 140.000 160.000 180.000 Sq ft Steam Rad Equiv. 167 217 283 Air Ddiv., CFM 780 850 1235 Motor HP Mo Mo Ho Approx. Snip Wt., Lbs 133 152 191 333 1525 *4o 206 417 1825 *4o 244 550 1730 *4 298 583 2180 *6 298 667 2225 *4 352 750 2860 *4. 352 products cf '*"ce*v* air changes sufficient to adequately dispose of the assumed to beTO^^*00 anc* ur"l 13 invented, the available output can be Model No i A B C *5*4 5*4 isiijr 5*4 14*4 1544 18*4 5*4 18*4 in-1 5*4 20*4 6*4 20*4 D 6 6 7 7 7 8 20*4 I 8 ysJliS sb 20*4 I 8 20*4 * 8 Dimensions--inches E 1344 1644 1944 2244 2544 2144 2144 2544 2544 F G|H| J 12*4 15*4 18*4 17*4 20*4 23*4 22 22 *4 24*4 9*4 9*4 10*4 21*4 24*4 20*4 26*4 29*4 25*4 24*4 24*4 33*4 10 10 13*4 20*4 24*4 24*4 ' 25*4 29*4 29*4 1207 33*4 34*4 34*4 13*4 13*4 13*4 K |L| M 12*4 13*4 13*4 5 13*4 5 13*4 6 12*4 14*4 14*4 21*4 6 12*4 6 12*4 7 12*4 21*4 21*4 21*4 7 12*4 8 12*4 8 12*4 N 17 17 17 17 17 20 20 20 20