Document jm983npBVxzrMVm4o2q04413p

Minutes of Meeting Asbestos Study Committee August 17, 1972 SAMPLING FOR AS3EST0S FIBER COUKTING Mr. Stone questioned the possible moveaent of asbestos inside the filter sample when sent to the lab for exanination. Mr. Weaver indicated chat this possibility vas quite remote. Apparently the question arose after an OSHA visit to the camber's plant. In response to a question, one member indicated it takes about tvo months from the OSHA sampling until the OSHA report is received. Further, it vas indicated that the company hears if it is to be cited and not If the conditions are satisfactory. The OSHA regulations riT for an eight hour time weighted average (TWA) for the measurement of air borne concentration of asbestos fibers. One member indicated that he runs hi* sample test for a continuous four hours to compute the concentration. With a continuous four hour sampling, there are sometimes reactions from the shop people. Returning to the question on sampling for fiber counting, OSHA recommends a full straight eight hour sample. It vas indicated they used 8 filters during^ this continuous sample. A member suggested using 90 minute sampling for most a.eas, or a conpletf job c/cle if It tack longer then 90 drxtes. He recommended four hours of a ampling for specials. A member questioned as to what time vas necessary in sampling to determine the peak concentrations that cannot exceed 10 fibers per cc. Ho specific answer vas given, but ifr. Weaver indicated some sampling procedures which he felt were optimum for counting fibers entrapped by the filter. The number of teats for various conditions- is suggested in this tabulation. One condition la where you are measuring friction materials with asbestos In the compund, and Che other la for areas where you are handling all asbestos. Optimized time for fiber collection - depending on TWA fiber per cc concentration expected In area. (Optimum for counting fibers on the filter) Friction Materials TWA Fibers per cc Optimum Humber of Tests All Asbestos TWA Fibers per cc 0- 5 5-10 10-15 15-20 - 1-8 hr. test 2-4 hr. tests 3 tests , 3,3,2 hrs. 4-2 hr. tests 8-1 hr. tests 0- 3 3-- 6 6- 9 9-13 13-20 The question arose concerning the sample, where one is trying to pick up asbestos for counting. t?hat about the ottf^^i&rials in brake lining that are noons^ ere hazardous? Might these not be counted on the filter as well as asbestos? One answer that is indicated for the skilled laboratory man making the examination is that he should be able to distinguish between asbestos fibers and other materials. Further, one can go to 3Q0X on the microscope and get a closer look at the materials picked up on the filter. Dr. Spurgeon indicated that one can use low temperature ashing to remove resins and other organic materials (primarily friction dust). (O