Document jm6aD0O3kmjqQpoaMxONd0y1p
Air Conditioning, Automatic Heating Systems
Electrol Incorporated
FINE OIL HEATING EQUIPMENT EXCLUSIVELY SINCE 1918
934 Main Avenue, Clifton, N. J.
Conversion Burners, Boiler-Burner Units, Air Conditioning Units
ELECTROL
SUMMER AND WINTER AIR-CONDITIONING SYSTEMS
Winter Air-Conditioning
Direct-Fired Air-Conditioning Unit. Series DF. Designed for new homes or homes being remodeled. Fired by famous Electrol Oil Burner. Heats air and auto matically maintains temperature for which it is set. Cleans the air by means of effi cient renewable type filters. Positively circulates the air with a motor-operated, extremely quiet blower of ample capacity. Blower available in summer for circulation of filtered air. Humidification either pan type or spray type, with automatic control of room humidity. Guaranteed 80 per cent efficient when operated at rated capacities. Enclosed in attractive jacket.
Direct-Fired Air-Conditioning Unit. Series DF Capacities
Btu
Model
per hour at Bonnet
Max.
Btu per hour at Grilles
Max.
Air Temp, at Bonnet
Oil Rate
Lb . 1 Hour
DF0
DFI DF2
DF3 DF4
100,000 135,000 160,000 165,000 235,000
85,000 115,000
136,000 157,000 200.000
145-165 145-165
145-165
145-165 145-165
7.45 8.65
9.70 11.90
14.40
Heating Surface
Primary Secondary Total
CFM at70F
30 24 54 1000 50 36 86 1450
50 36 86 1650 50 36 86 ' 1850
76 36 112 2450
Air Capacity
Fan SP Speed V, 555 V, . 603 V, 500 '/. 513 '/< "428
Motor Hp
1/6 1/4 1/3 1/2 3/4
Economy model. Furnished without burner enclosure, galvanized finish on jacket. Guaranteed 75% efficient when operated at rated capacity.
Dimensions
Model
DF0 DFI DF2 DF3 DF4
Height
48 56'/, 56>/ 561/S 60'/,
Length
71 92'/, 92'/, 92'/, 96V,
Width
30 33'/, 33'/, 33'/, 35'/,
Outlet Width
21 24 24 24 24
Outlet Length
26 30 30 30 . 32
Inlet Width
20 24 24 24 24
Inlet' Length'
22 ' 24 24 24 28
Approximate Shipping Weight
850 1160 1200 1200 1550
Height of outlet and inlet collars for Duct Connection 1M in.
.h
Gravity Conversion Unit. Series FC. Designed for existing homes. Transforms an old wamFair heating plant into a modern winter air-conditioning system. Blower circulates atr^through efficient renewable filters which remove dust and impurities. Humidification assembly, spray type, located in jacket of furnace, adds proper amount of moisture, regulated automatically by humidistat in living quarters. Blower unit available in summer for circulation of filtered air throughout living quarters.
898
Electrol Incorporated
Air Conditioning, Automatic Heating Systems
WINTER AND SUMMER AIR-CONDITIONING
Split-System Air Conditioning Unit. Series SS. Electrol SS units provide for
all phases of air conditioning. The unit can be installed to provide winter air condi
tioning, and later cooling and dehumidifica
tion may be added to the same unit without
the necessity of changing the cabinet.
Both floor-mounted and ceiling-suspended
models are available; four sizes of the former,
three of the latter, with capacities as shown
in the table below.
Any Electrol fired boiler with sufficient
capacity and of proper design may be used
in conjunction with the Electrol Split-
System Unit. Specially designed heating and cooling
SS--Suspended Type
coils are used to provide rapid heat exchange possible, thus
ensuring economical operation.
Spray type humidification, automatically controlled by a
humidistat located in the living quarters, assures that the
proper degree of humidity is maintained at all times.
Compact, easily replaceable filters are provided, with
ample surface area to remove up to 90 per cent of the air
borne dirt, dust and pollen.
Completely automatic control, governed by thermostats
located in the living quarters is a feature of the SS Unit.
^ The Electrol Split-System permits the use of radiators in
rooms such as bathroom and kitchen where air conditioning
is not required.
S. S. 10 to 15 Suspended type.
55--Floor Type
Split-System Air Conditioning Unit--Series SS Capacities
Model
SSI SS2 SS3 SS4
ssto
SSI3 SSI5
Heating Capacity Btu per hour
Hot Water at 180
Steam 2 Lb Press.
93,000 170,000
233,000 . 304,000 "
91,800 171,600 246,800
317,900
46,000 66,000
90,000
46,000 66,400
90,000
Air Capacity
CFM
1120 2000 2700 3600
500 750 1000
WGS
W Vi" /,'
VtT V* '//
Fan Speed
640 558 656 630
555 600 555
Motor Hp
1/4 1/3 1/2 3/4
1/6 1/6 1/4
Cooling Capacity Btu per hour
Cold Water at 50 F
30,0001 50,0001 ,, 75,000 f 90,0001
14,000 26,000 35,000
Dir. Expansion (Freon) at 40 F
35,0001 62,0001 , 92,000 f 119,000 1
21,000 V' 31,000 42,000 *
Split-System Units should be selected on CFM capacity. E.D.R. is listed for esti mating boiler load only.
Heating capacities shown are for four-row coils on hot water and two-row coils on steam, and are based on entering air at 60 deg.
Cooling capacities shown are for four-row coils, three-row coils marked*, and six-row coils marked**.
Units are equipped with variable speed motor pulleys. Listed air capacities are maxi mum and are based on listed fan speeds with air at 60 deg.
SUMMER AIR-CONDITIONING
Room Cooling Unit. Series RC. Designed for single rooms in residences, offices, stores, etc., where summer air conditioning only is desired. Circulates cooled, dehumidi fied, filtered air throughout conditioned space. Direct expansion type coil with air cooled condenser.
(See also Page 967)
899