Document jm6aD0O3kmjqQpoaMxONd0y1p

Air Conditioning, Automatic Heating Systems Electrol Incorporated FINE OIL HEATING EQUIPMENT EXCLUSIVELY SINCE 1918 934 Main Avenue, Clifton, N. J. Conversion Burners, Boiler-Burner Units, Air Conditioning Units ELECTROL SUMMER AND WINTER AIR-CONDITIONING SYSTEMS Winter Air-Conditioning Direct-Fired Air-Conditioning Unit. Series DF. Designed for new homes or homes being remodeled. Fired by famous Electrol Oil Burner. Heats air and auto matically maintains temperature for which it is set. Cleans the air by means of effi cient renewable type filters. Positively circulates the air with a motor-operated, extremely quiet blower of ample capacity. Blower available in summer for circulation of filtered air. Humidification either pan type or spray type, with automatic control of room humidity. Guaranteed 80 per cent efficient when operated at rated capacities. Enclosed in attractive jacket. Direct-Fired Air-Conditioning Unit. Series DF Capacities Btu Model per hour at Bonnet Max. Btu per hour at Grilles Max. Air Temp, at Bonnet Oil Rate Lb . 1 Hour DF0 DFI DF2 DF3 DF4 100,000 135,000 160,000 165,000 235,000 85,000 115,000 136,000 157,000 200.000 145-165 145-165 145-165 145-165 145-165 7.45 8.65 9.70 11.90 14.40 Heating Surface Primary Secondary Total CFM at70F 30 24 54 1000 50 36 86 1450 50 36 86 1650 50 36 86 ' 1850 76 36 112 2450 Air Capacity Fan SP Speed V, 555 V, . 603 V, 500 '/. 513 '/< "428 Motor Hp 1/6 1/4 1/3 1/2 3/4 Economy model. Furnished without burner enclosure, galvanized finish on jacket. Guaranteed 75% efficient when operated at rated capacity. Dimensions Model DF0 DFI DF2 DF3 DF4 Height 48 56'/, 56>/ 561/S 60'/, Length 71 92'/, 92'/, 92'/, 96V, Width 30 33'/, 33'/, 33'/, 35'/, Outlet Width 21 24 24 24 24 Outlet Length 26 30 30 30 . 32 Inlet Width 20 24 24 24 24 Inlet' Length' 22 ' 24 24 24 28 Approximate Shipping Weight 850 1160 1200 1200 1550 Height of outlet and inlet collars for Duct Connection 1M in. .h Gravity Conversion Unit. Series FC. Designed for existing homes. Transforms an old wamFair heating plant into a modern winter air-conditioning system. Blower circulates atr^through efficient renewable filters which remove dust and impurities. Humidification assembly, spray type, located in jacket of furnace, adds proper amount of moisture, regulated automatically by humidistat in living quarters. Blower unit available in summer for circulation of filtered air throughout living quarters. 898 Electrol Incorporated Air Conditioning, Automatic Heating Systems WINTER AND SUMMER AIR-CONDITIONING Split-System Air Conditioning Unit. Series SS. Electrol SS units provide for all phases of air conditioning. The unit can be installed to provide winter air condi tioning, and later cooling and dehumidifica tion may be added to the same unit without the necessity of changing the cabinet. Both floor-mounted and ceiling-suspended models are available; four sizes of the former, three of the latter, with capacities as shown in the table below. Any Electrol fired boiler with sufficient capacity and of proper design may be used in conjunction with the Electrol Split- System Unit. Specially designed heating and cooling SS--Suspended Type coils are used to provide rapid heat exchange possible, thus ensuring economical operation. Spray type humidification, automatically controlled by a humidistat located in the living quarters, assures that the proper degree of humidity is maintained at all times. Compact, easily replaceable filters are provided, with ample surface area to remove up to 90 per cent of the air borne dirt, dust and pollen. Completely automatic control, governed by thermostats located in the living quarters is a feature of the SS Unit. ^ The Electrol Split-System permits the use of radiators in rooms such as bathroom and kitchen where air conditioning is not required. S. S. 10 to 15 Suspended type. 55--Floor Type Split-System Air Conditioning Unit--Series SS Capacities Model SSI SS2 SS3 SS4 ssto SSI3 SSI5 Heating Capacity Btu per hour Hot Water at 180 Steam 2 Lb Press. 93,000 170,000 233,000 . 304,000 " 91,800 171,600 246,800 317,900 46,000 66,000 90,000 46,000 66,400 90,000 Air Capacity CFM 1120 2000 2700 3600 500 750 1000 WGS W Vi" /,' VtT V* '// Fan Speed 640 558 656 630 555 600 555 Motor Hp 1/4 1/3 1/2 3/4 1/6 1/6 1/4 Cooling Capacity Btu per hour Cold Water at 50 F 30,0001 50,0001 ,, 75,000 f 90,0001 14,000 26,000 35,000 Dir. Expansion (Freon) at 40 F 35,0001 62,0001 , 92,000 f 119,000 1 21,000 V' 31,000 42,000 * Split-System Units should be selected on CFM capacity. E.D.R. is listed for esti mating boiler load only. Heating capacities shown are for four-row coils on hot water and two-row coils on steam, and are based on entering air at 60 deg. Cooling capacities shown are for four-row coils, three-row coils marked*, and six-row coils marked**. Units are equipped with variable speed motor pulleys. Listed air capacities are maxi mum and are based on listed fan speeds with air at 60 deg. SUMMER AIR-CONDITIONING Room Cooling Unit. Series RC. Designed for single rooms in residences, offices, stores, etc., where summer air conditioning only is desired. Circulates cooled, dehumidi fied, filtered air throughout conditioned space. Direct expansion type coil with air cooled condenser. (See also Page 967) 899