2.1^3 \-r?ys construction department
AIR SURVEY
0iJ
L. V. Thfc-cher ar.d A. L. Linch
October 21, 1966
Problem: To determine:
A. Whether or not the total air-borne asbestos dust count
generated during the fabrication and installation of asbestos containing insulating materials exceeds, either
at the source or in the breathing zone, the Threshold Limit Valve of 5 million particles per cubic foot
(m.p.p.c.f.) established by the American Conference of
Governmental Industrial Hygienists (ACGIH).
f.'Sir: --** *
.-*
'4
B. Extent of air-borne asbestos contamination of the general shops area, surrounding grounds, and installation sites.
C. Total dust count for use in the evaluation of over-all atmospheric dust loading and for detection of other potential dust problems.
Note:
Item C will involve little additional cost as the differential counting of the sample is
nominal compared to the cost incurred in
procuring the sample particularly where special set-ups of work, tools, and materials are involved.
Procedure:
I. Collection
Two methods will be used for the initial 'survey:
A. Station sampling - portable.
'Tht' "Unico Constant Rate Uni-Jet" "Freon - 12" powered
sampler equipped with the improved standard midget impinger
("Unico 2000"; followed by an 0.8 micron, pore size
millipore filter (Cat. No. MAWG037U)) will be used. The
dust collected in "dust-free" distilled water in the
\ impinger will be counted at the University of Pittsburgh
Graduate School of Public Health by the method approved
by the Asbestos Textile Institute. The dust collected on
the bacffc-up filter will be counted also at the University
" of Pittsburgh. This filter will collect the particles
iu .he size range be*ovi 3 microns which is mot retained
05C
in the first stage es well es larger pertlculete which might
carry over from the impinger. The limit of resolution in
counting is-1.3 microns.