Document jkBjdrZoaX2w9O83eDp0g03Z
130
CHAPTER 6
19.48 Guide
Heat Transmission Coefficients of Building-Materials
131
Table 12.. Coefficients of Transmission (-J7)'of'Concrete Construction Floors and Ceilings
Coefficients ore expressed in Btu per- (how)'(square foot) (Fahrenheit degree difference in temperature between the air on the two sides), and are based on still air (no wind) conditions,on both sides.
type of. ceiling .
............................ TYPE OF FLOORING............... ..........
0R.1HU-
Thickness ..OF. ...
Concrete 1 (Itches)
..No . Flooring
(Concrete . Bare)
T2e or UphSt
Terrasxo. Flooring"
on Concrete
`
Tile6
Directly . on Concrete
Parquet*
Flooring In
Mastio on
Concrete
Double Wood
Floor
- -oh. Sleeper*1'
D z
- A B
CDE
No Celling-........ --..... -..................
H in. Plaster Applied to Underside of Concrete............... .................... .........
3 6 10 . ..
3 6 10
0.68 . 0.59
030
ooo pop
iSoetSi
0.59 0.52 0.44
0.66 . 0.58
0.49
0.60 0.53 0.45
0.45 0.25 1 0.41 033 2 036 _ 032 3
0.43 0.24 4 039 0.22 . 5: 034 031 6
Metal Lath and Plaster4--Suspended or Furred.... .......------------------------------- :.
3 6
10
0.38
027 . 0.37
030 ` 0.19
1
0.35
034 0.35
038 0.18
8
0.32 031 0.32 036 ; 0.17 * 9
Gypsum Board (H in.) and Plaster/-- Suspended or Furred...... ....... .......... .....
3 6
10.
0.36 035 0.35 0.33 032 0.33
0.30 .. .039. . .0.30
ooo
0.19 10 0.18 11
. 0.17... 12
Insulating Board lath (M in.) and Plaster/ Suspended or Furred................ --____....
3
6 10
0.25 0.24 0.25 031 0.15 13 0.23 033 0.23 030 . 0.15 . 14 022 031 0.22 0.19 0.14 15
`Thickness of tile assumed to be 1 in.
^Conductivity of Asphalt Tile assumed to be 3.1. Thickness of wood assumed to be ll/fa in.; thickness of mastic, H in. (k * 4.5).' Col. D*may also be used for concrete covered with carpet. * Based on in. yellow pine or hr sub-flooring and ls/6 in. hardwood finish-flooring with an air space between sub-floor and concrete.
Thickness of plaster assumed to be % in.
/Thickness of plaster assumed to.be In.
*For other thicknesses of concrete, interpolate.
13.Table
Coefficients of Transmission (U) of Concrete Floors on
Ground with Various Types of Finish Flooring
U -- 0.10a Btu per (hour) (square foot) (Fahrenheit degree temperature difference between the ground and the air over the floor). __
`Until more complete data are available, it is recommended that a coefficient of 0.10 be used for all types of concrete floors on the ground, with or without insulation. For basement wall below grade, use the same average coefficient (0.10). -A lower ground temperature should, however, be used for walls, than floors as explained in Chapter 14. For further data see A.S.H.V.E. Research Report No. 1213--Heat Loss Through Basement Walls and Floors, by F. C. Houghten, S. I. Taimuty, Carl Gutberlet and C. J. Brown (A.S.H.V.E. Transactions, Vol. 48; 1942, p. 369).
exact compliance with specifications, and a factor of safety may' be employed as a precaution when it is judged desirable.
Roof Coefficients
Computations for wood shingle roofs applied over wood stripping are based on 1 by 4 in. wood strips, spaced 2 in. apart. Values for roofs containing Spanish and French clay roofing tile are assumed the same as for slate roofs. Values for pitched roofs' in Table 16 apply , where ffie roof; is oyer a heated attic or top floor so that the heat passes, directly through the roof structure, including any interior finish material.